AutoCAD Civil 3D :: MES Top Elevation In Structure Table
Dec 16, 2010
Is there a way to show the MES Top Elevation as blank or a dash? It would be great if I could make an expression but without the use of text strings in the expression editor, I don't know how to accomplish this without using wipe out boxes over the elevations.
View 2 Replies
ADVERTISEMENT
Mar 5, 2012
So we have to adjust the elevation of hundreds of drainage structures from their existing elevation to the new finished ground elevation.I know we can give this information within the structure label by adding a reference surface but we would like to produce a table with three columns:
Structure No. Existing Rim Elev. Proposed Rim Elev.
How to produce such a table?
View 6 Replies
View Related
Aug 22, 2013
I assume nobody has been able to create a parametric part used for storm pipe networks that can have the pipes attached to a point within the structure other than the insertion, or have the elevation read from a point other than the insertion.
With that in mind, we are trying to develop a tool that would allow us to pick a strucutre, and set its "rim" elevation to a point on a proposed surface that is not at the insertion of the strucure. I am decent with lisp, but have not attempted to gather info from random points on civil ojects.
View 9 Replies
View Related
Dec 10, 2013
I would like to know if it is possible to display the pipe inlet/outlet elevation in my structure label. It seems like it is not possible.It is possible to use the inlet/outlet elevation of the pipe in my pipe label however I would like to display it in my structure.
View 2 Replies
View Related
May 21, 2012
Is it bad to make a structure table from a DS? I find I get missing data when I do.
View 2 Replies
View Related
Aug 3, 2013
I am create the stron network. I want structure profile elevation. How to create expression in structure reference alignment profile elevation.
View 9 Replies
View Related
Jul 19, 2013
I have a drainage structure table for a leaching system. I used some expressions to calculate some of the leaching pool values for the Top Of Rings etc. When the expression is false I get a zero. The expression work as expected, and I anticipated manually wiping out the false value, but when I wipeout or solid mask the values in MS they don't line up in the view port. How to effectively wipeout structure table cells?
Civil 3D 2012 & 2013
HP Z210 Workstation
Intel Xeon CPU E31240 @ 3.30 Hz
12 GB Ram
64 Bit Win7 OS
View 6 Replies
View Related
Dec 28, 2012
I have set up a table style to display the type of structure, top of casting, and invert in and out elevations. I have also added a column to display the depth (rim to sump height). When the structure is a headwall, no depth is needed; however, the table displays this data as "???". Is there a way to only show depths greater than zero within the table editor for rim to sump height?
View 2 Replies
View Related
Mar 11, 2013
Apply the transformed utm coordinates to grid coordinates to a structure table. the point tables have a grid coordinate selection but the pipe structure table does not.
View 1 Replies
View Related
Aug 30, 2012
Civil3D 2011 - How do I get pipe lengths to show up in a Structure Table? Can't find it in structures. I want to show the length of the pipes that is between two structures. The pipe slope is there but I can't find the length.
Also, comments. How do I get the Comments column in my table to actually display some sort of comments? Can I add a COMMENTS field to my structures?
View 1 Replies
View Related
Feb 5, 2013
The PLS I work under inquired if the pipe and structure tables provided in our construction plans are able to be exported to excel. The only way I know how is to use the reports manage. The problem is, the provided Pipes reports don't contain all the data we are looking for. How do I modify, or create a new, Pipe report? It seems like it should be really easy to export the data to excel..
View 5 Replies
View Related
Aug 29, 2012
I would like to add elevation values of start and end of feature line segments within a table. I can set up start and end co-ords but can't seem to find where I can add the levels?
I can add lables to the plan with levels but really would like to have a table as well as some of the segments are too small to lable on the layout.
View 1 Replies
View Related
Dec 12, 2007
How to get the Volume Elevation Table masking to work?
I can only get the Title to work correctly - everything else plots as a black blob if Fill is on. With Fill off - there is no mask.
View 1 Replies
View Related
Mar 17, 2012
I need elevation data from a surface. I need an elevation every 15' along an alignment or feature line. I would like the information as a table. I am not sure how to do this.
View 5 Replies
View Related
Aug 30, 2012
I have a pipe network that I am showing in a drainage plan. I want to show the Structure table in paper space. It seems I can only creaate the table in model spcae. I'm ok with that. I made a viewport in my paper space tab to see the table but it keps scaling to full size regardless of what the viewport scale is set to. The table is too big to fit in my drawing. I tried making a smaller viewport but the table keeps scaling to be actuall paper size. How can i get it to stop scaling so I can shrink it to fit on my sheet?
If Civil3D can't do it can I export the tbale to a data linked Spread Sheet then import that (and link it) to my paper space tab so that I can control the size of the table?
View 2 Replies
View Related
Sep 27, 2012
Is there a way to add a column that would show for each elevation range the percentage of the total area?
View 1 Replies
View Related
Nov 4, 2011
We use C3D 2012 (metric only) - We are attempting to customize our list of structures for Sanitary Sewers. The structure list shows sizes we do not use and we would like to modify them. However, when we try to select the "Inner Diameter" it displays a list of sizes that we can not seem to modify or add to.
I have looked at some of the XML files to try and modify or add new sizes (example: AeccStructConcentricCylinder_Metric.xml) , but they do not seem to be recognized even after I restart the program.
Here is what the file looks like:
<ColumnConstList desc="Inner Structure Diameter" dataType="float" unit="mm" name="SID" id="CCL1" visible="1" context="StructInnerDiameter" index="0">
<Item id="i0">1200.0000</Item>
<Item id="i1">1350.0000</Item>
<Item id="i2">1500.0000</Item>
<Item id="i3">1800.0000</Item>
<Item id="i4">2050.0000</Item>
<Item id="i5">2300.0000</Item>
<Item id="i6">2550.0000</Item>
I tried modifying the last line replacing 2550 with 3600.
I also tried adding a line <Item id="i7">3600.0000</Item>
I saved the XML file and restarted the program with nothing changing that I can see.
Looking for correct file(s) to edit so I can modify the LISTS that come up in the piping modules.
View 2 Replies
View Related
Feb 12, 2008
One good thing about null structures is the way they display in 3D. They cover that gap in the pipe segments. Can I steal that shape?
I am currently using a simple cylinder for water pipe "joints" and turning it off like most people do I think.
View 4 Replies
View Related
Apr 30, 2012
I have drawn a pipe network with multiple concentric sturctures. I need to make them all eccentric now. Is there an easy quick way to do this, or do I have to redraw all of them. When I go to the properties, I cannot find an option that allows me to change this.
View 2 Replies
View Related
Jul 11, 2013
I am trying to create an elevation label that will give me the spot elevation followed by the letters "TC" and then on the line below subtract 4 inches from the elevation followed by the letters "BC". It's easy enogh to add the letters but the simple equation of elevation - 4 inches eludes me.
View 3 Replies
View Related
Dec 19, 2012
When I snap a point to an object, the point takes on the elevation of the object. I would rather the point's elevation stay as is.
-changing osnapz variable
-latest civil 3d service pack
A few weeks ago I did not have this problem but once my computer was switched to the company's global server and c3d was reinstalled the problem appeared. Furthermore (post switchover), when a colleage of mine prepared a simple test drawing with just a line and a point, he was able to snap to that line without the point changing elevation. When he sent that drawing to me and I tried snapping the point to the object, the same problem occured with the point taking the elevation of the line object. I suspect it is a system variable issue
View 7 Replies
View Related
Apr 16, 2012
i have some existing drainage pipe and structures in a base plan that i need to change the invert (which is the easy part) and the top elevation to the existing top elevation that does not meet the minimum presect in civil 3d 2012 is there a way to change these min. to match my exisitng elevation for example i have a catch basin invert is 15.45 top is 17.56 with a 18" rcp the cover will be less than 12" and i need to change this.
View 3 Replies
View Related
Feb 23, 2012
Is there a way to force the table and table text height to stay constant despite the scale? I can do it for Point Label Styles with an Expression. But in 2011 there is no way to build an expression for a table style.
I want to create tables in the drawing where the points are and then plot them from a drawing they're Xrefed in to. The tables are too small but zooming in doesn't make them any bigger because the scale of the viewport changes and they adjust.
View 4 Replies
View Related
Feb 18, 2013
I want to know if you can link AutoCad tables to other Autocad tables on different layouts. Say I have ten sheets, each with a table for quantities of pipe length, and one sheet with a total of all quantities. Can I link cells from each separate layout sheet to the main table sheet, so that I can add them all for project totals?
View 3 Replies
View Related
Jul 31, 2012
I have this block called gate valve. The base point is at the middle of the block. When I use this block as a style and insert it in profile it always places itself down low on the pipe. As you can see the grip is way above the top of the block and I have to move it into place anytime I use one. If I change the pipe inverts the gate valve block style lowers itself once again and I have to move it up into place. I have changed the base of the block but it makes no difference.
This is how the structure look in the object viewer. Notice the one on the right is the block that needs to be raised, however in the viewer it shows placed correctly.
View 7 Replies
View Related
Feb 12, 2013
I would like to have the leader arrow attached to the rim of the structure in profile view. Now they are attached along the side of the structure well below the rim. This is for the dragged labels. How can I adjust the arrowhead attachment point?
View 1 Replies
View Related
Feb 19, 2013
I have my pipe networks data referenced into my Utility drawing and I'm trying to add labels to my structures (catch basins, manholes...). I made styles and selected C-TEXT as the layer for the label, but for some reason they're all on layer 0. The 0 layer is frozen in my viewport but the C-TEXT layer is not, and the labels aren't showing up (but when I thaw 0 they show up)! I can see them in model space and when I click on each label the properties shows it's on the C-TEXT layer...
View 2 Replies
View Related
Jul 30, 2010
Is possible to connect a pipe to a structure and not have in connected to the structure center?
I have some two-tiered structures that are 108" dia for the bottom section and 48" dia for the top section. The 48" top section is not centered I need my small 12"-15" pipes to connect to this section of the structure.
Civil 3D 2014
Win 7
View 2 Replies
View Related
Feb 21, 2013
We have a Structure Style that places a hidden block at the invert of the structure which uses an expression to accomplish Placing the invert text below the structure. (please see attached).
This particular expression was written for a 1"=30 Horz. & 1"=5' Vert. scale and we use it to label our structures in the profile view.
It works great for the 1:30 scale scenario but we also produce 1:20 & 1:50 scale plan / pfl sheets.
3 label styles can be used to accomplish this but would like to create one that would work for all three scenarios if this is possible? (Goal is 1 expression & label style as opposed to 3 of each).
I thought I had it solved & have tried various formulas but can't seem to get it to recognize the various distortions in scale. (The constant being the 5' vertical dimension for all 3 options)
50/5=10
30/5=6
20/5=4
C3D 2012 SP3 & C3D 2014 SP1
Win 7 Professional 64 Bit
View 9 Replies
View Related
May 5, 2013
how can i set the smub of a structure at the crown of a pipe not at the invert?
View 3 Replies
View Related
May 16, 2013
I need to make a structure label that defines the "PIPE FALL" for each incoming pipe. By "PIPE FALL", I mean the elevation difference between the bottom of the structure and the incoming pipe invert elevation.
Actually, I thought it was going to be pretty simple, just by doing:
PIPE FALL = INCOMING PIPE INVERT ELEVATION - OUTGOING PIPE INVERT ELEVATION <CONNECTED PIPE OPPOSITE STRUCTURE NAME>
or
PIPE FALL = INCOMING PIPE INVERT ELEVATION - SUMP ELEVATION <CONNECTED PIPE OPPOSITE STRUCTURE NAME>
I just need to define the elevation difference between the bottom of the structure and the incoming pipe invert elevation.
View 9 Replies
View Related