AutoCAD Civil 3D :: Synchronizing Data Shortcuts Breaks Reference To Alignment In Profile Labels

Sep 6, 2013

I have some storm sewer alignments that I've put into profiles in C3D 2011.  The pipe network that I used to create the alignments from is a reference created from a data shortcut.   I've created profiles of these storm sewer alignments, and the station labels for the storm structures are displayed at question marks until I go into the structure properties for each structure and link it to the correct alignment.  

The problem is that whenever I synchronize my data shortcuts because someone has updated something, all of the links in each structure to the alignments disappears and I am back to? for my stations in the profiles and I have to go go fix it again. how to keep this from breaking?

I do see this recent message [URL]  that appears to be a similar problem, but it was said in that thread that this problem was introduced with C3D 2012, but I am using C3D 2011.....

View 4 Replies


ADVERTISEMENT

AutoCAD Civil 3D :: How To Stop Synchronizing Data Reference

Oct 24, 2007

is there a way to stop the synchronization at the start? i would like to synchoronze manually later.

any system variables?

Civil 3D 2012
Work: Xeon W3503, 12GB, Quadro 2000, Dell P2211H x 2
Home: 3930k, 12GB, GTX 590, U3011, QX2710

View 8 Replies View Related

AutoCAD Civil 3D :: Structure Reference Alignment Not Holding In Data Reference

Nov 28, 2012

I have structures and alignments data referenced.  If I assign the structures ref alignments in the dwg with the data refs for labeling, the next time I open the dwg the ref alignments are set back to none, causing the labels to be ?

It seems like this worked in the past?

View 1 Replies View Related

AutoCAD Civil 3D :: Data Reference Alignment Stationing Differs From Original Alignment

May 3, 2012

I using a data reference/shortcut to properly label an alignment in paperspace. However when I reference the alignment in and apply the labels the aren't the same as the original alignment that I am referencing. Is there a setting where I am supposed to apply a new beginning station.

Also it seems as though the stationing(distance) isn't even matching up 1:1 with the original drawing. For example in the original base drawing my alignment starts at 10+00 with the next PI at 14+76.98, but the stationing on the reference alignment starts at 0+83.33 with the very same PI being labeled as 1+23.08. So the very same distance is 476.98' in the real design and the drawing it's being referenced in, but the stationing of the referenced alignment shows it as 39.75 Units.

I've attached a screen of the beginning of the alignment.

Civil 3D 2012
Windows 7 Service Pack 1
Intel Core i7-2600 CPU
16GB RAM

View 5 Replies View Related

AutoCAD Civil 3D :: Multiple Data Shortcuts For Same Alignment?

Jan 25, 2011

For some reason when I try to "Create Reference" to bring in my Alignment, Finished Ground and Existing Ground I get three different alignment data shortcuts instead of them grouping into one. I am trying to find out where in my workflow this all went wrong.

I have a .dwg that just has my alignment files in it. Then I make a new drawing and data shortcut in those alignments and Surface. I make my profiles and then create the data shortcuts for those. I start a New drawing and try to reference the alignment and profile and I get duplicated that aren't grouped. If you take a look at the two .bmp's you can see what happens.

The Purple highlighted area is how I want it to show up and that one worked just fine. Same work flow. The yellow is what is giving me a hard time.

View 9 Replies View Related

AutoCAD Civil 3D :: Profile Alignment Labels

Oct 4, 2012

I would live to label the PVI on my Profiles but not show the PVI label at the start and end of my profile. How to set this?

View 1 Replies View Related

AutoCAD Civil 3D :: Data Shortcuts - Only Reference In Surfaces And Alignments?

Oct 31, 2012

I've just used Data Shortcuts for the first time but I've found that I can only reference in Surfaces and Alignments.  Is this correct? The file I am creating my model in, has Corridors/Feature Lines/Gradings as well but I can't create Data Shortcuts for these? or am I missing something?

