AutoCAD Civil 3D :: Structure Label When There Is Mix Of Circular And Box Pipes

Mar 4, 2013

In the case of a pipe network structure, where one pipe is circular (say 60") and the other pipe is box (say 5'x4'), how can you get the "connected pipes" label to reflect [size in feet X size in feet] for the box pipe and [size in inches] for the circular pipe?

I don't see how you can conditionally affect a portion of the "connected pipes" label since it's one label object.

View 9 Replies


ADVERTISEMENT

AutoCAD Civil 3D :: Display Order Of Connected Pipes In Structure Label

Dec 29, 2011

A way to change the display order of pipes connected to the structure in a structure label? (plan and profile) Say you have a 10", 6" and 12" pipe connected to a structure, modeled in that order, so label would place them 10, 6, 12.  we would like the label to display the order as 6,10, then 12 without having to drag the pipes off and then having to re-input inverts.

View 6 Replies View Related

AutoCAD Civil 3D :: Structure Label Expression - Circular Versus Rectangular

Dec 13, 2013

I'm trying to create a custom expression in a structure table that will list the "size" of the structure, wheter it be a circular or rectangular structure.  My column simply states size and I want it to label 5' for a circular or 4'x4' for a rectangular (or whatever the specific sizes are).  The thought was to create an IF function, but Structure Shape was not available to use in expressions (among other problems).  Short of using the description field (tedious) as a workaround?

In this example - CB-104 is a rectangular structure and CB-106 is a circular.  I'd like the CB-104 size to read 4'x4'.

Civil 3D 2014 SP1

View 5 Replies View Related

AutoCAD Civil 3D :: Extending Pipes To Structure Symbol?

Mar 6, 2012

We've had a little nagging problem that we've just been living with, but getting a little tired of it: when building a pipe network the plotted line will stop plotting at the outter wall of the structure, thus leaviung a gap between the pipe and the structure.  On a 48" manhole it's hardly noticable, but when the manhole gets larger, so does the problem.  Check out the attached pdf and you'll see what I'm talking about.

I've been through all the style setting I can think of, but I thought there might be a variable to take care of it...like the FACETDEV variable for crossing pipe.

View 1 Replies View Related

AutoCAD Civil 3D :: How To Model Two Pipes Coming Out Of A Structure

Oct 17, 2013

I am trying to model a system of existing storm pipes, where the last catch basin actually has two outfalls: one an 18" pipe and the other a 24" pipe.  They have different invert elevations. 

I have the pipes set up correctly in Autocad, so that the profile shows up right, and the plan view in Storm Sewers shows up right, too.  However, the model does not separate the flows. 

Is there a way to manually enter the approximate amount of flow that will discharge through each pipe?

View 1 Replies View Related

AutoCAD Civil 3D :: Can't Label Certain Pipes / Structures

Mar 7, 2012

why I can't label certain pipes/structures?  I can select the pipe or structure, rt click, add label and I get nothing.  The layer is on cause I can see other labels. I also get the same result when I go to annotation, pipe label.   This only happenes to certain pipes or structure, others in the same network label fine.

View 9 Replies View Related

AutoCAD Civil 3D :: Label Pipes / Polylines

Aug 23, 2013

I received some dwg files to show existing utilities from a local municipality. I thought the files would come as shp files, but they are dwg files. The drawings/dwg files show the layout of pipes, but the pipes are polylines. The polylines have data attached to them. The properties show material, size, length, slope, etc. I am trying to label the pipes/polylines and I can't figure out how to get the information from the polylines.

View 4 Replies View Related

AutoCAD Civil 3D :: How To Label Spanning Pressure Pipes

Dec 13, 2013

How do I label spanning pressure pipes?  I can do it in a pipe network, but not a pressure pipe network.

View 1 Replies View Related

AutoCAD Civil 3D :: Pipes - Label Entire Network Profile / Want Crossings Only

Dec 5, 2012

I have pipe crossings shown in my profile.  Only crossings (NO PROJECTIONS).  So many elipises.  I want to label them.  Setting the label style at the pipe network does not work (will not override whatever label style was assigned at the pipe creation).  I have accepted this (although it sucks).

Now, to get around it, I go Pipe>Add Label>Add Pipe Network Label.  Label type is "Entire Network Profile".  When I do this, it labels not only the crossings but all projections.  So I have a million labels chilling out in space, where I have no crossing.

View 1 Replies View Related

AutoCAD Civil 3D :: Structure Label Layering

Feb 19, 2013

I have my pipe networks data referenced into my Utility drawing and I'm trying to add labels to my structures (catch basins, manholes...). I made styles and selected C-TEXT as the layer for the label, but for some reason they're all on layer 0.  The 0 layer is frozen in my viewport but the C-TEXT layer is not, and the labels aren't showing up (but when I thaw 0 they show up)!  I can see them in model space and when I click on each label the properties shows it's on the C-TEXT layer...

