AutoCAD Civil 3D :: Get Structure Label To Stop Flipping?

Oct 14, 2013

Is there a way that I can get a small angle between my leader and the landing? When I get to a certain angle, the text flips. I can't place the text exactly where I want it because of this. I've tried changing the Readability Bias angle in the label style but that didn't work.

View 2 Replies


ADVERTISEMENT

AutoCAD Civil 3D :: Dragged State Label Style Of Line Between Text Not Flipping?

Mar 27, 2012

I'm having trouble getting my label style to flip when in dragged state.  If I drag it off to the right, the text and line show up just fine, but if I drag to the left, the TC and FS head that way, but the line in between stays put.

View 8 Replies View Related

AutoCAD Civil 3D :: Structure Label Layering

Feb 19, 2013

I have my pipe networks data referenced into my Utility drawing and I'm trying to add labels to my structures (catch basins, manholes...). I made styles and selected C-TEXT as the layer for the label, but for some reason they're all on layer 0.  The 0 layer is frozen in my viewport but the C-TEXT layer is not, and the labels aren't showing up (but when I thaw 0 they show up)!  I can see them in model space and when I click on each label the properties shows it's on the C-TEXT layer...

View 2 Replies View Related

AutoCAD Civil 3D :: Specific Structure Label

May 16, 2013

I need to make a structure label that defines the "PIPE FALL" for each incoming pipe. By "PIPE FALL", I mean the elevation difference between the bottom of the structure and the incoming pipe invert elevation. 

Actually, I thought it was going to be pretty simple, just by doing: 

PIPE FALL = INCOMING PIPE INVERT ELEVATION - OUTGOING PIPE INVERT ELEVATION <CONNECTED PIPE OPPOSITE STRUCTURE NAME> 

or 

PIPE FALL = INCOMING PIPE INVERT ELEVATION - SUMP ELEVATION <CONNECTED PIPE OPPOSITE STRUCTURE NAME> 

I just need to define the elevation difference between the bottom of the structure and the incoming pipe invert elevation.

View 9 Replies View Related

AutoCAD Civil 3D :: Profile Structure Label Wipeout?

Apr 11, 2013

I would like to add a wipeout to this structure label so I don't see the profile view grid lines. I want the wipeout to be the exact width and height of the label. I have tried numerous edits but can't seem to get it. What is the easiest/best way to add this wipeout?

View 9 Replies View Related

AutoCAD Civil 3D :: Structure Label When There Is Mix Of Circular And Box Pipes

Mar 4, 2013

In the case of a pipe network structure, where one pipe is circular (say 60") and the other pipe is box (say 5'x4'), how can you get the "connected pipes" label to reflect [size in feet X size in feet] for the box pipe and [size in inches] for the circular pipe?

I don't see how you can conditionally affect a portion of the "connected pipes" label since it's one label object.

View 9 Replies View Related

AutoCAD Civil 3D :: Pipe Network Structure Label Layers

Jan 8, 2013

I have a pipe network created that is shown in multiple drawings.  I created labels for the structures showing Rims and Inverts. How to put the Rim info on a different layer than the Invert info?  Right now the label has 3 different components...I feel like there has to be a way to put each component on different layers...

View 6 Replies View Related

AutoCAD Civil 3D :: Specific Structure Label - Pipe Network

May 21, 2013

I need to make a structure label that defines the "PIPE FALL" for each incoming pipe. By "PIPE FALL", I mean the elevation difference between the bottom of the structure and the incoming pipe invert elevation. 

Actually, I thought it was going to be pretty simple, just by doing: 

PIPE FALL = INCOMING PIPE INVERT ELEVATION - OUTGOING PIPE INVERT ELEVATION <CONNECTED PIPE OPPOSITE STRUCTURE NAME> 

or 

PIPE FALL = INCOMING PIPE INVERT ELEVATION - SUMP ELEVATION <CONNECTED PIPE OPPOSITE STRUCTURE NAME> 

I just need to define the elevation difference between the bottom of the structure and the incoming pipe invert elevation.

View 9 Replies View Related

AutoCAD Civil 3D :: How To Handle Station Offset With Storm Structure Label

May 18, 2012

Typically when we have station offset for a storm structure shown to center of structure. How do you handle station offset with a storm structure label for say back of curb.

View 3 Replies View Related

AutoCAD Civil 3D :: Structure Label - Pipe Inlet And Outlet Elevation

Dec 10, 2013

I would like to know if it is possible to display the pipe inlet/outlet elevation in my structure label. It seems like it is not possible.It is possible to use the inlet/outlet elevation of the pipe in my pipe label however I would like to display it in my structure.

