AutoCAD Civil 3D :: Wall Thicknesses For Pipes In Parts Lists In Pipe Networks
Dec 24, 2013
How Autodesk came up with the wall thicknesses for pipes in their parts lists under pipe networks in Civil 3D? I found that for DIP the wall thicknesses for pipes was way greater than anything commercially available; and that for PVC the wall thicknesses were way thinner than what's commercially available.
Are most client's modifying these lists to conform to pipe specifications or ignoring these discrepancies?
View 1 Replies
ADVERTISEMENT
Mar 15, 2013
Is it possible to simultaneously create a pipe network with multiple pipes?
View 5 Replies
View Related
Nov 28, 2012
Somehow I copied something and now when I open my drawing I have deplicate pipe networks with one being named something like Pipe Network and the 2nd being named Pipe Network(1). Pipe Network(1) does not show up in the toolspace. It has duplcated every pipe network in the drawing. I deleted all the pipe but when I close and reopen the drawing it comes right back. I've attched a pic. The single line is the original, the double line is network(1).
View 6 Replies
View Related
Jan 10, 2013
On a waterline that I am currently working on, we have existing utilities (gas, fiber, electric, etc.) surveyed and need to display those on our profile. Typically we will determine the crossing locations and offset those x' below the existing ground.
The problem I am having is that in a mile and a half of waterline, there are 100+ crossings. Creating a pipe out of each of those, applying the correct pipe type and display, naming the pipe network, etc, is too time consuming. It's faster to draw them on our profile manually. Also, with 100+ pipe networks, it slows down the drawing considerably. And if we create data shortcuts, then we have to create a reference to 100's of pipe networks in our plan and profile sheets.
View 9 Replies
View Related
Jul 1, 2013
I have a drawing that started as a pipeline network and am trying to easily convert the pipes to polylines or something of the sort to export to shapefiles.
View 4 Replies
View Related
Aug 15, 2013
On my drawings when I want to edit a label, I click the label, the ribbon changes and gives me options for that label, I click "edit label group" then a dialog box for that label style pops up and gives me more options.
Same drawings on another employees workspace, after clicking the label the ribbon changes, "edit label group" is selected from the ribbon, the command line then asks to pick a label you would like to edit even though you already selected a label.
What is the issue here? Does a system variable need to be set to "1" instead of "0" somewhere?
View 2 Replies
View Related
Jul 23, 2013
I layed out a pressure netowrk horizontally using 6" pvc pipe. It includes some 45 degree bends and such and even some curved pipe. Now the engineer wants to adjust the alignment in the area of the curved pipe.
First of all the modify area in the ribbon on the plan layout tools for pressure pipe is an absolut joke. It lets me break a pipe (which deletes one end of it), move a pipe (but the attched pipes don't move), or slide a pipe (whatever that's supposed to do).
If I grip edit a curved pipe, this will not work. The curved and tangent pipes will now no longer be tangent to each other and when laying out an alignment on the pipe itself, the curves will not work correctly when going to stake it out.
View 2 Replies
View Related
Nov 19, 2012
Is there anyway to have the Pipe Networks tab of the Profile View Properties dialog box default to having "Show only parts drawn in profile view" selected automatically?
View 4 Replies
View Related
Apr 12, 2011
I would like to show a pipe network structure on my section view. The catch- the structure is 10' away from my sample line. Is there any way to project structures onto section views? C3D 2011
Civil 3D 2012 SP4.0 Windows 7 Enterprise 64-bit
C3D 2014 SP1
Dell M6600, Core i7 @ 2.3GHz, 16 GB ram
Dell T3500 workstation, too much ram to post
View 9 Replies
View Related
Jul 24, 2012
I am having an issue with the pipe networks drawing the pipes incorrectly in the cross sections. Whenever there is a crossing pipe running parallel with a structure, the pipe shows as a large ellipse instead of showing the pipe walls.
Some of the pipes are not running exactly parallel with the sample line, but they are pretty close. I know in the profile view you can change a setting to make a pipe show as a pipe end or as a regular pipe. Is there a setting for the cross sections as well? If not how do I get the pipes to show correctly?
View 5 Replies
View Related
Jun 5, 2013
I have a 18' x 10' special structure where I'd like to be able to connect the pipes as shown to the structure but I'm not aware of any way to force the Connection point of the pipe to the desired location along the structure.
Normal behavior is to connect all pipes to the same insertion point or center of structure.how to go about maintaining pipe connection orientation to reflect the design requirements?
View 9 Replies
View Related
Aug 2, 2012
So I wanted to put my existing 2d linework for a water main into a pressure network. I have done quite a bit of reading about pressure networks and the lack of different pipe materials and apputenances to choose from. It seems as though the fittings are all there for the most part.
The way I understand it is the only pipe material that is shipped with C3D is Ductile Iron and if you want PVC or something else, you open the content catalog editor and change the dutile iron pipe to polyvinyl chloride (PVC). Am I on the right track here?
As far as appurtenances go, when I open up the Content Catalog Explorer there is nothing for hydrants, valves, wyes, etc...... Is the only thing I can show then bends?
View 2 Replies
View Related
Jul 19, 2013
I have been working on a site layout, and the engineers changed the final topo. I have imported a DEM file, and changes all of my pipe networks to reference this final grade. But all of the pipes I have placed do not reference this surface, but all of the networks do. Other than changing all of the pipes individually (which is what I have started to do through Pipe Properties) is there a quicker and easier way to have all of the pipes reference my new surface, and also is there a quicker way to apply my rules to this new surface other than the same way (through Pipe Properties changing my rules, and right click to apply rules).
View 3 Replies
View Related
Jan 10, 2013
I have created a complicated 3D utilities model using pipe networks. All the clashes have been ironed out, the 3D DWF looks great when rotated, the client is happy. Now It is time to hand it over to the contractor to build. He hasn't got Civil 3D and isn't going to get get it. He either want's the information as an x,y,z, text format or a 3d polyline. I cannot see anyway of doing this with the tools available.
View 9 Replies
View Related
Feb 1, 2012
We are in the process of updating our pipe network structure label styles. The styles are displaying the inverts in a random order (Please see caption) & we'd like to show the inverts in descending order from highest pipe as first text string & lowest pipe as bottom text string. Is there a way to globally tell civil 3d to always use a descending invert order? Only fix we've found is to disconnect & reconnect the parts in order to adjust invert order.
C3D 2012 SP3 & C3D 2014 SP1
Win 7 Professional 64 Bit
View 6 Replies
View Related
Apr 2, 2012
Another collaboration question so you have a compressed design program and want the drainage to be designed while the finshed surface is yet to be completed.
View 5 Replies
View Related
May 7, 2013
I have an existing pipe network and a proposed pipe network. When I label a structure in my profile view, how do I combine the different network information? (Or do you usually have one network for both proposed and existing?)
For example, I have an existing pipe that will remain, but I will replace the structure and connect it to new pipes. On my label, I want to label proposed structure, pipes, and existing pipe using italics.
View 2 Replies
View Related
Sep 9, 2013
I have designed a pipe network in Civil 3D 2013, first I created a rule set for both structures and pipes, then I created a parts list, next I built my network.
Where more than two pipes connected to one structure, I found 'applyrules' couldn't align everything appropriately, so I had to manually amend the levels in 3D to ensure the pipes connected correctly (soffit to soffit / top invert to top invert).
My problem is that after doing all this, the surface model has been amended! I have changed the reference surface in the network properties and in the vista. The rim height of my structures seems to have been adjusted in the most part but my pipes have not.
In areas where the surface has gone down, my minimum cover is violated. Is there a way to move the pipes back down to minimum cover, without using 'applyrules', as using that command would change the gradients to the minimum, some gradients have changed during my manual adjustments.
Furthermore, where the surface model has reduced in level significantly, my pipes are now above the surface and the manhole has stayed there too.
View 1 Replies
View Related
Jul 16, 2013
I need a way for 2 users to work on a pipe network at the same time. I was thinking about creating Data Shortcuts, but I’m looking for a better way to accomplish this. For example, can I export a pipe network created by another user into a master file? (which contains all my networks consolidated together). I want to work on one part of the network while another user works on another part of the network then combine into a single file so that I reference everything into our P&P sheets.
View 5 Replies
View Related
Apr 26, 2013
I created a pipe network from a object (alignment wLpolyline) I want to set my inverts at the inside edge
of my SDMH not the center. I go into Edit Pipe Networks then the vista (table). I don't see a option to do that.
Is there a setting in the SDMH structure style or somewhere else?
As an example I come in at 6250.0 at inside a 48" MH and go out at 6251.0 at other side of MH.
I wanted to use a catch basin that shows the depressed curb & lip like the one in the Pipe Network Video
but it not in my parts Library even when I create a full parts list it still isn't there. Is ther a way to go on line and download part structures?
View 2 Replies
View Related
Jun 18, 2013
I have a sanitary pipe network as well as a storm network. Now I need to extend the sanitary network one extra section. I go to edit the network, and choose the correct parts for structure and pipe from my catalog.
When I choose the draw; pipe only, structure only, pipes and structures it highlights like normal, and in the 'command' box it says to choose an insertion point. When I click an insertion point (either to an existing structure or a new place on the screen) the draw button that was highlighted becomes unclicked and nothing gets drawn. However this is only an issue when pipes only, or pipes and structures is picked. When I choose structures only It works fine.
View 1 Replies
View Related
Mar 4, 2013
I have created a new pipe network in a drawing that contained previously created networks. When the Network Layout Toolbar came up the dropdown for pipes was empty. If select a start point a network structure is placed there but at that point it stops, it won't allow entry of a second point. Last week IT rebuilt my Windows profile.
View 2 Replies
View Related
Nov 19, 2013
I oftenly do conception for parkings and always need to have the calculated rentention of water volume in the pipe network.is there a way to have that information with Civil 3d ?
Googled the subject and i only found a topic on trench's for the pipes ...
Cyberflow
Using : Autodesk Civil 3D 2012
OS : Windows 7 - 64 bit pro
View 3 Replies
View Related
Sep 19, 2012
Any way to create a parts list for HDPE pipes where instead of a manhole connecting different pipe sections will run continuously with coupling and elbows and it will connect to other pipe segments using wyes. Is this possible? The pipe should be able to bend either horizontally or vertically like any HDPE pipe. Any HDPE library?
My other question is once I have the layout of the pipe is it possible to calculate the trench excavation and backfilling?
View 3 Replies
View Related
Jan 28, 2013
Are there any particularly logical reasons this setting is included with Pipe Networks, but not Pressure Pipe Networks?
View 5 Replies
View Related
Nov 4, 2011
We use C3D 2012 (metric only) - We are attempting to customize our list of structures for Sanitary Sewers. The structure list shows sizes we do not use and we would like to modify them. However, when we try to select the "Inner Diameter" it displays a list of sizes that we can not seem to modify or add to.
I have looked at some of the XML files to try and modify or add new sizes (example: AeccStructConcentricCylinder_Metric.xml) , but they do not seem to be recognized even after I restart the program.
Here is what the file looks like:
<ColumnConstList desc="Inner Structure Diameter" dataType="float" unit="mm" name="SID" id="CCL1" visible="1" context="StructInnerDiameter" index="0">
<Item id="i0">1200.0000</Item>
<Item id="i1">1350.0000</Item>
<Item id="i2">1500.0000</Item>
<Item id="i3">1800.0000</Item>
<Item id="i4">2050.0000</Item>
<Item id="i5">2300.0000</Item>
<Item id="i6">2550.0000</Item>
I tried modifying the last line replacing 2550 with 3600.
I also tried adding a line <Item id="i7">3600.0000</Item>
I saved the XML file and restarted the program with nothing changing that I can see.
Looking for correct file(s) to edit so I can modify the LISTS that come up in the piping modules.
