AutoCAD Civil 3D :: Labeling Structures In A Network?

Sep 26, 2013

I am labeling structures in a network on the profile view.  I cannot get the leader when i drag the label to anchor to the top of the structure?  Is there a way to do this, i figured out how to have the label insert at the middle of the top line of the structure.

Civil 2014-Infrastructure Design Suite
Windows 7 Professional-SP 1-64 bit system
Intel Core i5-2500K cpu @ 3.3ghz
NVIDIA GeForce GT 430
8.0 gb ram

View 1 Replies


ADVERTISEMENT

AutoCAD Civil 3D :: Default Pipe Network Layer (Not The Structures Or Pipes The Network)

Dec 7, 2012

I am using Civil 3D 2013. I work in an office where we have a few different flavors of Autocad (LT, MEP, regular vanilla AutoCAD etc...) and versions (2010 LT, 2011, 2012, 2013).

For the most part there isn't much inter-office drawing coordinate that has to happen, but there is the occasional project where multiple disciplines (Structural, Mechanical and Civil Site) have to share drawings.

The specific problem I am having is when I share my 2013 Civil 3D drawing with a user using 2011 MEP. He gets the typical rectangle for the proxy objects (in my case, my pipe networks for sanitary and storm drain). We've tried downloading and installing various object enablers, but there doesn't seem to be one for a 2013 to 2011 scenario. So I setup my parts to be on layers that he can just turn off. HOWEVER... the actual pipe network (not the structures, parts, labels etc... the network itself) ends up on layer 0. For this specific project, I do the old (ssget "x" '((8 . "0")) search to select all objects on layer 0, add those objects to a selection set (pselect), then in my modify objects dialog I filter for pipe networks, then change the layer to something other then 0.

While this is a workaround that works for me, what I really want to know is if there is a way that I can change the default layer that the network (again, not pipes, structures or text, the actual network) so I don't have to use the workaround. Any thoughts?

P.S. It's killing me that I had to create a new Autodesk login and now all my AutoCAD "street cred" is lost

"The source of expertise is not in the memorization of the minute details of a subject but in the thorough understanding of the fundamental concepts on which it is based."

View 9 Replies View Related

AutoCAD Civil 3D :: Labeling A Pipe Between Structures

Sep 26, 2013

Any way to label a pipe part way between structures? I would like to be able to label a sanitary line where a service ties in with the main line invert.

C3D 2013

View 7 Replies View Related

AutoCAD Civil 3D :: Labeling Multiple Structures / Pipes In Profile View

Apr 20, 2011

Is there a way to label multiple structures/pipes at one time in profile view? We have tried selecting all at one time, right click and add label, but it only labels one of the structures/pipes.

View 4 Replies View Related

AutoCAD Civil 3D :: Pipe Network Labeling

Jun 11, 2013

I have a drainage model, the data for which has been imported from microdrainage into Civil3d (.sws file) .

The engineer working on the project is playing around with the Invert and Cover levels so I reload the same updated .sws file into my model almost daily expecting the information shown in the labels of the pipes and manholes to simply change. Instead mine seem to disappear and I have to relabel the whole network again.

This wouldn't be much of a problem because labeling only takes a few minutes but with this particular scheme, the client wants the labels shown in a box with a leader. When I relabel, the boxes automatically snap to the center of the manholes without a leader and i then have to drag each one away from the manhole to get the leader to show up.

View 7 Replies View Related

AutoCAD Civil 3D :: Creating Points From Pipe Network Structures?

Jul 31, 2012

is there a quick way to create & export points from a pipe network? i've probably got 100 or so structures that need points with the correct structure name in the point description.

Dell Studio XPS 9100
Intel Core i7 CPU 930 @ 2.8GHz
12GB Ram
64 bit
C3D 2012 SP3.0

View 2 Replies View Related

AutoCAD Civil 3D :: Pipe Network Total Volume Of Pipes And Structures

Nov 19, 2013

I oftenly do conception for parkings and always need to have the calculated rentention of water volume in the pipe network.is there a way to have that information with Civil 3d ?

Googled the subject and i only found a topic on trench's for the pipes ...

Cyberflow
Using : Autodesk Civil 3D 2012
OS : Windows 7 - 64 bit pro

View 3 Replies View Related

AutoCAD Civil 3D :: Structures Rotated In Section?

Jul 17, 2013

I've placed generic Junction box structures right out of the box from C3D and when I cut a section, the section shows the wrong side of the structure. (Rotated)  i.e. An inserted 60”x36” junction box inserted as a curb inlet and then rotated into position will display the 60” side even though it’s perpendicular to the section line.

