AutoCAD Civil 3D :: Pipe Structure Won't Show Up In Profile View
Feb 22, 2012
I've been having a problem with a pipe structure not showing up in a profile view. I have a single pipe network with everything (pipes and other structures) showing up in the profile when I select them, right-click, and click on "Draw Parts in Profile". Like I said, this works for all the other pipes and structures in the profile except one. When I select the structure individually and try to draw it into the profile, it still won't work. A friend told me to make sure that the structure is within the surface, and it is.
I'm using AutoCAD Civil 3D 2011.
View 6 Replies
ADVERTISEMENT
Sep 6, 2013
Every structure for my Sanitary pipe network is showing up properly in the profile view except the last 2. They're showing as rectangles when they should have the cone on top. I've checked the properties of the correct ones and the incorrect ones and they're the same style. I looked at the parts and I couldn't see anything wrong with them. In the screenshot you can see that the 3 manholes on the left are the correct kind with the cone whereas the 2 on the right are just rectangles.
View 8 Replies
View Related
Jul 9, 2013
how to show the inside diameter of structure in plan and profile view. Do I have to make sump and wall thicknesses 0 to do so?
View 5 Replies
View Related
Jun 6, 2012
I cannot find a way to only have pipes in profile view to only show the invert (bottom) of the pipe. All my pipes are running around the same elevation and the profile is pretty busy with both invert and crown of pipe shown.
View 2 Replies
View Related
Jan 28, 2013
I have a pipe network and a profile for it. Some of the structures have 2 inlet pipes. The pipe system more of less goes down a road, so every now and then there is a cross pipe into a structure. I have masking turned on under the structure style->profile setting. I want to see the cross pipe, so I found on here that all I need to do is under structure style->view direction (profile)->make Structure Pipe Outlines visible. I did that and still no cross pipe shows up. If I turn the masking off it is there.
View 5 Replies
View Related
Nov 4, 2013
I'm working with a structure profile label style and it seems like the only way to anchor the position of the label is based on offsets from the structure itself... Any way to position the label based on the top of the profile view, so that I could make all of my labels horizontally aligned above the profile view?
View 9 Replies
View Related
Aug 30, 2012
Civil3D 2011 - How do I get pipe lengths to show up in a Structure Table? Can't find it in structures. I want to show the length of the pipes that is between two structures. The pipe slope is there but I can't find the length.
Also, comments. How do I get the Comments column in my table to actually display some sort of comments? Can I add a COMMENTS field to my structures?
View 1 Replies
View Related
Jul 30, 2013
Water main pipe network profile labels for structures do not attach to the structure properly in C3D 2014 (this same label style works fine in all previous versions of the software, through the 2013 release). The labels come into the drawing at a northing of 0 rather than attaching to the structure itself. However, if you grip edit and reset the labels, they reset to their correct attachment point. Additionally, if you attempt to grip edit the profile labels with Ortho mode on, it moves the label back to a northing of 0. I've created a new block for the structure, but that does not resolve the issue.
I've included a link to a Chronicle video that demonstrates the label behavior. [URL] .......
View 3 Replies
View Related
May 7, 2013
I have an existing pipe network and a proposed pipe network. When I label a structure in my profile view, how do I combine the different network information? (Or do you usually have one network for both proposed and existing?)
For example, I have an existing pipe that will remain, but I will replace the structure and connect it to new pipes. On my label, I want to label proposed structure, pipes, and existing pipe using italics.
View 2 Replies
View Related
Jul 25, 2013
Noticed this in R2013? Not bothering to check with 2014 yet as I don't really use it.I have three vports. TL is Profile view, TR is SV and other is 3d.
There seems to be slight difference between the pipes in the profile/sections compared with the Structure pipe crossing.
All styles are set for External walls, when swapped to internal this is still incorrect. All pipes are same size & part and are Horizontal. Sections / alignment is taken along centre of pipework.
View 5 Replies
View Related
Feb 29, 2012
I have 7 manholes in my network, only 3 of them are visibile in the model tab though.
There is structure label on all of the manholes
I can use select similar to mark them and i get "Structure (7)".
I can even see them in the object viewer.
AutoCad 2011 & Civil3D 2011. Product Version 3.
EliteBook 8560w
Intel i7 CPU 2820QM @ 2.3GHz
8 GB RAM
NVIDIA Quadro 1000M
Windows 7 Enterprise 32 Bit
View 4 Replies
View Related
May 5, 2013
how can i set the smub of a structure at the crown of a pipe not at the invert?
View 3 Replies
View Related
May 15, 2012
I am using civil 3d 2012.
I have a network that I showed in a profile view and, to creat my proposed pipes network I simply copied the pipes and structures and used network split.
Now I have two networks, but when I project those pipes and structures into a profile they are not visible.
If I check the profile view properties and look at the pipe networks tab, all the pipes are shown as drawn.
