AutoCAD Civil 3D :: Structure Label - Pipe Inlet And Outlet Elevation
Dec 10, 2013
I would like to know if it is possible to display the pipe inlet/outlet elevation in my structure label. It seems like it is not possible.It is possible to use the inlet/outlet elevation of the pipe in my pipe label however I would like to display it in my structure.
View 2 Replies
ADVERTISEMENT
May 8, 2013
On grade Inlet Inlet-01 does not have two outlet links. At least one stormwater sewer pipe and a bypass gutter link must be defined.How do I add another link?
View 1 Replies
View Related
Jan 8, 2013
I have a pipe network created that is shown in multiple drawings. I created labels for the structures showing Rims and Inverts. How to put the Rim info on a different layer than the Invert info? Right now the label has 3 different components...I feel like there has to be a way to put each component on different layers...
View 6 Replies
View Related
May 21, 2013
I need to make a structure label that defines the "PIPE FALL" for each incoming pipe. By "PIPE FALL", I mean the elevation difference between the bottom of the structure and the incoming pipe invert elevation.
Actually, I thought it was going to be pretty simple, just by doing:
PIPE FALL = INCOMING PIPE INVERT ELEVATION - OUTGOING PIPE INVERT ELEVATION <CONNECTED PIPE OPPOSITE STRUCTURE NAME>
or
PIPE FALL = INCOMING PIPE INVERT ELEVATION - SUMP ELEVATION <CONNECTED PIPE OPPOSITE STRUCTURE NAME>
I just need to define the elevation difference between the bottom of the structure and the incoming pipe invert elevation.
View 9 Replies
View Related
Jul 30, 2013
Water main pipe network profile labels for structures do not attach to the structure properly in C3D 2014 (this same label style works fine in all previous versions of the software, through the 2013 release). The labels come into the drawing at a northing of 0 rather than attaching to the structure itself. However, if you grip edit and reset the labels, they reset to their correct attachment point. Additionally, if you attempt to grip edit the profile labels with Ortho mode on, it moves the label back to a northing of 0. I've created a new block for the structure, but that does not resolve the issue.
I've included a link to a Chronicle video that demonstrates the label behavior. [URL] .......
View 3 Replies
View Related
Jun 19, 2012
How do I get Civil 3D to put pipe elevation labels at even stations?
View 1 Replies
View Related
Jul 10, 2013
what structure to use to model yard inlet?
View 5 Replies
View Related
Nov 4, 2011
We use C3D 2012 (metric only) - We are attempting to customize our list of structures for Sanitary Sewers. The structure list shows sizes we do not use and we would like to modify them. However, when we try to select the "Inner Diameter" it displays a list of sizes that we can not seem to modify or add to.
I have looked at some of the XML files to try and modify or add new sizes (example: AeccStructConcentricCylinder_Metric.xml) , but they do not seem to be recognized even after I restart the program.
Here is what the file looks like:
<ColumnConstList desc="Inner Structure Diameter" dataType="float" unit="mm" name="SID" id="CCL1" visible="1" context="StructInnerDiameter" index="0">
<Item id="i0">1200.0000</Item>
<Item id="i1">1350.0000</Item>
<Item id="i2">1500.0000</Item>
<Item id="i3">1800.0000</Item>
<Item id="i4">2050.0000</Item>
<Item id="i5">2300.0000</Item>
<Item id="i6">2550.0000</Item>
I tried modifying the last line replacing 2550 with 3600.
I also tried adding a line <Item id="i7">3600.0000</Item>
I saved the XML file and restarted the program with nothing changing that I can see.
Looking for correct file(s) to edit so I can modify the LISTS that come up in the piping modules.
View 2 Replies
View Related
Feb 12, 2008
One good thing about null structures is the way they display in 3D. They cover that gap in the pipe segments. Can I steal that shape?
I am currently using a simple cylinder for water pipe "joints" and turning it off like most people do I think.
View 4 Replies
View Related
Jun 20, 2012
Using Network Layout Tools, can you attach a pipe to a structure in a different Pipe Network? 2013 Civil 3D
View 6 Replies
View Related
Jul 11, 2013
I am trying to create an elevation label that will give me the spot elevation followed by the letters "TC" and then on the line below subtract 4 inches from the elevation followed by the letters "BC". It's easy enogh to add the letters but the simple equation of elevation - 4 inches eludes me.
