AutoCAD Civil 3D :: Change Pipe End Section Type In Callout
Oct 16, 2012
I can't remember how to change a pipe end section type. I have concrete and want a metal one. I right click and went to swap part, but the metal end section is not listed. The block is fine; all I need to do is to change the material type in the callout. I am using the C3D flared end section with modified text in the callout. Where to I go to change the definition?
View 3 Replies
ADVERTISEMENT
Dec 20, 2011
Quick easy way to change the default insertion size of the section and callout heads. They're too large.
View 3 Replies
View Related
Feb 20, 2013
I have lots of section views with some surfaces and pipes. Unfortunately, in a number of section views pipes are not shown in full height because the section view level range is too little. What I am wondering is - is it possible to automatically adjust section level ranges so that they fully include pipe sections? Please see also the image in the attachment.
View 2 Replies
View Related
Feb 29, 2012
I have attached a picture of my issue. I have a section view with pipes drawn in them. However, for some reason I am getting lines from different networks that aren't crossing my sample line. The purple pipe is a storm pipe and the green is the sewer. The blue lines you see are water lines, but shouldn't be on this section view.
View 7 Replies
View Related
Apr 12, 2011
I would like to show a pipe network structure on my section view. The catch- the structure is 10' away from my sample line. Is there any way to project structures onto section views? C3D 2011
Civil 3D 2012 SP4.0 Windows 7 Enterprise 64-bit
C3D 2014 SP1
Dell M6600, Core i7 @ 2.3GHz, 16 GB ram
Dell T3500 workstation, too much ram to post
View 9 Replies
View Related
Jul 23, 2013
Any end section profile style that adjusts to the attached pipe size. I have been trying for days to create this style and I cannot get it to work.
View 2 Replies
View Related
Aug 13, 2013
Is it possible to label a pipe crossing offset in section view dynamically? I see there are options to label start offset and end offset, but not at the actual crossing.
View 5 Replies
View Related
Aug 12, 2009
C3D 2009. I have a style that labels the pipe diameter in section view and the type of pipe. When I label the pipe everything shows up fine. Save the drawing and re-open and my labels are gone. I can see them when is opening but after it regenerates, gone. All layers are on display set to true. Tried too many different things and no success. This issue only happens in two drawings.
View 9 Replies
View Related
Dec 29, 2011
In 2011 the pipe network cross section labels had to be exploded or they would disappear once you closed the drawing (even with saving).
In 2012 can you close and open a drawing and have the labels not disappear?
Civil 3D 2012 SP4.0 Windows 7 Enterprise 64-bit
C3D 2014 SP1
Dell M6600, Core i7 @ 2.3GHz, 16 GB ram
Dell T3500 workstation, too much ram to post
View 3 Replies
View Related
Dec 9, 2013
How could make big size pipe with irregular section shape by using Civil 3D?
View 5 Replies
View Related
Dec 9, 2013
How could make big size pipe with irregular section shape by using Civil 3D?
View 3 Replies
View Related
Jul 25, 2013
Noticed this in R2013? Not bothering to check with 2014 yet as I don't really use it.I have three vports. TL is Profile view, TR is SV and other is 3d.
There seems to be slight difference between the pipes in the profile/sections compared with the Structure pipe crossing.
All styles are set for External walls, when swapped to internal this is still incorrect. All pipes are same size & part and are Horizontal. Sections / alignment is taken along centre of pipework.
View 5 Replies
View Related
Dec 5, 2013
As I continue my learning of AutoCad on the PC after having been a Mac CAD (non-AutoCad) user for 15+ years, another question has cropped up. My boss wants the circular "heads" of the elevation and sectional callouts to be smaller on the finished drawings. How can I control (or override) the default size of these? Or do I need to override on a case by case basis? I've searched these and other forums and what I am getting a sense of is that AutoCad controls those sizes pretty tightly so they remain annotative and AutoCad sets them at the size it thinks they should be and changing that size is not a simple process.
View 2 Replies
View Related
Jan 22, 2013
I was wondering if there exists a library for pipe network parts for items such as a standard type 1 catch basin that I can add to the existing autocad pipe network parts library. Basically I'm trying to find a shortcut so that I don't have to build all of the catch basins that I need.
View 3 Replies
View Related
Dec 27, 2003
I have these two pipes, one is 4" diameter (running horizontally) and the other is 6" diameter running at a 30degree from horizontal angle. eventually the two hit, and at that intersection I need to make the 4" pipe join to the 6"' pipe, which then continues on its merry way farther down the structure. So I can extrude the two pipes, and I can even make a union and then remove the excess of the 6" pipe, because what I am really looking for is: a cutting diagram for the joint where the remaining 4" pipe hits the 6" section. A cutting diagram for the short piece of a Y joint.
I can make this image appear on my screen, but I am then stumped as to how to unwrap the pipe into a flat section so that I can see the curvature of the cuts required in planar view, for the real pipe that I have on my shop floor.
View 9 Replies
View Related
Dec 13, 2012
What type of objects can be projected into a profile view? I know that points, feature lines, and multiview blocks can be projected with variable results. I can't even find a simple list within Civil 3D's.
-Civil 3D 2012
Fred
-Civil 3D 2013 sp2
-Windows 7 64-bit
-Intel i7 Dual Core with 2.40 GHz
-8 GB of RAM
-AMD Radeon HD 6770M
-Civil 3D user since 2007
View 9 Replies
View Related
Jan 7, 2011
Is there a way to break the Callout Boundary similar to the Section Line in Revit Arch 2011 ?
View 9 Replies
View Related
Sep 4, 2013
Civil 3D data shortcuts.
So I first created a drawing which included a surface called "CONTOURS" and an existing sewer pipe network. I then created a data shortcut of the existing sewer network and started a new drawing with a proposed sewer pipe network.
When I received better contour data, I created a new "10FT EXIST CONTOURS" surface in the existing sewer drawing and switched the reference surface for the existing sewer structures and pipes to the new "10FT EXIST CONTOURS" surface. And of course I deleted the old "CONTOURS" surface because I no longer needed it.
Now, the part that makes me want to pull all my hair out! When I open the proposed sewer drawing I get all the error messages that "Reference surface 'CONTOURS' not found in reference drawing" for all 22 of the existing sewer structures.
I've tried deleted the existing sewer network in the proposed sewer drawing and recreating the data shortcut but nothing makes the errors go away. Is there any other way the existing sewer structures could be referencing the deleted surface that I have not thought about? How to get the error messages to clear?
View 7 Replies
View Related
Dec 14, 2009
I want to change the reference surface for a pipe network with existing pipes and structures. however the changes will only affect new objects, I have to manually change the others one by one. Even with the vista open I can select multiple structures, but when I click in the reference surface column of one of the selected structures, all the others are deselected.
View 6 Replies
View Related
May 16, 2013
I am trying to find out if there is a way to change the code for the Corridor Section Points Report. See attachment.
In page 1 of the attachment you will see the names that we prefer for the different zones in our assembly as per our Standards.
On page 2 is the default names that C3D spits out as defaults (under String Cut).
We are running C3D 2012.
View 3 Replies
View Related
Aug 20, 2010
How do I change the number of section views per row/column when using the create multiple section views command? It's defaulting to 8 per row.
View 9 Replies
View Related
Jun 28, 2013
I need change type for Alignment with NET API. Alignment has property AlignmentType, but this property is read only!
In COM API Alignment not has this property. And with user interface to make it easy!
View 5 Replies
View Related
Dec 21, 2010
When creating my plan set, I need to data reference pipe networks into other drawings than that in which they were designed to show crossings in profile views or to separate out profiles into managable drawings. When I do this, if I have swapped a type-13 inlet for a 10' type R inlet or something during design, the data referenced pipe network will replace the 10' type R with a default inlet. Also if I have swapped a proposed 30" pipe for an existing 30" that have different styles, the data referenced pipe network will revert back to the proposed 30" pipe. how to make a data referenced pipe network reflect what is currently in the design drawing?
View 9 Replies
View Related
Nov 7, 2013
I would like to have my corridor section points report to have different labels for the points like Edge of Shoulder or EOP instead of labels like P2 and Hinge. Is the only way to do this to somehow change the codes in the stock subassemblies?
Civil 3D 2014
View 4 Replies
View Related
Jul 15, 2012
I created sample lines and section views for my road projects. I set all line works to appropriate layers except for "Segment and Points". Cannot change from layer "0".
I right click the existing grade on my section views, click "edit section style", click "display", then change the layer of Segments and points and click "OK", "apply".
Go back to my drawing, verify the layer but still layer "0". I tried so many times, read the manual, call friends but no luck. I am tempted to "explode" my drawing.
View 2 Replies
View Related
Apr 16, 2012
Typically when setting up a viewport in paper space I can change the viewport type at the bottom of the properties dialog box. In 2013 the option is available, but it will always snap back to undefined. I'm sure it is a setting somewhere.
View 9 Replies
View Related
Jul 15, 2013
Is there any way to change a Profile Type that has "File" assigned to it to"Layout"?
C3D 2012 SP3 & C3D 2014 SP1
Win 7 Professional 64 Bit
View 9 Replies
View Related
Sep 28, 2009
I want it to be "Angle Right" instead of "Azimuth".
View 6 Replies
View Related
Sep 5, 2013
How do I change the grid lines from solid to a dotted line in the Section View?
View 3 Replies
View Related
Nov 20, 2013
Pipe network storm pipes: Fairly new to Civil3D and trying to set up parts list for the storm sewer pipe and would like the plan view to appear as it does currently. We use a polyline for centerline of pipe, similar to dashed linetype but line and space are the same, width set to pipe width.
View 1 Replies
View Related
Sep 25, 2012
I created pipe network for my storm drain project. I have located all the structures (manhole) to all angle point of my alignment as required. Also I "insert" manhole every 400' per local code requirements using the command "network layout tools; structures only. My problem is I couldn't find the tools how to trim the pipe that pass through the manhole. Please see attached pdf file.
View 1 Replies
View Related