View 2 Replies View Related

AutoCAD Civil 3D :: 2014 - Pipe Network Structure Profile Label

Jul 30, 2013

Water main pipe network profile labels for structures do not attach to the structure properly in C3D 2014 (this same label style works fine in all previous versions of the software, through the 2013 release). The labels come into the drawing at a northing of 0 rather than attaching to the structure itself. However, if you grip edit and reset the labels, they reset to their correct attachment point. Additionally, if you attempt to grip edit the profile labels with Ortho mode on, it moves the label back to a northing of 0. I've created a new block for the structure, but that does not resolve the issue.

I've included a link to a Chronicle video that demonstrates the label behavior. [URL] .......

View 3 Replies View Related

AutoCAD Civil 3D :: Structure Label Component Does Not Show While Dragging Into Place

Aug 2, 2013

When I reposition structure labels (in their 'dragged state'), the component <[Structure Offset Side(CU)]> does not show up while in drag mode. Sort of makes it hard to see the limits of the label if you are trying to place it in a congested area. Watch the "LT" part of the label in the GIF below.

No, it's not that big of a deal, but alignment labels with the same component do not behave this way, so I have to wonder why the structure labels do.....

View 4 Replies View Related

AutoCAD Civil 3D :: Structure Label Reference Road Centerline Stationing?

Mar 13, 2013

I have a road with storm drain and sanitary sewer. There are three alignments, one for the road centerline, one for the sanitary sewer and one for the storm drain. I would like to label the structures with the stationing from the alignment it's on but I would also like the label to include the road centerline station perpendicular to the structure.

Something like this:

SS-MH #4

Sta. 10+00

=Road Sta. xx+xx

View 2 Replies View Related

AutoCAD Civil 3D :: Structure Label Expression - Circular Versus Rectangular

Dec 13, 2013

I'm trying to create a custom expression in a structure table that will list the "size" of the structure, wheter it be a circular or rectangular structure.  My column simply states size and I want it to label 5' for a circular or 4'x4' for a rectangular (or whatever the specific sizes are).  The thought was to create an IF function, but Structure Shape was not available to use in expressions (among other problems).  Short of using the description field (tedious) as a workaround?

In this example - CB-104 is a rectangular structure and CB-106 is a circular.  I'd like the CB-104 size to read 4'x4'.

Civil 3D 2014 SP1

View 5 Replies View Related

AutoCAD Civil 3D :: Display Order Of Connected Pipes In Structure Label

Dec 29, 2011

A way to change the display order of pipes connected to the structure in a structure label? (plan and profile) Say you have a 10", 6" and 12" pipe connected to a structure, modeled in that order, so label would place them 10, 6, 12.  we would like the label to display the order as 6,10, then 12 without having to drag the pipes off and then having to re-input inverts.

View 6 Replies View Related

AutoCAD Civil 3D :: Structure Plan View Label Goes To Edge Of Manhole Instead Of Center

Feb 10, 2013

I have a label style creating a callout bubble for structures in a pipe network, but it keeps placing the label (and therefore, the leader when dragged) at the edge of the structure, and I want it to go to the center.

View 2 Replies View Related

AutoCAD Civil 3D :: How To Base Structure Profile Label Location On Top Of Profile View

Nov 4, 2013

I'm working with a structure profile label style and it seems like the only way to anchor the position of the label is based on offsets from the structure itself... Any way to position the label based on the top of the profile view, so that I could make all of my labels horizontally aligned above the profile view?

View 9 Replies View Related

AutoCAD Civil 3D :: 2012 - Pipe Structure Editing - Changing Preset Lists For Structure Sizing

Nov 4, 2011

We use C3D 2012 (metric only) - We are attempting to customize our list of structures for Sanitary Sewers.  The structure list shows sizes we do not use and we would like to modify them.  However, when we try to select the "Inner Diameter" it displays a list of sizes that we can not seem to modify or add to.

I have looked at some of the XML files to try and modify or add new sizes (example: AeccStructConcentricCylinder_Metric.xml) , but they do not seem to be recognized even after I restart the program.

Here is what the file looks like:

<ColumnConstList desc="Inner Structure Diameter" dataType="float" unit="mm" name="SID" id="CCL1" visible="1" context="StructInnerDiameter" index="0">

<Item id="i0">1200.0000</Item>
<Item id="i1">1350.0000</Item>
<Item id="i2">1500.0000</Item>
<Item id="i3">1800.0000</Item>
<Item id="i4">2050.0000</Item>
<Item id="i5">2300.0000</Item>
<Item id="i6">2550.0000</Item>

I tried modifying the last line replacing 2550 with 3600.

I also tried adding a line  <Item id="i7">3600.0000</Item>

I saved the XML file and restarted the program with nothing changing that I can see.

Looking for correct file(s) to edit so I can modify the LISTS that come up in the piping modules.

View 2 Replies View Related

AutoCAD Civil 3D :: How To Get Pipe Structure To Be Sphere Like Null Structure

Feb 12, 2008

One good thing about null structures is the way they display in 3D. They cover that gap in the pipe segments. Can I steal that shape?
I am currently using a simple cylinder for water pipe "joints" and turning it off like most people do I think.

