AutoCAD Civil 3D :: Labeling Pipe Structure On Profile With Multiple Networks?
May 7, 2013
I have an existing pipe network and a proposed pipe network. When I label a structure in my profile view, how do I combine the different network information? (Or do you usually have one network for both proposed and existing?)
For example, I have an existing pipe that will remain, but I will replace the structure and connect it to new pipes. On my label, I want to label proposed structure, pipes, and existing pipe using italics.
View 2 Replies
ADVERTISEMENT
Nov 19, 2012
Is there anyway to have the Pipe Networks tab of the Profile View Properties dialog box default to having "Show only parts drawn in profile view" selected automatically?
View 4 Replies
View Related
Mar 15, 2013
Is it possible to simultaneously create a pipe network with multiple pipes?
View 5 Replies
View Related
Jan 28, 2013
I have a pipe network and a profile for it. Some of the structures have 2 inlet pipes. The pipe system more of less goes down a road, so every now and then there is a cross pipe into a structure. I have masking turned on under the structure style->profile setting. I want to see the cross pipe, so I found on here that all I need to do is under structure style->view direction (profile)->make Structure Pipe Outlines visible. I did that and still no cross pipe shows up. If I turn the masking off it is there.
View 5 Replies
View Related
Sep 6, 2013
Every structure for my Sanitary pipe network is showing up properly in the profile view except the last 2. They're showing as rectangles when they should have the cone on top. I've checked the properties of the correct ones and the incorrect ones and they're the same style. I looked at the parts and I couldn't see anything wrong with them. In the screenshot you can see that the 3 manholes on the left are the correct kind with the cone whereas the 2 on the right are just rectangles.
View 8 Replies
View Related
Feb 22, 2012
I've been having a problem with a pipe structure not showing up in a profile view. I have a single pipe network with everything (pipes and other structures) showing up in the profile when I select them, right-click, and click on "Draw Parts in Profile". Like I said, this works for all the other pipes and structures in the profile except one. When I select the structure individually and try to draw it into the profile, it still won't work. A friend told me to make sure that the structure is within the surface, and it is.
I'm using AutoCAD Civil 3D 2011.
View 6 Replies
View Related
Jul 30, 2013
Water main pipe network profile labels for structures do not attach to the structure properly in C3D 2014 (this same label style works fine in all previous versions of the software, through the 2013 release). The labels come into the drawing at a northing of 0 rather than attaching to the structure itself. However, if you grip edit and reset the labels, they reset to their correct attachment point. Additionally, if you attempt to grip edit the profile labels with Ortho mode on, it moves the label back to a northing of 0. I've created a new block for the structure, but that does not resolve the issue.
I've included a link to a Chronicle video that demonstrates the label behavior. [URL] .......
View 3 Replies
View Related
Jul 25, 2013
Noticed this in R2013? Not bothering to check with 2014 yet as I don't really use it.I have three vports. TL is Profile view, TR is SV and other is 3d.
There seems to be slight difference between the pipes in the profile/sections compared with the Structure pipe crossing.
All styles are set for External walls, when swapped to internal this is still incorrect. All pipes are same size & part and are Horizontal. Sections / alignment is taken along centre of pipework.
View 5 Replies
View Related
Apr 20, 2011
Is there a way to label multiple structures/pipes at one time in profile view? We have tried selecting all at one time, right click and add label, but it only labels one of the structures/pipes.
View 4 Replies
View Related
Nov 4, 2011
We use C3D 2012 (metric only) - We are attempting to customize our list of structures for Sanitary Sewers. The structure list shows sizes we do not use and we would like to modify them. However, when we try to select the "Inner Diameter" it displays a list of sizes that we can not seem to modify or add to.
I have looked at some of the XML files to try and modify or add new sizes (example: AeccStructConcentricCylinder_Metric.xml) , but they do not seem to be recognized even after I restart the program.
Here is what the file looks like:
<ColumnConstList desc="Inner Structure Diameter" dataType="float" unit="mm" name="SID" id="CCL1" visible="1" context="StructInnerDiameter" index="0">
<Item id="i0">1200.0000</Item>
<Item id="i1">1350.0000</Item>
<Item id="i2">1500.0000</Item>
<Item id="i3">1800.0000</Item>
<Item id="i4">2050.0000</Item>
<Item id="i5">2300.0000</Item>
<Item id="i6">2550.0000</Item>
I tried modifying the last line replacing 2550 with 3600.
I also tried adding a line <Item id="i7">3600.0000</Item>
I saved the XML file and restarted the program with nothing changing that I can see.
Looking for correct file(s) to edit so I can modify the LISTS that come up in the piping modules.
View 2 Replies
View Related
Feb 12, 2008
One good thing about null structures is the way they display in 3D. They cover that gap in the pipe segments. Can I steal that shape?
I am currently using a simple cylinder for water pipe "joints" and turning it off like most people do I think.
View 4 Replies
View Related
Nov 28, 2012
Somehow I copied something and now when I open my drawing I have deplicate pipe networks with one being named something like Pipe Network and the 2nd being named Pipe Network(1). Pipe Network(1) does not show up in the toolspace. It has duplcated every pipe network in the drawing. I deleted all the pipe but when I close and reopen the drawing it comes right back. I've attched a pic. The single line is the original, the double line is network(1).
View 6 Replies
View Related
Jan 10, 2013
On a waterline that I am currently working on, we have existing utilities (gas, fiber, electric, etc.) surveyed and need to display those on our profile. Typically we will determine the crossing locations and offset those x' below the existing ground.
The problem I am having is that in a mile and a half of waterline, there are 100+ crossings. Creating a pipe out of each of those, applying the correct pipe type and display, naming the pipe network, etc, is too time consuming. It's faster to draw them on our profile manually. Also, with 100+ pipe networks, it slows down the drawing considerably. And if we create data shortcuts, then we have to create a reference to 100's of pipe networks in our plan and profile sheets.
View 9 Replies
View Related
Jul 1, 2013
I have a drawing that started as a pipeline network and am trying to easily convert the pipes to polylines or something of the sort to export to shapefiles.
View 4 Replies
View Related
Aug 15, 2013
On my drawings when I want to edit a label, I click the label, the ribbon changes and gives me options for that label, I click "edit label group" then a dialog box for that label style pops up and gives me more options.
Same drawings on another employees workspace, after clicking the label the ribbon changes, "edit label group" is selected from the ribbon, the command line then asks to pick a label you would like to edit even though you already selected a label.
What is the issue here? Does a system variable need to be set to "1" instead of "0" somewhere?
View 2 Replies
View Related
Jul 23, 2013
I layed out a pressure netowrk horizontally using 6" pvc pipe. It includes some 45 degree bends and such and even some curved pipe. Now the engineer wants to adjust the alignment in the area of the curved pipe.
First of all the modify area in the ribbon on the plan layout tools for pressure pipe is an absolut joke. It lets me break a pipe (which deletes one end of it), move a pipe (but the attched pipes don't move), or slide a pipe (whatever that's supposed to do).
If I grip edit a curved pipe, this will not work. The curved and tangent pipes will now no longer be tangent to each other and when laying out an alignment on the pipe itself, the curves will not work correctly when going to stake it out.
View 2 Replies
View Related
Apr 12, 2011
I would like to show a pipe network structure on my section view. The catch- the structure is 10' away from my sample line. Is there any way to project structures onto section views? C3D 2011
Civil 3D 2012 SP4.0 Windows 7 Enterprise 64-bit
C3D 2014 SP1
Dell M6600, Core i7 @ 2.3GHz, 16 GB ram
Dell T3500 workstation, too much ram to post
View 9 Replies
View Related
Jul 24, 2012
I am having an issue with the pipe networks drawing the pipes incorrectly in the cross sections. Whenever there is a crossing pipe running parallel with a structure, the pipe shows as a large ellipse instead of showing the pipe walls.
Some of the pipes are not running exactly parallel with the sample line, but they are pretty close. I know in the profile view you can change a setting to make a pipe show as a pipe end or as a regular pipe. Is there a setting for the cross sections as well? If not how do I get the pipes to show correctly?
View 5 Replies
View Related
Jun 5, 2013
I have a 18' x 10' special structure where I'd like to be able to connect the pipes as shown to the structure but I'm not aware of any way to force the Connection point of the pipe to the desired location along the structure.
Normal behavior is to connect all pipes to the same insertion point or center of structure.how to go about maintaining pipe connection orientation to reflect the design requirements?
View 9 Replies
View Related
Aug 2, 2012
So I wanted to put my existing 2d linework for a water main into a pressure network. I have done quite a bit of reading about pressure networks and the lack of different pipe materials and apputenances to choose from. It seems as though the fittings are all there for the most part.
The way I understand it is the only pipe material that is shipped with C3D is Ductile Iron and if you want PVC or something else, you open the content catalog editor and change the dutile iron pipe to polyvinyl chloride (PVC). Am I on the right track here?
As far as appurtenances go, when I open up the Content Catalog Explorer there is nothing for hydrants, valves, wyes, etc...... Is the only thing I can show then bends?
