AutoCAD Civil 3D :: Pipeworks Pipe Styles - Display Setting Not Working In Profile View
May 7, 2012
Header says it all. For example, if I set a pipestyle to display the inside walls with linetype Continuous, it works ok in plan view, but not profile.
When I select the pipe top edit its style (right click context menu), it is in the Profile View, but the changes are happening in the plan view.
Where I should set it to display how I want in the profile view?
C3D 2012 on 64bit Win 7 all up to date
Dell Precision 7core 8GB RAM
NVIDIA Quadro FX 1800M
LDT/C3D user since release 12
View 2 Replies
ADVERTISEMENT
Jul 13, 2012
I am using C3D 2012 sp2.
I have a autocad file with MEP pipe objects (piping layout inside a building). If I start a new drawing using our company (dwt) template then xref in the cad file with the MEP objects they do not display. If I start a new drawing using one of autocads default (dwt) templates then xref in the MEP objects they display fine. My question is somewhere in our company template is a setting for MEP objects to be displayed .
View 2 Replies
View Related
Jan 8, 2014
I can create labels to display stationing in a profile, but is there a way to display the coordinates in the profile instead? When I need to move my pipes I am using the station I get from the profile label and then use grip move. If I could get the N, E, I could just type it in on the Vista table.
AutoCAD Civil 3D 2012 SP4
Windows 7 (64)
View 4 Replies
View Related
Dec 2, 2010
I am having problems with the display of my structures in a profile view. Previously, when I change the inverts of the pipes connected to my structure it would automatically adjust the bottom (sump) of the box invert to match my lowest pipe. However, for some reason it has stopped doing it and is now displaying the sump invert incorrectly. I have my style set to "Display as a Boundary". I have edited the structure sump to be by both elevation and depth, but it does not update the sump elevation. I have tried to grip edit the sump but it seems to be locked at a certain elevation. I have a profile with 10+ structures and they are all at multiple depths. I realize there are minimum depths allowed by the structure, but I have exceeded the minimum depths in all cases. Attached is an image that depicts my problem. No matter what I do to change the depth it stays locked at a certain elevation.
Civil 3D 2011, SP1
View 9 Replies
View Related
Dec 20, 2012
I was wondering if after drawing an alignment, creating a profile, and profile view, is there a way I can mark items along the alignment so they could show up in the profile view. I am laying out a pipeline and want to have the profile display a marker for items such as tees, elbows, reducers and other items. The marker I would like to use will be something like the vertical style grade break markers.
Also on a side note, as each of these items will have a different name, is there a way that I can add these markers and then have each one with a unique name?
View 9 Replies
View Related
Apr 25, 2012
I click on my pipe in profile. Right click and add label. I see nothing, no label. All layers on and un-frozen.
View 6 Replies
View Related
Feb 4, 2013
As it stands, if you view a pipe network in a profile view with no vertical exaggeration, you expect to see what is essentially an accurate long section in all directions. However, rather than being applied perpendicularly from the center line (or arguably the invert), diameter is applied strictly vertically.
Now, this made sense in the days of hand drafting when it was far easier in a vertically exaggerated profile view to simply measure the dimension vertically rather than determining how the exaggeration affects the perpendicular distance. But with the computer doing the measurements, is this really a problem anymore? I've debated that to some degree it's strange to consider that the crown of the pipe may be at a (slightly) different station than the invert, but this is simply fact in the field. And I've also thought that it's nice to be able simply measure vertically in an exaggerated profile, but I can't remember the last time I dug my scale out of the drawer.
All the theory aside, the real problem appears when you try to profile a vertical, or even a near-vertical, pipe. The fact that the diameter is applied vertically means that the vertical centerline is shifted the length of the pipe radius downward and upward. In other words, rather than seeing the invert and crown of the pipe, you just see one line, though it's really two lines on top of each other.
I wrote this off for the last 4 years of basic Pipe Networks because I acknowledge that storm/sanitary outside the building is rarely designed vertically, but with 2013's release of the Pressure Pipe Network, I really expected Autodesk to change the way the profile views represented pipes.
View 3 Replies
View Related
May 19, 2013
Need getting pipe top elevation in profile view data band? In labels it's possible to perform calculations via expressions. In data bands – not. Inablity to get pipe outside top elevation in profile view leads to dead end in my hunt for smooth workflow.
View 5 Replies
View Related
Dec 9, 2013
I have my alignment running up the page, it is the red line. I can show the profile of the pipes and structures that run with the alignment but I want to she the elevations of the crossing pipes, not just the circle in the structures where they cross but the elevation of the crossing structures and pipes, (str 102-103 and 104-105). Almost like a profile that is cut and looks north (up) instead of the cut looking east west.Can I turn my profile view or take a view at a certain station or do I need to make alignments that run east west to do this? I have included a pedicure for reference.
View 3 Replies
View Related
Feb 7, 2013
I created a pressure pipe with no bends since my alignment is fairly straight. However, I'm changing the elevations on the pipe using a combincation of the profile view snaps and elevation edits in the properties and it doesn't restrict my deflection to my deflection settings not does it add any bends.
Is this still a missing function in Pressure Networks? Or is there something I'm missing?
View 1 Replies
View Related
Jun 6, 2012
I cannot find a way to only have pipes in profile view to only show the invert (bottom) of the pipe. All my pipes are running around the same elevation and the profile is pretty busy with both invert and crown of pipe shown.
View 2 Replies
View Related
Sep 6, 2013
Every structure for my Sanitary pipe network is showing up properly in the profile view except the last 2. They're showing as rectangles when they should have the cone on top. I've checked the properties of the correct ones and the incorrect ones and they're the same style. I looked at the parts and I couldn't see anything wrong with them. In the screenshot you can see that the 3 manholes on the left are the correct kind with the cone whereas the 2 on the right are just rectangles.
View 8 Replies
View Related
Feb 22, 2012
I've been having a problem with a pipe structure not showing up in a profile view. I have a single pipe network with everything (pipes and other structures) showing up in the profile when I select them, right-click, and click on "Draw Parts in Profile". Like I said, this works for all the other pipes and structures in the profile except one. When I select the structure individually and try to draw it into the profile, it still won't work. A friend told me to make sure that the structure is within the surface, and it is.
I'm using AutoCAD Civil 3D 2011.
View 6 Replies
View Related
Aug 15, 2013
I have a Storm pipe network for a subdivision. All of the pipe are on the same layer, using the pipe style. For some reason, only 1 of 68 pipes will display through my viewports. All of the layers within the pipe style are thawed in my viewports, as well as the layer the pipes themselves are on.
Further, when I go back to an archived file from a few days ago, all the pipes are also on the same layers and styles, and all pipes display as they should through all viewports. There seems to be no rhyme or reason for this. I am not sure what could have changed as I didn't knowing adjust anything with the pipe networks since archiving a few days ago
View 5 Replies
View Related
Dec 9, 2013
I clicked on a pressure pipe in profile view and selected "Edit Pressure Network in Profile...". The panel that came up has a button that says "Follow Surface". I did that and selected all of my pipe and entered 4 feet below surface for my water main and it put alot of deflections in my pressure pipes. How to remove the deflections?
View 2 Replies
View Related
Jul 30, 2011
If I have a Crescent Road (P - shape) where the Alignment returns to itself, when i draw pipe network parts in profile, the pipe network gets drawn wrong, ie. the tie-in structure at the intersection is drawn at the wrong station.
My understanding is that the structures will get drawn at the station closest perpendicularly to the alignment, so the structure is going to the end station as opposed to the beginning simply because the end segment of the alignment is closer.
Is there any way to make a structure use a different perpendicular station (without shortening the alignment)?I don't want to move alignment or structure.
View 8 Replies
View Related
Jan 18, 2013
I was given a horizontal centerline of a 5 mile bike path. We have to stake all the even stationing every 50 feet and all the VPC's and VPT's with vertical elevation. I have created the horizontal profile and also the vertical profile including all the vertical curve information. Is there an easy way to incorporate the elevation information back into the plan view so I can create points that carry x,y & z points that I can transfer out of autocad as a .txt file so we can upload it on our gps equipment?
View 9 Replies
View Related
Mar 2, 2012
We have a big piping job coming up and as Civil3d still lacks some of the labelling abilities we want in the profile view bands. I am updating some old vba that adds a profile line of the invert of a pipe network to a profile view effectively tracing along the bottom of the network like I know a lot of people do by hand.
My original code works on assuming that the start and end structure are at the start and end of the alignment in the revised code I want to allow for situations where this is not the case.
Leading to my question is there and easy way to find the distance a profile view part is drawn along the parent alignment or do I have look at writing my own function possibly extracting a polyline from the alignment and finding the distance using intersectionwith and distancefrom functions with the structure.
View 2 Replies
View Related
Dec 31, 2013
Using part builder, I created a new pipe part for an odd-sized CMP arch pipe. In plan view, the pipe looks good. At first glance, I thought the pipe was drawn correctly in a profile view, but I realized that the pipe was displayed with the invert located at the wrong place in the profile view. I thought this was because the insertion point of the new pipe part that I had made was placed at the incorrect location in part builder.
So, I swapped out the incorrect pipe size for another one that I knew was correct, and then deleted the incorrect pipe from the pipe parts list, and went back to part builder, and placed the insertion point at the invert of the pipe; then saved the edited pipe part, ran partcatalogregen, added the "corrected" pipe part to the pipe parts list and swapped in the new corrected pipe size to the pipe network. However, the pipe still displays incorrrectly on the profile view.
The pipe data is correct in the pipe properties: the invert is stated to be located at elevation 20. The overall height of the pipe , 38" (3.1667') is correctly displayed on the profile view. But the actual location of the pipe invert is not shown at the correct location, elevation 20, on the profile view.
View 4 Replies
View Related
Mar 21, 2013
I'm trying to add assign a Pipe Network to a profile view Band in Civil 3D 2011. I was using COM to add profiles to bands because I couldn't figure out how to do it in .NET. But when it comes to pipe networks I don't see how you can do that with COM. How the .NET implementation is supposed to work? Here's the code I have that works for COM, except for the pipe networks. I essentially need to assign the correct pipe network to the band.
public static void AddProfileToBand(this ProfileView profileView, ObjectId profObjId, List<BandItemInfo> bandStyleInfosFromSet, ObjectId profileBandSetId){
using (Transaction tr = Application.DocumentManager.MdiActiveDocument.TransactionManager.StartTransaction())
[code]....
View 1 Replies
View Related
Apr 30, 2013
How I have come to this question is through the process of trying to realistically show a hydrant in profile view. First off it it possible to create a completely vertical pipe in C3D? Also if you can, is it possible to show that in profile view? Basically, what I am trying to avoid is representing a fire hydrant pipe by creating some sort of custom cyclinder part in partbuilder. I have done this, but do not like the results.
Civil 3D 2013 SP2 | Win 7 64-bit SP1
Intel Core i5-2500 @ 3.30GHz, 8GB Ram | ATI Radeon HD 5450
View 3 Replies
View Related
Oct 15, 2013
The list of bands with location selected as 'bottom of profile view' is blank, where as 'top of profile view' displays the info correctly. With this error I can't select any of the band to add remove modify them.
I have attached 2 pdf's showing top and bottom views.
View 1 Replies
View Related
Nov 20, 2013
Pipe network storm pipes: Fairly new to Civil3D and trying to set up parts list for the storm sewer pipe and would like the plan view to appear as it does currently. We use a polyline for centerline of pipe, similar to dashed linetype but line and space are the same, width set to pipe width.
View 1 Replies
View Related
Jul 20, 2012
I tried moving a Profile View and even though I selected everything at once and selected a base point and destination point, the Profile View Station and Elevation labels moved with a different offset than the Profile View itself. ?
Civil 3D 2012
View 2 Replies
View Related
Jul 20, 2012
So I noticed that my data reffed pipes were reverting back to their default styles in my production drawings. This wasn't a problem with SP1. I made a support call to our reseller and they mentioned that the only work around was to completely uninstall Civil3d, then reinstall back to SP1. He mentioned that he was passing the information on to Autodesk and he would let me know if they had a fix. Naturally that kind of timing or solution doesn't really work for me. This problem will effect any drawing I have that has pipes in it.
I want to know what you have done to work around this? Is there a better solution than uninstalling Civil3d?
View 4 Replies
View Related
Jun 18, 2008
I'm trying to find out what could be the cause of sturcture styles in a Pipe Network Design Drawing resetting to default styles when I Data Shortcut the design into my Sheet? (I.e. I've got gate valves, fh's, and plugs in my design file, but when I data shortcut them into my sheet they are all come in as null structures) Not Cool!
I'm using the same template that contains all the same parts/styles for both design and sheet.
View 9 Replies
View Related
Jan 10, 2013
I have created a complicated 3D utilities model using pipe networks. All the clashes have been ironed out, the 3D DWF looks great when rotated, the client is happy. Now It is time to hand it over to the contractor to build. He hasn't got Civil 3D and isn't going to get get it. He either want's the information as an x,y,z, text format or a 3d polyline. I cannot see anyway of doing this with the tools available.
View 9 Replies
View Related
May 9, 2012
I can't find the setting for setting the default pipe network layers - dialog that opens when I create a network.
I have different utilities, obviously want them on the right layers.
E_WM --> exst. WM layers plan/profile
E_SAN--> exst. sanitary layers plan/profile.
etc.
I have a template drawing I am getting my styles from. where in the template are these things set?
View 4 Replies
View Related
May 7, 2012
How to set stakeout points on a pipe network? I have an alignment from the engineer that also has a pipe network associated with it that I would like to automatically set points vertically and horizontally on (like I can do with a regular alignment/profile).
C3D - 2014
View 2 Replies
View Related
Nov 4, 2013
I'm working with a structure profile label style and it seems like the only way to anchor the position of the label is based on offsets from the structure itself... Any way to position the label based on the top of the profile view, so that I could make all of my labels horizontally aligned above the profile view?
View 9 Replies
View Related
Feb 28, 2011
I try to make curb return profile without profile view like a intersect command.
I was make curb return alignment but I can not find profile command without profile view.
View 6 Replies
View Related