AutoCAD Civil 3D :: Self-intersecting Alignment - How To Show Pipes In Profile View
Feb 12, 2013
Run profile on a self-intersecting street? The one I'm dealing with is a dead end 'P' shape. Logically, there are manholes in the intersection of the 'P', and logically to me, these structures need to show up in two places in the same profile view. Of course, C3D doesn't realize that I want a certain structure to show up twice, and I'm not sure how to communicate that information to it.
Is there a way (and I'm just missing it) to have a pipe from a pipe network only be shown 'cut-off', with the typical 'cut-off' shown on the profile view? see the screen shot of sketch of what I'm referring to.
How I have come to this question is through the process of trying to realistically show a hydrant in profile view. First off it it possible to create a completely vertical pipe in C3D? Also if you can, is it possible to show that in profile view? Basically, what I am trying to avoid is representing a fire hydrant pipe by creating some sort of custom cyclinder part in partbuilder. I have done this, but do not like the results.
Civil 3D 2013 SP2 | Win 7 64-bit SP1 Intel Core i5-2500 @ 3.30GHz, 8GB Ram | ATI Radeon HD 5450
Is there a way to label multiple structures/pipes at one time in profile view? We have tried selecting all at one time, right click and add label, but it only labels one of the structures/pipes.
I remember seeing an article or web cast on how to create a style to display a single line for a manhole. It may have been about using the parts create tool. But for the life of me, I can’t remember where I saw it.
Also I had created a style in C3D2007 to display the pipes in profile as a single line. This was done by drawing the flow arrow in a non printable colour over the top of the pipe.In C3D2008 this is no longer possible. So now what?
My colleague added parallel pipe networks and crossings to multiple SD profile views yesterday. Today, he came in, turned on AutoCAD, opened the drawing, and the parallel pipes and crossings were gone. The working folder had reset itself to nowhere so we reset the working folder and Data Shortcuts Folder, but that didn't bring them back. We can go into the profile view properties<pipe networks tab and turn the pipes and structures back on and override the styles, but that is basically redoing everything we did yesterday. Is there a way to avoid having to redo everything? Is there a way to avoid this from happening in the first place?
What do I draw the existing pipes as that will be under the surface that I'm profiling? I have the surveyed invert points I'm assuming that won't be polylines? how to get the pipe to show at the proper elevation on the profile?
I was wondering if after drawing an alignment, creating a profile, and profile view, is there a way I can mark items along the alignment so they could show up in the profile view. I am laying out a pipeline and want to have the profile display a marker for items such as tees, elbows, reducers and other items. The marker I would like to use will be something like the vertical style grade break markers.
Also on a side note, as each of these items will have a different name, is there a way that I can add these markers and then have each one with a unique name?
I imported Google earth surface (at eye alt 600m) to civil 3d 2012 and created an alignment of length 181m.
When I exported same alignment to Google earth , it showed the length as 190m ( the difference increases with increase in length of alignment) And also the profile view of the alignment in the Civil D & Google earth varies.
We are working together with another firm here in town. The are doing the road and we are doing the utilities. They have established the alignments and profiles. When I import them all the data comes in. For whatever reason I do not have their profile views so I create my own profile view and put their profiles in them.
When they send an updated .xml file of all the alignments and profiles, they import okay but my profile views disappear. I assume it's because in their .xml file that I import, there are no profile view defined.
Is there an options when you export and alignment to an .xml file that you can include the profile views with it as well? This way when I import them I would get them.
Is there anyway to display Alignment Station Offset Label at Profile View because sometimes i want to display where is the phisical noze location in profile view also my attached file display what i have in my label and how display my label in profile view.
Having a rough time with Pipe Networks! I am working an example from the Mastering C3D book (P. 371) as in the following steps:
1.Clicked SS structure(16)
2.Selected Create Alignment from Network on ribbon
3.Selected last structure(18), hit Enter
4.Changed options as needed in Create Align from Network - Create Profile and Profile View check box: Selected
5.Changed options and clicked Create Profile View
At this point the program pauses, then a dialog box trys to partially fill the screen but is all white then fades away as fast as it appeared and I'm stuck with a paperweight that beeps at me everytime I click the mouse, no panning or zooming response at this time. The command line is prompting me for the profile origin. I can switch to other apps and bring up TM and when I attempt to end C3D then it tells me that it can't because waiting for response. I can then cancel the prompt to save the drawing and C3D exits the active command and control is returned.
[URL]
Civil 3D 2013 SP 1, 64 bit Dell Precision T5600, 16 GB Win 7 Professional 64 bit Intel Xeon @ 2.0 GHz NVIDIA Quadro 4000
Is it possible for a civil 3d structure to be displayed correctly in profile view when the alignment does not pass through the insertion point of the structure. See the attached screen capture.
The rectangular structure is a storage tank and there will be a pipe coming in on one end and the exit pipe will be on the adjacent side at the far end, just as the alignment shows - but the structure doesn't show correctly, or now how I expected.
I cannot find a way to only have pipes in profile view to only show the invert (bottom) of the pipe. All my pipes are running around the same elevation and the profile is pretty busy with both invert and crown of pipe shown.
