AutoCAD Civil 3D :: View Looking Up Storm Pipe

Sep 3, 2013

I need creating a view up a storm pipe. We had the inside of a large diameter pipe scanned. Now I need to be able to create a view looking directly up the pipe. Is there a way to set the view so that the what I am seeing is the view from the center of the downstream end of the pipe looking to the center of the upstream end of the pipe?

View 1 Replies


ADVERTISEMENT

AutoCAD Civil 3D :: Pipe Network Storm Sewer Pipe Plan View

Nov 20, 2013

Pipe network storm pipes: Fairly new to Civil3D and trying to set up parts list for the storm sewer pipe and would like the plan view to appear as it does currently.  We use a polyline for centerline of pipe, similar to dashed linetype but line and space are the same, width set to pipe width.

View 1 Replies View Related

AutoCAD Civil 3D :: Importing Storm In Pipe Network?

Feb 8, 2013

is there a way to get the drop down highlighted below to give me storm and sanitary instead of just "standard".

View 1 Replies View Related

AutoCAD Civil 3D :: Implementing A New Survey To Begin Storm Pipe Design

Feb 8, 2013

I have recieved a survey and I am now ready to begin my design. BUT, when I try and create a "pipe network", I am unable to connect the plan view with the profile. I have everything on both the plan and profile (water, sanny, gas, cuvlerts, etc etc) which was provided by the surveyor.

How to modify pipe network into an existing survey to transpose/connect in profile and plan views.

View 5 Replies View Related

AutoCAD Civil 3D :: Hydraflow Storm Sewers - Import / Update Storm Network

Aug 21, 2013

I am having issues with importing / updating existing storm network.

The problem is when I update the storm network, All the outlets are added as new structures. It does not update the existing headwall / end sections.

I then have to go thru and delete the added (null) outlet structure. Then, reattach the existing outlets to the pipe network to show up in the structure data table correctly.

View 1 Replies View Related

AutoCAD Civil 3D :: SSA Error 537 - Unable To Perform Multiple Storm Analysis No Storm Was Selected

Nov 21, 2013

I am working on modeling a pond riser.  I had one model with a series of small round perforations in the riser and I needed to look at a version that used larger, square cut-outs in the riser.  So, I performed a "save-as" and adjusted my orifices to match my new model requirements.  When I attempted to run the model, I received the following error: "ERROR 537 : Unable to perform multiple storm analysis, no storm was selected.". 

I have encountered this one time before and was able to go back to the first model and start over.  However, now, even when I run the first model (small round perfs), I receive the same error.

I have a storm event assigned for both models but the program does not seem to recognize this any longer. 

View 3 Replies View Related

AutoCAD Civil 3D :: Storm Crossing On Road Profile View?

Apr 16, 2012

I have a storm crossing shown on a road profile, and the ellipse that represents the storm pipe is only showing part of the inner wall (I've attached an image). This pipe is skewed slightly, but the entire pipe crosses the road alignment, and this should not make any difference.

Also, is there any way, yet, (I'm using C3D 2011) to have the label show not only the pipe name, but also the invert where the pipe crosses the road alignment, and remain dynamic,? In other words, without having to edit the label text, and lose the dynamic capability. Land Desktop would do this, but it was not dynamic, of course.

Win 7 64BIT
C3D 2013

View 7 Replies View Related

AutoCAD Civil 3D :: Storm Drain Profile View Invert Labels?

Dec 30, 2013

I've attached an image of a storm drain invert label for a storm drain profile.  As you can see, the middle manhole has all three inflow pipes labeled.  Is there a way to only label the inverts of the two pipes shown in the profile view? 

C3D 2014
Windows 7 64-bit

View 5 Replies View Related

AutoCAD Civil 3D :: Section View And Pipe

Feb 29, 2012

I have attached a picture of my issue. I have a section view with pipes drawn in them. However, for some reason I am getting lines from different networks that aren't crossing my sample line. The purple pipe is a storm pipe and the green is the sewer. The blue lines you see are water lines, but shouldn't be on this section view.

