AutoCAD Civil 3D :: Can't Label Certain Pipes / Structures
Mar 7, 2012
why I can't label certain pipes/structures? I can select the pipe or structure, rt click, add label and I get nothing. The layer is on cause I can see other labels. I also get the same result when I go to annotation, pipe label. This only happenes to certain pipes or structure, others in the same network label fine.
View 9 Replies
ADVERTISEMENT
Aug 22, 2012
In a run of pipes and structures, I have 3 structures that overflow. 2 of the structures max hgl els are even with the rim elevation (as is in the case of other runs in the same project), and 1 structure has the max hgl exceeding the elev of the rim. Why this one and not the others?
View 2 Replies
View Related
Oct 11, 2013
I'm trying draw profile, I see "compile error can't find project or library",
then I select "convert VBA pipe and structure rules to .NET" it works until I turn off civil 3d
how to do, that it works for everytimes?
View 3 Replies
View Related
May 24, 2012
I am attempting to customize a Pipes and Structures report but am having difficulty changing the % slope column to run over rise.
View 2 Replies
View Related
Aug 19, 2011
I am trying to create a table that will incorporate info from structures and pipes. In C3d 2010 I want to make a CB chart which will show the pipe size, starting structure and invert. I would also like to include the CB rim elevation but that would be under the structure table. Is there any way I can combine the RIm elevation with the pipe table?
View 4 Replies
View Related
Nov 19, 2013
I oftenly do conception for parkings and always need to have the calculated rentention of water volume in the pipe network.is there a way to have that information with Civil 3d ?
Googled the subject and i only found a topic on trench's for the pipes ...
Cyberflow
Using : Autodesk Civil 3D 2012
OS : Windows 7 - 64 bit pro
View 3 Replies
View Related
Apr 20, 2011
Is there a way to label multiple structures/pipes at one time in profile view? We have tried selecting all at one time, right click and add label, but it only labels one of the structures/pipes.
View 4 Replies
View Related
Nov 12, 2010
Is there a way to show the deflection angle between incoming and outgoing pipes in a structure label? Or any label at all, for that matter? I know it can be done with alignments at the PI point, but only in the source drawing.
View 1 Replies
View Related
Dec 7, 2012
I am using Civil 3D 2013. I work in an office where we have a few different flavors of Autocad (LT, MEP, regular vanilla AutoCAD etc...) and versions (2010 LT, 2011, 2012, 2013).
For the most part there isn't much inter-office drawing coordinate that has to happen, but there is the occasional project where multiple disciplines (Structural, Mechanical and Civil Site) have to share drawings.
The specific problem I am having is when I share my 2013 Civil 3D drawing with a user using 2011 MEP. He gets the typical rectangle for the proxy objects (in my case, my pipe networks for sanitary and storm drain). We've tried downloading and installing various object enablers, but there doesn't seem to be one for a 2013 to 2011 scenario. So I setup my parts to be on layers that he can just turn off. HOWEVER... the actual pipe network (not the structures, parts, labels etc... the network itself) ends up on layer 0. For this specific project, I do the old (ssget "x" '((8 . "0")) search to select all objects on layer 0, add those objects to a selection set (pselect), then in my modify objects dialog I filter for pipe networks, then change the layer to something other then 0.
While this is a workaround that works for me, what I really want to know is if there is a way that I can change the default layer that the network (again, not pipes, structures or text, the actual network) so I don't have to use the workaround. Any thoughts?
P.S. It's killing me that I had to create a new Autodesk login and now all my AutoCAD "street cred" is lost
"The source of expertise is not in the memorization of the minute details of a subject but in the thorough understanding of the fundamental concepts on which it is based."
View 9 Replies
View Related
Aug 23, 2013
I received some dwg files to show existing utilities from a local municipality. I thought the files would come as shp files, but they are dwg files. The drawings/dwg files show the layout of pipes, but the pipes are polylines. The polylines have data attached to them. The properties show material, size, length, slope, etc. I am trying to label the pipes/polylines and I can't figure out how to get the information from the polylines.
View 4 Replies
View Related
Dec 13, 2013
How do I label spanning pressure pipes? I can do it in a pipe network, but not a pressure pipe network.
View 1 Replies
View Related
Mar 4, 2013
In the case of a pipe network structure, where one pipe is circular (say 60") and the other pipe is box (say 5'x4'), how can you get the "connected pipes" label to reflect [size in feet X size in feet] for the box pipe and [size in inches] for the circular pipe?
I don't see how you can conditionally affect a portion of the "connected pipes" label since it's one label object.
View 9 Replies
View Related
Dec 5, 2012
I have pipe crossings shown in my profile. Only crossings (NO PROJECTIONS). So many elipises. I want to label them. Setting the label style at the pipe network does not work (will not override whatever label style was assigned at the pipe creation). I have accepted this (although it sucks).
Now, to get around it, I go Pipe>Add Label>Add Pipe Network Label. Label type is "Entire Network Profile". When I do this, it labels not only the crossings but all projections. So I have a million labels chilling out in space, where I have no crossing.