View 2 Replies View Related

AutoCAD Civil 3D :: Specific Structure Label

May 16, 2013

I need to make a structure label that defines the "PIPE FALL" for each incoming pipe. By "PIPE FALL", I mean the elevation difference between the bottom of the structure and the incoming pipe invert elevation. 

Actually, I thought it was going to be pretty simple, just by doing: 

PIPE FALL = INCOMING PIPE INVERT ELEVATION - OUTGOING PIPE INVERT ELEVATION <CONNECTED PIPE OPPOSITE STRUCTURE NAME> 

or 

PIPE FALL = INCOMING PIPE INVERT ELEVATION - SUMP ELEVATION <CONNECTED PIPE OPPOSITE STRUCTURE NAME> 

I just need to define the elevation difference between the bottom of the structure and the incoming pipe invert elevation.

View 9 Replies View Related

AutoCAD Civil 3D :: Get Structure Label To Stop Flipping?

Oct 14, 2013

Is there a way that I can get a small angle between my leader and the landing? When I get to a certain angle, the text flips. I can't place the text exactly where I want it because of this. I've tried changing the Readability Bias angle in the label style but that didn't work.

View 2 Replies View Related

AutoCAD Civil 3D :: Profile Structure Label Wipeout?

Apr 11, 2013

I would like to add a wipeout to this structure label so I don't see the profile view grid lines. I want the wipeout to be the exact width and height of the label. I have tried numerous edits but can't seem to get it. What is the easiest/best way to add this wipeout?

View 9 Replies View Related

AutoCAD Civil 3D :: Pipe Network Structure Label Layers

Jan 8, 2013

I have a pipe network created that is shown in multiple drawings.  I created labels for the structures showing Rims and Inverts. How to put the Rim info on a different layer than the Invert info?  Right now the label has 3 different components...I feel like there has to be a way to put each component on different layers...

View 6 Replies View Related

AutoCAD Civil 3D :: Specific Structure Label - Pipe Network

May 21, 2013

I need to make a structure label that defines the "PIPE FALL" for each incoming pipe. By "PIPE FALL", I mean the elevation difference between the bottom of the structure and the incoming pipe invert elevation. 

Actually, I thought it was going to be pretty simple, just by doing: 

PIPE FALL = INCOMING PIPE INVERT ELEVATION - OUTGOING PIPE INVERT ELEVATION <CONNECTED PIPE OPPOSITE STRUCTURE NAME> 

or 

PIPE FALL = INCOMING PIPE INVERT ELEVATION - SUMP ELEVATION <CONNECTED PIPE OPPOSITE STRUCTURE NAME> 

I just need to define the elevation difference between the bottom of the structure and the incoming pipe invert elevation.

View 9 Replies View Related

AutoCAD Civil 3D :: How To Handle Station Offset With Storm Structure Label

May 18, 2012

Typically when we have station offset for a storm structure shown to center of structure. How do you handle station offset with a storm structure label for say back of curb.

View 3 Replies View Related

AutoCAD Civil 3D :: Structure Label - Pipe Inlet And Outlet Elevation

Dec 10, 2013

I would like to know if it is possible to display the pipe inlet/outlet elevation in my structure label. It seems like it is not possible.It is possible to use the inlet/outlet elevation of the pipe in my pipe label however I would like to display it in my structure.

View 2 Replies View Related

AutoCAD Civil 3D :: 2014 - Pipe Network Structure Profile Label

Jul 30, 2013

Water main pipe network profile labels for structures do not attach to the structure properly in C3D 2014 (this same label style works fine in all previous versions of the software, through the 2013 release). The labels come into the drawing at a northing of 0 rather than attaching to the structure itself. However, if you grip edit and reset the labels, they reset to their correct attachment point. Additionally, if you attempt to grip edit the profile labels with Ortho mode on, it moves the label back to a northing of 0. I've created a new block for the structure, but that does not resolve the issue.

I've included a link to a Chronicle video that demonstrates the label behavior. [URL] .......

View 3 Replies View Related

AutoCAD Civil 3D :: Structure Label Component Does Not Show While Dragging Into Place

Aug 2, 2013

When I reposition structure labels (in their 'dragged state'), the component <[Structure Offset Side(CU)]> does not show up while in drag mode. Sort of makes it hard to see the limits of the label if you are trying to place it in a congested area. Watch the "LT" part of the label in the GIF below.

No, it's not that big of a deal, but alignment labels with the same component do not behave this way, so I have to wonder why the structure labels do.....

View 4 Replies View Related

AutoCAD Civil 3D :: Structure Label Reference Road Centerline Stationing?

Mar 13, 2013

I have a road with storm drain and sanitary sewer. There are three alignments, one for the road centerline, one for the sanitary sewer and one for the storm drain. I would like to label the structures with the stationing from the alignment it's on but I would also like the label to include the road centerline station perpendicular to the structure.