View 7 Replies View Related

AutoCAD Civil 3D :: Pipe Labels In Profile View

Apr 25, 2012

I click on my pipe in profile. Right click and add label. I see nothing, no label. All layers on and un-frozen.

View 6 Replies View Related

AutoCAD Civil 3D :: Pipe Diameter In Profile View

Feb 4, 2013

As it stands, if you view a pipe network in a profile view with no vertical exaggeration, you expect to see what is essentially an accurate long section in all directions.  However, rather than being applied perpendicularly from the center line (or arguably the invert), diameter is applied strictly vertically.

Now, this made sense in the days of hand drafting when it was far easier in a vertically exaggerated profile view to simply measure the dimension vertically rather than determining how the exaggeration affects the perpendicular distance.  But with the computer doing the measurements, is this really a problem anymore?  I've debated that to some degree it's strange to consider that the crown of the pipe may be at a (slightly) different station than the invert, but this is simply fact in the field.  And I've also thought that it's nice to be able simply measure vertically in an exaggerated profile, but I can't remember the last time I dug my scale out of the drawer.

All the theory aside, the real problem appears when you try to profile a vertical, or even a near-vertical, pipe.  The fact that the diameter is applied vertically means that the vertical centerline is shifted the length of the pipe radius downward and upward.  In other words, rather than seeing the invert and crown of the pipe, you just see one line, though it's really two lines on top of each other.

I wrote this off for the last 4 years of basic Pipe Networks because I acknowledge that storm/sanitary outside the building is rarely designed vertically, but with 2013's release of the Pressure Pipe Network, I really expected Autodesk to change the way the profile views represented pipes.

View 3 Replies View Related

AutoCAD Civil 3D :: Elevation Of Pipe Outside Top On Profile View

May 19, 2013

Need getting pipe top elevation in profile view data band? In labels it's possible to perform calculations via expressions. In data bands – not. Inablity to get pipe outside top elevation in profile view leads to dead end in my hunt for smooth workflow.

View 5 Replies View Related

AutoCAD Civil 3D :: Perpendicular Pipe In Profile View?

Dec 9, 2013

I have my alignment running up the page, it is the red line. I can show the profile of the  pipes and structures that run with the alignment but I want to she the elevations of the crossing pipes, not just the circle in the structures where they cross but the elevation of the crossing structures and pipes, (str 102-103 and 104-105). Almost like a profile that is cut and looks north (up) instead of the cut looking east west.Can I turn my profile view or take a view at a certain station or do I need to make alignments that run east west to do this? I have included a pedicure for reference.

View 3 Replies View Related

AutoCAD Civil 3D :: Pressure Pipe Deflection In Profile View

Feb 7, 2013

I created a pressure pipe with no bends since my alignment is fairly straight. However, I'm changing the elevations on the pipe using a combincation of the profile view snaps and elevation edits in the properties and it doesn't restrict my deflection to my deflection settings not does it add any bends.

Is this still a missing function in Pressure Networks? Or is there something I'm missing?

View 1 Replies View Related

AutoCAD Civil 3D :: How To Show Pipe Invert In Profile View

Jun 6, 2012

I cannot find a way to only have pipes in profile view to only show the invert (bottom) of the pipe. All my pipes are running around the same elevation and the profile is pretty busy with both invert and crown of pipe shown.

View 2 Replies View Related

AutoCAD Civil 3D :: Pipe Structure Not Correct In Profile View

Sep 6, 2013

Every structure for my Sanitary pipe network is showing up properly in the profile view except the last 2.  They're showing as rectangles when they should have the cone on top.  I've checked the properties of the correct ones and the incorrect ones and they're the same style.  I looked at the parts and I couldn't see anything wrong with them.  In the screenshot you can see that the 3 manholes on the left are the correct kind with the cone whereas the 2 on the right are just rectangles.  

View 8 Replies View Related

AutoCAD Civil 3D :: Label Pipe Crossing In Section View

Aug 13, 2013

Is it possible to label a pipe crossing offset in section view dynamically? I see there are options to label start offset and end offset, but not at the actual crossing.