View 7 Replies
View Related
Dec 6, 2013
I have a typical storm sewer pipe network in a drawing by itself with an alignment. I data referenced both of these into another drawing. I draw the pipe network in the profile view I created and the pipes that run with the road show up fine. Every once in awhile there is a lateral storm sewer pipe that runs across the road. When I draw these in the profile view they show up, but, only the pipes that are skewed to the alignment show up. If the pipe is perfectly perpendicular to the alignment it does not show up. I have two styles setup. One main one that shows the inner and outer pipe walls and another one for overrides for the crossing pipes and that stlye has crossing pipe walls turned on.
Why is it though only the skewed pipes show up as ellipses in my profile view but the perpendicular pipes do not?
View 2 Replies
View Related
Jan 29, 2013
Is it possible for a civil 3d structure to be displayed correctly in profile view when the alignment does not pass through the insertion point of the structure. See the attached screen capture.
The rectangular structure is a storage tank and there will be a pipe coming in on one end and the exit pipe will be on the adjacent side at the far end, just as the alignment shows - but the structure doesn't show correctly, or now how I expected.
View 3 Replies
View Related
Apr 25, 2012
I click on my pipe in profile. Right click and add label. I see nothing, no label. All layers on and un-frozen.
View 6 Replies
View Related
Feb 4, 2013
As it stands, if you view a pipe network in a profile view with no vertical exaggeration, you expect to see what is essentially an accurate long section in all directions. However, rather than being applied perpendicularly from the center line (or arguably the invert), diameter is applied strictly vertically.
Now, this made sense in the days of hand drafting when it was far easier in a vertically exaggerated profile view to simply measure the dimension vertically rather than determining how the exaggeration affects the perpendicular distance. But with the computer doing the measurements, is this really a problem anymore? I've debated that to some degree it's strange to consider that the crown of the pipe may be at a (slightly) different station than the invert, but this is simply fact in the field. And I've also thought that it's nice to be able simply measure vertically in an exaggerated profile, but I can't remember the last time I dug my scale out of the drawer.
All the theory aside, the real problem appears when you try to profile a vertical, or even a near-vertical, pipe. The fact that the diameter is applied vertically means that the vertical centerline is shifted the length of the pipe radius downward and upward. In other words, rather than seeing the invert and crown of the pipe, you just see one line, though it's really two lines on top of each other.
I wrote this off for the last 4 years of basic Pipe Networks because I acknowledge that storm/sanitary outside the building is rarely designed vertically, but with 2013's release of the Pressure Pipe Network, I really expected Autodesk to change the way the profile views represented pipes.
View 3 Replies
View Related
May 19, 2013
Need getting pipe top elevation in profile view data band? In labels it's possible to perform calculations via expressions. In data bands – not. Inablity to get pipe outside top elevation in profile view leads to dead end in my hunt for smooth workflow.
View 5 Replies
View Related
Dec 9, 2013
I have my alignment running up the page, it is the red line. I can show the profile of the pipes and structures that run with the alignment but I want to she the elevations of the crossing pipes, not just the circle in the structures where they cross but the elevation of the crossing structures and pipes, (str 102-103 and 104-105). Almost like a profile that is cut and looks north (up) instead of the cut looking east west.Can I turn my profile view or take a view at a certain station or do I need to make alignments that run east west to do this? I have included a pedicure for reference.
View 3 Replies
View Related
Feb 7, 2013
I created a pressure pipe with no bends since my alignment is fairly straight. However, I'm changing the elevations on the pipe using a combincation of the profile view snaps and elevation edits in the properties and it doesn't restrict my deflection to my deflection settings not does it add any bends.
Is this still a missing function in Pressure Networks? Or is there something I'm missing?
View 1 Replies
View Related
Nov 4, 2011
We use C3D 2012 (metric only) - We are attempting to customize our list of structures for Sanitary Sewers. The structure list shows sizes we do not use and we would like to modify them. However, when we try to select the "Inner Diameter" it displays a list of sizes that we can not seem to modify or add to.
I have looked at some of the XML files to try and modify or add new sizes (example: AeccStructConcentricCylinder_Metric.xml) , but they do not seem to be recognized even after I restart the program.
Here is what the file looks like:
<ColumnConstList desc="Inner Structure Diameter" dataType="float" unit="mm" name="SID" id="CCL1" visible="1" context="StructInnerDiameter" index="0">
<Item id="i0">1200.0000</Item>
<Item id="i1">1350.0000</Item>
<Item id="i2">1500.0000</Item>
<Item id="i3">1800.0000</Item>
<Item id="i4">2050.0000</Item>
<Item id="i5">2300.0000</Item>
<Item id="i6">2550.0000</Item>
I tried modifying the last line replacing 2550 with 3600.
I also tried adding a line <Item id="i7">3600.0000</Item>
I saved the XML file and restarted the program with nothing changing that I can see.
Looking for correct file(s) to edit so I can modify the LISTS that come up in the piping modules.