View 1 Replies
View Related
Dec 29, 2011
A way to change the display order of pipes connected to the structure in a structure label? (plan and profile) Say you have a 10", 6" and 12" pipe connected to a structure, modeled in that order, so label would place them 10, 6, 12. we would like the label to display the order as 6,10, then 12 without having to drag the pipes off and then having to re-input inverts.
View 6 Replies
View Related
May 8, 2012
The label associated to a grading point when is moved when is moved changes its size automatically and a leader appears. After this happen no control over the grading point and its associate label. refer to the image below.
View 1 Replies
View Related
Sep 26, 2013
Any way to label a pipe part way between structures? I would like to be able to label a sanitary line where a service ties in with the main line invert.
C3D 2013
View 7 Replies
View Related
Jul 17, 2013
I've placed generic Junction box structures right out of the box from C3D and when I cut a section, the section shows the wrong side of the structure. (Rotated) i.e. An inserted 60”x36” junction box inserted as a curb inlet and then rotated into position will display the 60” side even though it’s perpendicular to the section line.
I've had to go back and place a 36”x60” to get it to display the 36” side in section? Why is there a “rotation handle” on the structure if you can’t really rotate it?I really don't want to swap all 60"x36" with 36"x60" structures just so they will display properly in section.
View 2 Replies
View Related
May 21, 2013
I'm currently working on a very large Dwg, with multiple pipe networks both sanitary, Storm and pressure pipe.
I need to create a .csv file for all my structures for Stakeout. I know I can go into my toolbox and create a report through the reports manager. The problem is that its giving me too much information, all I want is PNEZD. How can I create this report or edit that report being generated?
View 3 Replies
View Related
Sep 26, 2013
I am labeling structures in a network on the profile view. I cannot get the leader when i drag the label to anchor to the top of the structure? Is there a way to do this, i figured out how to have the label insert at the middle of the top line of the structure.
Civil 2014-Infrastructure Design Suite
Windows 7 Professional-SP 1-64 bit system
Intel Core i5-2500K cpu @ 3.3ghz
NVIDIA GeForce GT 430
8.0 gb ram
View 1 Replies
View Related
Nov 21, 2012
Seems to happen randomply, but my structures and labels disappear when synchronizing.
View 7 Replies
View Related
Jun 25, 2013
I have set the migration defaults to my part list and the pipes come in as expected but all the structures come in as null? I even went as far as setting every option to my rect junction NF and they still come in as null?
View 2 Replies
View Related
Jul 18, 2013
I have added a pipe network to my profile view and for some reason the structures do not extend down to the inverts of the pipe. So the pipes are lower than the structures. I tried changing the sump, and the rim to sump (rim to sump can be editted but immediately goes back to what it originally was when you click apply. I've also tried clicking the structure and extending it downwards but it doesn't change. I've tried changing the stye and still have the same issue.
View 4 Replies
View Related
Nov 23, 2012
in situation i can draw only a structure only. When i want to draw a pipe-there nothing happens. Is possibly that i erase something in Part builder command?
View 2 Replies
View Related
Aug 26, 2010
My storm drain profiles will not plot the structures if I publish. They plot ok if I use the plot command, but I'd like to be able to publish.
View 4 Replies
View Related
May 9, 2012
Any way to easily identify what labels structures use? I have a plan and profile drawing drawing with 15 diferent layouts. Another guy worked on it and edited the contents on one of the profile structure labels. So now I'm going to have to go through each layout and looking for what structure labels would have been changed. Typicaly if there is a slight difference in the callout for one structure I'll just edit the label text for that one particular structure.
I would like to select (sweep) all the structures in profile and see which ones would have used this particular label style.
View 1 Replies
View Related
Sep 6, 2012
C3D 2013. We have profile line labels, some of which get manually edited (for example, change the "<[Tangent grade(FP|P2|RN|AP|GC|UN|SD|OF)]>" to a static number such as 0.29%).
However, if you CTRL+Click and select one of these labels and change the style of that one label, then the manual edits are lost and the label reverts back to the default string.
Is there any way to turn this behavior off?
View 1 Replies
View Related
Jan 3, 2013
Is there a way to "Edit Label Text" in a Parcel area label? Similar to the way you can edit it in other styles.
View 9 Replies
View Related
Feb 10, 2012
I can change it under structure properties, but I can't find where to change it before I make the pipe network , 2013 Civil 3D.
View 2 Replies
View Related
May 8, 2012
I would like the Leader Attachment for a structure in dragged state to be at the bottom of the top line. I have underlined the top line and would like the leader to extend from the underline.
Is there a way to add a "bottom of the top line" to the pull down menu, or control the leader attachment point in another way?
View 2 Replies
View Related
Oct 21, 2013
Can you set pipe structures and assign your own rim elevation? I don't want to use surface elevation.
View 1 Replies
View Related
May 22, 2012
Is there any way to associate multiple pipe structures to one alignment. I spend half my time re-associating structures to alignments.
View 1 Replies
View Related