View 5 Replies View Related

AutoCAD Civil 3D :: Pipe Structure Won't Show Up In Profile View

Feb 22, 2012

I've been having a problem with a pipe structure not showing up in a profile view.  I have a single pipe network with everything (pipes and other structures) showing up in the profile when I select them, right-click, and click on "Draw Parts in Profile".  Like I said, this works for all the other pipes and structures in the profile except one.  When I select the structure individually and try to draw it into the profile, it still won't work.  A friend told me to make sure that the structure is within the surface, and it is.

I'm using AutoCAD Civil 3D 2011.

View 6 Replies View Related

AutoCAD Civil 3D :: Pipe Labels Disappear In Section View

Aug 12, 2009

C3D 2009. I have a style that labels the pipe diameter in section view and the type of pipe. When I label the pipe everything shows up fine. Save the drawing and re-open and my labels are gone. I can see them when is opening but after it regenerates, gone. All layers are on display set to true. Tried too many different things and no success. This issue only happens in two drawings.

View 9 Replies View Related

AutoCAD Civil 3D :: Pipe Network Structure Not Showing Up In Plan View

Feb 29, 2012

I have 7 manholes in my network, only 3 of them are visibile in the model tab though.

There is structure label on all of the manholes

I can use select similar to mark them and i get "Structure (7)".

I can even see them in the object viewer.

AutoCad 2011 & Civil3D 2011. Product Version 3.
EliteBook 8560w
Intel i7 CPU 2820QM @ 2.3GHz
8 GB RAM
NVIDIA Quadro 1000M
Windows 7 Enterprise 32 Bit

View 4 Replies View Related

AutoCAD Civil 3D :: How To Remove Deflection In Pressure Pipe In Profile View

Dec 9, 2013

I clicked on a pressure pipe in profile view and selected "Edit Pressure Network in Profile...". The panel that came up has a button that says "Follow Surface". I did that and selected all of my pipe and entered 4 feet below surface for my water main and it put alot of deflections in my pressure pipes. How to remove the deflections?

View 2 Replies View Related

AutoCAD Civil 3D :: Pipe Network - Crescent Road - Profile View

Jul 30, 2011

If I have a Crescent Road (P - shape) where the Alignment returns to itself, when i draw pipe network parts in profile, the pipe network gets drawn wrong, ie. the tie-in structure at the intersection is drawn at the wrong station.

My understanding is that the structures will get drawn at the station closest perpendicularly to the alignment, so the structure is going to the end station as opposed to the beginning simply because the end segment of the alignment is closer.

Is there any way to make a structure use a different perpendicular station (without shortening the alignment)?I don't want to move alignment or structure.

View 8 Replies View Related

AutoCAD Civil 3D :: Adding Pipe Network Invert Line To Profile View

Mar 2, 2012

We have a big piping job coming up and as Civil3d still lacks some of the labelling abilities we want in the profile view bands. I am updating some old vba that adds a profile line of the invert of a pipe network to a profile view effectively tracing along the bottom of the network like I know a lot of people do by hand.

My original code works on assuming that the start and end structure are at the start and end of the alignment in the revised code I want to allow for situations where this is not the case.

Leading to my question is there and easy way to find the distance a profile view part is drawn along the parent alignment or do I have  look at writing my own function possibly extracting a polyline from the alignment and finding the distance using intersectionwith and distancefrom functions with the structure.

View 2 Replies View Related

AutoCAD Civil 3D :: New Part Builder Pipe Displays Incorrectly In Profile View?

Dec 31, 2013

Using part builder, I created a new pipe part for an odd-sized CMP arch pipe.  In plan view, the pipe looks good.  At first glance, I thought the pipe was drawn correctly in a profile view, but I realized that the pipe was displayed with the invert located at the wrong place in the profile view.  I thought this was because the insertion point of the new pipe part that I had made was placed at the incorrect location in part builder.

