Nov 6, 2012
How to show the sequential numbers on the steps of stair?
I’m wondering if there is a way to show the sequential number on the steps of stair.
Also, we are all the time required to write the number of stairs, run length and rise length on the drawing. Is this possible in the Revit?
Software: AutoCAD 2014, AutoCAD C3D, AutoCAD M3D, Revit
Windows 7 (Ultimate 64 bits),
Firefox 20.0,
Kaspersky 2013.
View 4 Replies
ADVERTISEMENT
Sep 19, 2011
How can I make the bottom of stair to flat instead of steps?
View 5 Replies
View Related
Mar 15, 2012
I am curently working on a larger projekt, where we have aprox. 4500 pcs.of furnituer designed in 4 different kind of families, generic, furnituer, furnituer systems and specialty equipment. We need to be able to asign every pcs.of funituer a seqventual serial number, we have tried to do this using an extension with a funktion called element positionerning, but we have had no success with this tool, apparently it is taking up to much memory.
View 2 Replies
View Related
Apr 21, 2013
I am on a project of making 12,500 tickets and so far, I'm at 500 out of 12,500 .. I was just wondering if Photoshop or other Adobe programs can Add Sequential Numbers on a particular area ON a picture,
Example: (this is what i 'm doing, i'm doing it manually, saving it one by one.. and it is taking some time, it's been 2 days already)
then..
and..
and repeat the process again ..
there.. i've tried using recording Action. How to use script, (if i have to use script, can you instruct me on a step-by-step procedure or atleast pinpoint me to a thread that explains it, because the ticket's deadline is on May 4th, and again i have 12,500 tickets to make)
also the way that i print this is first as you can see saving it one by one as .jpeg and selecting 9 of the .jpeg files, right click, then print as wallet size, for it to fit in a 8.5 / 11 paper.. there..
View 6 Replies
View Related
May 2, 2006
I've been given the task of numbering our blueprint files (.tif format). I need to add around 800 ballooned numbers to each drawing at specific locations. These are just numbers with a circle around it.
Currently, I'm manually adding the number as text and then drawing a circle around it, then the next number, another circle etc.
View 1 Replies
View Related
Apr 19, 2012
I have a large job for a client who uses antique computers. They are so old that he can't run Lightroom. As a workaround, I posted the images I wanted him to look at on SmugMug and we had a disaster. Their sequencing on screen does not match my "as shot" sorting on my Lightroom (4). Is there a way I can print sequential serial numbers/ids on my images before I upload them to SmugMug so we are always talking about the same image?
View 6 Replies
View Related
Aug 10, 2012
I am having two problems with Nikon Raw Processing and LR4.1.
1st: I am producing and processing content for ESO (European South Observatory), especially TimeLapses. Those sequences consist of hundreds of Images in hundreds of folders. Source files are either from D3s, D4, D700, D7000 or the like.
Several development changes are applied to single key images in a sequence, and those later applied to all images in that sequence. Problem is that after a certain amount of development changes (that are written in to the XMP sidecar files with LR4), hot pixels start to show up in the images that were not visible before.
Seems like the oversaturated pixel information (Hot Pixel) that is always stored within the RAW images, is lost after a certain amount of development changes.
2nd: is there a known trick how to force LR4 into updating ALL thumbnails after development changes, including those, that are outside the currently visible grid view?
It is very time consuming to manually page up and down the grid to have LR4 updating the thumbnails on each page (of for example a folder of 1200 images) so that one gets a preview of the TL sequence with the current development changes in Library View.
View 10 Replies
View Related
Dec 1, 2011
I am trying to extend a stair stringer past the start of the stair tread. See attached file. I can't seem to get it. What am I missing?
View 1 Replies
View Related
Jul 10, 2013
I have made a stair by sketch, an u-shaped one. I do have some problems with the 3d model. it will not show up correctly. I add some print screens and you can see.
View 3 Replies
View Related
Apr 3, 2012
I can't get Revit to display the cut material of a stair (landing or run) in 2013 using the new stairs... i have tried different settings in object styles, visibility/graphics, materials, details levels, phasing all without success.
Successfully show material cut pattern on a stair in section?
