AutoCAD Civil 3D :: Change Alignment Reference In Profile View?
Sep 18, 2012I have a profile that references an alignment, I want to change the alignment that the profile view references, can this be done?
View 1 RepliesI have a profile that references an alignment, I want to change the alignment that the profile view references, can this be done?
View 1 RepliesI am create the stron network. I want structure profile elevation. How to create expression in structure reference alignment profile elevation.
View 9 Replies View RelatedI was wondering if after drawing an alignment, creating a profile, and profile view, is there a way I can mark items along the alignment so they could show up in the profile view. I am laying out a pipeline and want to have the profile display a marker for items such as tees, elbows, reducers and other items. The marker I would like to use will be something like the vertical style grade break markers.
Also on a side note, as each of these items will have a different name, is there a way that I can add these markers and then have each one with a unique name?
I have some storm sewer alignments that I've put into profiles in C3D 2011. The pipe network that I used to create the alignments from is a reference created from a data shortcut. I've created profiles of these storm sewer alignments, and the station labels for the storm structures are displayed at question marks until I go into the structure properties for each structure and link it to the correct alignment.
The problem is that whenever I synchronize my data shortcuts because someone has updated something, all of the links in each structure to the alignments disappears and I am back to? for my stations in the profiles and I have to go go fix it again. how to keep this from breaking?
I do see this recent message [URL] that appears to be a similar problem, but it was said in that thread that this problem was introduced with C3D 2012, but I am using C3D 2011.....
I imported Google earth surface (at eye alt 600m) to civil 3d 2012 and created an alignment of length 181m.
When I exported same alignment to Google earth , it showed the length as 190m ( the difference increases with increase in length of alignment) And also the profile view of the alignment in the Civil D & Google earth varies.
i have some simple profiles and just want to show the pvi's in plan view on the alignment.
i made a reference label and it works great. now i am trying to figure out if there is a quick way to locate the pvi station on plan view other than doing something like create a point using sta. and offset as parameters hand typing in the info.
I want to change the reference surface for a pipe network with existing pipes and structures. however the changes will only affect new objects, I have to manually change the others one by one. Even with the vista open I can select multiple structures, but when I click in the reference surface column of one of the selected structures, all the others are deselected.
View 6 Replies View RelatedWe are working together with another firm here in town. The are doing the road and we are doing the utilities. They have established the alignments and profiles. When I import them all the data comes in. For whatever reason I do not have their profile views so I create my own profile view and put their profiles in them.
When they send an updated .xml file of all the alignments and profiles, they import okay but my profile views disappear. I assume it's because in their .xml file that I import, there are no profile view defined.
Is there an options when you export and alignment to an .xml file that you can include the profile views with it as well? This way when I import them I would get them.
Is there anyway to display Alignment Station Offset Label at Profile View because sometimes i want to display where is the phisical noze location in profile view also my attached file display what i have in my label and how display my label in profile view.
View 7 Replies View RelatedRun profile on a self-intersecting street? The one I'm dealing with is a dead end 'P' shape. Logically, there are manholes in the intersection of the 'P', and logically to me, these structures need to show up in two places in the same profile view. Of course, C3D doesn't realize that I want a certain structure to show up twice, and I'm not sure how to communicate that information to it.
View 1 Replies View RelatedHaving a rough time with Pipe Networks! I am working an example from the Mastering C3D book (P. 371) as in the following steps:
1.Clicked SS structure(16)
2.Selected Create Alignment from Network on ribbon
3.Selected last structure(18), hit Enter
4.Changed options as needed in Create Align from Network - Create Profile and Profile View check box: Selected
5.Changed options and clicked Create Profile View
At this point the program pauses, then a dialog box trys to partially fill the screen but is all white then fades away as fast as it appeared and I'm stuck with a paperweight that beeps at me everytime I click the mouse, no panning or zooming response at this time. The command line is prompting me for the profile origin. I can switch to other apps and bring up TM and when I attempt to end C3D then it tells me that it can't because waiting for response. I can then cancel the prompt to save the drawing and C3D exits the active command and control is returned.
[URL]
Civil 3D 2013 SP 1, 64 bit
Dell Precision T5600, 16 GB
Win 7 Professional 64 bit
Intel Xeon @ 2.0 GHz
NVIDIA Quadro 4000
Is it possible for a civil 3d structure to be displayed correctly in profile view when the alignment does not pass through the insertion point of the structure. See the attached screen capture.
The rectangular structure is a storage tank and there will be a pipe coming in on one end and the exit pipe will be on the adjacent side at the far end, just as the alignment shows - but the structure doesn't show correctly, or now how I expected.
I have structures and alignments data referenced. If I assign the structures ref alignments in the dwg with the data refs for labeling, the next time I open the dwg the ref alignments are set back to none, causing the labels to be ?
It seems like this worked in the past?
I using a data reference/shortcut to properly label an alignment in paperspace. However when I reference the alignment in and apply the labels the aren't the same as the original alignment that I am referencing. Is there a setting where I am supposed to apply a new beginning station.
Also it seems as though the stationing(distance) isn't even matching up 1:1 with the original drawing. For example in the original base drawing my alignment starts at 10+00 with the next PI at 14+76.98, but the stationing on the reference alignment starts at 0+83.33 with the very same PI being labeled as 1+23.08. So the very same distance is 476.98' in the real design and the drawing it's being referenced in, but the stationing of the referenced alignment shows it as 39.75 Units.
I've attached a screen of the beginning of the alignment.
Civil 3D 2012
Windows 7 Service Pack 1
Intel Core i7-2600 CPU
16GB RAM
So I am trying to edit certain text features dealing with stationing in one profile view (for example I don't want any stationing on the top of the profile view). How do I do this so it will just affect the noted profile view and not delete the stationing on all of my profile views in this drawing.
View 4 Replies View RelatedI have an alignment label that I normally use to show the PVI's of a profile in the plan view.
This is a little unusual, but in a specific case I wanted to design my profile at one alignment, but show it at another. I designed my swale profile in the pathway profile view and then superimposed the swale profile on the swale profile view. I then went back to the swale alignment to add these labels.
It's a no-go AFAICT. The only profile available for me to select for these labels is the original ground profile from the surface.
I'm trying to edit some existing alignments. When I create new entities, they do not show up in the alignment grid view. Why is this?
Windows 7 x 64 bit
NVidia Quadro 2000 Dual Monitor
6.00 GB RAM
Intel Xeon W3550 @ 3.07 GHz
Civil 3D 2013 SP 2, Civil 3D 2012 SP2, Civil 3D 2011 V3, Civil 3D 2010 V3
Launching alignment grid view/alignment entities,
I’m wondering if there is a way to launch alignment grid view/alignment entities (attached) without the need to first launching “alignment”? This dialogue box is quite essential in editing the values of radius, degree of curvature and deflection angle for the selected curve.
I tried moving a Profile View and even though I selected everything at once and selected a base point and destination point, the Profile View Station and Elevation labels moved with a different offset than the Profile View itself. ?
Civil 3D 2012
I created an alignment style specifically to label typical sections. My label style includes a triangular symbol (XSM) and alignment reference text (XSL) attached to the symbol. The label attaches correctly to the alignment geometry points (POB and POE) but the alignment reference text which should call the alignment name instead shows three question marks. At no point in the process am I prompted to select an alignment which is as expected. The label should automatically populate with the alignment name. The label properties indicate the appropriate alignment as the reference object.
Civil 3D 2012 (64)
Windows 7 Pro (64) SP1, 16 GB
AMD Radeon HD 6900
Using Civil 3d2012, Is it possible to change the alignment label style set after the alignment has been created? For example, for an alignment that was created with alignment label set X - change the label set to alignment label set Y? It seems like this should be pretty easy, I must be missing something obvious.
View 2 Replies View Relatedis there any quick way to assign reference aligment to pipe network parts?
