AutoCAD Civil 3D :: Elevation Of Pipe Outside Top On Profile View
May 19, 2013
Need getting pipe top elevation in profile view data band? In labels it's possible to perform calculations via expressions. In data bands – not. Inablity to get pipe outside top elevation in profile view leads to dead end in my hunt for smooth workflow.
View 5 Replies
ADVERTISEMENT
Oct 11, 2013
I think that our file has been corrupted. We tried to adjust the elevation of a 6-inch sewer pipe in the profile and then the display of the pipe went up to a 12-inch, even though the pipe properties still show it as a 6. All the other pipe sizes seem to be working, though we did have a similar problem with 4-inch pipe the day before and fixed it with an audit. Audit does not fix this problem. It seems to apply to all six inch pipes.
The file was created in Civil 3D 2007. We are now using C3D 2012 with SP1. My machine is 64-bit but the other person working in the file has 32-bit.
I have attached the file and the pipe in question is in the sewer network and is named SP B 11.
Is there any hope for this file? Of course this is right as we are trying to meet a deadline.
PS I tried to add the file but was size restricted, then I trimmed the file down to under 1.5 MB and was still size restricted.
View 3 Replies
View Related
Oct 31, 2012
I am using LISP in C3D 2012. I am trying to get the station and elevation of a point I pick in a profile view. I found the Method that will get that info, but I can';t seem to get the syntax right.This is the Method;
HRESULT FindStationAndElevationAtXY(
[in] double X,
[in] double Y,
[out] double * pStation,
[out] double * pElevation,
[out, optional] VARIANT * pInBounds
[code]...
View 4 Replies
View Related
Jun 1, 2012
We don not show CL profiles and only show the gutters on the CL profile view. We also do not used profile bands.
I need to show Superelevation on both left and right profiles complete with labeling.
Short of creating a seperate alignment for each, sampling the corridor surface, superimposing it onto the CL profile view and then creating a layout profile by drawing over the sampled surface.
View 2 Replies
View Related
Apr 25, 2012
I click on my pipe in profile. Right click and add label. I see nothing, no label. All layers on and un-frozen.
View 6 Replies
View Related
Feb 4, 2013
As it stands, if you view a pipe network in a profile view with no vertical exaggeration, you expect to see what is essentially an accurate long section in all directions. However, rather than being applied perpendicularly from the center line (or arguably the invert), diameter is applied strictly vertically.
Now, this made sense in the days of hand drafting when it was far easier in a vertically exaggerated profile view to simply measure the dimension vertically rather than determining how the exaggeration affects the perpendicular distance. But with the computer doing the measurements, is this really a problem anymore? I've debated that to some degree it's strange to consider that the crown of the pipe may be at a (slightly) different station than the invert, but this is simply fact in the field. And I've also thought that it's nice to be able simply measure vertically in an exaggerated profile, but I can't remember the last time I dug my scale out of the drawer.
All the theory aside, the real problem appears when you try to profile a vertical, or even a near-vertical, pipe. The fact that the diameter is applied vertically means that the vertical centerline is shifted the length of the pipe radius downward and upward. In other words, rather than seeing the invert and crown of the pipe, you just see one line, though it's really two lines on top of each other.
I wrote this off for the last 4 years of basic Pipe Networks because I acknowledge that storm/sanitary outside the building is rarely designed vertically, but with 2013's release of the Pressure Pipe Network, I really expected Autodesk to change the way the profile views represented pipes.
View 3 Replies
View Related
Dec 9, 2013
I have my alignment running up the page, it is the red line. I can show the profile of the pipes and structures that run with the alignment but I want to she the elevations of the crossing pipes, not just the circle in the structures where they cross but the elevation of the crossing structures and pipes, (str 102-103 and 104-105). Almost like a profile that is cut and looks north (up) instead of the cut looking east west.Can I turn my profile view or take a view at a certain station or do I need to make alignments that run east west to do this? I have included a pedicure for reference.
View 3 Replies
View Related
Feb 7, 2013
I created a pressure pipe with no bends since my alignment is fairly straight. However, I'm changing the elevations on the pipe using a combincation of the profile view snaps and elevation edits in the properties and it doesn't restrict my deflection to my deflection settings not does it add any bends.
Is this still a missing function in Pressure Networks? Or is there something I'm missing?
View 1 Replies
View Related
Jun 6, 2012
I cannot find a way to only have pipes in profile view to only show the invert (bottom) of the pipe. All my pipes are running around the same elevation and the profile is pretty busy with both invert and crown of pipe shown.
View 2 Replies
View Related
Sep 6, 2013
Every structure for my Sanitary pipe network is showing up properly in the profile view except the last 2. They're showing as rectangles when they should have the cone on top. I've checked the properties of the correct ones and the incorrect ones and they're the same style. I looked at the parts and I couldn't see anything wrong with them. In the screenshot you can see that the 3 manholes on the left are the correct kind with the cone whereas the 2 on the right are just rectangles.
View 8 Replies
View Related
Feb 22, 2012
I've been having a problem with a pipe structure not showing up in a profile view. I have a single pipe network with everything (pipes and other structures) showing up in the profile when I select them, right-click, and click on "Draw Parts in Profile". Like I said, this works for all the other pipes and structures in the profile except one. When I select the structure individually and try to draw it into the profile, it still won't work. A friend told me to make sure that the structure is within the surface, and it is.
I'm using AutoCAD Civil 3D 2011.
View 6 Replies
View Related
Dec 9, 2013
I clicked on a pressure pipe in profile view and selected "Edit Pressure Network in Profile...". The panel that came up has a button that says "Follow Surface". I did that and selected all of my pipe and entered 4 feet below surface for my water main and it put alot of deflections in my pressure pipes. How to remove the deflections?
View 2 Replies
View Related
Jul 30, 2011
If I have a Crescent Road (P - shape) where the Alignment returns to itself, when i draw pipe network parts in profile, the pipe network gets drawn wrong, ie. the tie-in structure at the intersection is drawn at the wrong station.
My understanding is that the structures will get drawn at the station closest perpendicularly to the alignment, so the structure is going to the end station as opposed to the beginning simply because the end segment of the alignment is closer.
Is there any way to make a structure use a different perpendicular station (without shortening the alignment)?I don't want to move alignment or structure.
View 8 Replies
View Related
Mar 2, 2012
We have a big piping job coming up and as Civil3d still lacks some of the labelling abilities we want in the profile view bands. I am updating some old vba that adds a profile line of the invert of a pipe network to a profile view effectively tracing along the bottom of the network like I know a lot of people do by hand.
My original code works on assuming that the start and end structure are at the start and end of the alignment in the revised code I want to allow for situations where this is not the case.
Leading to my question is there and easy way to find the distance a profile view part is drawn along the parent alignment or do I have look at writing my own function possibly extracting a polyline from the alignment and finding the distance using intersectionwith and distancefrom functions with the structure.
View 2 Replies
View Related
Dec 31, 2013
Using part builder, I created a new pipe part for an odd-sized CMP arch pipe. In plan view, the pipe looks good. At first glance, I thought the pipe was drawn correctly in a profile view, but I realized that the pipe was displayed with the invert located at the wrong place in the profile view. I thought this was because the insertion point of the new pipe part that I had made was placed at the incorrect location in part builder.
So, I swapped out the incorrect pipe size for another one that I knew was correct, and then deleted the incorrect pipe from the pipe parts list, and went back to part builder, and placed the insertion point at the invert of the pipe; then saved the edited pipe part, ran partcatalogregen, added the "corrected" pipe part to the pipe parts list and swapped in the new corrected pipe size to the pipe network. However, the pipe still displays incorrrectly on the profile view.
The pipe data is correct in the pipe properties: the invert is stated to be located at elevation 20. The overall height of the pipe , 38" (3.1667') is correctly displayed on the profile view. But the actual location of the pipe invert is not shown at the correct location, elevation 20, on the profile view.
View 4 Replies
View Related
Mar 21, 2013
I'm trying to add assign a Pipe Network to a profile view Band in Civil 3D 2011. I was using COM to add profiles to bands because I couldn't figure out how to do it in .NET. But when it comes to pipe networks I don't see how you can do that with COM. How the .NET implementation is supposed to work? Here's the code I have that works for COM, except for the pipe networks. I essentially need to assign the correct pipe network to the band.
public static void AddProfileToBand(this ProfileView profileView, ObjectId profObjId, List<BandItemInfo> bandStyleInfosFromSet, ObjectId profileBandSetId){
using (Transaction tr = Application.DocumentManager.MdiActiveDocument.TransactionManager.StartTransaction())
[code]....
View 1 Replies
View Related
May 7, 2012
Header says it all. For example, if I set a pipestyle to display the inside walls with linetype Continuous, it works ok in plan view, but not profile.
When I select the pipe top edit its style (right click context menu), it is in the Profile View, but the changes are happening in the plan view.
Where I should set it to display how I want in the profile view?
C3D 2012 on 64bit Win 7 all up to date
Dell Precision 7core 8GB RAM
NVIDIA Quadro FX 1800M
LDT/C3D user since release 12
View 2 Replies
View Related
Jul 17, 2012
differences in elevations of points along Profile 2 (the proposed new road elevation) and Profile 1 (the existing elevation/surface) should be computed and shown right above the Profile 2 line. For example, if at a certain point PT 1 the elevation of the proposed road is 132.44 meters and the elevation of the existing surface is 132.45 meters, the difference is -0.01 meters and it should be shown exactly above the Profile 2 line (or a little bit above it) but not on it. The same should be done for every chosen point along the proposed profile.
So far, I have done this manually, by dragging the difference (already automatically computed and shown in one of the bands below the profiles) to the correct place for every single point. However, I don't know how to do this automatically.
View 6 Replies
View Related
Nov 20, 2013
Pipe network storm pipes: Fairly new to Civil3D and trying to set up parts list for the storm sewer pipe and would like the plan view to appear as it does currently. We use a polyline for centerline of pipe, similar to dashed linetype but line and space are the same, width set to pipe width.
View 1 Replies
View Related
Jul 20, 2012
I tried moving a Profile View and even though I selected everything at once and selected a base point and destination point, the Profile View Station and Elevation labels moved with a different offset than the Profile View itself. ?
Civil 3D 2012
View 2 Replies
View Related
Mar 22, 2013
can i use the "methods supported" " FindXYAtStationAndElevation" to retrieve a elevation and station from a profile view?
View 4 Replies
View Related
Jun 19, 2012
How do I get Civil 3D to put pipe elevation labels at even stations?
View 1 Replies
View Related
Oct 21, 2013
Can you set pipe structures and assign your own rim elevation? I don't want to use surface elevation.
View 1 Replies
View Related
Sep 7, 2011
I'm creating pipe networks to represent existing utilities and am still a novice of Civil 3D.
I am creating sewer laterals that need to connect to the sewer main that I have already created. My problem is that I can't find a way to find out the invert elevation of the sewer main at the specific point that the sewer lateral will be tying in to. I no longer have an alignment or profile for the sewer main and I hope that I don't have to re-create them. I just want to pick a point on the pipe and have it tell me that vital information. Is there any way that I can do this in plan view?
View 9 Replies
View Related
Jul 6, 2012
I'm trying to create a trench with pipe corridor along the alignment.
What I've did:
-create an alignment;
-create a pipe nework based on my alignment;
-then I made a profile with my pipe network and draw profile;
-create an assembley;
-create a corridor with one baseline.
When I've checked the corridor I found some weird spotes that are linked to zero elevation.
I've created another alignment from daylight of my corridor, but it doesn't worked.
Where mistake is???
Trench in object viewer
Profile of major alignment
Profile of Daylight
View 4 Replies
View Related
Oct 17, 2013
when creating a pipe network, and the slope of the pipe end is say at a 35% from start to end, the crown of the pipe is at a 90 degree angle from the invert elevation (straight up). So if I have an invert elevation of 288.3' the pipe crown elevation is at 292.5'. I need to show the end of the pipe crown perpendicular to the invert elevation so that it reads 292.0'!
View 5 Replies
View Related
Dec 10, 2013
I would like to know if it is possible to display the pipe inlet/outlet elevation in my structure label. It seems like it is not possible.It is possible to use the inlet/outlet elevation of the pipe in my pipe label however I would like to display it in my structure.
View 2 Replies
View Related
Jan 21, 2013
I have a surface profile 1 and a corresponding water level profile 1 of a flood plain. Now I get an updated surface profile 2 and the engineer ask me to ajust the water level according to the difference of surface level 1 and 2.
How can I add a irregular distance (water depth) to surface profile 1?
View 9 Replies
View Related
Jun 20, 2008
In the profile band the elevations are set to 3 decimal places. I just want to get it to 2 places.
View 3 Replies
View Related
Sep 25, 2012
I need to know how to display a proposed profile elevation in the major station alignment label, I mean, for example, I want to read in the label "0+000, 494.444". I've already edited my major station label style adding a (profile type) Reference text, and it only displays "?". I suppose I need to associate it with the correct profile, but I've not figured out how to. I show you how the label looks in the attached image.
View 8 Replies
View Related
Nov 4, 2013
I'm working with a structure profile label style and it seems like the only way to anchor the position of the label is based on offsets from the structure itself... Any way to position the label based on the top of the profile view, so that I could make all of my labels horizontally aligned above the profile view?
View 9 Replies
View Related