Something like this:

SS-MH #4

Sta. 10+00

=Road Sta. xx+xx

View 2 Replies View Related

AutoCAD Civil 3D :: Structure Plan View Label Goes To Edge Of Manhole Instead Of Center

Feb 10, 2013

I have a label style creating a callout bubble for structures in a pipe network, but it keeps placing the label (and therefore, the leader when dragged) at the edge of the structure, and I want it to go to the center.

View 2 Replies View Related

AutoCAD Civil 3D :: How To Base Structure Profile Label Location On Top Of Profile View

Nov 4, 2013

I'm working with a structure profile label style and it seems like the only way to anchor the position of the label is based on offsets from the structure itself... Any way to position the label based on the top of the profile view, so that I could make all of my labels horizontally aligned above the profile view?

View 9 Replies View Related

AutoCAD Inventor :: Create Rectangular / Circular Pattern For DNA Structure

Oct 18, 2011

Is there a way to create an upwards circular pattern, or a rectangular pattern with a circular movement?I'm trying to create a DNA-structure

View 1 Replies View Related

AutoCAD Civil 3D :: 2012 - Pipe Structure Editing - Changing Preset Lists For Structure Sizing

Nov 4, 2011

We use C3D 2012 (metric only) - We are attempting to customize our list of structures for Sanitary Sewers.  The structure list shows sizes we do not use and we would like to modify them.  However, when we try to select the "Inner Diameter" it displays a list of sizes that we can not seem to modify or add to.

I have looked at some of the XML files to try and modify or add new sizes (example: AeccStructConcentricCylinder_Metric.xml) , but they do not seem to be recognized even after I restart the program.

Here is what the file looks like:

<ColumnConstList desc="Inner Structure Diameter" dataType="float" unit="mm" name="SID" id="CCL1" visible="1" context="StructInnerDiameter" index="0">

<Item id="i0">1200.0000</Item>
<Item id="i1">1350.0000</Item>
<Item id="i2">1500.0000</Item>
<Item id="i3">1800.0000</Item>
<Item id="i4">2050.0000</Item>
<Item id="i5">2300.0000</Item>
<Item id="i6">2550.0000</Item>

I tried modifying the last line replacing 2550 with 3600.

I also tried adding a line  <Item id="i7">3600.0000</Item>

I saved the XML file and restarted the program with nothing changing that I can see.

Looking for correct file(s) to edit so I can modify the LISTS that come up in the piping modules.

View 2 Replies View Related

AutoCAD Civil 3D :: How To Get Pipe Structure To Be Sphere Like Null Structure

Feb 12, 2008

One good thing about null structures is the way they display in 3D. They cover that gap in the pipe segments. Can I steal that shape?
I am currently using a simple cylinder for water pipe "joints" and turning it off like most people do I think.

View 4 Replies View Related

AutoCAD Civil 3D :: Concentric Structure To Eccentric Structure

Apr 30, 2012

I have drawn a pipe network with multiple concentric sturctures. I need to make them all eccentric now. Is there an easy quick way to do this, or do I have to redraw all of them. When I go to the properties, I cannot find an option that allows me to change this.

View 2 Replies View Related

AutoCAD Civil 3D :: Point Label Size Change When Label Is Moved?

May 8, 2012

The label associated to a grading point when is moved when is moved changes its size automatically and a leader appears. After this happen no control over the grading point and its associate label. refer to the image below.

View 1 Replies View Related

AutoCAD Civil 3D :: Changing Profile Line Label Style Causes Label String To Revert To Default

Sep 6, 2012

C3D 2013. We have profile line labels, some of which get manually edited (for example, change the "<[Tangent grade(FP|P2|RN|AP|GC|UN|SD|OF)]>" to a static number such as 0.29%).

However, if you CTRL+Click and select one of these labels and change the style of that one label, then the manual edits are lost and the label reverts back to the default string.

Is there any way to turn this behavior off?

View 1 Replies View Related

AutoCAD Civil 3D :: Edit Label Text In Parcel Label

Jan 3, 2013

Is there a way to "Edit Label Text" in a Parcel area label? Similar to the way you can edit it in other styles.

View 9 Replies View Related

AutoCAD Civil 3D :: Label Profile Label Stations As Raw

Aug 8, 2013

I'm trying to label my Profile label stations as raw stations, 20~20 meters, and I'm not being able to adapt the format to STATION 0, STATION 2, without any plus zeros or +, or -, or commas, or anything, as following in the image.

Is there a easy way to do it?

View 2 Replies View Related

AutoCAD Civil 3D :: How To Add Pressure Pipes

Apr 17, 2013

I've been able to publish and then import valves, flange adaptors etc. with no problem, but if I create a flanged (metric) pipe using the Content Catalog Editor and then draw the pipe in C3D it shows blank ends, no flanges. I've split the pipe in the drawing to see if that forces flanges to appear, but nothing.

Do I need to create the flanges seperately and then add them to the end of pipes?

I'm using Civil 3D 2013

View 1 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved