AutoCAD Civil 3D :: Pipe Network Storm Sewer Pipe Plan View

Nov 20, 2013

Pipe network storm pipes: Fairly new to Civil3D and trying to set up parts list for the storm sewer pipe and would like the plan view to appear as it does currently.  We use a polyline for centerline of pipe, similar to dashed linetype but line and space are the same, width set to pipe width.

View 1 Replies


ADVERTISEMENT

AutoCAD Civil 3D :: Pipe Network Structure Not Showing Up In Plan View

Feb 29, 2012

I have 7 manholes in my network, only 3 of them are visibile in the model tab though.

There is structure label on all of the manholes

I can use select similar to mark them and i get "Structure (7)".

I can even see them in the object viewer.

AutoCad 2011 & Civil3D 2011. Product Version 3.
EliteBook 8560w
Intel i7 CPU 2820QM @ 2.3GHz
8 GB RAM
NVIDIA Quadro 1000M
Windows 7 Enterprise 32 Bit

View 4 Replies View Related

AutoCAD Civil 3D :: Importing Storm In Pipe Network?

Feb 8, 2013

is there a way to get the drop down highlighted below to give me storm and sanitary instead of just "standard".

View 1 Replies View Related

AutoCAD Civil 3D :: View Looking Up Storm Pipe

Sep 3, 2013

I need creating a view up a storm pipe. We had the inside of a large diameter pipe scanned. Now I need to be able to create a view looking directly up the pipe. Is there a way to set the view so that the what I am seeing is the view from the center of the downstream end of the pipe looking to the center of the upstream end of the pipe?

View 1 Replies View Related

AutoCAD Civil 3D :: Edit Pipe Network In Plan

Aug 24, 2012

How can I edit (graphically) my pipe network in plan view without losing my elevations every time I move a node? Every time I move a node I have to re-enter my invert elevations. Is there some way to "lock" my inverts? It may be useful to know my pipes have no structures linking them (water line).

View 4 Replies View Related

AutoCAD Civil 3D :: Pipe In Same Network Won't Connect To Structure In Plan

Jan 8, 2014

I'm working in Civil 2012 and I'm putting in existing SD. I put in 2 DI's and a MH all on the same network (there is only one in my drawing) and I go to put in pipes and I click to connect to the first DI and then I'm kicked out of the command. What do I do?

View 2 Replies View Related

AutoCAD Civil 3D :: Plan Production - Pipe Network Profile Labels Are Missing In Sheets

May 6, 2012

In plan production, I have created the sheets (plan & profile) as a seperate drawing. 

when I open the sheets, the pipe network profile labels are missing in model & paper space. (attachment 01)

I tried to on/off the annotation visibility tabs in the lower right corner (attachement 03)

Note: While creating the sheets, I select the tabs for pipe network & copy pipe network labels to destination drawings (attachment 02).

View 2 Replies View Related

AutoCAD Civil 3D :: Edit Pipe Network - How To Trim Pipe That Pass Through Manhole

Sep 25, 2012

I created pipe network for my storm drain project. I have located all the structures (manhole) to all angle point of my alignment as required. Also I "insert" manhole every 400' per local code requirements using the command "network layout tools; structures only. My problem is I couldn't find the tools how to trim the pipe that pass through the manhole. Please see attached pdf file.

View 1 Replies View Related

AutoCAD Civil 3D :: Connecting Pipe To Different Pipe Network Structure

Jun 20, 2012

Using Network Layout Tools, can you attach a pipe to a structure in a different Pipe Network? 2013 Civil 3D

View 6 Replies View Related

AutoCAD Civil 3D :: Pipe Network - Crescent Road - Profile View

Jul 30, 2011

If I have a Crescent Road (P - shape) where the Alignment returns to itself, when i draw pipe network parts in profile, the pipe network gets drawn wrong, ie. the tie-in structure at the intersection is drawn at the wrong station.

My understanding is that the structures will get drawn at the station closest perpendicularly to the alignment, so the structure is going to the end station as opposed to the beginning simply because the end segment of the alignment is closer.

Is there any way to make a structure use a different perpendicular station (without shortening the alignment)?I don't want to move alignment or structure.