View 3 Replies
View Related
Nov 26, 2013
is there a way to include the pipe min/max cover as part of the str/pipe label?
Civil 3D 2013 SP1, Win 7-64 bit
12GB RAM
View 3 Replies
View Related
Dec 16, 2010
Is there a way to show the MES Top Elevation as blank or a dash? It would be great if I could make an expression but without the use of text strings in the expression editor, I don't know how to accomplish this without using wipe out boxes over the elevations.
View 2 Replies
View Related
Aug 22, 2013
I assume nobody has been able to create a parametric part used for storm pipe networks that can have the pipes attached to a point within the structure other than the insertion, or have the elevation read from a point other than the insertion.
With that in mind, we are trying to develop a tool that would allow us to pick a strucutre, and set its "rim" elevation to a point on a proposed surface that is not at the insertion of the strucure. I am decent with lisp, but have not attempted to gather info from random points on civil ojects.
View 9 Replies
View Related
Jul 31, 2012
I have this block called gate valve. The base point is at the middle of the block. When I use this block as a style and insert it in profile it always places itself down low on the pipe. As you can see the grip is way above the top of the block and I have to move it into place anytime I use one. If I change the pipe inverts the gate valve block style lowers itself once again and I have to move it up into place. I have changed the base of the block but it makes no difference.
This is how the structure look in the object viewer. Notice the one on the right is the block that needs to be raised, however in the viewer it shows placed correctly.
View 7 Replies
View Related
Jul 30, 2010
Is possible to connect a pipe to a structure and not have in connected to the structure center?
I have some two-tiered structures that are 108" dia for the bottom section and 48" dia for the top section. The 48" top section is not centered I need my small 12"-15" pipes to connect to this section of the structure.
Civil 3D 2014
Win 7
View 2 Replies
View Related
Apr 10, 2012
I have setup a reference surface for all of my structures and a sump depth of 0. All of the rims are being inserted about 1.6' above my reference surface. I am not able to grip any of the rims and lower them. It will not allow me to do so. Even if I grip the invert and make the structure extremely deep, I still cannot change the rim. I've had this problem in the past but don't recall how to correct or what I've done wrong in the setup.
View 9 Replies
View Related
Feb 19, 2013
I have my pipe networks data referenced into my Utility drawing and I'm trying to add labels to my structures (catch basins, manholes...). I made styles and selected C-TEXT as the layer for the label, but for some reason they're all on layer 0. The 0 layer is frozen in my viewport but the C-TEXT layer is not, and the labels aren't showing up (but when I thaw 0 they show up)! I can see them in model space and when I click on each label the properties shows it's on the C-TEXT layer...
View 2 Replies
View Related
May 16, 2013
I need to make a structure label that defines the "PIPE FALL" for each incoming pipe. By "PIPE FALL", I mean the elevation difference between the bottom of the structure and the incoming pipe invert elevation.
Actually, I thought it was going to be pretty simple, just by doing:
PIPE FALL = INCOMING PIPE INVERT ELEVATION - OUTGOING PIPE INVERT ELEVATION <CONNECTED PIPE OPPOSITE STRUCTURE NAME>
or
PIPE FALL = INCOMING PIPE INVERT ELEVATION - SUMP ELEVATION <CONNECTED PIPE OPPOSITE STRUCTURE NAME>
I just need to define the elevation difference between the bottom of the structure and the incoming pipe invert elevation.
View 9 Replies
View Related
Jun 8, 2012
In the Pipes Parts Builder is it possible to create a stucture that has a sloped bottom? I would like to try and built a trench drain structure.
View 1 Replies
View Related
Dec 14, 2013
I am working on an existing Pipe Network. I have a location where I have already placed a pipe and filled in the correct parameters for this pipe. But I realize now that there is a concrete headwall near the end of the pipe. So I was trying to insert the structure at the midpoint of a line I have created for OSNAP reasons so it would create the structure at the specified location. The problem is when I move the structure to create at this location, the "Break Pipe Marker" goes away and only shows when I am at a different location along the pipe. So I wanted to see if there was a command or feature to use to tell the software I want to place this structure at a specified location along this one section of pipe.
I wanted to see what my options were. I know I can grab one end of the pipe and move it to the location and then add the structure and pipe from there. But I did this insertion under different circumstances and it broke the pipe into 2 sections while still keeping the same and adding a (1) after it, which is pretty useful when reading printouts and showing that this is actually one pipe instead of 2 pipes.
C3D 2014 SP1
DELL Precision T3600
Intel Xeon E5-1650 @ 3.20GHz
NVIDIA QUADRO 4000 Dual Monitor
32 GB RAM / Win7 Pro 64-bit
View 7 Replies
View Related
May 24, 2012
we have serveral situations when we need to label both box culvert pipes and round rcp pipes on the same junction box label. what we cant do is have civil 3d differentiate between the two, it will either give us box labels or rcp labels but not both. we are using civil 3d 2011, does 2012 offer this feature and 2011 doesnt?
View 1 Replies
View Related
Aug 8, 2007
At the moment I'm trying to make a sewage pipe network, and I need something with a 7' diameter manhole. I'm trying to use Concentric Cylindrical Structures, and I'm not able to make or use a part size with an 84 in. diameter.
Is it possible for me to enter in my own value for that property, instead of having to use the pull-down menu?
View 4 Replies
View Related
Jul 25, 2012
I would like the arrowhead for the leader labaling my structure in a pipe network to attach to the outside edge of the structure. Right now it attaches to the middle of the structure and is covered by the block representing my structure.
View 9 Replies
View Related
Jan 28, 2013
I have a pipe network and a profile for it. Some of the structures have 2 inlet pipes. The pipe system more of less goes down a road, so every now and then there is a cross pipe into a structure. I have masking turned on under the structure style->profile setting. I want to see the cross pipe, so I found on here that all I need to do is under structure style->view direction (profile)->make Structure Pipe Outlines visible. I did that and still no cross pipe shows up. If I turn the masking off it is there.
View 5 Replies
View Related
Nov 13, 2013
Going through the API, I can't find a class that would let me work with pipe or structure profiles.
View 4 Replies
View Related
Mar 19, 2012
I am using a structure table as a workaroumnd to get a dynamic point tab;e that also shows station offset. It shows Name, N, E, Elev, Sta, OS
I want the elevation shown in the table to be the elevation that was pulled from the specified surface when I set the structures, PLUS 2 inches.
I tried making them all Null Structures, but I am unable to edit the height of the structure - it wants to be 1.467 and won't change.
I am not even sure what i am doing since I don't use pipe stuff all that often.
My machine is hung on the Edit Networks part dialog, which I *think* is where I was trying set the height of a structure.
I tried creating a new structure and it wants half a million parameters for a simple cylinder, even though the ONLY thing I care about is the insertion point and adding 2 inches for the table.
C3D 2012 on 64bit Win 7 all up to date
Dell Precision 7core 8GB RAM
NVIDIA Quadro FX 1800M
LDT/C3D user since release 12
View 2 Replies
View Related
Aug 3, 2013
I am create the stron network. I want structure profile elevation. How to create expression in structure reference alignment profile elevation.
View 9 Replies
View Related
Mar 5, 2012
So we have to adjust the elevation of hundreds of drainage structures from their existing elevation to the new finished ground elevation.I know we can give this information within the structure label by adding a reference surface but we would like to produce a table with three columns:
Structure No. Existing Rim Elev. Proposed Rim Elev.
How to produce such a table?
View 6 Replies
View Related
Oct 14, 2013
Is there a way that I can get a small angle between my leader and the landing? When I get to a certain angle, the text flips. I can't place the text exactly where I want it because of this. I've tried changing the Readability Bias angle in the label style but that didn't work.
View 2 Replies
View Related
Apr 11, 2013
I would like to add a wipeout to this structure label so I don't see the profile view grid lines. I want the wipeout to be the exact width and height of the label. I have tried numerous edits but can't seem to get it. What is the easiest/best way to add this wipeout?
View 9 Replies
View Related