View 4 Replies View Related

AutoCAD Civil 3D :: Concentric Structure To Eccentric Structure

Apr 30, 2012

I have drawn a pipe network with multiple concentric sturctures. I need to make them all eccentric now. Is there an easy quick way to do this, or do I have to redraw all of them. When I go to the properties, I cannot find an option that allows me to change this.

View 2 Replies View Related

AutoCAD Civil 3D :: Point Label Size Change When Label Is Moved?

May 8, 2012

The label associated to a grading point when is moved when is moved changes its size automatically and a leader appears. After this happen no control over the grading point and its associate label. refer to the image below.

View 1 Replies View Related

AutoCAD Civil 3D :: Changing Profile Line Label Style Causes Label String To Revert To Default

Sep 6, 2012

C3D 2013. We have profile line labels, some of which get manually edited (for example, change the "<[Tangent grade(FP|P2|RN|AP|GC|UN|SD|OF)]>" to a static number such as 0.29%).

However, if you CTRL+Click and select one of these labels and change the style of that one label, then the manual edits are lost and the label reverts back to the default string.

Is there any way to turn this behavior off?

View 1 Replies View Related

AutoCAD Civil 3D :: Edit Label Text In Parcel Label

Jan 3, 2013

Is there a way to "Edit Label Text" in a Parcel area label? Similar to the way you can edit it in other styles.

View 9 Replies View Related

AutoCAD Civil 3D :: Label Profile Label Stations As Raw

Aug 8, 2013

I'm trying to label my Profile label stations as raw stations, 20~20 meters, and I'm not being able to adapt the format to STATION 0, STATION 2, without any plus zeros or +, or -, or commas, or anything, as following in the image.

Is there a easy way to do it?

View 2 Replies View Related

AutoCAD Civil 3D :: Pin A Label To Another Label

May 17, 2013

Is it possible to pin a label to another label ? Or pin a label to an object so that when the first label (or object) is moved, the other moves with it ?

View 2 Replies View Related

AutoCAD Civil 3D :: Structure Insertion To Pipe

Jul 31, 2012

I have this block called gate valve. The base point is at the middle of the block. When I use this block as a style and insert it in profile it always places itself down low on the pipe. As you can see the grip is way above the top of the block and I have to move it into place anytime I use one. If I change the pipe inverts the gate valve block style lowers itself once again and I have to move it up into place. I have changed the base of the block but it makes no difference.

This is how the structure look in the object viewer. Notice the one on the right is the block that needs to be raised, however in the viewer it shows placed correctly.

View 7 Replies View Related

AutoCAD Civil 3D :: Make Structure Table From DS

May 21, 2012

Is it bad to make a structure table from a DS? I find I get missing data when I do.

View 2 Replies View Related

AutoCAD Civil 3D :: Structure Labels In Profile?

Feb 12, 2013

I would like to have the leader arrow attached to the rim of the structure in profile view. Now they are attached along the side of the structure well below the rim. This is for the dragged labels. How can I adjust the arrowhead attachment point?

View 1 Replies View Related

AutoCAD Civil 3D :: MES Top Elevation In Structure Table

Dec 16, 2010

Is there a way to show the MES Top Elevation as blank or a dash? It would be great if I could make an expression but without the use of text strings in the expression editor, I don't know how to accomplish this without using wipe out boxes over the elevations.

View 2 Replies View Related

AutoCAD Civil 3D :: Pipe Connections To A Structure?

Jul 30, 2010

Is possible to connect a pipe to a structure and not have in connected to the structure center? 

I have some two-tiered structures that are 108" dia for the bottom section and 48" dia for the top section.  The 48" top section is not centered I need my small 12"-15" pipes to connect to this section of the structure.

Civil 3D 2014
Win 7

View 2 Replies View Related

AutoCAD Civil 3D :: Expressions In Structure Labels

Feb 21, 2013

We have a Structure Style that places a hidden block at the invert of the structure which uses an expression to accomplish Placing the invert text below the structure. (please see attached).

This particular expression was written for a 1"=30 Horz. & 1"=5' Vert. scale and we use it to label our structures in the profile view.

It works great for the 1:30 scale scenario but we also produce 1:20 & 1:50 scale plan / pfl sheets.

3 label styles can be used to accomplish this but would like to create one that would work for all three scenarios if this is possible? (Goal is 1 expression & label style as opposed to 3 of each).

I thought I had it solved & have tried various formulas but can't seem to get it to recognize the various distortions in scale. (The constant being the 5' vertical dimension for all 3 options)

50/5=10

30/5=6

20/5=4

C3D 2012 SP3 & C3D 2014 SP1
Win 7 Professional 64 Bit

View 9 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved