AutoCAD Civil 3D :: Combine Pipe Networks From Separate Files Into A Single File
Jul 16, 2013
I need a way for 2 users to work on a pipe network at the same time. I was thinking about creating Data Shortcuts, but I’m looking for a better way to accomplish this. For example, can I export a pipe network created by another user into a master file? (which contains all my networks consolidated together). I want to work on one part of the network while another user works on another part of the network then combine into a single file so that I reference everything into our P&P sheets.
View 5 Replies
ADVERTISEMENT
Jul 19, 2013
I have been working on a site layout, and the engineers changed the final topo. I have imported a DEM file, and changes all of my pipe networks to reference this final grade. But all of the pipes I have placed do not reference this surface, but all of the networks do. Other than changing all of the pipes individually (which is what I have started to do through Pipe Properties) is there a quicker and easier way to have all of the pipes reference my new surface, and also is there a quicker way to apply my rules to this new surface other than the same way (through Pipe Properties changing my rules, and right click to apply rules).
View 3 Replies
View Related
Dec 16, 2011
Just wondering, if I have several seperate idw files and I want to combine them into one master file, is this possible? Would be handy to have all my drawing on one file instead of the 30 or so seperate ones it will become.
Inventor 2014 PDS
View 2 Replies
View Related
Sep 24, 2013
Illustrator files don't show up in Acrobat file list when trying to combine files into a single pdf
View 9 Replies
View Related
Nov 28, 2012
Somehow I copied something and now when I open my drawing I have deplicate pipe networks with one being named something like Pipe Network and the 2nd being named Pipe Network(1). Pipe Network(1) does not show up in the toolspace. It has duplcated every pipe network in the drawing. I deleted all the pipe but when I close and reopen the drawing it comes right back. I've attched a pic. The single line is the original, the double line is network(1).
View 6 Replies
View Related
Jan 10, 2013
On a waterline that I am currently working on, we have existing utilities (gas, fiber, electric, etc.) surveyed and need to display those on our profile. Typically we will determine the crossing locations and offset those x' below the existing ground.
The problem I am having is that in a mile and a half of waterline, there are 100+ crossings. Creating a pipe out of each of those, applying the correct pipe type and display, naming the pipe network, etc, is too time consuming. It's faster to draw them on our profile manually. Also, with 100+ pipe networks, it slows down the drawing considerably. And if we create data shortcuts, then we have to create a reference to 100's of pipe networks in our plan and profile sheets.
View 9 Replies
View Related
Jul 1, 2013
I have a drawing that started as a pipeline network and am trying to easily convert the pipes to polylines or something of the sort to export to shapefiles.
View 4 Replies
View Related
Mar 15, 2013
Is it possible to simultaneously create a pipe network with multiple pipes?
View 5 Replies
View Related
Aug 15, 2013
On my drawings when I want to edit a label, I click the label, the ribbon changes and gives me options for that label, I click "edit label group" then a dialog box for that label style pops up and gives me more options.
Same drawings on another employees workspace, after clicking the label the ribbon changes, "edit label group" is selected from the ribbon, the command line then asks to pick a label you would like to edit even though you already selected a label.
What is the issue here? Does a system variable need to be set to "1" instead of "0" somewhere?
View 2 Replies
View Related
Jul 23, 2013
I layed out a pressure netowrk horizontally using 6" pvc pipe. It includes some 45 degree bends and such and even some curved pipe. Now the engineer wants to adjust the alignment in the area of the curved pipe.
First of all the modify area in the ribbon on the plan layout tools for pressure pipe is an absolut joke. It lets me break a pipe (which deletes one end of it), move a pipe (but the attched pipes don't move), or slide a pipe (whatever that's supposed to do).
If I grip edit a curved pipe, this will not work. The curved and tangent pipes will now no longer be tangent to each other and when laying out an alignment on the pipe itself, the curves will not work correctly when going to stake it out.
View 2 Replies
View Related
Nov 19, 2012
Is there anyway to have the Pipe Networks tab of the Profile View Properties dialog box default to having "Show only parts drawn in profile view" selected automatically?
View 4 Replies
View Related
Apr 12, 2011
I would like to show a pipe network structure on my section view. The catch- the structure is 10' away from my sample line. Is there any way to project structures onto section views? C3D 2011
Civil 3D 2012 SP4.0 Windows 7 Enterprise 64-bit
C3D 2014 SP1
Dell M6600, Core i7 @ 2.3GHz, 16 GB ram
Dell T3500 workstation, too much ram to post
View 9 Replies
View Related
Jul 24, 2012
I am having an issue with the pipe networks drawing the pipes incorrectly in the cross sections. Whenever there is a crossing pipe running parallel with a structure, the pipe shows as a large ellipse instead of showing the pipe walls.
Some of the pipes are not running exactly parallel with the sample line, but they are pretty close. I know in the profile view you can change a setting to make a pipe show as a pipe end or as a regular pipe. Is there a setting for the cross sections as well? If not how do I get the pipes to show correctly?
View 5 Replies
View Related
Jun 5, 2013
I have a 18' x 10' special structure where I'd like to be able to connect the pipes as shown to the structure but I'm not aware of any way to force the Connection point of the pipe to the desired location along the structure.
Normal behavior is to connect all pipes to the same insertion point or center of structure.how to go about maintaining pipe connection orientation to reflect the design requirements?
View 9 Replies
View Related
Aug 2, 2012
So I wanted to put my existing 2d linework for a water main into a pressure network. I have done quite a bit of reading about pressure networks and the lack of different pipe materials and apputenances to choose from. It seems as though the fittings are all there for the most part.
The way I understand it is the only pipe material that is shipped with C3D is Ductile Iron and if you want PVC or something else, you open the content catalog editor and change the dutile iron pipe to polyvinyl chloride (PVC). Am I on the right track here?
As far as appurtenances go, when I open up the Content Catalog Explorer there is nothing for hydrants, valves, wyes, etc...... Is the only thing I can show then bends?
View 2 Replies
View Related
Jan 10, 2013
I have created a complicated 3D utilities model using pipe networks. All the clashes have been ironed out, the 3D DWF looks great when rotated, the client is happy. Now It is time to hand it over to the contractor to build. He hasn't got Civil 3D and isn't going to get get it. He either want's the information as an x,y,z, text format or a 3d polyline. I cannot see anyway of doing this with the tools available.
View 9 Replies
View Related
Feb 1, 2012
We are in the process of updating our pipe network structure label styles. The styles are displaying the inverts in a random order (Please see caption) & we'd like to show the inverts in descending order from highest pipe as first text string & lowest pipe as bottom text string. Is there a way to globally tell civil 3d to always use a descending invert order? Only fix we've found is to disconnect & reconnect the parts in order to adjust invert order.
C3D 2012 SP3 & C3D 2014 SP1
Win 7 Professional 64 Bit
View 6 Replies
View Related
Apr 2, 2012
Another collaboration question so you have a compressed design program and want the drainage to be designed while the finshed surface is yet to be completed.
View 5 Replies
View Related
May 7, 2013
I have an existing pipe network and a proposed pipe network. When I label a structure in my profile view, how do I combine the different network information? (Or do you usually have one network for both proposed and existing?)
For example, I have an existing pipe that will remain, but I will replace the structure and connect it to new pipes. On my label, I want to label proposed structure, pipes, and existing pipe using italics.
View 2 Replies
View Related
Sep 9, 2013
I have designed a pipe network in Civil 3D 2013, first I created a rule set for both structures and pipes, then I created a parts list, next I built my network.
Where more than two pipes connected to one structure, I found 'applyrules' couldn't align everything appropriately, so I had to manually amend the levels in 3D to ensure the pipes connected correctly (soffit to soffit / top invert to top invert).
My problem is that after doing all this, the surface model has been amended! I have changed the reference surface in the network properties and in the vista. The rim height of my structures seems to have been adjusted in the most part but my pipes have not.