So, I swapped out the incorrect pipe size for another one that I knew was correct, and then deleted the incorrect pipe from the pipe parts list, and  went back to part builder, and placed the insertion point at the invert of the pipe; then saved the edited pipe part, ran partcatalogregen, added the "corrected" pipe part to the pipe parts list and swapped in the new corrected pipe size to the pipe network.  However, the pipe still displays incorrrectly on the profile view.

The pipe data is correct in the pipe properties: the invert is stated to be located at elevation 20.  The overall height of the pipe , 38" (3.1667') is correctly displayed on the profile view.  But the actual location of the pipe invert is not shown at the correct location, elevation 20, on the profile view.

View 4 Replies View Related

AutoCAD Civil 3D :: Add Assign Pipe Network To Profile View Band In 2011

Mar 21, 2013

I'm trying to add assign a Pipe Network to a profile view Band in Civil 3D 2011. I was using COM to add profiles to bands because I couldn't figure out how to do it in .NET. But when it comes to pipe networks I don't see how you can do that with COM. How the .NET implementation is supposed to work? Here's the code I have that works for COM, except for the pipe networks. I essentially need to assign the correct pipe network to the band.
 
public static void AddProfileToBand(this ProfileView profileView, ObjectId profObjId, List<BandItemInfo> bandStyleInfosFromSet, ObjectId profileBandSetId){
using (Transaction tr = Application.DocumentManager.MdiActiveDocument.TransactionManager.StartTransaction())

[code]....

View 1 Replies View Related

AutoCAD Civil 3D :: Pipeworks Pipe Styles - Display Setting Not Working In Profile View

May 7, 2012

Header says it all. For example, if I set a pipestyle to display the inside walls with linetype Continuous, it works ok in plan view, but not profile. 

When I select the pipe top edit its style (right click context menu), it is in the Profile View, but the changes are happening in the plan view.

Where I should set it to display how I want in the profile view?

C3D 2012 on 64bit Win 7 all up to date
Dell Precision 7core 8GB RAM
NVIDIA Quadro FX 1800M
LDT/C3D user since release 12

View 2 Replies View Related

AutoCAD Civil 3D :: Hydro Flow Storm Sewers

Oct 11, 2012

I am trying to figure out how big my pipes need to be for a storm sewer that I already have set elevations for. Every time I input the pipe and rim elevations for the network in the data tab it changes the inputs back to saying design. How do I set my own elevations for the pipe network?

View 2 Replies View Related

AutoCAD Civil 3D :: Storm Structure Rotates Automatically

Jun 26, 2013

I have an issue with headwalls rotating.  When I rotate the headwall structure to 90 degrees from the pipe, the structure rotates back automatically.  Is there a way to lock the position of the structure?

See jpeg below.

View 1 Replies View Related

AutoCAD Civil 3D :: Storm Structure Table Style

Dec 28, 2012

I have set up a table style to display the type of structure, top of casting, and invert in and out elevations. I have also added a column to display the depth (rim to sump height). When the structure is a headwall, no depth is needed; however, the table displays this data as "???". Is there a way to only show depths greater than zero within the table editor for rim to sump height?

View 2 Replies View Related

AutoCAD Civil 3D :: Storm Sewers Migrating Null Structures?

Jun 25, 2013

I have set the migration defaults to my part list and the pipes come in as expected but all the structures come in as null? I even went as far as setting every option to my rect junction NF and they still come in as null? What did I miss?

Civil 3D 2012 & 2013
HP Z210 Workstation
Intel Xeon CPU E31240 @ 3.30 Hz
12 GB Ram
64 Bit Win7 OS

View 5 Replies View Related

AutoCAD Civil 3D :: How To Divert Storm Sewer Flows For Treatment

Jan 3, 2013

I need to model a diversion manhole in a storm sewer system.  The diversion will take X cfs from the system and send it to a water quality treatment facility.  After leaving the WQ facility, it will be returned to the storm sewer system at the next manhole downstream.

I tried in Hydraflow but it doesn't look like diversions are possible.  Thought about modeling up to the diversion manhole and taking that data into some other program, and then coming back into a second Hydraflow model that handles the downstream bit.

View 2 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved