AutoCAD Civil 3D :: Pipe Network Toolbar Missing Pipes
Mar 4, 2013
I have created a new pipe network in a drawing that contained previously created networks. When the Network Layout Toolbar came up the dropdown for pipes was empty. If select a start point a network structure is placed there but at that point it stops, it won't allow entry of a second point. Last week IT rebuilt my Windows profile.
I am using Civil 3D 2013. I work in an office where we have a few different flavors of Autocad (LT, MEP, regular vanilla AutoCAD etc...) and versions (2010 LT, 2011, 2012, 2013).
For the most part there isn't much inter-office drawing coordinate that has to happen, but there is the occasional project where multiple disciplines (Structural, Mechanical and Civil Site) have to share drawings.
The specific problem I am having is when I share my 2013 Civil 3D drawing with a user using 2011 MEP. He gets the typical rectangle for the proxy objects (in my case, my pipe networks for sanitary and storm drain). We've tried downloading and installing various object enablers, but there doesn't seem to be one for a 2013 to 2011 scenario. So I setup my parts to be on layers that he can just turn off. HOWEVER... the actual pipe network (not the structures, parts, labels etc... the network itself) ends up on layer 0. For this specific project, I do the old (ssget "x" '((8 . "0")) search to select all objects on layer 0, add those objects to a selection set (pselect), then in my modify objects dialog I filter for pipe networks, then change the layer to something other then 0.
While this is a workaround that works for me, what I really want to know is if there is a way that I can change the default layer that the network (again, not pipes, structures or text, the actual network) so I don't have to use the workaround. Any thoughts?
P.S. It's killing me that I had to create a new Autodesk login and now all my AutoCAD "street cred" is lost
"The source of expertise is not in the memorization of the minute details of a subject but in the thorough understanding of the fundamental concepts on which it is based."
I have a sanitary pipe network as well as a storm network. Now I need to extend the sanitary network one extra section. I go to edit the network, and choose the correct parts for structure and pipe from my catalog.
When I choose the draw; pipe only, structure only, pipes and structures it highlights like normal, and in the 'command' box it says to choose an insertion point. When I click an insertion point (either to an existing structure or a new place on the screen) the draw button that was highlighted becomes unclicked and nothing gets drawn. However this is only an issue when pipes only, or pipes and structures is picked. When I choose structures only It works fine.
I oftenly do conception for parkings and always need to have the calculated rentention of water volume in the pipe network.is there a way to have that information with Civil 3d ?
Googled the subject and i only found a topic on trench's for the pipes ...
Cyberflow Using : Autodesk Civil 3D 2012 OS : Windows 7 - 64 bit pro
Civil 3D 2012. One structure in my pipe network is not following along when the network is data-referenced in to other plan drawings. The structure is present in the source drawing, and included in the network, along with the pipes that are connected to it. All other structures and pipes are operating fine.
Pipe network storm pipes: Fairly new to Civil3D and trying to set up parts list for the storm sewer pipe and would like the plan view to appear as it does currently. We use a polyline for centerline of pipe, similar to dashed linetype but line and space are the same, width set to pipe width.
I created pipe network for my storm drain project. I have located all the structures (manhole) to all angle point of my alignment as required. Also I "insert" manhole every 400' per local code requirements using the command "network layout tools; structures only. My problem is I couldn't find the tools how to trim the pipe that pass through the manhole. Please see attached pdf file.
I have pipe crossings shown in my profile. Only crossings (NO PROJECTIONS). So many elipises. I want to label them. Setting the label style at the pipe network does not work (will not override whatever label style was assigned at the pipe creation). I have accepted this (although it sucks).
Now, to get around it, I go Pipe>Add Label>Add Pipe Network Label. Label type is "Entire Network Profile". When I do this, it labels not only the crossings but all projections. So I have a million labels chilling out in space, where I have no crossing.
How Autodesk came up with the wall thicknesses for pipes in their parts lists under pipe networks in Civil 3D? I found that for DIP the wall thicknesses for pipes was way greater than anything commercially available; and that for PVC the wall thicknesses were way thinner than what's commercially available.
Are most client's modifying these lists to conform to pipe specifications or ignoring these discrepancies?
I have multiple profile views with a pipe network. In a number of cases, I have a pipe that extends to the end of one profile view and continues on the next. I can label the pipe on one profile but not on the other. Is there a way to add two labels to the same pipe - one label on one profile view and another label on the other profile?
I have lost the ability to create a pipe network in a single drawing. Sorta. I can create a pipe network, and label it, and see it in my toolspace, but it won't display it for any style in any format. I can bring in a data reference and label those, but can not see pipe or structure outlines or anything to that end. I have tried to recover, audit, purge. I am at the end, currently creating the pipe network, data referencing it in, and then just drawing lines between the labels.
I have created a pressure pipe network (Plan view) from own created pipes and fittings, try to create an alignment from the network but C3D tells me that the selected network part has no connected parts?
How would I connect the network in order to create an alignment? (the pipe network has got a command to do that)
I have a drainage model, the data for which has been imported from microdrainage into Civil3d (.sws file) .
The engineer working on the project is playing around with the Invert and Cover levels so I reload the same updated .sws file into my model almost daily expecting the information shown in the labels of the pipes and manholes to simply change. Instead mine seem to disappear and I have to relabel the whole network again.
This wouldn't be much of a problem because labeling only takes a few minutes but with this particular scheme, the client wants the labels shown in a box with a leader. When I relabel, the boxes automatically snap to the center of the manholes without a leader and i then have to drag each one away from the manhole to get the leader to show up.
I'm creating a utility template. Earlier in the day, I'm able to assign pipe and structure rules to a network and create the network based on these rules. Within the past 30 minutes, however, it completely ignores the pipe and structure rules while creating the network.
I make sure there is a surface assigned to the network. I make sure the pipe rules are set correctly in the parts list. I'm using no null structures. NOTHING HAS CHANGED EXCEPT THE POSITION OF THE MINUTE AND HOUR HANDS ON THE CLOCK! It's like the Civil 3D went out to lunch and forgot to tell me that it's going to lunch.
-Civil 3D 2012 -intel Core i7 2.4 GHz -8 GB of RAM Windows 7 64-bit Fred -Civil 3D 2013 sp2 -Windows 7 64-bit -Intel i7 Dual Core with 2.40 GHz -8 GB of RAM -AMD Radeon HD 6770M -Civil 3D user since 2007
I have a user having an issue with drawing pipe networks. When they draw the pipe, the structure is not visible. A label shows up, and the structure can be found in the prospector, but is not editable in the plan view (see attached image).
I have a feeling it may be an issue with our pipe networks parts list and pipe catalog location. We have found an issue with our install that defaluts our pipes catalog to our local drives, but our parts list were created using a network drive. Several users have had an issue creating pipe networks when this has happened. However once we switched the pipe catalog to the netowrk drive the issue was resolved.
When we changed the pipe catalog location, it did not resolve the issues.FYI - I have tried the basics (layers on/thawed, pipe structure style layers on/thawed, audit and purge).We are using Civil 3D '09.
We are having trouble with one of our C3D 2013 seats crashing (giving a fatal error) when trying to edit or do anything with a pipe network. The drawings work fine on other computers. I am trying to keep from having to remove and reinstall the software.
I am working on an existing Pipe Network. I have a location where I have already placed a pipe and filled in the correct parameters for this pipe. But I realize now that there is a concrete headwall near the end of the pipe. So I was trying to insert the structure at the midpoint of a line I have created for OSNAP reasons so it would create the structure at the specified location. The problem is when I move the structure to create at this location, the "Break Pipe Marker" goes away and only shows when I am at a different location along the pipe. So I wanted to see if there was a command or feature to use to tell the software I want to place this structure at a specified location along this one section of pipe.
I wanted to see what my options were. I know I can grab one end of the pipe and move it to the location and then add the structure and pipe from there. But I did this insertion under different circumstances and it broke the pipe into 2 sections while still keeping the same and adding a (1) after it, which is pretty useful when reading printouts and showing that this is actually one pipe instead of 2 pipes.
I can design a network of open ditches and pipes in Storm and Sanitary Analyzes to handle the flows required but when I export them back into Civil 3D the open ditches disappears. How do I add open ditches to the pipe network?
I have a network that I showed in a profile view and, to creat my proposed pipes network I simply copied the pipes and structures and used network split.
Now I have two networks, but when I project those pipes and structures into a profile they are not visible.
If I check the profile view properties and look at the pipe networks tab, all the pipes are shown as drawn.
i am currently using civil 3d 2012. I am having issues with pipe networks and my data shortcuts. when i data shortcut a pipe network into another file, sometimes my structures just disappear after saving and closing out, then reopening - like they were never there.
I have run into a problem with my Pipe Network data shortcut. When I am in a drawing that is referencing my Pipe Network not all of my structures are showing up. I confirmed this by going to the prospector tab/pipe networks/storm/structures. According to the list It is obvious that not all of my network structures are making it to the new drawing. I've double and triple checked the source drawing to make sure that all the structures actually exist and they do.
I've deleted the data shortcut and recreated it and still nothing.
I have an alignment that I want to create a pipe network from using the "Create pipe network from object" command. I am able to create the pipe network, but it only places a structure at the beginning of the alignment. How do I get it to create structures at all of the vertices?
I want to draw a water pipe network and i wanted to be 1.6 meter under the ground level. How to mange this my pipe network is PE material. I try to copy the profile and offset to -1,6 but i want to use the option of create pipe network and produce it in the profile view but how can i make the network follow the ground level profile ????
I need to add vertical curve to the network or something similar? Can i divide the pipes in the profile view by adding the structures direct to profile view.
How can I edit (graphically) my pipe network in plan view without losing my elevations every time I move a node? Every time I move a node I have to re-enter my invert elevations. Is there some way to "lock" my inverts? It may be useful to know my pipes have no structures linking them (water line).
If I have a pipe that spans between two profile views, is there a way to label the pipe in each profile view with only the lineal feet that is showing in that profile view?
Is there a way to have C3D calculate your cut generated from a pipe network? I have a site with storm, sewer, and water lines. All of which are on 3 seperate pipe networks. I also have my finished grade surface established.
I know you can get the volume difference between two surfaces (EG&FG) but you would think you could do this for the pipe networks as well...