AutoCAD Inventor :: Maximum Length Structure Profile
Dec 15, 2011
I am currently working with frame generator, and I have created a structure family of extruded aluminum profiles. I have a problem, and it's like to limit the length of the profiles up to 6 meters. When I insert the profile in a structure of 7 meters of length, Inventor should segment the profile in a profile of 6 meters + 1 profile 1 meter, as the maximum length of the profile should be 6 meters.
View 1 Replies
ADVERTISEMENT
Aug 12, 2012
Any way to label my structures in profile with a vertical line that shows the structure ID, Station number, invert data, etc. all on an adjustable length line. Ive got it worked out for how to show it on a fixed length line, but the problem is when you have multiple structures in close proximity the labels tend to overlap. Dragging the labels upward pull the leader line compnent with them and they do not remain anchored to the structure. When I say leader, I am not referring to the dragged state as that creates a leade with a landing at an angle. What I really want is a line component that stay perfectly vertical and remains anchored to the structure insertion point even though I drag the text of the label upward. Is there a way to do this? Seaching the internet and reviewing ym texts has yet to yield an answer.
View 7 Replies
View Related
Nov 4, 2013
I'm working with a structure profile label style and it seems like the only way to anchor the position of the label is based on offsets from the structure itself... Any way to position the label based on the top of the profile view, so that I could make all of my labels horizontally aligned above the profile view?
View 9 Replies
View Related
Jul 9, 2012
where to change the text height and color for the lower band where the stations are. Also, how do I get the exist grade and proposed grade to show at the specified stations vertically like LDD used to do it.
Second, how do i mask the pipe in the manholes on the profile. Right now i can see the pipe inside the manhole. I clicked "enable masking" under the structure properties but no luck.
View 2 Replies
View Related
Sep 11, 2013
Just tried out the Photoshop CC Image Asset Generation and it rocks. However, I can only add up to so many characters for names of the layers. Is there a way that the limit can be lifted. I think this would be beneficial especially for all the different densities for creating android assets. Other than making the layer names super short.
View 3 Replies
View Related
May 27, 2011
i send 3 banners to print in a digital output (plotter) all 3 were 5200mmx1000mm
all of them cropped to 5080mm....
Is that a PDF file limit ? is corel X4 export problem ? depends on Adobe Acrobat Compatibility number (6) ?
View 14 Replies
View Related
Aug 30, 2012
Civil3D 2011 - How do I get pipe lengths to show up in a Structure Table? Can't find it in structures. I want to show the length of the pipes that is between two structures. The pipe slope is there but I can't find the length.
Also, comments. How do I get the Comments column in my table to actually display some sort of comments? Can I add a COMMENTS field to my structures?
View 1 Replies
View Related
Oct 2, 2013
In PSE 12 what is the maximum image size, both in pixels (length x width) and file size (MB)?When will the manual be available online?
View 1 Replies
View Related
Aug 13, 2013
I'm looking for a way to add a marker with location & elevation data to the profile (not the bands).
Only mention i found in this forum was for civil2011 (i have 2013) and it is no longer available.
View 9 Replies
View Related
Mar 13, 2013
I am wondering why the maximum hydraulic gradline in my profile plot is not matching the maximum hydraulic grade levels reported in the report or excel spread sheets.
View 8 Replies
View Related
Oct 22, 2012
Has instances where you set your tolerance for the maximum triangle lenth to say 50m to reduce the amount of triangles along the edge that run at long distances. When I do this I end up with multiple surface holes and I'm not sure why as there are points in the area.
I thought well maybe it's because i should've reduced my max triangles first then added breaklines. Would this matter? I also thought I could add a line to the surface to fix the holes vs. deleting surface lines along the entire edge of a surface for many many miles.
View 9 Replies
View Related
Feb 12, 2013
I would like to have the leader arrow attached to the rim of the structure in profile view. Now they are attached along the side of the structure well below the rim. This is for the dragged labels. How can I adjust the arrowhead attachment point?
View 1 Replies
View Related
May 5, 2013
how can i set the smub of a structure at the crown of a pipe not at the invert?
View 3 Replies
View Related
Apr 11, 2013
I would like to add a wipeout to this structure label so I don't see the profile view grid lines. I want the wipeout to be the exact width and height of the label. I have tried numerous edits but can't seem to get it. What is the easiest/best way to add this wipeout?
View 9 Replies
View Related
Jan 28, 2013
I have a pipe network and a profile for it. Some of the structures have 2 inlet pipes. The pipe system more of less goes down a road, so every now and then there is a cross pipe into a structure. I have masking turned on under the structure style->profile setting. I want to see the cross pipe, so I found on here that all I need to do is under structure style->view direction (profile)->make Structure Pipe Outlines visible. I did that and still no cross pipe shows up. If I turn the masking off it is there.
View 5 Replies
View Related
Jun 7, 2012
See attached .pdf file.
I would like to delete the horizontal line (white line) from our sanitary profile structure. I have outlined it with a yellow cloud. I want to permanently delete it from our style. I can access the style in the Prospector but cannot figure out how to edit the block to delete the line in question.
View 2 Replies
View Related
Sep 6, 2013
Every structure for my Sanitary pipe network is showing up properly in the profile view except the last 2. They're showing as rectangles when they should have the cone on top. I've checked the properties of the correct ones and the incorrect ones and they're the same style. I looked at the parts and I couldn't see anything wrong with them. In the screenshot you can see that the 3 manholes on the left are the correct kind with the cone whereas the 2 on the right are just rectangles.
View 8 Replies
View Related
Feb 22, 2012
I've been having a problem with a pipe structure not showing up in a profile view. I have a single pipe network with everything (pipes and other structures) showing up in the profile when I select them, right-click, and click on "Draw Parts in Profile". Like I said, this works for all the other pipes and structures in the profile except one. When I select the structure individually and try to draw it into the profile, it still won't work. A friend told me to make sure that the structure is within the surface, and it is.
I'm using AutoCAD Civil 3D 2011.
View 6 Replies
View Related
Oct 3, 2012
profile structure doesn't update when changed. First, the rim to sump value will not change with sump defined by depth and trying to change the sump depth (going deeper and no rules exist). Second, change to define sump by elevation and the sump elevation changes and the grip changes to the correct elevation, but the part outline doesn't change. I've read where the part catalogue location should be updated. I did.
View 3 Replies
View Related
Jul 30, 2013
Water main pipe network profile labels for structures do not attach to the structure properly in C3D 2014 (this same label style works fine in all previous versions of the software, through the 2013 release). The labels come into the drawing at a northing of 0 rather than attaching to the structure itself. However, if you grip edit and reset the labels, they reset to their correct attachment point. Additionally, if you attempt to grip edit the profile labels with Ortho mode on, it moves the label back to a northing of 0. I've created a new block for the structure, but that does not resolve the issue.
I've included a link to a Chronicle video that demonstrates the label behavior. [URL] .......
View 3 Replies
View Related
May 7, 2013
I have an existing pipe network and a proposed pipe network. When I label a structure in my profile view, how do I combine the different network information? (Or do you usually have one network for both proposed and existing?)
For example, I have an existing pipe that will remain, but I will replace the structure and connect it to new pipes. On my label, I want to label proposed structure, pipes, and existing pipe using italics.
View 2 Replies
View Related
Oct 16, 2012
Suppose you have an existing structure that you are going to tie into with a proposed pipe.
We label existing structures with smaller text and a different color (as opposed to proposed labels)
Is there any way to label the structure where the one single proposed pipe text is a larger text size with a different color, as shown here?