View 9 Replies View Related

AutoCAD Civil 3D :: Adding Profile Elevations To Alignment Labels

May 10, 2010

Is there a way in C3D to add elevation information from a profile to an alignment label? What I'm trying to do is add labels to an alignment in a plan view with elevation information from a profile design associated with that alignment at a particular station. For example, the note would read:

ALIGNMENT B
STA: 12+83.67
ELEV: 435.87

I can't figure out how to add any elevation data to the alignment note. I really don't want to have to create a section and a corridor surface, but that's the only way I can think of right now... and I'm not sure that would actually let me add a station and elevation in the same note in a plan view.

View 9 Replies View Related

AutoCAD Civil 3D :: Change Alignment Reference In Profile View?

Sep 18, 2012

I have a profile that references an alignment, I want to change the alignment that the profile view references, can this be done?

View 1 Replies View Related

AutoCAD Civil 3D :: Alignment Data Shortcuts From 2014 In 2013 Are Auto-promoted

Sep 9, 2013

verify if this is the intended forward/backward compatibility between C3D 2014 & 2013.

My project was previously using Data Shortcuts in C3D 2013.  I opened the reference (not the source) drawing that uses a bunch of Alignments.  During the initial drawing upgrade from 2013 into 2014 I get a message for each Alignment that, "{Alignment Name} was modified in a previous version of the software. Changes in the current were overwritten when the data reference was synchronized.".  At this point everything seems fine.

The issue I'm having is that when I re-open that upgraded drawing using 2013 all of those same Alignments become promoted.  They are no longer referenced!

View 5 Replies View Related

AutoCAD Civil 3D :: How To Create Expression In Structure Reference Alignment Profile Elevation

Aug 3, 2013

I am create the stron network. I want structure profile elevation. How to create expression in  structure reference alignment profile elevation.

View 9 Replies View Related

AutoCAD Civil 3D :: Profile Data Shortcuts Not Organizing Properly

Oct 26, 2012

I am using Civil 3D 201...When creating profile data shortcuts, the tree view in tool space incorrectly associates the profiles with several alignments.  This appears to be due to multiple alignments having the same object ID.  This happens when importing alignments from LandXML (a procedure we use to move alignments from one project to another) into a template after inserting exactly the same xrefs into each new alignment drawing.

The workaround appears to be copying the alignment into a different site, deleting the original alignment, then moving the new alignment back to the original site.  Obviously, this changes the object ID so it is more likely to be unique.

View 1 Replies View Related

AutoCAD Civil 3D :: Data Shortcuts With Profile Copied And Raised

Apr 9, 2012

1. Create or use a surface.

2. Create or use an alignment within that surface boundary.

3. Create or use a Surface Profile along that alignment from that surface.

4. Make that surface profile Static instead of Dynamic.

5. Copy that Surface Profile to a Layout Profile.

6. Copy that Layout profile and Raise all VPIs in that profile by 0.25 ft (3 inches).

7. Create data shortcuts for that surface, alignment, profiles.

8. In a new drawing, reference those Data Shortcuts: surface, alignment, all 3 profiles.

Problem:  The Reference to the profile that I raised by 3 inches doesn't reference in Raised.  I had to re-create all the profiles in my new drawing to get the raised profile. 

I can attach my drawing in which my surface, alignments, profiles reside - where data shortcuts were created, my _Shortcuts folder, and the 2nd drawing.

I am trying to share the surface, multiple alignments, all the profiles with my CAD designer and other team members via Data Shortcuts and need for them to reference in correctly.

View 2 Replies View Related

AutoCAD Civil 3D :: Profile Data Shortcuts Missing From Prospector

Feb 21, 2011

I have a drawing that contains an alignment and 2 profiles (existing and proposed).  Call this File A.

I created data shortcuts for these 3 objects and reference them in many drawings.

Last week File A was having some problems, it was inexplicably large and seemed to have some corruption I couldn't fix.  So I created a new drawing, call it File B, and promoted the alignment and profiles into it.

