One good thing about null structures is the way they display in 3D. They cover that gap in the pipe segments. Can I steal that shape?
I am currently using a simple cylinder for water pipe "joints" and turning it off like most people do I think.
We use C3D 2012 (metric only) - We are attempting to customize our list of structures for Sanitary Sewers. The structure list shows sizes we do not use and we would like to modify them. However, when we try to select the "Inner Diameter" it displays a list of sizes that we can not seem to modify or add to.
I have looked at some of the XML files to try and modify or add new sizes (example: AeccStructConcentricCylinder_Metric.xml) , but they do not seem to be recognized even after I restart the program.
We use a lot of Null Structures but then give them different descriptions. More often than not when I give them a description and then get out of the drawing, the next time I get back in it says "Null Structure" again. How can I keep the description the way I want it?
I know that "the right way" would be to have specific structures made for each of these items, but that doesn't seem to be a priority at my company..
Some of our structure styles for null structures are set to display as a block in profile. When we label these null structures in profile, the label dimension line extends to down to zero, way off the profile view. When I change the style to display the boundary of the null, the label pops back into place, but when I change the style back to a block, it will drop back to zero. I just upgraded to 2014 and this did not occur in 2010-2013. I've upgraded a drawing with existing profiles and also created a new pipe network and the results are the same. What changed in 2014 that would cause this?
I have drawn a pipe network with multiple concentric sturctures. I need to make them all eccentric now. Is there an easy quick way to do this, or do I have to redraw all of them. When I go to the properties, I cannot find an option that allows me to change this.
I have this block called gate valve. The base point is at the middle of the block. When I use this block as a style and insert it in profile it always places itself down low on the pipe. As you can see the grip is way above the top of the block and I have to move it into place anytime I use one. If I change the pipe inverts the gate valve block style lowers itself once again and I have to move it up into place. I have changed the base of the block but it makes no difference.
This is how the structure look in the object viewer. Notice the one on the right is the block that needs to be raised, however in the viewer it shows placed correctly.
Is possible to connect a pipe to a structure and not have in connected to the structure center?
I have some two-tiered structures that are 108" dia for the bottom section and 48" dia for the top section. The 48" top section is not centered I need my small 12"-15" pipes to connect to this section of the structure.
I have setup a reference surface for all of my structures and a sump depth of 0. All of the rims are being inserted about 1.6' above my reference surface. I am not able to grip any of the rims and lower them. It will not allow me to do so. Even if I grip the invert and make the structure extremely deep, I still cannot change the rim. I've had this problem in the past but don't recall how to correct or what I've done wrong in the setup.
I am working on an existing Pipe Network. I have a location where I have already placed a pipe and filled in the correct parameters for this pipe. But I realize now that there is a concrete headwall near the end of the pipe. So I was trying to insert the structure at the midpoint of a line I have created for OSNAP reasons so it would create the structure at the specified location. The problem is when I move the structure to create at this location, the "Break Pipe Marker" goes away and only shows when I am at a different location along the pipe. So I wanted to see if there was a command or feature to use to tell the software I want to place this structure at a specified location along this one section of pipe.
I wanted to see what my options were. I know I can grab one end of the pipe and move it to the location and then add the structure and pipe from there. But I did this insertion under different circumstances and it broke the pipe into 2 sections while still keeping the same and adding a (1) after it, which is pretty useful when reading printouts and showing that this is actually one pipe instead of 2 pipes.
we have serveral situations when we need to label both box culvert pipes and round rcp pipes on the same junction box label. what we cant do is have civil 3d differentiate between the two, it will either give us box labels or rcp labels but not both. we are using civil 3d 2011, does 2012 offer this feature and 2011 doesnt?
At the moment I'm trying to make a sewage pipe network, and I need something with a 7' diameter manhole. I'm trying to use Concentric Cylindrical Structures, and I'm not able to make or use a part size with an 84 in. diameter.
Is it possible for me to enter in my own value for that property, instead of having to use the pull-down menu?
I would like the arrowhead for the leader labaling my structure in a pipe network to attach to the outside edge of the structure. Right now it attaches to the middle of the structure and is covered by the block representing my structure.
I have a pipe network and a profile for it. Some of the structures have 2 inlet pipes. The pipe system more of less goes down a road, so every now and then there is a cross pipe into a structure. I have masking turned on under the structure style->profile setting. I want to see the cross pipe, so I found on here that all I need to do is under structure style->view direction (profile)->make Structure Pipe Outlines visible. I did that and still no cross pipe shows up. If I turn the masking off it is there.
I am using a structure table as a workaroumnd to get a dynamic point tab;e that also shows station offset. It shows Name, N, E, Elev, Sta, OS
I want the elevation shown in the table to be the elevation that was pulled from the specified surface when I set the structures, PLUS 2 inches.
I tried making them all Null Structures, but I am unable to edit the height of the structure - it wants to be 1.467 and won't change.
I am not even sure what i am doing since I don't use pipe stuff all that often.
My machine is hung on the Edit Networks part dialog, which I *think* is where I was trying set the height of a structure.
I tried creating a new structure and it wants half a million parameters for a simple cylinder, even though the ONLY thing I care about is the insertion point and adding 2 inches for the table.
C3D 2012 on 64bit Win 7 all up to date Dell Precision 7core 8GB RAM NVIDIA Quadro FX 1800M LDT/C3D user since release 12
I have a pipe network created that is shown in multiple drawings. I created labels for the structures showing Rims and Inverts. How to put the Rim info on a different layer than the Invert info? Right now the label has 3 different components...I feel like there has to be a way to put each component on different layers...
Is there ever a reason the option to add pipes or structures to an existing network would be grayed out? A colleague of mine called a week ago and wanted to add a manhole to the end of a pipe network where he had a clean out.
I didn't see his drawing but over the phone he tells me the button to add pipes and structures was grayed out. It wasn't giving him the option to add both or either or.
I need to make a structure label that defines the "PIPE FALL" for each incoming pipe. By "PIPE FALL", I mean the elevation difference between the bottom of the structure and the incoming pipe invert elevation.
Actually, I thought it was going to be pretty simple, just by doing:
I'm working in Civil 2012 and I'm putting in existing SD. I put in 2 DI's and a MH all on the same network (there is only one in my drawing) and I go to put in pipes and I click to connect to the first DI and then I'm kicked out of the command. What do I do?
Every structure for my Sanitary pipe network is showing up properly in the profile view except the last 2. They're showing as rectangles when they should have the cone on top. I've checked the properties of the correct ones and the incorrect ones and they're the same style. I looked at the parts and I couldn't see anything wrong with them. In the screenshot you can see that the 3 manholes on the left are the correct kind with the cone whereas the 2 on the right are just rectangles.
Apply the transformed utm coordinates to grid coordinates to a structure table. the point tables have a grid coordinate selection but the pipe structure table does not.
We set up our projects with a Topo sheet, a separate Design sheet, then a plot sheet with the drawing referenced in. The design sheet consist of basically all the design information unless this is a larger project, then the design components are given their own drawing file. Pretty industry standard, right?
The problem we are having is that the symbols are not scaling correctly for the plot sheets. I did some testing and the topo sheets are working as expected, but the "smart" pipes and structures are not from the design sheets. For the structures we are using a block for the plan view, and that is using the current drawing scale for the symbol size. But that is not carrying over to the plot sheet or viewport scale, it is locked to the scale of the saved Design drawing. So when plotting the project, half way through, people have to open the design drawing, change scale and resave to get the structures the right size for that sheet.
Do I have the structure style setup wrong? Shouldn't the symbol change to the plot sheets current view scale like a survey point?
I have played with making that plan block annotative but Civil 3D doesn't see a annotative block in the definition of a style.
I don't think that the network should have to be native to each plot sheet, but the only work around I have is to dataref the network into each plot sheet, and then have to freeze the xref's layers so there are not doubles.
Civil3D 2011 - How do I get pipe lengths to show up in a Structure Table? Can't find it in structures. I want to show the length of the pipes that is between two structures. The pipe slope is there but I can't find the length.
Also, comments. How do I get the Comments column in my table to actually display some sort of comments? Can I add a COMMENTS field to my structures?
I've been having a problem with a pipe structure not showing up in a profile view. I have a single pipe network with everything (pipes and other structures) showing up in the profile when I select them, right-click, and click on "Draw Parts in Profile". Like I said, this works for all the other pipes and structures in the profile except one. When I select the structure individually and try to draw it into the profile, it still won't work. A friend told me to make sure that the structure is within the surface, and it is.
I would like to know if it is possible to display the pipe inlet/outlet elevation in my structure label. It seems like it is not possible.It is possible to use the inlet/outlet elevation of the pipe in my pipe label however I would like to display it in my structure.
I have a pipe network, all the structures and pipes are connected properly. When I use the grip to move my structure, it will not move. I have to move both pipes then the manhole to relocate my structure. Shouldn't I be able to move the manhole and the pipes come with it? Instead I am having to make 3 grip edits and then reconnect the structures and pipes.
The PLS I work under inquired if the pipe and structure tables provided in our construction plans are able to be exported to excel. The only way I know how is to use the reports manage. The problem is, the provided Pipes reports don't contain all the data we are looking for. How do I modify, or create a new, Pipe report? It seems like it should be really easy to export the data to excel..