In the attached i have the new "Component" stair next to the old style "By Sketch" stair, the sketch stair shows the cut pattern the component one does not, this is the same section view not two sections.
View 2 Replies
View Related
Aug 11, 2013
my Stair label text "UP" in my stair.In my properties browser its already checked but still didn't showed up.Anything i need to set?
View 1 Replies
View Related
Mar 25, 2013
I have a client that needed to know the distance required to make a stair case, and when I drew it wight revit 2013, I discovered that I could manually adjust the riser height but was unable to adjust the tread length. I was also unable to end the stairs with a tread rather than a riser, witch he wanted.
View 1 Replies
View Related
Mar 22, 2012
I am having a problem adding a top landing to an external staircase. see below image.
Every time i try and add the top landing i either get boundary error messages or railings surround top landing.
View 5 Replies
View Related
Jul 25, 2013
Is it possible to create a Stair Tag with the pitch reported? I have a tag which includes the number and height of rises as well as the size of treads but I would like to include the pitch also. Obviously this would use the dimensions of the rise and tread in the formula Tan X = Rise/Tread, but how do I create this in a tag? I have looked at using a Reporting Parameter but every time I read the Wikihelp paragraph on them my eyes just glaze over as I cannot follow it at all but it does mention formulas....
View 8 Replies
View Related
Feb 22, 2013
Just Starting with new Revit LT 2013(The Comparison chart from Autodesk lists the differences between LT and Full Revit as no Massing, Rendering and no multi user collaboration) Everything else should be the same!
I'm using 'LT_USI_Residential-Default' Template for my project.In the Stair Family, I have a few options, but not the '7"max riser 11" tread' stair that is available in other Templates.Is there a way to bring that Stair Family into the Template?
Maybe I don't know the 'workarounds', but none of the Stairs available in the above Template have changeable 'width' parameter under 'Dimensions' in the properties window.No matter what I do, all Stairs are first drawn 4' wide, and then I have to edit the width, but it's a pain since I get bunch of error messages and Landings often can't complete and needed to be manually added later.Even though the Type Properties list all stairs widths as 3' min., they still all draw as 4'.What's wrong with these Stairs?
View 3 Replies
View Related
Jan 31, 2012
experiencing monolithic stair with top tread missing - see attached image. The plan has irregular treads and I did pull the top riser line away from the boundary intersection but it had not affect.Or is this just a "feature"
View 3 Replies
View Related
Jun 11, 2013
Stair tread number tool is wonderful. BUT it is being not printed properly.
Example image attached:
- 'on screen' on the left is taken from my screen. The numbers are shown correctly.
- 'after print' in the middle is a black&white pdf print by adobe pdf. you can see there is the last number missing.
- 'after print-random number missing' on the right is a coloured pdf print also by adobe pdf. several numbers are missing and it happened randomly.
View 8 Replies
View Related
May 20, 2013
Is the any way of saving settings for in particular base level and top level. Always defaults to the current view level for base - can this be overriden permanently. Same for upper level - what lvel does it automatically default. Stair by sketch often involves trial and error and redoing it each time because once done you cant change the levels, rise, width or change the number of segments governed by the path. It would be nice to not have to reset levels each time.
View 1 Replies
View Related
Mar 11, 2010
Is there a way to change the elevation of the cut line for an individual stair without changing the cut line for the entire view? The only way I know change the cut line is thru View Properties > View Range > Cut Plane.
View 7 Replies
View Related
Aug 9, 2013
Can sweep profile cut up to the bottom of stair stringer?
Find attached.
View 7 Replies
View Related
Apr 23, 2012
I use all the time L shape and U shape winder stairs in combination with the Monolithic Type.
We use to concrete the monolithic part of the stairs and then dress the stairs with treads and risers. The new tool looks that working very nice.
So OK I draw the U shape winder stair and of course i want to construct the stairs.
I want to prepape a detail plan view with dimensions only for the Monolithic Part (Concrete) of the stair but i can't find a way to dispay only the monolithic part without Treads and Riser.It is possible in 3d view but no in plan view. The news tool that calculate winder stairs is "half job done" if i can't print with dimension the concrete part of the winder stairs.