I used Data Shortcut Editor to point the data shortcuts to File B.  In drawings that already referenced these objects they look like the they are coming through just fine. 

The problem is that I can't see the profiles listed in the Data Shortcuts section of prospector.  The shortcuts folder selected is correct, the xml file is there, it points to File B.  The alignment is listed and I can create that reference in a new drawing.  I also can't find anything wrong with File B.

View 9 Replies View Related

AutoCAD Civil 3D :: Print Doesn't Match Preview Alignment Data Reference

Jul 12, 2013

I have a sheet that has several alignments data referenced and labels applied. Recently some of the alignments changed (slightly extended), I checked the sheet and all of the labels have auto updated. Everything looks good. A Print Preview looks good.

When create the print (to pdf), the alignments that changed and all the labels do not show up. Nothing changed with layers, styles, etc. I tried Synchronize and Refresh from Prospector. I can create another Data Ref but don't want to go thru all the labeling again.

Preview and pdf attached.

C3D 2012
C3D 2012 sp1
W7Pro 64bit
HP Z400 Workstation
16 GB RAM
Intel Xeon CPU W3565@3.20GHz
NVIDIA Quadro 4000

View 2 Replies View Related

AutoCAD Civil 3D :: Profile Label Reference To Pipe Data

Oct 29, 2013

A method (possible expressions) to create a profile view label that can reference pipe or structure data?

View 5 Replies View Related

AutoCAD Civil 3D :: What Is Causing EG Data Reference Surface To Disappear On Screen And Profile

Oct 10, 2013

What is causing my EG Data Reference Surface to disappear on screen and Profile goes to crap?  I've noticed this twice on same project in separate drawings.  If I go to Toolspace and synchronize then it appears back on screen. 

First dwg:  I created a Pump Station Site Plan and data referenced in my surface and pipe network.  I save and close then reopen and EG is gone until I synchronize.

Second dwg:  I created a Railroad Crossing Exhibit showing plan and profile.  I data referenced in my surface and pipe network.  Same thing...save, close, reopen and I have to synchronize it to have plan and profile to appear ok.

This isn't good when I have .dsd files that I typically plot my drawing package from.  I sent multiple sets of drawings to the plotter and all my Pump Station Site Plans were missing the surface contours.  For this sheet, I had to synchronize and send separate plots just to have contours appear.

View 5 Replies View Related

AutoCAD Civil 3D :: Existing Elevation Labels At Datum And Top Grade Breaks?

Aug 28, 2012

i created section view as in pic1. In Bands, Existing surface elevation labels at existing surface grade breaks, top of road elevation labels at top grade breaks, datum is the same. Can i add existing surface elevation labels at top of road grade breaks? (pic2)

View 7 Replies View Related

AutoCAD Civil 3D :: Why Does Not Consider Curve Labels As A Part Of Alignment Labels

May 3, 2013

I think it is normal to want a style showing stationing, speed design stattions, etc.But.... Radii of curves ? Clothoid parameters ? 

Why is the reason Autodesk developers think that designers dont want to see this information instead of "add labels, aligments, multiple segments,. etc .... 

(aligment by aligment ...... of a whole project ?

Civil 3D (2013)

View 9 Replies View Related

AutoCAD Civil 3D :: Alignment Style Vs Alignment Labels - PI Treated Differently?

Apr 6, 2013

I have a question on Alignment PI's. (Point of Inflection/Intersection)I have an alignment where some PI's have curves, others are merely hard bends.

Is there a way to automatically label the PI's even if they have an associated curve? (I'd like PI, PC and PT)Alternatively, can I only show markers at PI's without curves?

View 9 Replies View Related

AutoCAD Civil 3D :: Data Shortcuts Transferring Super Elevation Data

Jun 7, 2012

I'm having problems getting super elevation data to transfer to different drawings by means of an alignment data shortcut.  I know alignments hold the super elevation data so I've gone into my alignments data shortcut, input my super elevation data, saved and closed.  Now when I open my finished grade drawing, reference in my alignment and profiles, then create a corridor from that information, my super elevation didn't transfer with the reference.