View 8 Replies View Related

AutoCAD Civil 3D :: Adding Pipe Network Invert Line To Profile View

Mar 2, 2012

We have a big piping job coming up and as Civil3d still lacks some of the labelling abilities we want in the profile view bands. I am updating some old vba that adds a profile line of the invert of a pipe network to a profile view effectively tracing along the bottom of the network like I know a lot of people do by hand.

My original code works on assuming that the start and end structure are at the start and end of the alignment in the revised code I want to allow for situations where this is not the case.

Leading to my question is there and easy way to find the distance a profile view part is drawn along the parent alignment or do I have  look at writing my own function possibly extracting a polyline from the alignment and finding the distance using intersectionwith and distancefrom functions with the structure.

View 2 Replies View Related

AutoCAD Civil 3D :: Add Assign Pipe Network To Profile View Band In 2011

Mar 21, 2013

I'm trying to add assign a Pipe Network to a profile view Band in Civil 3D 2011. I was using COM to add profiles to bands because I couldn't figure out how to do it in .NET. But when it comes to pipe networks I don't see how you can do that with COM. How the .NET implementation is supposed to work? Here's the code I have that works for COM, except for the pipe networks. I essentially need to assign the correct pipe network to the band.
 
public static void AddProfileToBand(this ProfileView profileView, ObjectId profObjId, List<BandItemInfo> bandStyleInfosFromSet, ObjectId profileBandSetId){
using (Transaction tr = Application.DocumentManager.MdiActiveDocument.TransactionManager.StartTransaction())

[code]....

View 1 Replies View Related

AutoCAD Civil 3D :: Adjust Elevation Of 6-inch Sewer Pipe In Profile

Oct 11, 2013

I think that our file has been corrupted. We tried to adjust the elevation of a 6-inch sewer pipe in the profile and then the display of the pipe went up to a 12-inch, even though the pipe properties still show it as a 6. All the other pipe sizes seem to be working, though we did have a similar problem with 4-inch pipe the day before and fixed it with an audit. Audit does not fix this problem. It seems to apply to all six inch pipes.

The file was created in Civil 3D 2007. We are now using C3D 2012 with SP1. My machine is 64-bit but the other person working in the file has 32-bit.

I have attached the file and the pipe in question is in the sewer network and is named SP B 11.

Is there any hope for this file? Of course this is right as we are trying to meet a deadline.

PS I tried to add the file but was size restricted, then I trimmed the file down to under 1.5 MB and was still size restricted.

View 3 Replies View Related

AutoCAD Civil 3D :: Implementing A New Survey To Begin Storm Pipe Design

Feb 8, 2013

I have recieved a survey and I am now ready to begin my design. BUT, when I try and create a "pipe network", I am unable to connect the plan view with the profile. I have everything on both the plan and profile (water, sanny, gas, cuvlerts, etc etc) which was provided by the surveyor.

How to modify pipe network into an existing survey to transpose/connect in profile and plan views.

View 5 Replies View Related

AutoCAD Civil 3D :: Default Pipe Network Layer (Not The Structures Or Pipes The Network)

Dec 7, 2012

I am using Civil 3D 2013. I work in an office where we have a few different flavors of Autocad (LT, MEP, regular vanilla AutoCAD etc...) and versions (2010 LT, 2011, 2012, 2013).

For the most part there isn't much inter-office drawing coordinate that has to happen, but there is the occasional project where multiple disciplines (Structural, Mechanical and Civil Site) have to share drawings.

The specific problem I am having is when I share my 2013 Civil 3D drawing with a user using 2011 MEP. He gets the typical rectangle for the proxy objects (in my case, my pipe networks for sanitary and storm drain). We've tried downloading and installing various object enablers, but there doesn't seem to be one for a 2013 to 2011 scenario. So I setup my parts to be on layers that he can just turn off. HOWEVER... the actual pipe network (not the structures, parts, labels etc... the network itself) ends up on layer 0. For this specific project, I do the old (ssget "x" '((8 . "0")) search to select all objects on layer 0, add those objects to a selection set (pselect), then in my modify objects dialog I filter for pipe networks, then change the layer to something other then 0.

While this is a workaround that works for me, what I really want to know is if there is a way that I can change the default layer that the network (again, not pipes, structures or text, the actual network) so I don't have to use the workaround. Any thoughts?

P.S. It's killing me that I had to create a new Autodesk login and now all my AutoCAD "street cred" is lost

"The source of expertise is not in the memorization of the minute details of a subject but in the thorough understanding of the fundamental concepts on which it is based."

View 9 Replies View Related

AutoCAD Civil 3D :: Hydraflow Storm Sewers - Import / Update Storm Network

Aug 21, 2013

I am having issues with importing / updating existing storm network.

The problem is when I update the storm network, All the outlets are added as new structures. It does not update the existing headwall / end sections.

I then have to go thru and delete the added (null) outlet structure. Then, reattach the existing outlets to the pipe network to show up in the structure data table correctly.

View 1 Replies View Related

AutoCAD Civil 3D :: How To Divert Storm Sewer Flows For Treatment

Jan 3, 2013

I need to model a diversion manhole in a storm sewer system.  The diversion will take X cfs from the system and send it to a water quality treatment facility.  After leaving the WQ facility, it will be returned to the storm sewer system at the next manhole downstream.

I tried in Hydraflow but it doesn't look like diversions are possible.  Thought about modeling up to the diversion manhole and taking that data into some other program, and then coming back into a second Hydraflow model that handles the downstream bit.

View 2 Replies View Related

AutoCAD Civil 3D :: Storm And Sanitary Sewer Analysis Stopped Working

Aug 30, 2011

I tried to open the Storm and Sanitary Sewer analysis program and got an error message.  The error message asked me to send a report but the report was rejected. 

View 8 Replies View Related

AutoCAD Civil 3D :: Pipe Network Labels

Mar 22, 2012

I have multiple profile views with a pipe network. In a number of cases, I have a pipe that extends to the end of one profile view and continues on the next. I can label the pipe on one profile but not on the other. Is there a way to add two labels to the same pipe - one label on one profile view and another label on the other profile?

View 2 Replies View Related

AutoCAD Civil 3D :: Pipe Network Not Showing Up?

Apr 10, 2013

I have lost the ability to create a pipe network in a single drawing. Sorta. I can create a pipe network, and label it, and see it in my toolspace, but it won't display it for any style in any format. I can bring in a data reference and label those, but can not see pipe or structure outlines or anything to that end. I have tried to recover, audit, purge. I am at the end, currently creating the pipe network, data referencing it in, and then just drawing lines between the labels.

View 9 Replies View Related

AutoCAD Civil 3D :: Pressure Pipe Network

Jan 16, 2013

I have created a pressure pipe network (Plan view) from own created pipes and fittings, try to create an alignment from the network but C3D tells me that the selected network part has no connected parts?

How would I connect the network in order to create an alignment? (the pipe network has got a command to do that)

View 2 Replies View Related

AutoCAD Civil 3D :: Pipe Network Labeling

Jun 11, 2013

I have a drainage model, the data for which has been imported from microdrainage into Civil3d (.sws file) .

The engineer working on the project is playing around with the Invert and Cover levels so I reload the same updated .sws file into my model almost daily expecting the information shown in the labels of the pipes and manholes to simply change. Instead mine seem to disappear and I have to relabel the whole network again.

This wouldn't be much of a problem because labeling only takes a few minutes but with this particular scheme, the client wants the labels shown in a box with a leader. When I relabel, the boxes automatically snap to the center of the manholes without a leader and i then have to drag each one away from the manhole to get the leader to show up.

View 7 Replies View Related

AutoCAD Civil 3D :: Pipe Network NOT Applying Rules

Dec 5, 2012

I'm creating a utility template.  Earlier in the day, I'm able to assign pipe and structure rules to a network and create the network based on these rules.  Within the past 30 minutes, however, it completely ignores the pipe and structure rules while creating the network.

I make sure there is a surface assigned to the network.  I make sure the pipe rules are set correctly in the parts list.  I'm using no null structures.  NOTHING HAS CHANGED EXCEPT THE POSITION OF THE MINUTE AND HOUR HANDS ON THE CLOCK! It's like the Civil 3D went out to lunch and forgot to tell me that it's going to lunch.

-Civil 3D 2012
-intel Core i7 2.4 GHz
-8 GB of RAM
Windows 7 64-bit
Fred
-Civil 3D 2013 sp2
-Windows 7 64-bit
-Intel i7 Dual Core with 2.40 GHz
-8 GB of RAM
-AMD Radeon HD 6770M
-Civil 3D user since 2007

View 1 Replies View Related

AutoCAD Civil 3D :: Pipe Network Parts Not Visible

Nov 27, 2012

I have a user having an issue with drawing pipe networks. When they draw the pipe, the structure is not visible. A label shows up, and the structure can be found in the prospector, but is not editable in the plan view (see attached image).

I have a feeling it may be an issue with our pipe networks parts list and pipe catalog location. We have found an issue with our install that defaluts our pipes catalog to our local drives, but our parts list were created using a network drive. Several users have had an issue creating pipe networks when this has happened. However once we switched the pipe catalog to the netowrk drive the issue was resolved.

When we changed the pipe catalog location, it did not resolve the issues.FYI - I have tried the basics (layers on/thawed, pipe structure style layers on/thawed, audit and purge).We are using Civil 3D '09.

View 2 Replies View Related

AutoCAD Civil 3D :: Pipe Network Fatal Error

May 22, 2012

We are having trouble with one of our C3D 2013 seats crashing (giving a fatal error) when trying to edit or do anything with a pipe network. The drawings work fine on other computers. I am trying to keep from having to remove and reinstall the software.

View 5 Replies View Related

AutoCAD Civil 3D :: Insert Structure In Pipe Network?

Dec 14, 2013

I am working on an existing Pipe Network.  I have a location where I have already placed a pipe and filled in the correct parameters for this pipe.  But I realize now that there is a concrete headwall near the end of the pipe.  So I was trying to insert the structure at the midpoint of a line I have created for OSNAP reasons so it would create the structure at the specified location.  The problem is when I move the structure to create at this location, the "Break Pipe Marker" goes away and only shows when I am at a different location along the pipe.  So I wanted to see if there was a command or feature to use to tell the software I want to place this structure at a specified location along this one section of pipe. 

I wanted to see what my options were.  I know I can grab one end of the pipe and move it to the location and then add the structure and pipe from there.  But I did this insertion under different circumstances and it broke the pipe into 2 sections while still keeping the same and adding a (1) after it, which is pretty useful when reading printouts and showing that this is actually one pipe instead of 2 pipes.

C3D 2014 SP1
DELL Precision T3600
Intel Xeon E5-1650 @ 3.20GHz
NVIDIA QUADRO 4000 Dual Monitor
32 GB RAM / Win7 Pro 64-bit

View 7 Replies View Related

AutoCAD Civil 3D :: How To Add Open Ditches To The Pipe Network

Oct 1, 2013

I can design a network of open ditches and pipes in Storm and Sanitary Analyzes to handle the flows required but when I export them back into Civil 3D the open ditches disappears. How do I add open ditches to the pipe network?

View 1 Replies View Related

AutoCAD Civil 3D :: SUDAS Pipe Network Catalog

Oct 11, 2013

Is it possible to get a Pipe Network Catalog for SUDAS specifications?? 

View 3 Replies View Related

AutoCAD Civil 3D :: Pipe Network Won't Show Up In Profile?

May 15, 2012

I am using civil 3d 2012. 

I have a network that I showed in a profile view and, to creat my proposed pipes network I simply copied the pipes and structures and used network split.

Now I have two networks, but when I project those pipes and structures into a profile they are not visible. 

If I check the profile view properties and look at the pipe networks tab, all the pipes are shown as drawn.

View 7 Replies View Related

AutoCAD Civil 3D :: Pipe Network Data Shortcuts?

Jul 24, 2012

i am currently using civil 3d 2012. I am having issues with pipe networks and my data shortcuts. when i data shortcut a pipe network into another file, sometimes my structures just disappear after saving and closing out, then reopening - like they were never there.

View 4 Replies View Related

AutoCAD Civil 3D :: Pipe Network Data Shortcut

Jul 9, 2012

I have run into a problem with my Pipe Network data shortcut.  When I am in a drawing that is referencing my Pipe Network not all of my structures are showing up.  I confirmed this by going to the prospector tab/pipe networks/storm/structures.  According to the list It is obvious that not all of my network structures are making it to the new drawing.  I've double and triple checked the source drawing to make sure that all the structures actually exist and they do.

I've deleted the data shortcut and recreated it and still nothing. 

View 8 Replies View Related