View 7 Replies
View Related
Feb 4, 2014
I currently have a situation in white my stair handrail mid post wont connect to my stair stringer. I have a C10 stair stringer and am using a modified typer square handrail system I have made. I am sure there is a setting or preference I have missed that is causing this. I have attached an image for reference.
ALSO in the image you can see the top rail does not fully attach to the end post. It sits in the middle somehow. AND that end post sits halfway off the stringer.
View 1 Replies
View Related
Dec 3, 2013
if this is easy, but how do I calculate the volume of concrete needed to pour a cast-in-place spiral stair?
View 1 Replies
View Related
Aug 11, 2012
How can I get dimensions and stair well in view to show in sheet view? Basement & 1st fl are ok but 2nd floor is not.
See attached screen shot.
View 2 Replies
View Related
Jun 6, 2012
So I'm playing around with Inventors Tube and Pipe to show how to do all of our flexible hose routing throuh our chassis. It is a large assemblly with alot of hoses, so it will take multiple views to show how to route all the hoses. I have done all the routing, but am now looking at how to document it.
I have the parts list setup to show each individual run. So for example if my assembly had two runs, my parts list would look like the following:
Item......Qty......Stock Number.........Description
1..........59".......6295645.................Gladhand to filter hose
2..........120"......6295645................Filter to Control Valve hose
Now my idea is to show a couple of ISO views on the front page, along with the parts list. On the ISO views I would make a bunch of Detail Views on the following sheets, and then in each detail view, I will use balloons to identify which lines are which.
Now say ther eare a dozen pages, I don't want people to search all 12 pages just to find which detail views Item 1 shows up in. Is there any way to automatically show in the Parts List that Item 1 is shown on pages 1,2,3,6,7,9,12 and that Item 2 is shown on pages 2,3,5,7,10,11,12? This list would populate based on which sheets have a balloon for that given item number.
Any better way to document hose runs in a large assembly? In the end the goal is so that someone could pick up the drawing package, know they are running the "Gladhand to Filter hose", find it in the parts list, and then flip to the appropriate pages that show how to route that hose.
View 9 Replies
View Related
Apr 22, 2010
How do you format cells in a table to show numbers as 3-digit decimals? I've tried this...
myTable.Cells(r, c).DataFormat = "#0.000" ' this does not work.
Is there more to it than this?
View 7 Replies
View Related
Jul 2, 2012
I have a problem where I am unsure if my upgraded template is incompatible with Revit 2013 or is there something else at play.
If I create a precast stair in default template I get "end with riser" turned on automaticaly. If I copy that stair to my template and create new stair, "end with riser" is turned off and I manually have to adjust stair afterwards.
Problem is "end with riser" is now an instance parameter of stairs and I can't find where to change the default value.
Why is the stair type that works in default template stuffed when copied to my template?
View 2 Replies
View Related
Dec 31, 2013
Why new rooms show up in lieu of existing rooms when"show previous and demo" are set for the phase filter? Every single other existing element including doors, walls, windows, etc. show in the "show previous and demo" phase filter with the exception of rooms.
View 5 Replies
View Related
Apr 2, 2013
I have a number of windows already in the project - of differing types.
The numbering (marks) have been assigned as I created each one.
I would now like to add a prefix to the mark in the form of:
W0/01, W0/02, W0/03 etc. for ground floor windows then:
W1/01, W1/02 ... etc for first floor.
If it is not possible to break down by floor, then simply having a prefix W/01, W/02, W/03 etc. would work.
I can alter individual window types and amend the Mark to include the prefix, but it only seems to affect the one window - and not all instances of the same type.
Ideally - is it possible to set a standard prefix for use in window Marks throughout a project, regardless of type and whether it has already been inserted or in the future ?
View 4 Replies
View Related
Jul 4, 2013
I cant find a way of suppressing the height figured numbers (to replace with GFL and 1FL) . Prefix and suffix do the text ok but for appearance sake (ie client requirement) want to change lots ov spot heights to surpress the numbers. How can I do this - I realise its a system family but usually there are some params - not on this family though?
View 1 Replies
View Related
Sep 9, 2011
I see how to put omni class numbers in Families but I cannot see how to put them in the System families like doors.
View 1 Replies