In areas where the surface has gone down, my minimum cover is violated. Is there a way to move the pipes back down to minimum cover, without using 'applyrules', as using that command would change the gradients to the minimum, some gradients have changed during my manual adjustments.
Furthermore, where the surface model has reduced in level significantly, my pipes are now above the surface and the manhole has stayed there too.
View 1 Replies
View Related
Sep 26, 2013
We have Civil 3D 2013 (and 14). We need to create an ArchGIS file that includes pipe networks created with C3D, pavement and building which are polylines. export from C3D to shp file, or import dwg into ArchGIS. Since no one here has worked is familiar with map where would be a good place to start looking for information on accomplishing this task.
View 3 Replies
View Related
Dec 24, 2013
How Autodesk came up with the wall thicknesses for pipes in their parts lists under pipe networks in Civil 3D? I found that for DIP the wall thicknesses for pipes was way greater than anything commercially available; and that for PVC the wall thicknesses were way thinner than what's commercially available.
Are most client's modifying these lists to conform to pipe specifications or ignoring these discrepancies?
View 1 Replies
View Related
Apr 26, 2013
I created a pipe network from a object (alignment wLpolyline) I want to set my inverts at the inside edge
of my SDMH not the center. I go into Edit Pipe Networks then the vista (table). I don't see a option to do that.
Is there a setting in the SDMH structure style or somewhere else?
As an example I come in at 6250.0 at inside a 48" MH and go out at 6251.0 at other side of MH.
I wanted to use a catch basin that shows the depressed curb & lip like the one in the Pipe Network Video
but it not in my parts Library even when I create a full parts list it still isn't there. Is ther a way to go on line and download part structures?
View 2 Replies
View Related
Jan 29, 2012
Can the Plot command be used to combine multiple drawing views into a single DWF file?
View 1 Replies
View Related
Aug 15, 2013
I have a Storm pipe network for a subdivision. All of the pipe are on the same layer, using the pipe style. For some reason, only 1 of 68 pipes will display through my viewports. All of the layers within the pipe style are thawed in my viewports, as well as the layer the pipes themselves are on.
Further, when I go back to an archived file from a few days ago, all the pipes are also on the same layers and styles, and all pipes display as they should through all viewports. There seems to be no rhyme or reason for this. I am not sure what could have changed as I didn't knowing adjust anything with the pipe networks since archiving a few days ago
View 5 Replies
View Related
Nov 30, 2012
I have 10 separate drawing files that I want to combine into one drawing and I want each drawing to be on a separate layout.I want to end up with one drawing with 10 layout tabs each containing the graphics from one drawing.Each drawing has one layout with the graphics on it.No fancy paper space / model space stuff.No viewport scaling.
I thought this could be done via Design Center but I've never used that.
View 6 Replies
View Related
Aug 29, 2012
Is there a command to combine two 3d polylines into a single polyline? Either combine, take the mean between the two lines, or draw a third line at the mid distance between the two original lines?
The lines are created (in a .dxf) by a GPS unit in the field, and represent tracks needing to be mapped. Typically we would drive out a track and then drive back on the same track; this gives me two 3d polylines. Because of GPS errors it better practice to log the roads/ tracks twice. The lines can have from 2000 to 10000 vertices, so manually drawing is not an option.
View 4 Replies
View Related
Jul 29, 2004
Is there a way to combine all the ASL files in to one ASL file?
View 1 Replies
View Related
Dec 2, 2008
WINDOWS
CS2
PSD
I have two separate path in the paths window.
Can I combine them together into one path?
View 2 Replies
View Related
Jun 26, 2012
Save PSD File of Social Icons to Separate PNG image files for each file
View 7 Replies
View Related
Nov 21, 2012
New user of Photoshop Elements Organizer 11. I have been labelling hundreds of people using the facial recognition feature in the organizer. On reviewing them I find occasionally 2 stacks with the same person, likely caused by spelling errors. Even if I change the name to match the correctly spelled people stack, the 2 stacks remain separate. How do I combine them into a single people stack?
View 4 Replies
View Related