AutoCAD Civil 3D :: Adjustable Length Leaders On Structure Labels In Profile
Aug 12, 2012
Any way to label my structures in profile with a vertical line that shows the structure ID, Station number, invert data, etc. all on an adjustable length line. Ive got it worked out for how to show it on a fixed length line, but the problem is when you have multiple structures in close proximity the labels tend to overlap. Dragging the labels upward pull the leader line compnent with them and they do not remain anchored to the structure. When I say leader, I am not referring to the dragged state as that creates a leade with a landing at an angle. What I really want is a line component that stay perfectly vertical and remains anchored to the structure insertion point even though I drag the text of the label upward. Is there a way to do this? Seaching the internet and reviewing ym texts has yet to yield an answer.
View 7 Replies
ADVERTISEMENT
Feb 12, 2013
I would like to have the leader arrow attached to the rim of the structure in profile view. Now they are attached along the side of the structure well below the rim. This is for the dragged labels. How can I adjust the arrowhead attachment point?
View 1 Replies
View Related
Jul 9, 2013
I need labeling my alignment. Ive been trying to figure out a way to label my alignment in drawing with a 45° line that guides another line and text oriented by view that names the station and a setting that starts a count, like "COURVE 1, COURVE 2", from the start to the end of the alignment. All on an adjustable length line, but all I got is fixed length lines, and I'm having overlapping problems when I have multiple horizontal geometry points or other points to label.
Dragging the labels upward pull the leader line component with them and they do not remain anchored to the structure. When I say leader, I am not referring to the dragged state as that creates a leade with a landing at an angle. When i use the grip in the alignment, it comes to an dragged state label, it doesn't fit the pattern I need. What I really want is a line component anchored to the alignment point even though I drag the "Line 2" and the text of the label upward or downward, while these are still oriented by the view.
View 2 Replies
View Related
Oct 16, 2012
Suppose you have an existing structure that you are going to tie into with a proposed pipe.
We label existing structures with smaller text and a different color (as opposed to proposed labels)
Is there any way to label the structure where the one single proposed pipe text is a larger text size with a different color, as shown here?
View 2 Replies
View Related
Aug 20, 2013
Some of our structure styles for null structures are set to display as a block in profile. When we label these null structures in profile, the label dimension line extends to down to zero, way off the profile view. When I change the style to display the boundary of the null, the label pops back into place, but when I change the style back to a block, it will drop back to zero. I just upgraded to 2014 and this did not occur in 2010-2013. I've upgraded a drawing with existing profiles and also created a new pipe network and the results are the same. What changed in 2014 that would cause this?
View 4 Replies
View Related
Dec 15, 2011
I am currently working with frame generator, and I have created a structure family of extruded aluminum profiles. I have a problem, and it's like to limit the length of the profiles up to 6 meters. When I insert the profile in a structure of 7 meters of length, Inventor should segment the profile in a profile of 6 meters + 1 profile 1 meter, as the maximum length of the profile should be 6 meters.
View 1 Replies
View Related
Nov 9, 2006
I have some points labeled with elevation only. If I drag the labels away from the point leaders are created but the arrows do not point to the centers of the points. I looked in the label style>dragged state>leaders but I don't see anyway to tell the leaders where to point.
View 9 Replies
View Related
Nov 4, 2013
I'm working with a structure profile label style and it seems like the only way to anchor the position of the label is based on offsets from the structure itself... Any way to position the label based on the top of the profile view, so that I could make all of my labels horizontally aligned above the profile view?
View 9 Replies
View Related
Jul 9, 2012
where to change the text height and color for the lower band where the stations are. Also, how do I get the exist grade and proposed grade to show at the specified stations vertically like LDD used to do it.
Second, how do i mask the pipe in the manholes on the profile. Right now i can see the pipe inside the manhole. I clicked "enable masking" under the structure properties but no luck.
View 2 Replies
View Related
Feb 21, 2013
We have a Structure Style that places a hidden block at the invert of the structure which uses an expression to accomplish Placing the invert text below the structure. (please see attached).
This particular expression was written for a 1"=30 Horz. & 1"=5' Vert. scale and we use it to label our structures in the profile view.
It works great for the 1:30 scale scenario but we also produce 1:20 & 1:50 scale plan / pfl sheets.
3 label styles can be used to accomplish this but would like to create one that would work for all three scenarios if this is possible? (Goal is 1 expression & label style as opposed to 3 of each).
I thought I had it solved & have tried various formulas but can't seem to get it to recognize the various distortions in scale. (The constant being the 5' vertical dimension for all 3 options)
50/5=10
30/5=6
20/5=4
C3D 2012 SP3 & C3D 2014 SP1
Win 7 Professional 64 Bit
View 9 Replies
View Related
Sep 6, 2013
I am trying to make a single point label style that will return a blank line in the label if no data is provided.
The way i have it coded now my label for a structure with only two inverts comes out looking like this:
STCB 500 Rim=300.00
12" CONC N IE=295.00
12" CONC S IE=296.00
IE=300.00
IE=300.00
I would like the number of lines returned to match the actual number of inverts in the structure and leave out the place holders.:
STCB 500 Rim=300.00
12" CONC N IE=295.00
12" CONC S IE=296.00
I can work around this by having a label style for each number of pipes, but i would also like this code to be inseted into a table style and in that case i don't know of any way to assign multiple styles to one table.
My current code looks like this:
RIM=<[Point Elevation(Uft|P2|RN|AP|GC|UN|Sn|OF)]>
<[1 SIZE(CP)]> <[1 TYPE(CP)]> <[1 DIR(CP)]> <[IE TEXT(CP)]><[1 INV(Uft|P2|RN|AP|GC|UN|Sn|OF)]>
<[2 SIZE(CP)]> <[2 TYPE(CP)]> <[2 DIR(CP)]> <[IE TEXT(CP)]><[2 INV(Uft|P2|RN|AP|GC|UN|Sn|OF)]>
<[3 SIZE(CP)]> <[3 TYPE(CP)]> <[3 DIR(CP)]> <[IE TEXT(CP)]><[3 INV(Uft|P2|RN|AP|GC|UN|Sn|OF)]>
<[4 SIZE(CP)]> <[4 TYPE(CP)]> <[4 DIR(CP)]> <[IE TEXT(CP)]><[4 INV(Uft|P2|RN|AP|GC|UN|Sn|OF)]>
LADDER <[LADDER(CP)]>
The problem is that 1 INV-4 INV are being defined by an expression that reads like
{Point Elevation}-{1 MD}
so when no data is intered for my UDP "1 MD" it returns the point elevation. I want an equation that says if rpoitn elevation -measure down=point elevation then no data is shown.
View 5 Replies
View Related
May 24, 2012
we have serveral situations when we need to label both box culvert pipes and round rcp pipes on the same junction box label. what we cant do is have civil 3d differentiate between the two, it will either give us box labels or rcp labels but not both. we are using civil 3d 2011, does 2012 offer this feature and 2011 doesnt?
View 1 Replies
View Related
Aug 16, 2012
I am labeling structures and need to use the station & offset for the street alignment not the alignment for the pipe network. It works great for the station but the offset is not working properly. It reads 0 as though it's reading the alignment for the pipe network. I've tried copying a label and adding reference text, creating a new label from scratch, putting 2 pieces of reference text in (1 for the station & 1 for the offset), and just doing the offset in the reference text instead of the station & offset...none of those have worked.
View 5 Replies
View Related
Aug 30, 2012
Civil3D 2011 - How do I get pipe lengths to show up in a Structure Table? Can't find it in structures. I want to show the length of the pipes that is between two structures. The pipe slope is there but I can't find the length.
Also, comments. How do I get the Comments column in my table to actually display some sort of comments? Can I add a COMMENTS field to my structures?
View 1 Replies
View Related
Jul 15, 2009
I have a pipe network that has labels for structures and pipes. To be able to read the information better, I click on a label and try to move by the grip. The problem is that it freezes the cursor for approximately 10 seconds before I can move it to grip the label and relocate it to another place. Did I miss any setting. Since this is slowing me down in plan production.
View 1 Replies
View Related
Mar 1, 2013
I have questions in 2012 pipe network labels.
We are having problems with running out of space and would like to squeeze the line spacing between lines to get more room. We know how to do that in standard MTEXT but can't find the equivalent in the label settings.
I have also noticed problems getting dragged pipe labels to stack. I check the box to stack on drag, but it doesn't seem to do it. We created a separate stacked label style.
View 2 Replies
View Related
May 5, 2013
how can i set the smub of a structure at the crown of a pipe not at the invert?
View 3 Replies
View Related
Apr 11, 2013
I would like to add a wipeout to this structure label so I don't see the profile view grid lines. I want the wipeout to be the exact width and height of the label. I have tried numerous edits but can't seem to get it. What is the easiest/best way to add this wipeout?
View 9 Replies
View Related
Jan 28, 2013
I have a pipe network and a profile for it. Some of the structures have 2 inlet pipes. The pipe system more of less goes down a road, so every now and then there is a cross pipe into a structure. I have masking turned on under the structure style->profile setting. I want to see the cross pipe, so I found on here that all I need to do is under structure style->view direction (profile)->make Structure Pipe Outlines visible. I did that and still no cross pipe shows up. If I turn the masking off it is there.
View 5 Replies
View Related
Jun 7, 2012
See attached .pdf file.
I would like to delete the horizontal line (white line) from our sanitary profile structure. I have outlined it with a yellow cloud. I want to permanently delete it from our style. I can access the style in the Prospector but cannot figure out how to edit the block to delete the line in question.
View 2 Replies
View Related
Sep 6, 2013
Every structure for my Sanitary pipe network is showing up properly in the profile view except the last 2. They're showing as rectangles when they should have the cone on top. I've checked the properties of the correct ones and the incorrect ones and they're the same style. I looked at the parts and I couldn't see anything wrong with them. In the screenshot you can see that the 3 manholes on the left are the correct kind with the cone whereas the 2 on the right are just rectangles.
View 8 Replies
View Related
Feb 22, 2012
I've been having a problem with a pipe structure not showing up in a profile view. I have a single pipe network with everything (pipes and other structures) showing up in the profile when I select them, right-click, and click on "Draw Parts in Profile". Like I said, this works for all the other pipes and structures in the profile except one. When I select the structure individually and try to draw it into the profile, it still won't work. A friend told me to make sure that the structure is within the surface, and it is.
I'm using AutoCAD Civil 3D 2011.
View 6 Replies
View Related
Aug 23, 2011
Autocad 2012
Part I :When I place a diameter/radius leader, it is a set length.I can move it all around the circle I'm dimensioning but the length of this leader is set. It is really short and it sucks to have to place the dimension then move it to where I want it as a second step.
Is there a setting that will allow me to drag this dimension where I want and make the leader as long as I desire?
Part II:In Autocad 2009, if you wanted to change a leader location,you could pick the text grip and it would move the end of the leader to that point then place the dimension from that point. Now picking the grip places the text and I have no control over the angle of the leader (our standards require leaders to always be a set angle from the object!)
View 6 Replies
View Related
Oct 3, 2012
profile structure doesn't update when changed. First, the rim to sump value will not change with sump defined by depth and trying to change the sump depth (going deeper and no rules exist). Second, change to define sump by elevation and the sump elevation changes and the grip changes to the correct elevation, but the part outline doesn't change. I've read where the part catalogue location should be updated. I did.
View 3 Replies
View Related
Jul 30, 2013
Water main pipe network profile labels for structures do not attach to the structure properly in C3D 2014 (this same label style works fine in all previous versions of the software, through the 2013 release). The labels come into the drawing at a northing of 0 rather than attaching to the structure itself. However, if you grip edit and reset the labels, they reset to their correct attachment point. Additionally, if you attempt to grip edit the profile labels with Ortho mode on, it moves the label back to a northing of 0. I've created a new block for the structure, but that does not resolve the issue.
I've included a link to a Chronicle video that demonstrates the label behavior. [URL] .......
View 3 Replies
View Related
May 7, 2013
I have an existing pipe network and a proposed pipe network. When I label a structure in my profile view, how do I combine the different network information? (Or do you usually have one network for both proposed and existing?)
For example, I have an existing pipe that will remain, but I will replace the structure and connect it to new pipes. On my label, I want to label proposed structure, pipes, and existing pipe using italics.
View 2 Replies
View Related
Jul 25, 2012
acad c3d 2013
My sag and Crest profile labels disappear when opening the drawing.
View 6 Replies
View Related
Oct 4, 2012
I would live to label the PVI on my Profiles but not show the PVI label at the start and end of my profile. How to set this?
View 1 Replies
View Related
Jul 9, 2013
how to show the inside diameter of structure in plan and profile view. Do I have to make sump and wall thicknesses 0 to do so?
View 5 Replies
View Related
Aug 3, 2013
I am create the stron network. I want structure profile elevation. How to create expression in structure reference alignment profile elevation.
View 9 Replies
View Related
Jul 25, 2013
Noticed this in R2013? Not bothering to check with 2014 yet as I don't really use it.I have three vports. TL is Profile view, TR is SV and other is 3d.
There seems to be slight difference between the pipes in the profile/sections compared with the Structure pipe crossing.
All styles are set for External walls, when swapped to internal this is still incorrect. All pipes are same size & part and are Horizontal. Sections / alignment is taken along centre of pipework.
View 5 Replies
View Related