I use practise to create one pipe network and afterwards i expand my pipenetwork by editing with lots of aligments (create aligment from network part function i use). Bur there occur a problem in my profile view, when i want to represent station value of aligment and there is now reference aligment in pipe part.
I'm trying to create an alignment label to display profile elevations at regular stations. Two questions:
1. I use an expression to set the text height. When I add a regular text component in the label this works fine, but when I add reference text I can't seem to use the expression as text height.
2. I want to use an expression to 'Truncate' the elevation, so that 178.35m displays as 78.35. I can't find a way to create an expression to do this (within the Alignment station labels).
Maybe my workflow is flawed but I thought I had done this before:
Drawing A has alignments and profile views
Drawing B has DS of alignments from A
User A is working on annotating profile views in drawing A. User B is working on design profiles in Drawing B, adds DS of design profile and everything looks correct in the DS node. But when we try to DS in the design profiles we get the message in the title.
Civil 3D 2012 & 2013
HP Z210 Workstation
Intel Xeon CPU E31240 @ 3.30 Hz
12 GB Ram
Note: Its all Resistentialism, so keep calm and carry on
64 Bit Win7 OS
I know this. I am aware. This is why I avoid changing the reference point as much as possible if I have profile views or anything else dependent on my alignment. I also have no problem with this dialog giving me a useful reminder.
My problem is this: if I want to make my alignment longer, and I grab the grip at the end of it and drag it to a new location, the reference point moves too! Who in their right mind would want the reference point to move when adjusting the end? Personally I wouldn't want C3D to ever move my reference point automatically. I can have some sympathy with moving it if I am grip-editing the start of the alignment, or the tangent on which the reference point resides. But I'm editing at the end of the alignment, on a different tangent. Why would you move my reference point and make me have to go back and reset it to where it was? How dare you throw your warning message at me for moving the reference point back to where it should be when you secretly moved it to a wrong location with no warning whatsoever?
I have a sheet that has several alignments data referenced and labels applied. Recently some of the alignments changed (slightly extended), I checked the sheet and all of the labels have auto updated. Everything looks good. A Print Preview looks good.
When create the print (to pdf), the alignments that changed and all the labels do not show up. Nothing changed with layers, styles, etc. I tried Synchronize and Refresh from Prospector. I can create another Data Ref but don't want to go thru all the labeling again.
Preview and pdf attached.
C3D 2012
C3D 2012 sp1
W7Pro 64bit
HP Z400 Workstation
16 GB RAM
Intel Xeon CPU W3565@3.20GHz
NVIDIA Quadro 4000
I'm working with a structure profile label style and it seems like the only way to anchor the position of the label is based on offsets from the structure itself... Any way to position the label based on the top of the profile view, so that I could make all of my labels horizontally aligned above the profile view?
View 9 Replies View RelatedI try to make curb return profile without profile view like a intersect command.
I was make curb return alignment but I can not find profile command without profile view.
I have a 10 foot profile view and a 15 foot manhole. I want to show the manhole but not the bottom 5 feet. It is extending beyond my profile view.
Civil 3D 2014 SP1
Windows 7 Professional
Intel Core Quad Q9650 3.0 GHz
8 GB, 64-bit
I have yet to produce a profile. I created a polyline and turned it into an alignment.
Looking at alignment Sample(3), I see that it is not superimposed over your surface. The polylines are, but the alignment is not. That will disallow creation of a surface profile.
Is the sample5 an alignment that sits on the surface? how come there is still no profile?
Attached are survey points that created the surface of a road embankment portion that caved-in. The road is very near a reservoir shoreline.
1. How can a surface profile be produce? I/'ve use line to change it into an alignement and then create a proile , then a profile view. But the the surface profile is missing.
2.the points having higher elevation are the top edge( road level) of the cave-n . A few few shots were take before the shorline elevations.
3. What the best way to come up with the rock volume to fill the cave-in given this surveying points., Also the shoreline elevation will be lowered some more while work is being done since the fill is not allowed to fall in the reservoir.