View 2 Replies
View Related
Aug 20, 2013
Some of our structure styles for null structures are set to display as a block in profile. When we label these null structures in profile, the label dimension line extends to down to zero, way off the profile view. When I change the style to display the boundary of the null, the label pops back into place, but when I change the style back to a block, it will drop back to zero. I just upgraded to 2014 and this did not occur in 2010-2013. I've upgraded a drawing with existing profiles and also created a new pipe network and the results are the same. What changed in 2014 that would cause this?
View 4 Replies
View Related
Jul 9, 2013
how to show the inside diameter of structure in plan and profile view. Do I have to make sump and wall thicknesses 0 to do so?
View 5 Replies
View Related
Aug 3, 2013
I am create the stron network. I want structure profile elevation. How to create expression in structure reference alignment profile elevation.
View 9 Replies
View Related
Jul 25, 2013
Noticed this in R2013? Not bothering to check with 2014 yet as I don't really use it.I have three vports. TL is Profile view, TR is SV and other is 3d.
There seems to be slight difference between the pipes in the profile/sections compared with the Structure pipe crossing.
All styles are set for External walls, when swapped to internal this is still incorrect. All pipes are same size & part and are Horizontal. Sections / alignment is taken along centre of pipework.
View 5 Replies
View Related
Jan 29, 2013
Is it possible for a civil 3d structure to be displayed correctly in profile view when the alignment does not pass through the insertion point of the structure. See the attached screen capture.
The rectangular structure is a storage tank and there will be a pipe coming in on one end and the exit pipe will be on the adjacent side at the far end, just as the alignment shows - but the structure doesn't show correctly, or now how I expected.
View 3 Replies
View Related
Oct 21, 2013
I made an alignment of road, inserted with sample line, then i made a profile. But on the sample line on profile, there is not a data of height and lenght of profile. How to get those data in road profile. I can manually draw that, but i think there is an easier way?
View 1 Replies
View Related
Apr 16, 2012
I'm performing a static stress analysis on a benchframe. The benchframe is imported out of a STP file and I assume that's where the problems begin.
When I start the simulation, everything goes well. When I see the results, almost the whole part is blue, and only a really small part in a corner is shown red, with extremely high stresses.
The corner is actually not what I wanted to test, but it is messing up the other visible results because now I have to place probes all over the part to see the stresses (because the colors are calibrated with the high peak).
I have tried working with local mesh control and convergences, but I can't control the results in the small corner. I also tried rebuilding surfaces and adding fillets.
Is it possible to set a maximum stress, so that the other colors are visible in the important areas. It is not possible to exclude the corner from the simulation because it's part of a substantial part.
View 3 Replies
View Related
Nov 4, 2011
We use C3D 2012 (metric only) - We are attempting to customize our list of structures for Sanitary Sewers. The structure list shows sizes we do not use and we would like to modify them. However, when we try to select the "Inner Diameter" it displays a list of sizes that we can not seem to modify or add to.
I have looked at some of the XML files to try and modify or add new sizes (example: AeccStructConcentricCylinder_Metric.xml) , but they do not seem to be recognized even after I restart the program.
Here is what the file looks like:
<ColumnConstList desc="Inner Structure Diameter" dataType="float" unit="mm" name="SID" id="CCL1" visible="1" context="StructInnerDiameter" index="0">
<Item id="i0">1200.0000</Item>
<Item id="i1">1350.0000</Item>
<Item id="i2">1500.0000</Item>
<Item id="i3">1800.0000</Item>
<Item id="i4">2050.0000</Item>
<Item id="i5">2300.0000</Item>
<Item id="i6">2550.0000</Item>
I tried modifying the last line replacing 2550 with 3600.
I also tried adding a line <Item id="i7">3600.0000</Item>
I saved the XML file and restarted the program with nothing changing that I can see.
Looking for correct file(s) to edit so I can modify the LISTS that come up in the piping modules.
View 2 Replies
View Related
Feb 12, 2008
One good thing about null structures is the way they display in 3D. They cover that gap in the pipe segments. Can I steal that shape?
I am currently using a simple cylinder for water pipe "joints" and turning it off like most people do I think.
View 4 Replies
View Related