View 2 Replies
View Related
Apr 17, 2013
The 2013 .NET API exposes just 10 of the 22 PartDataFields for Pipe objects. WTh (Wall thickness) is not one of them so I'm attempting to get it via Late Binding. This lisp code works, where (vl-sel) is just a helper function to select an object and convert it to a vla-object:
(setq pdr (vlax-get (vl-sel) 'partdatarecord))(setq itm (vlax-invoke pdr 'find "WTh"))
to get the PartDataField. However, putting this into my C# code, it fails on the Find portion with an exception
//ps is a valid PartSize objectPartDataRecord pdr = ps.SizeDataRecord;PartDataField diafld = pdr.GetDataFieldBy(PartContextType.PipeInnerDiameter);object[] args = new object[1];
object acadobj = ps.AcadObject;
object pdrobj = acadobj.GetType().InvokeMember("PartDataRecord", System.Reflection.BindingFlags.GetProperty, null, acadobj, null);
args[0] = "WTh";
[code]....
View 3 Replies
View Related
Dec 7, 2012
I am using Civil 3D 2013. I work in an office where we have a few different flavors of Autocad (LT, MEP, regular vanilla AutoCAD etc...) and versions (2010 LT, 2011, 2012, 2013).
For the most part there isn't much inter-office drawing coordinate that has to happen, but there is the occasional project where multiple disciplines (Structural, Mechanical and Civil Site) have to share drawings.
The specific problem I am having is when I share my 2013 Civil 3D drawing with a user using 2011 MEP. He gets the typical rectangle for the proxy objects (in my case, my pipe networks for sanitary and storm drain). We've tried downloading and installing various object enablers, but there doesn't seem to be one for a 2013 to 2011 scenario. So I setup my parts to be on layers that he can just turn off. HOWEVER... the actual pipe network (not the structures, parts, labels etc... the network itself) ends up on layer 0. For this specific project, I do the old (ssget "x" '((8 . "0")) search to select all objects on layer 0, add those objects to a selection set (pselect), then in my modify objects dialog I filter for pipe networks, then change the layer to something other then 0.
While this is a workaround that works for me, what I really want to know is if there is a way that I can change the default layer that the network (again, not pipes, structures or text, the actual network) so I don't have to use the workaround. Any thoughts?
P.S. It's killing me that I had to create a new Autodesk login and now all my AutoCAD "street cred" is lost
"The source of expertise is not in the memorization of the minute details of a subject but in the thorough understanding of the fundamental concepts on which it is based."
View 9 Replies
View Related
Oct 3, 2013
I made a pipe network in one drawing, d-reffed it to another, drew parts in profile.
Then I realised that I needed to show the outside walls of some pipes in profile. We don't normally display them. And I found that the wall thickness was wrong. I eventually figured out how to edit the wall thickness, and I have it working right in the source drawing. (I had to swap parts to get it to update.) But the host drawing is not updating.
So if I go to pipe properties in the source drawing, it gives a wall thickness of 165mm (correct). If I go to the same pipe in the host drawing, and go the the pipe properties, the wall thickness is 75mm (wrong).
how to trigger an update? I've swapped parts back and forth to different sizes, synchronized, SetNetworkCatalog and done PartCatalogRegen in both drawings.
For background, read Edit wall thickness.
Civil 3D 2011, 32 bit
Win 7 Pro, 32 bit; Intel Core i5 @ 2.80GHz; 4GB RAM
View 7 Replies
View Related
Sep 26, 2013
We have Civil 3D 2013 (and 14). We need to create an ArchGIS file that includes pipe networks created with C3D, pavement and building which are polylines. export from C3D to shp file, or import dwg into ArchGIS. Since no one here has worked is familiar with map where would be a good place to start looking for information on accomplishing this task.
View 3 Replies
View Related
Nov 27, 2012
I have a user having an issue with drawing pipe networks. When they draw the pipe, the structure is not visible. A label shows up, and the structure can be found in the prospector, but is not editable in the plan view (see attached image).
I have a feeling it may be an issue with our pipe networks parts list and pipe catalog location. We have found an issue with our install that defaluts our pipes catalog to our local drives, but our parts list were created using a network drive. Several users have had an issue creating pipe networks when this has happened. However once we switched the pipe catalog to the netowrk drive the issue was resolved.
When we changed the pipe catalog location, it did not resolve the issues.FYI - I have tried the basics (layers on/thawed, pipe structure style layers on/thawed, audit and purge).We are using Civil 3D '09.
View 2 Replies
View Related