I've been having a problem with a pipe structure not showing up in a profile view. I have a single pipe network with everything (pipes and other structures) showing up in the profile when I select them, right-click, and click on "Draw Parts in Profile". Like I said, this works for all the other pipes and structures in the profile except one. When I select the structure individually and try to draw it into the profile, it still won't work. A friend told me to make sure that the structure is within the surface, and it is.
recommend a good way to indicate the location of cross section sample lines in a profile view (of same alignment) as vertical lines? the sample lines have been created at user defined locations from polylines, and do not follow a particular station order. my first thought was to use transparent command to draw line in profile view using station from plan view, but i have in excess of 100 cross sections, and that may be time consuming.
Is there a way for the program to automatically change profile elevations of intersecting roads.
Say for example i have two intersecting roads ROAD A and ROAD B.
On my ROAD A profile at station 0+300 i have a proposed road elevation of 9.5 On my ROAD B profile at station 0+000 (intersecting point) I have the same proposed road elevation of 9.5.
Now i change my ROAD A profile at station 0+300 to 10.3
Is there anyway to allow the program to automatically change my ROAD B profile elevations to 10.3
IF NOT--
and I have to use the Annotate > Add Labels > Profile View > .......................... labels,
Is there a way for those labels to link across the profiles such that , On my ROAD A profile at station 0+300 i put the label at the elevation of 9.5
On my ROAD B profile at station 0+000 (intersecting point) I have the same label at the elevation of 9.5
Now i change my ROAD A profile at station 0+300 to elevation of 10.3 then is there a way for it to automatically raise the ROAD B elevation label
So that I would know, without having to manually check through, that there is a discrepancy between those intersecting roads. So the real list of my query is whether I can link my alignments, profiles or annotation labels.
why when i mesure the pipe diam prependicular in profile its less than the accurat dimension of the pipe whoever i changed the profile vertical exaggeration to 1, it still wrong? when mesured virtical it is ok
I have two pipe networks and two profile views, one for storm and another for sanitary. I would like to show the crossing pipes on each of the profile views. When I select the profile view, add a pipe and change the style to crossing the style is change to crossing on the other profile view (ex. on sanitary profile view I set storm pipe 3 to crossing style, on the storm profile pipe 3 changes to crossing style and does not display). Isn't there a way to display the styles for pipes different in each profile view?
I have a profile with a couple of pipe networks in it. One of the pipes shown extends beyond the edge of the profile at some crazy angle. look at the picture for a better explanation.
How to do profiles in Civil3D and I have created a profile from the surface utilizing a miscellaneous alignment. I have also taken one 12"RCP and made it part of a network along with the catch basin and manhole at its start and end. When I click "draw parts in profile" it places both structures and the pipe, but in reality only a portion of the pipe crosses the alignment. I'd like to only display portions of pipes that cross the alignment at a fixed width form that alignment, say 2' to each side of it.
I have an alignment label that I normally use to show the PVI's of a profile in the plan view.
This is a little unusual, but in a specific case I wanted to design my profile at one alignment, but show it at another. I designed my swale profile in the pathway profile view and then superimposed the swale profile on the swale profile view. I then went back to the swale alignment to add these labels.
It's a no-go AFAICT. The only profile available for me to select for these labels is the original ground profile from the surface.
I’m wondering if there is a way to launch alignment grid view/alignment entities (attached) without the need to first launching “alignment”? This dialogue box is quite essential in editing the values of radius, degree of curvature and deflection angle for the selected curve.
When I try to make a pipe network the structures are visible but the pipes are not present. I thawed all layers with no success. This is a recent development because It was working last week.
In order to have a data band at the bottom of my profile label the station and invert of my sewer pipe I just created a profile along the pipe and then have a data band in my profile that labels that profile. I have that profile style set to not plot so this way I can leave it on all the time. This is all fine and well. I have labels every 100' that label the station and invert elevation but at times I want to label miscellaneous locations along my pipe such as a bend or something. How do I add an addition data band label to achieve this? Everything I have found only lets me have these labels at a specified increment set in the band style.
Is there a way for C3D 2013 to automatically hatch (with a style) in the profile view the area from the FG to top of pipes (Sanitary, Storm or Water). Currently we go old school with isolating the linework in the profile and hatching it manually. The interesting thing is the hatch still recognizes the grid in the profile view even though we've frozen the grid and other linework. AND we must put a line on the top of the pipe, or the hatching goes to the next "grid" of the profile.
Would be nice to get it to generate the hatch much the same way it does for the profile view with Cut area or Fill area or Multi boundaries.
I've got a weird problem with pipes in 2014. When I edit a pipe (right-click Pipe Properties) and make a change, when I press OK or Apply, the pipe SIZE changes? It's still listed as a 300mm PVC, but it's being represented as a 410mm? Look at the attached image. The storm (green) shoes a 300mm pipe and 375. The 375 is smaller? The pipe style (as you can see int he image, is set to display the inside pipe walls.
Nothing is unique here about the pipe sizes, this is a stock pipe catalog. But the size doesn't really change, only how the pipe is drawn in the profile. I've never seen something like this before. It measures .418m instead of .3m.