AutoCAD Civil 3D :: Structure In Profile View
May 5, 2013how can i set the smub of a structure at the crown of a pipe not at the invert?
View 3 Replieshow can i set the smub of a structure at the crown of a pipe not at the invert?
View 3 RepliesI'm working with a structure profile label style and it seems like the only way to anchor the position of the label is based on offsets from the structure itself... Any way to position the label based on the top of the profile view, so that I could make all of my labels horizontally aligned above the profile view?
View 9 Replies View RelatedEvery structure for my Sanitary pipe network is showing up properly in the profile view except the last 2. They're showing as rectangles when they should have the cone on top. I've checked the properties of the correct ones and the incorrect ones and they're the same style. I looked at the parts and I couldn't see anything wrong with them. In the screenshot you can see that the 3 manholes on the left are the correct kind with the cone whereas the 2 on the right are just rectangles.
View 8 Replies View RelatedI've been having a problem with a pipe structure not showing up in a profile view. I have a single pipe network with everything (pipes and other structures) showing up in the profile when I select them, right-click, and click on "Draw Parts in Profile". Like I said, this works for all the other pipes and structures in the profile except one. When I select the structure individually and try to draw it into the profile, it still won't work. A friend told me to make sure that the structure is within the surface, and it is.
I'm using AutoCAD Civil 3D 2011.
how to show the inside diameter of structure in plan and profile view. Do I have to make sump and wall thicknesses 0 to do so?
View 5 Replies View RelatedIs it possible for a civil 3d structure to be displayed correctly in profile view when the alignment does not pass through the insertion point of the structure. See the attached screen capture.
The rectangular structure is a storage tank and there will be a pipe coming in on one end and the exit pipe will be on the adjacent side at the far end, just as the alignment shows - but the structure doesn't show correctly, or now how I expected.
where to change the text height and color for the lower band where the stations are. Also, how do I get the exist grade and proposed grade to show at the specified stations vertically like LDD used to do it.
Second, how do i mask the pipe in the manholes on the profile. Right now i can see the pipe inside the manhole. I clicked "enable masking" under the structure properties but no luck.
I tried moving a Profile View and even though I selected everything at once and selected a base point and destination point, the Profile View Station and Elevation labels moved with a different offset than the Profile View itself. ?
Civil 3D 2012
I would like to have the leader arrow attached to the rim of the structure in profile view. Now they are attached along the side of the structure well below the rim. This is for the dragged labels. How can I adjust the arrowhead attachment point?
View 1 Replies View RelatedI would like to add a wipeout to this structure label so I don't see the profile view grid lines. I want the wipeout to be the exact width and height of the label. I have tried numerous edits but can't seem to get it. What is the easiest/best way to add this wipeout?
View 9 Replies View RelatedI have a pipe network and a profile for it. Some of the structures have 2 inlet pipes. The pipe system more of less goes down a road, so every now and then there is a cross pipe into a structure. I have masking turned on under the structure style->profile setting. I want to see the cross pipe, so I found on here that all I need to do is under structure style->view direction (profile)->make Structure Pipe Outlines visible. I did that and still no cross pipe shows up. If I turn the masking off it is there.
View 5 Replies View RelatedSee attached .pdf file.
I would like to delete the horizontal line (white line) from our sanitary profile structure. I have outlined it with a yellow cloud. I want to permanently delete it from our style. I can access the style in the Prospector but cannot figure out how to edit the block to delete the line in question.
profile structure doesn't update when changed. First, the rim to sump value will not change with sump defined by depth and trying to change the sump depth (going deeper and no rules exist). Second, change to define sump by elevation and the sump elevation changes and the grip changes to the correct elevation, but the part outline doesn't change. I've read where the part catalogue location should be updated. I did.
View 3 Replies View RelatedAny way to label my structures in profile with a vertical line that shows the structure ID, Station number, invert data, etc. all on an adjustable length line. Ive got it worked out for how to show it on a fixed length line, but the problem is when you have multiple structures in close proximity the labels tend to overlap. Dragging the labels upward pull the leader line compnent with them and they do not remain anchored to the structure. When I say leader, I am not referring to the dragged state as that creates a leade with a landing at an angle. What I really want is a line component that stay perfectly vertical and remains anchored to the structure insertion point even though I drag the text of the label upward. Is there a way to do this? Seaching the internet and reviewing ym texts has yet to yield an answer.
View 7 Replies View RelatedWater main pipe network profile labels for structures do not attach to the structure properly in C3D 2014 (this same label style works fine in all previous versions of the software, through the 2013 release). The labels come into the drawing at a northing of 0 rather than attaching to the structure itself. However, if you grip edit and reset the labels, they reset to their correct attachment point. Additionally, if you attempt to grip edit the profile labels with Ortho mode on, it moves the label back to a northing of 0. I've created a new block for the structure, but that does not resolve the issue.
I've included a link to a Chronicle video that demonstrates the label behavior. [URL] .......
I have an existing pipe network and a proposed pipe network. When I label a structure in my profile view, how do I combine the different network information? (Or do you usually have one network for both proposed and existing?)
For example, I have an existing pipe that will remain, but I will replace the structure and connect it to new pipes. On my label, I want to label proposed structure, pipes, and existing pipe using italics.
Suppose you have an existing structure that you are going to tie into with a proposed pipe.
We label existing structures with smaller text and a different color (as opposed to proposed labels)
Is there any way to label the structure where the one single proposed pipe text is a larger text size with a different color, as shown here?
