Revit :: Way Of Suppressing Height Figured Numbers
Jul 4, 2013
I cant find a way of suppressing the height figured numbers (to replace with GFL and 1FL) . Prefix and suffix do the text ok but for appearance sake (ie client requirement) want to change lots ov spot heights to surpress the numbers. How can I do this - I realise its a system family but usually there are some params - not on this family though?
View 1 Replies
ADVERTISEMENT
Oct 25, 2012
how to apply a filter to a Floor Plan to color code my Walls by Unconnected Height for coordination purposes?
I want to disseminate which walls are currently modeled to deck and which ones stop short so I can selectively coordinate this.
This seems completely logical, but I don't see the option to allow this.
Why does Revit allow me to schedule the Length of a Wall, but not it's Height - am I missing something?
View 1 Replies
View Related
Nov 4, 2012
What does the “sample height” indicate for?I couldn't figure out what the “sample height” represent for!
View 2 Replies
View Related
Sep 15, 2012
How to set the “height” of each floor?
I’m wondering how to set the height of each floor in the Revit to adjust the “height” of the wall accordingly?
Software: AutoCAD 2014, AutoCAD C3D, AutoCAD M3D, Revit
Windows 7 (Ultimate 64 bits),
Firefox 20.0,
Kaspersky 2013.
View 9 Replies
View Related
Jul 8, 2013
Fiddling around with schedules, I found a workaround to set the row height. Simply:
1 - Add a field which doesnt' contain any data to the schedule;
2 - In the schedule view, select the field's column and in the appearance tab, define a font size to whatever size of rows you would like.
3 - When you now add the schedule to a sheet, you can see that the height of each row is bigger
4 - If you selected to show gridlines, you can define the newly added column in the schedule view to have no borders
And that's my workaround. It's way better than adding spaces and adjusting widths.
View 2 Replies
View Related
Mar 27, 2013
With no luck, I have been trying to figure out how to insert a blank value for ceiling heights in a finish schedule. There are other rooms with blank values, however it appears that rooms that once had a ceiling can no longer have a blank value. From the research I've done it seems the only way to correct this may be to delete and recreate the room.
View 3 Replies
View Related
Sep 1, 2013
Need to make a wall with varying height. For example, 3000mm at one end and 4000mm at the other. The result would be a sloped ceiling and roof. Should I make a 'mass' and attach a wall to it or is there a way to vary the height of an existing wall?
View 2 Replies
View Related
Apr 2, 2013
I have a number of windows already in the project - of differing types.
The numbering (marks) have been assigned as I created each one.
I would now like to add a prefix to the mark in the form of:
W0/01, W0/02, W0/03 etc. for ground floor windows then:
W1/01, W1/02 ... etc for first floor.
If it is not possible to break down by floor, then simply having a prefix W/01, W/02, W/03 etc. would work.
I can alter individual window types and amend the Mark to include the prefix, but it only seems to affect the one window - and not all instances of the same type.
Ideally - is it possible to set a standard prefix for use in window Marks throughout a project, regardless of type and whether it has already been inserted or in the future ?
View 4 Replies
View Related
Apr 9, 2013
Setting the height of the masonry stone,
I couldn’t figure out how the height of the masonry stone can be set.
For example, in the attached screenshot, I wanted the height to be 0.26 meter then how this can be done?
Software: AutoCAD 2014, AutoCAD C3D, AutoCAD M3D, Revit
Windows 7 (Ultimate 64 bits),
Firefox 20.0,
Kaspersky 2013.
View 4 Replies
View Related
Jan 11, 2012
Can't seem to adjust the height of a recessed can. I placed the can in a floor plan view in a ceiling and it is sitting on top of the ceiling.
View 2 Replies
View Related
Apr 3, 2013
Ive got a problem with creating elevations. When I create an elevation on my floor plan - in this instance level 5 of my 30 storey building I open up the elevation and see the attached view. Its crop region is only 3mm high and therefore only shows me the floor of level 5 instead of the whole elevation of level 5 to the underside of the level 6 slab.
View 5 Replies
View Related
May 22, 2013
Why there is no infill when there is a hight elevation change? the path is a "building pad", and I'm pretty sure normally it's filled with dirt....Did I do something with the site setting?
View 4 Replies
View Related
May 24, 2013
Is there a way to get the ceiling height automatic in a schedule?
View 4 Replies
View Related
Sep 9, 2013
How We can to change the default height Ceiling plane In Project Browser.
For example, the Default is 2600mm.
I want to Over 2800mm set.
Not in Time Drawing Ceiling.
View 2 Replies
View Related
Nov 6, 2012
How to show the sequential numbers on the steps of stair?
I’m wondering if there is a way to show the sequential number on the steps of stair.
Also, we are all the time required to write the number of stairs, run length and rise length on the drawing. Is this possible in the Revit?
Software: AutoCAD 2014, AutoCAD C3D, AutoCAD M3D, Revit
Windows 7 (Ultimate 64 bits),
Firefox 20.0,
Kaspersky 2013.
View 4 Replies
View Related
Sep 9, 2011
I see how to put omni class numbers in Families but I cannot see how to put them in the System families like doors.
View 1 Replies
View Related
Mar 15, 2012
I am curently working on a larger projekt, where we have aprox. 4500 pcs.of furnituer designed in 4 different kind of families, generic, furnituer, furnituer systems and specialty equipment. We need to be able to asign every pcs.of funituer a seqventual serial number, we have tried to do this using an extension with a funktion called element positionerning, but we have had no success with this tool, apparently it is taking up to much memory.
View 2 Replies
View Related
Nov 1, 2011
I have got a split level building with hanging light fixtures in a double height room. The cable is connected to the double height ceiling, but the fixture itself hangs right down to below the split level used in another part of the building. I have set the light fixtures level to higher level, reduced the hanging distance right down, tried change the host, but they still hang below the split level line.
The fixture is the Rectangular Hanging Light Fixture from [URL] ... And the drawing is in millimetres.
View 1 Replies
View Related
Nov 11, 2012
I am trying to control the height of the camera for a walkthrough so that I can go up stairs. I know that I can activate the "Mini Tour Building Wheel" and can do it that way but it is very clunky to use and I don't always get the right angles. Is there a simple way to control each key frame's heights like you normally would a camera (eye and target elevations)?
View 1 Replies
View Related
Feb 24, 2014
When I insert a window it sets the window at a SILL height. I would like to default inserting windows at a HEAD height. Can this be done?
View 2 Replies
View Related
Nov 16, 2012
We are creating a parametric family for our window product. We have managed to create maximum constraints for both height and width. However combined with the maximum height and width we have a maximum area alllowance. We are struggling to find a way to build this into our parametric family. How this might be achieved? Is it possible to display warning text boxes within Revit?
View 7 Replies
View Related
Sep 3, 2013
I'm building a PEMB frame family partly to teach myself and because none of the ones I could find online match the ones I'm working with. It's been a bumpy road but I've gotten the family to the point where there are parameters and elements for the flange, web, baseplate & girts.
Where I've run into a problem are the bracing flanges. The flange at the top of the column was simple enough since it's always horizontal but the beam braces are all 90 deg to the top chord. Any refrence plane or reference line drawn from the intersection of the bottom & column chords to the top chord does not move with the other chords when the family types are changed. I applied a 90 deg angular dimension constraint between the top chord and the bracing flange but when I change the pitch of the top chord by increasing the Ridge Height Revit gives me a warning message that the constraint is no longer satisfied instead of rotating the flange!
AutoCAD 2010
AutoCAD LT 2013
Revit Architecture LT 2013
View 9 Replies
View Related
Feb 24, 2012
Can you change the main header text height in a schedule?
View 2 Replies
View Related
Mar 12, 2013
We are looking for a way to document the free height, between two floor slab on two different levels, on our floorplans. We would like to use some sort of tag. And not just text.
View 9 Replies
View Related
Jul 18, 2013
I have subroutine that retrieves a list of detail numbers in a drawing. Sometimes there are missing numbers. I am looking to find a list of any missing numbers.
Example -
(setq List_DN (list 1 2 3 5 6 7 10 11 12 17))
Missing numbers are - 4,8,9,13,14,15,16
I would like a subroutine to take the List_DN are return the following missing numbers as text
(Get_Missing List_DN)
return
4,8-9,13-16
View 9 Replies
View Related
Feb 20, 2012
I am trying to link my parts list to a drawing however all balloons have different numbers.
I open the assembly and check everything out from vault I open my bom and change item numbers. When I get back to my drawing and apply for auto balloon I get completely different item numbers in my balloons. We just updated our software to a new 2012 version so it's maybe something with set up.
View 9 Replies
View Related
Jun 20, 2011
Is there a way to sync callout numbers to correspond with note numbers. When I add or delete notes in my drawings it takes to much time to update the callout number in the drawings. I need to figure out a way for the note and corresponding callout to change at the same time.
View 6 Replies
View Related
Jul 8, 2012
I hereby have a school note report from my little brother. He told me he had some bad notes in his last period and I would like to make a fake copy of it.
Basically, I scanned his 3th period notes and I would like to change some and add some
How you can remove numbers and add new ones over it and add numbers with the same digital code used on the old ones to put those in empty notes
View 5 Replies
View Related
Sep 29, 2011
when in simulation, if you suppress a feature is it totally taken out of the simulations workings?
I.e. if I was working on a project like some weighing scales and I had a load of objects on the scales and I then suppressed some of the objects, will the scales rise up a little to counteract the reduced weight?
View 5 Replies
View Related
Aug 8, 2012
I am working on an Inventor Studio animation and have noticed a problem. It appears that it is not possible to suppress/enable translational constraints. My assembly has a translational constraint that I suppressed in order to “explode” the assembly. I am animating the assembly process. Once it is put back together, I need to enable the suppressed translational constraint in order for the model to function properly.
I thought about recording two animations and then splicing the two videos together, but I am worried about the transition. I really need it to be a smooth transition in order to work.
View 1 Replies
View Related
Apr 16, 2013
I am trying to make a floorplan of my house in Revit 2013, but I am having an issue when it comes to one wall in my house. I have an opening in the Master Bedroom that leads to the bathroom. This wall has a weird arched-like opening in it and I have no clue how to make this in Revit. I have attached a sketch.
Also, my exterior walls are 7' tall but the interior walls start at 7' and go up to 8' once in the middle of the house and reduce back to 7". How does one set that up in Revit?
EDIT: May have made the image too small to see, but the top is not arched, it is actually half of a decagon.
View 3 Replies
View Related