View 2 Replies
View Related
Feb 12, 2008
One good thing about null structures is the way they display in 3D. They cover that gap in the pipe segments. Can I steal that shape?
I am currently using a simple cylinder for water pipe "joints" and turning it off like most people do I think.
View 4 Replies
View Related
Dec 9, 2013
I clicked on a pressure pipe in profile view and selected "Edit Pressure Network in Profile...". The panel that came up has a button that says "Follow Surface". I did that and selected all of my pipe and entered 4 feet below surface for my water main and it put alot of deflections in my pressure pipes. How to remove the deflections?
View 2 Replies
View Related
Jul 30, 2011
If I have a Crescent Road (P - shape) where the Alignment returns to itself, when i draw pipe network parts in profile, the pipe network gets drawn wrong, ie. the tie-in structure at the intersection is drawn at the wrong station.
My understanding is that the structures will get drawn at the station closest perpendicularly to the alignment, so the structure is going to the end station as opposed to the beginning simply because the end segment of the alignment is closer.
Is there any way to make a structure use a different perpendicular station (without shortening the alignment)?I don't want to move alignment or structure.
View 8 Replies
View Related
Mar 2, 2012
We have a big piping job coming up and as Civil3d still lacks some of the labelling abilities we want in the profile view bands. I am updating some old vba that adds a profile line of the invert of a pipe network to a profile view effectively tracing along the bottom of the network like I know a lot of people do by hand.
My original code works on assuming that the start and end structure are at the start and end of the alignment in the revised code I want to allow for situations where this is not the case.
Leading to my question is there and easy way to find the distance a profile view part is drawn along the parent alignment or do I have look at writing my own function possibly extracting a polyline from the alignment and finding the distance using intersectionwith and distancefrom functions with the structure.
View 2 Replies
View Related
Dec 31, 2013
Using part builder, I created a new pipe part for an odd-sized CMP arch pipe. In plan view, the pipe looks good. At first glance, I thought the pipe was drawn correctly in a profile view, but I realized that the pipe was displayed with the invert located at the wrong place in the profile view. I thought this was because the insertion point of the new pipe part that I had made was placed at the incorrect location in part builder.
So, I swapped out the incorrect pipe size for another one that I knew was correct, and then deleted the incorrect pipe from the pipe parts list, and went back to part builder, and placed the insertion point at the invert of the pipe; then saved the edited pipe part, ran partcatalogregen, added the "corrected" pipe part to the pipe parts list and swapped in the new corrected pipe size to the pipe network. However, the pipe still displays incorrrectly on the profile view.
The pipe data is correct in the pipe properties: the invert is stated to be located at elevation 20. The overall height of the pipe , 38" (3.1667') is correctly displayed on the profile view. But the actual location of the pipe invert is not shown at the correct location, elevation 20, on the profile view.
View 4 Replies
View Related
Mar 21, 2013
I'm trying to add assign a Pipe Network to a profile view Band in Civil 3D 2011. I was using COM to add profiles to bands because I couldn't figure out how to do it in .NET. But when it comes to pipe networks I don't see how you can do that with COM. How the .NET implementation is supposed to work? Here's the code I have that works for COM, except for the pipe networks. I essentially need to assign the correct pipe network to the band.
public static void AddProfileToBand(this ProfileView profileView, ObjectId profObjId, List<BandItemInfo> bandStyleInfosFromSet, ObjectId profileBandSetId){
using (Transaction tr = Application.DocumentManager.MdiActiveDocument.TransactionManager.StartTransaction())
[code]....
View 1 Replies
View Related
May 7, 2012
Header says it all. For example, if I set a pipestyle to display the inside walls with linetype Continuous, it works ok in plan view, but not profile.
When I select the pipe top edit its style (right click context menu), it is in the Profile View, but the changes are happening in the plan view.
Where I should set it to display how I want in the profile view?
C3D 2012 on 64bit Win 7 all up to date
Dell Precision 7core 8GB RAM
NVIDIA Quadro FX 1800M
LDT/C3D user since release 12
View 2 Replies
View Related
Jun 20, 2012
Using Network Layout Tools, can you attach a pipe to a structure in a different Pipe Network? 2013 Civil 3D
View 6 Replies
View Related
Feb 12, 2013
Run profile on a self-intersecting street? The one I'm dealing with is a dead end 'P' shape. Logically, there are manholes in the intersection of the 'P', and logically to me, these structures need to show up in two places in the same profile view. Of course, C3D doesn't realize that I want a certain structure to show up twice, and I'm not sure how to communicate that information to it.
View 1 Replies
View Related
May 15, 2013
recommend a good way to indicate the location of cross section sample lines in a profile view (of same alignment) as vertical lines? the sample lines have been created at user defined locations from polylines, and do not follow a particular station order. my first thought was to use transparent command to draw line in profile view using station from plan view, but i have in excess of 100 cross sections, and that may be time consuming.
Civil 3D 2013 SP1, Win 7-64 bit
12GB RAM
View 2 Replies
View Related