I pulled cross sections and it appears is has no clue there is any super elevation data.  Also, I tried bringing it directly into the drawing I'm doing my corridors in and it erred saying I must be in the parent alignment drawing.  Data shortcuts are pretty much useless to me if super elevation data doesn't transfer. 

64 bit Windows 7
Intel Xeon (R) @2.8GHz
6.00GB Ram
Civil 3D 2012
Civil 3D 2012
Intel(R) Xeon W3530 @ 2.80GHz
6.00GB Ram
Windows 7 Professional

View 2 Replies View Related

AutoCAD Civil 3D :: Profile Geometry Points Of Superimposed Profile To Alignment Label

Mar 1, 2013

I have an alignment label that I normally use to show the PVI's of a profile in the plan view.

This is a little unusual, but in a specific case I wanted to design my profile at one alignment, but show it at another.  I designed my swale profile in the pathway profile view and then superimposed the swale profile on the swale profile view.  I then went back to the swale alignment to add these labels.

It's a no-go AFAICT.  The only profile available for me to select for these labels is the original ground profile from the surface.

View 5 Replies View Related

AutoCAD Civil 3D :: Reinserting Alignment Labels?

Apr 29, 2009

I accidentally deleted the major and minor station labels along my alignment. Is there a way to re-insert them?

View 5 Replies View Related

AutoCAD Civil 3D :: Where To Set Styles For Alignment Labels

May 2, 2013

I want to add labels for my aligments. (segments or multiple segments)

I dont see any dialog, c3d directly is asking me to click on aligments 

(So I cant choose what styles I want).,

Maybe I have a variable with wrong value ? (Dont show dialog ????) 

Civil 3D (2013)

View 9 Replies View Related

AutoCAD Civil 3D :: Alignment Chainage Labels 420.000 Not 4+20.00

Sep 7, 2013

How do i make my chainages show as 420.000 rather than 4+20.00.I.e I need to take the plus sign out (we never use them - only whole distances) and I need it in 3 decimal places.

View 3 Replies View Related

AutoCAD Civil 3D :: Alignment Labels - Wipeout?

Mar 29, 2012

Is there anyway to place a wipeout behind the station value for an alignment label?

I want it to look like:

---------------------------- 3+00 -------------------------

So i just moved the station with the Y offset variable but now need to get rid of the alignment where the label is.

View 5 Replies View Related

AutoCAD Civil 3D :: Offset Alignment Labels

Apr 29, 2013

Can I offset my alignment labels?

I want to show the alignment staining #'s but I also have a corridor and sample lines running through the stationing that I want to see.  I do not wish to drag every alignment label and then have the leader showing.

View 1 Replies View Related

AutoCAD Civil 3D :: Alignment Labels In Format

Apr 3, 2012

I want the stationing information in display, labels etc to be in the format: x+xxx.xxx. What I get by default is XX+XX.XXX. How can I my desired label format style and lock it?

View 1 Replies View Related

AutoCAD Civil 3D :: Resetting Alignment Tag Labels

Aug 20, 2006

Is there a way to reset the alignment tag (line & curve) labels to begin at 1 when previous labels were created for the alignment and then deleted?

View 6 Replies View Related

AutoCAD Civil 3D :: Upside Down Alignment Labels?

May 15, 2013

I have created an alignment in Civil 3D 2013, from 100+00 to 6740+00 and Station 5040+00 thru 5400+00 are upside down both in the respected drawing and the alignment itself. I have checked and double checked all the settings and they all seem to be correct. This has really got me dumb founded.

View 9 Replies View Related

AutoCAD Civil 3D :: Any Way To Delete Labels Of Particular Alignment

May 2, 2013

Or maybe I have to delete it individually ? Is not an option to "delete alignment labels".

View 9 Replies View Related