Revit :: Add A Prefix To All Window Numbers (Marks)
Apr 2, 2013
I have a number of windows already in the project - of differing types.
The numbering (marks) have been assigned as I created each one.
I would now like to add a prefix to the mark in the form of:
W0/01, W0/02, W0/03 etc. for ground floor windows then:
W1/01, W1/02 ... etc for first floor.
If it is not possible to break down by floor, then simply having a prefix W/01, W/02, W/03 etc. would work.
I can alter individual window types and amend the Mark to include the prefix, but it only seems to affect the one window - and not all instances of the same type.
Ideally - is it possible to set a standard prefix for use in window Marks throughout a project, regardless of type and whether it has already been inserted or in the future ?
View 4 Replies
ADVERTISEMENT
Jan 31, 2013
AutoCAD Civil 3D 2009 w/Updates, Windows XP Pro, SP3
I am looking for a tool or routine to automatically add a unique object data ID number to Points or lines of a sewer system, that extract a prefix number from a seperate object data table (a location grid of closed polygons), then add a sequential number to each selected object. For example, 12 manhole points and 3 cleanouts are located with in one grid polygon. The Grid polygon has a coded id like 61280206, I want to be able to select all the MH and CO points in that grid polygon and have the new ID numbers be 6128020601, 6128020602, 6128020603, or to be able to specify the starting number like 6128020621,(for adding new points and continuing the sequence.
Better yet would be a routine that would be able to apply this system to all the points in the entire project area, extract the number from the appropriate grid polygon, and fill the numbers in one operation.
This is for the initial id numbering of a Cities, Sewer, water and electrical system.
I have searched for and found many LISP routines that do some of this (like ODCOUNT, etc), but none that I have seen have the data table extraction abilities. I do have one that works like this and files in the prefix number from a named views. I have several thousand grid cells (880ftx880ft). Perhaps there is a way to use my polygons w/table to create and name views
View 3 Replies
View Related
Apr 5, 2011
I was wondering if there was a way in the DWG export layer dialog to change the layers like the "existing" and "demo" to a prefix, instead of a suffix.
Currently, for existing phases, when i export to DWG, let's say the topography, is said to be SITE-TOPO-EXIS, but I want to make it EX-SITE-TOPO.
It is set up as "-EXIS" which will add EXIS to all the layers in the existing phase towards the end.
If i changed it to "EX-" that just adds EX- at the end of the layer name in the phase.
Anyway so i can put that in the beginning of all the layer name for the phase?
I don't want to go into AutoCAD and use the _RENAME command if there is a lot of file to change.
View 4 Replies
View Related
Jan 6, 2013
I noticed that I don't have (ELEVATIONS) tab and also (elevation icon). See the picture. Also (Elevation Marks) in the window view are not exist.How can I regain all these?
View 6 Replies
View Related
Sep 14, 2013
I modified a Window Family file by adding a Window inset parameter. When I inserted the window into a wall, otherwise the window worked fine, but when I changed the window's Window Inset value, the frame depth changed instead of the frame's location. The frame was originally made by Sweep tool, but now when I made it by Extrusion tool, the window works fine. Anyway, for future purposes, I would like to know how to be able to use the Window Inset parameter with a frame made by Sweep tool. How do I lock the depth of the frame sweep?
The file is attached.
View 2 Replies
View Related
Jun 15, 2012
Is there a way to adjust the length of the tick marks used in dimension strings? I'd like something other than the supplied Diagonal 1/8" or Diagonal 3/64" options.
View 1 Replies
View Related
Feb 7, 2014
I created an interactive form in InDesign CC and do not like the check marks as they are not visible enough. Can I globally change the check marks to "X" marks?
View 1 Replies
View Related
Jul 4, 2013
I cant find a way of suppressing the height figured numbers (to replace with GFL and 1FL) . Prefix and suffix do the text ok but for appearance sake (ie client requirement) want to change lots ov spot heights to surpress the numbers. How can I do this - I realise its a system family but usually there are some params - not on this family though?
View 1 Replies
View Related
Nov 6, 2012
How to show the sequential numbers on the steps of stair?
I’m wondering if there is a way to show the sequential number on the steps of stair.
Also, we are all the time required to write the number of stairs, run length and rise length on the drawing. Is this possible in the Revit?
Software: AutoCAD 2014, AutoCAD C3D, AutoCAD M3D, Revit
Windows 7 (Ultimate 64 bits),
Firefox 20.0,
Kaspersky 2013.
View 4 Replies
View Related
Sep 9, 2011
I see how to put omni class numbers in Families but I cannot see how to put them in the System families like doors.
View 1 Replies
View Related
Mar 15, 2012
I am curently working on a larger projekt, where we have aprox. 4500 pcs.of furnituer designed in 4 different kind of families, generic, furnituer, furnituer systems and specialty equipment. We need to be able to asign every pcs.of funituer a seqventual serial number, we have tried to do this using an extension with a funktion called element positionerning, but we have had no success with this tool, apparently it is taking up to much memory.
View 2 Replies
View Related
Jul 18, 2013
I have subroutine that retrieves a list of detail numbers in a drawing. Sometimes there are missing numbers. I am looking to find a list of any missing numbers.
Example -
(setq List_DN (list 1 2 3 5 6 7 10 11 12 17))
Missing numbers are - 4,8,9,13,14,15,16
I would like a subroutine to take the List_DN are return the following missing numbers as text
(Get_Missing List_DN)
return
4,8-9,13-16
View 9 Replies
View Related
Feb 20, 2012
I am trying to link my parts list to a drawing however all balloons have different numbers.
I open the assembly and check everything out from vault I open my bom and change item numbers. When I get back to my drawing and apply for auto balloon I get completely different item numbers in my balloons. We just updated our software to a new 2012 version so it's maybe something with set up.
View 9 Replies
View Related
Jun 20, 2011
Is there a way to sync callout numbers to correspond with note numbers. When I add or delete notes in my drawings it takes to much time to update the callout number in the drawings. I need to figure out a way for the note and corresponding callout to change at the same time.
View 6 Replies
View Related
Jul 8, 2012
I hereby have a school note report from my little brother. He told me he had some bad notes in his last period and I would like to make a fake copy of it.
Basically, I scanned his 3th period notes and I would like to change some and add some
How you can remove numbers and add new ones over it and add numbers with the same digital code used on the old ones to put those in empty notes
View 5 Replies
View Related
Apr 22, 2005
Is it possible to add shutters on a window?
View 5 Replies
View Related
Oct 3, 2013
We have a family that errors when certain values are hit. Its realated to Automatic Sketch Dimension reassociating with work planes when two workplans over lap... Anyway, the QA team knows about this.
The problem I have is that I have an IF statement to trigger an generic error message when these two rare conditions are met. I would rather a pop up window explaining what thy can not do. "Position of legs from ends can not equal half total length" and an OK button.
Is there a "say" style command for revit formulas?
View 3 Replies
View Related
Oct 15, 2013
I'm a relatively new user to Revit (almost a year). My issue is that all of a sudden my view control bar is located so far to the left in the view window, the project browser almost covers it. I know that I can move the project browser window so that isn't all that critical. My concern is that when I want to look at a schedule it also is so far to the left of the screen I have to move the other windows to see it.
View 1 Replies
View Related
Mar 14, 2012
I have several window types in my project. Let's say that the window is 3'-0" wide by 4'-8" high - Mark #1. I want to group three of these windows and schedule the group as Mark #2 - not three separate #1 windows. How do I set up the three windows together to become a single window schedulable for the entire opening of the three windows grouped together so that the opening would read 9'-0" wide?
View 6 Replies
View Related
May 9, 2013
Cannot insert any window in this wall (its 140mm blockwork single skin trimmed to the roof above) and tried different window families. Yet I can cut an opening and also insert any door.
View 4 Replies
View Related
Aug 4, 2011
I created this little building with a pitched roof. at the 1st level I had no problems putting in openings for windows and doors, but now i created the roof and I want to put in window at front and back of the building and the window shows only up when I hold the cursor over it. what step am i missing? At one point i also got the message "rectangular opening does not cut its host"
View 2 Replies
View Related
Oct 1, 2013
how to center a window seat that extends out like a bay window. I cannot for the life of me figure this out. I am trying to center the 6' extension between an exterior (7 1/4") and interior (4") wall. I need it to be center on both interior and exterior and do not know where to measure from to accomplish that.
View 3 Replies
View Related
Mar 6, 2012
I can't put my nested window family in a curved wall. Where the problem could be situated? It has to be a normal straight window so I use my nested window families from other projects. I compared my NWF(nested window family) with the ones autodesk provides with revit but I don't find the difference. The NWF from autodesk work in a curved wall.
View 2 Replies
View Related
Dec 12, 2012
can we create multiple panels in window (revit2013)
View 1 Replies
View Related
Apr 27, 2012
How to show dimensions for window in plan , instead of default hexagon (number)
For example 60" x 48"
View 2 Replies
View Related
Dec 21, 2012
Is it possible to have window opening in two parallel walls? the window crosses to the other wall which is not host wall anymore..
View 5 Replies
View Related
Sep 25, 2013
In the file attached, there's a wall roof window joint showing the following problem: It seems like the window interferes with the joint, so that it isn't right, if the window is not situated higher than the roof slab. In the picture, the joint on the left side is correct, but the ones on the left are incorrect.
View 4 Replies
View Related
Aug 8, 2012
The window type showed up in the window schedule. But the window dimension didn't.
What's the reason of it? I know you can enter the dimension directly into the schedule. But it would be nice if it comes it automatically. See attached file.
View 2 Replies
View Related
Apr 10, 2013
I would like to add different materials in Family type window (value column drop down). How to attain this?
How to create/use shared parameters for linking data through .txt file? If possible replay with images,that will be useful to understand.
View 2 Replies
View Related
Jan 29, 2014
I have a student version of revit 2014 and all my sizing, setting out and dimensions are coming in at feet and inches. I have found out how to convert this to mm but when I load in windows and doors, all the sizes of these are in feet and inches. How to change the door and window sizes to mm so that I know what size they are.
View 2 Replies
View Related
Nov 14, 2013
How to add trim or diagonal sweeps to a curved wall. I have a circle top window in a curved wall and I need to add 1x4 trim around it.
View 1 Replies
View Related