Some of our structure styles for null structures are set to display as a block in profile. When we label these null structures in profile, the label dimension line extends to down to zero, way off the profile view. When I change the style to display the boundary of the null, the label pops back into place, but when I change the style back to a block, it will drop back to zero. I just upgraded to 2014 and this did not occur in 2010-2013. I've upgraded a drawing with existing profiles and also created a new pipe network and the results are the same. What changed in 2014 that would cause this?
View 4 Replies View RelatedI am create the stron network. I want structure profile elevation. How to create expression in structure reference alignment profile elevation.
View 9 Replies View RelatedNoticed this in R2013? Not bothering to check with 2014 yet as I don't really use it.I have three vports. TL is Profile view, TR is SV and other is 3d.
There seems to be slight difference between the pipes in the profile/sections compared with the Structure pipe crossing.
All styles are set for External walls, when swapped to internal this is still incorrect. All pipes are same size & part and are Horizontal. Sections / alignment is taken along centre of pipework.
I try to make curb return profile without profile view like a intersect command.
I was make curb return alignment but I can not find profile command without profile view.
I have a 10 foot profile view and a 15 foot manhole. I want to show the manhole but not the bottom 5 feet. It is extending beyond my profile view.
Civil 3D 2014 SP1
Windows 7 Professional
Intel Core Quad Q9650 3.0 GHz
8 GB, 64-bit
I have yet to produce a profile. I created a polyline and turned it into an alignment.
Looking at alignment Sample(3), I see that it is not superimposed over your surface. The polylines are, but the alignment is not. That will disallow creation of a surface profile.
Is the sample5 an alignment that sits on the surface? how come there is still no profile?
Attached are survey points that created the surface of a road embankment portion that caved-in. The road is very near a reservoir shoreline.
1. How can a surface profile be produce? I/'ve use line to change it into an alignement and then create a proile , then a profile view. But the the surface profile is missing.
2.the points having higher elevation are the top edge( road level) of the cave-n . A few few shots were take before the shorline elevations.
3. What the best way to come up with the rock volume to fill the cave-in given this surveying points., Also the shoreline elevation will be lowered some more while work is being done since the fill is not allowed to fall in the reservoir.
When plotting sections the headwall storm structures are rotated 90 degrees showing the face of the headwall not the side. How can I rotate the structure in section view.
View 1 Replies View RelatedA tabular data sheet for profiles could be very interesting.
Civil 3D (2013)
I have an issue with a profile referenced into a plan sheet that is shifted when I view it in the plan sheet viewport. The profile stationing is correct in the profile dwg file and in the plan sheet dwg it is referenced into. But when I switch from model space to paper space in my layout sheet (the file the profile dwg is referenced into) the profile moves to the wrong station within my profile view in paper space.
The profile start station is 0+00, but it shifts to -1+00 within the viewport of my layout sheet.
The scales are the same between the dwg files (50) and the Annotation scale matches the dwg scales.
I am a C3D newbie who used ground survey points (Serrano_EG_surface) that generated a Civil 3D surface. The white line is consist of arc segments that I turned into polylines and then into individual CL alignments. The first alignment ,which has its left and right offsets do not generate the profile view that I needed to be created. There was a prompt asking for a profile to choose, but I don't know where in the drawing or in the propector panel to click on.
1. Are the ground survey points good enough so that any alignments over the those areas can provide me a surface profile, a design profile, cross sections every 50 feet, so that I can submit a preliminary drawing for environmental permitting. ?
2. When I check the object browser, the aligments preceding each other are not in the same elevation it seems. Do I have to to transform each of the polylines first into a 3d polyline and then an alignment so that I can create a profile.
3. Eventually , I wish to connect all these alignments to model a 1.5 mile rural road (more like an access road to a water reservoir).
4. What's a best techniques to keep track of modeling a road.This question pertains to e.g the object browser as one of the useful aid. I've also used the inquiry tool but not used it for its full potential.
I was wondering if after drawing an alignment, creating a profile, and profile view, is there a way I can mark items along the alignment so they could show up in the profile view. I am laying out a pipeline and want to have the profile display a marker for items such as tees, elbows, reducers and other items. The marker I would like to use will be something like the vertical style grade break markers.
Also on a side note, as each of these items will have a different name, is there a way that I can add these markers and then have each one with a unique name?
1. I had trouble with profile view of the alignment line shown. What step am i missing? Are there things that is turned off?
2. How can I best come up with the right volume to fill.
3. Do I need to learn the grading tools? or could i get buy with a section profile from the alignment. ( it is not even an alignment yet)
4. How to I render a rock fill in this cave-in.
The attached aerial image , has survey or cogo points that are imported to surface, to become surface points. . So I wanted to create a surface profile below and an outline of fill above it. Iideally the side profile would look like a trapezoid, where the base is the surface proile and top would be the design embankment.
But the reason , a surveying crew went down and took shots at the shoreline and a couple shots around the cave-in walls (higher elevation on the cave-in wall cannot be surveyed, although I coud have used a laser , did not) is so that a more accurate volume of the cave in can be obtained. I tried to label how far the road edge is from edge of the cave-in . Norice the higher elevations are the top edge around the cave in area.
The ouline for the embankment will be a mild slope then breaks to a more steep slope. like 4 :1 , then 1.5:1
I was given a horizontal centerline of a 5 mile bike path. We have to stake all the even stationing every 50 feet and all the VPC's and VPT's with vertical elevation. I have created the horizontal profile and also the vertical profile including all the vertical curve information. Is there an easy way to incorporate the elevation information back into the plan view so I can create points that carry x,y & z points that I can transfer out of autocad as a .txt file so we can upload it on our gps equipment?
View 9 Replies View Related