View 2 Replies
View Related
Jul 19, 2013
I have been working on a site layout, and the engineers changed the final topo. I have imported a DEM file, and changes all of my pipe networks to reference this final grade. But all of the pipes I have placed do not reference this surface, but all of the networks do. Other than changing all of the pipes individually (which is what I have started to do through Pipe Properties) is there a quicker and easier way to have all of the pipes reference my new surface, and also is there a quicker way to apply my rules to this new surface other than the same way (through Pipe Properties changing my rules, and right click to apply rules).
View 3 Replies
View Related
Jun 20, 2012
Using Network Layout Tools, can you attach a pipe to a structure in a different Pipe Network? 2013 Civil 3D
View 6 Replies
View Related
Jan 10, 2013
I have created a complicated 3D utilities model using pipe networks. All the clashes have been ironed out, the 3D DWF looks great when rotated, the client is happy. Now It is time to hand it over to the contractor to build. He hasn't got Civil 3D and isn't going to get get it. He either want's the information as an x,y,z, text format or a 3d polyline. I cannot see anyway of doing this with the tools available.
View 9 Replies
View Related
Feb 1, 2012
We are in the process of updating our pipe network structure label styles. The styles are displaying the inverts in a random order (Please see caption) & we'd like to show the inverts in descending order from highest pipe as first text string & lowest pipe as bottom text string. Is there a way to globally tell civil 3d to always use a descending invert order? Only fix we've found is to disconnect & reconnect the parts in order to adjust invert order.
C3D 2012 SP3 & C3D 2014 SP1
Win 7 Professional 64 Bit
View 6 Replies
View Related
Apr 2, 2012
Another collaboration question so you have a compressed design program and want the drainage to be designed while the finshed surface is yet to be completed.
View 5 Replies
View Related
Sep 9, 2013
I have designed a pipe network in Civil 3D 2013, first I created a rule set for both structures and pipes, then I created a parts list, next I built my network.
Where more than two pipes connected to one structure, I found 'applyrules' couldn't align everything appropriately, so I had to manually amend the levels in 3D to ensure the pipes connected correctly (soffit to soffit / top invert to top invert).
My problem is that after doing all this, the surface model has been amended! I have changed the reference surface in the network properties and in the vista. The rim height of my structures seems to have been adjusted in the most part but my pipes have not.
In areas where the surface has gone down, my minimum cover is violated. Is there a way to move the pipes back down to minimum cover, without using 'applyrules', as using that command would change the gradients to the minimum, some gradients have changed during my manual adjustments.
Furthermore, where the surface model has reduced in level significantly, my pipes are now above the surface and the manhole has stayed there too.
View 1 Replies
View Related
Dec 24, 2013
How Autodesk came up with the wall thicknesses for pipes in their parts lists under pipe networks in Civil 3D? I found that for DIP the wall thicknesses for pipes was way greater than anything commercially available; and that for PVC the wall thicknesses were way thinner than what's commercially available.
Are most client's modifying these lists to conform to pipe specifications or ignoring these discrepancies?
View 1 Replies
View Related
Jul 16, 2013
I need a way for 2 users to work on a pipe network at the same time. I was thinking about creating Data Shortcuts, but I’m looking for a better way to accomplish this. For example, can I export a pipe network created by another user into a master file? (which contains all my networks consolidated together). I want to work on one part of the network while another user works on another part of the network then combine into a single file so that I reference everything into our P&P sheets.
View 5 Replies
View Related
Sep 26, 2013
Any way to label a pipe part way between structures? I would like to be able to label a sanitary line where a service ties in with the main line invert.
C3D 2013
View 7 Replies
View Related
Jun 11, 2013
I have a drainage model, the data for which has been imported from microdrainage into Civil3d (.sws file) .
The engineer working on the project is playing around with the Invert and Cover levels so I reload the same updated .sws file into my model almost daily expecting the information shown in the labels of the pipes and manholes to simply change. Instead mine seem to disappear and I have to relabel the whole network again.
This wouldn't be much of a problem because labeling only takes a few minutes but with this particular scheme, the client wants the labels shown in a box with a leader. When I relabel, the boxes automatically snap to the center of the manholes without a leader and i then have to drag each one away from the manhole to get the leader to show up.
View 7 Replies
View Related
Apr 26, 2013
I created a pipe network from a object (alignment wLpolyline) I want to set my inverts at the inside edge
of my SDMH not the center. I go into Edit Pipe Networks then the vista (table). I don't see a option to do that.
Is there a setting in the SDMH structure style or somewhere else?
As an example I come in at 6250.0 at inside a 48" MH and go out at 6251.0 at other side of MH.
I wanted to use a catch basin that shows the depressed curb & lip like the one in the Pipe Network Video
but it not in my parts Library even when I create a full parts list it still isn't there. Is ther a way to go on line and download part structures?
View 2 Replies