I've had to go back and place a 36”x60” to get it to display the 36” side in section? Why is there a “rotation handle” on the structure if you can’t really rotate it?I really don't want to swap all 60"x36" with 36"x60" structures just so they will display properly in section.

View 2 Replies View Related

AutoCAD Civil 3D :: Create CSV File For All Structures

May 21, 2013

I'm currently working on a very large Dwg, with multiple pipe networks both sanitary, Storm and pressure pipe.

I need to create a .csv file for all my structures for Stakeout. I know I can go into my toolbox and create a report through the reports manager.  The problem is that its giving me too much information, all I want is PNEZD.  How can I create this report or edit that report being generated?

View 3 Replies View Related

AutoCAD Civil 3D :: Structures Disappear During Synchronizing?

Nov 21, 2012

Seems to happen randomply, but my structures and labels disappear when synchronizing. 

View 7 Replies View Related

AutoCAD Civil 3D :: Structures Import As Null

Jun 25, 2013

I have set the migration defaults to my part list and the pipes come in as expected but all the structures come in as null? I even went as far as setting every option to my rect junction NF and they still come in as null?

View 2 Replies View Related

AutoCAD Civil 3D :: Cannot Extend Structures In Profile

Jul 18, 2013

I have added a pipe network to my profile view and for some reason the structures do not extend down to the inverts of the pipe. So the pipes are lower than the structures. I tried changing the sump, and the rim to sump (rim to sump can be editted but immediately goes back to what it originally was when you click apply. I've also tried clicking the structure and extending it downwards but it doesn't change. I've tried changing the stye and still have the same issue.

View 4 Replies View Related

AutoCAD Civil 3D :: Cannot Draw A Pipe Only Structures

Nov 23, 2012

in situation i can draw only a structure only. When i want to draw a pipe-there nothing happens. Is possibly that i erase something in Part builder command?

View 2 Replies View Related

AutoCAD Civil 3D :: Can't Label Certain Pipes / Structures

Mar 7, 2012

why I can't label certain pipes/structures?  I can select the pipe or structure, rt click, add label and I get nothing.  The layer is on cause I can see other labels. I also get the same result when I go to annotation, pipe label.   This only happenes to certain pipes or structure, others in the same network label fine.

View 9 Replies View Related

AutoCAD Civil 3D :: Structures Not Plotting With Publish

Aug 26, 2010

My storm drain profiles will not plot the structures if I publish. They plot ok if I use the plot command, but I'd like to be able to publish.

View 4 Replies View Related

AutoCAD Civil 3D :: Identify What Labels Structures Use?

May 9, 2012

Any way to easily identify what labels structures use? I have a plan and profile drawing drawing with 15 diferent layouts. Another guy worked on it and edited the contents on one of the profile structure labels. So now I'm going to have to go through each layout and looking for what structure labels would have been changed. Typicaly if there is a slight difference in the callout for one structure I'll just edit the label text for that one particular structure.

I would like to select (sweep) all the structures in profile and see which ones would have used this particular label style.

View 1 Replies View Related

AutoCAD Civil 3D :: Deflection Angle Label For Structures

Nov 12, 2010

Is there a way to show the deflection angle between incoming and outgoing pipes in a structure label? Or any label at all, for that matter? I know it can be done with alignments at the PI point, but only in the source drawing.

View 1 Replies View Related

AutoCAD Civil 3D :: Pipes And Structures - Max HGL Exceeding Elev Of Rim

Aug 22, 2012

In a run of pipes and structures, I have 3 structures that overflow.  2 of the structures max hgl els are even with the rim elevation (as is in the case of other runs in the same project), and 1 structure has the max hgl exceeding the elev of the rim.  Why this one and not the others?

View 2 Replies View Related

AutoCAD Civil 3D :: Converting Pipes And Structures Catalogs?

Oct 11, 2013

I'm trying draw profile, I see "compile error can't find project or library",

then I select "convert VBA pipe and structure rules to .NET" it works until I turn off civil 3d

how to do, that it works for everytimes?

View 3 Replies View Related

AutoCAD Civil 3D :: Customizing Pipes And Structures Report

May 24, 2012

I am attempting to customize a Pipes and Structures report but am having difficulty changing the % slope column to run over rise.

View 2 Replies View Related

AutoCAD Civil 3D :: How To Change The Sump Default Value For Structures

Feb 10, 2012

I can change it under structure properties, but I can't find where to change it before I make the pipe network , 2013 Civil 3D.

View 2 Replies View Related

AutoCAD Civil 3D :: Leader Attachment Options For Structures

May 8, 2012

I would like the Leader Attachment for a structure in dragged state to be at the bottom of the top line.  I have underlined the top line and would like the leader to extend from the underline.

Is there a way to add a "bottom of the top line" to the pull down menu, or control the leader attachment point in another way?

View 2 Replies View Related

AutoCAD Civil 3D :: Set Pipe Structures And Assign Own Rim Elevation?

Oct 21, 2013

Can you set pipe structures and assign your own rim elevation?  I don't want to use surface elevation.  

View 1 Replies View Related

AutoCAD Civil 3D :: Associate Multiple Structures To One Alignment

May 22, 2012

Is there any way to associate multiple pipe structures to one alignment. I spend half my time re-associating structures to alignments.

View 1 Replies View Related

AutoCAD Civil 3D :: Contour Labeling

Jul 10, 2012

I have recreated two surfaces for my design, existing and proposed.  I had used polylines for contours for in each surface.  I tried labeling the contours but it will not let me select the contour itself. 

I then tried to make the contours to 3d polylines and again added them to the surface and rebuilt.  I still am not allowed to label the contour since it doesn't let me select the polyline.  I am able to select the surface however. 

View 1 Replies View Related

AutoCAD Civil 3D :: Storm Sewers Migrating Null Structures?

Jun 25, 2013

I have set the migration defaults to my part list and the pipes come in as expected but all the structures come in as null? I even went as far as setting every option to my rect junction NF and they still come in as null? What did I miss?

Civil 3D 2012 & 2013
HP Z210 Workstation
Intel Xeon CPU E31240 @ 3.30 Hz
12 GB Ram
64 Bit Win7 OS

View 5 Replies View Related

AutoCAD Civil 3D :: Import STM Change Sump Level Of Structures

Oct 4, 2013

I am struggling to import .stm file into a blank civil3d file. it does import whith correct sizes and elevation. the issue is rim level of structures are the same as SSA file but it will make 2 meter sump depth to stuctures, thus structures invert levels are not correct. i just made a sump depth rule for structure and applied to some of them. it will correct it but as i have more than 1000 manholes in network it will be a major job to apply the rule. i know "apply rule" command will work a lot but i would like to know why it is importing whit wrong properties?

View 3 Replies View Related

AutoCAD Civil 3D :: Pipe Between Structures Only Has Location / Diameter Snaps?

Jun 14, 2013

So I have a proposed storm sewer pipe network and 90% of pipes snap to the structures fine, with a start/lengthen snap on one end and an end/lengthen on the other, and a location/pipe diameter one in the middle. When I go to draw one of the pipes though, I draw structure to structure and it doesn't sit properly. I click on it to make sure it snapped to the structure but there is no start, end, or lengthen snaps on either end of the pipe. Only a Location/Pipe Diameter one in the middle. Therefore, I cannot manipulate it's length or where it connects, I can only move it around from the center.

View 5 Replies View Related

AutoCAD Civil 3D :: Pipe Structures On Non-plotting Layer Still Plot

Feb 21, 2012

When I'm drawing in pipe networks I like to use a user created block for structures. I do this by manually inserting the block I need (DI, MH, etc.) at each structure location. Since there are different blocks for different structures, having the structure itself display as a user block via the structure style isn't really an option since it will display the same block for all structures unless you make a style for each type of structure. So I like to have my structures set to display on a non-plotting layer via the style display layers. This way I can still select and modify its properties, but it won't show up on a plot.

My question is: If the style display layer is a non-plotting layer, why is the "object layer" (0 layer in the case) overwriting the display layer and causing the structure outline to plot?

If I put the display layers of the pipes onto a non-plotting layer, they will not plot even if the object layer is a plotting layer. The workaround so far is to select all the structures and set their object layer to a non-plotting layer, but this is not ideal.

View 9 Replies View Related

AutoCAD Civil 3D :: Labeling Deflections On Alignment

Feb 9, 2012

I read through the previous posts but still I am not able to do this. I am using C3D 2012.

What I need to do is label Deflection angles of an alignment (delta angle). The alignment does not have any curve. 

So basically it will be some kind of PI or geometry point label showing the deflection angle. 

Labelling LT or RT would be great but at this time I dont need that. 

I hope it explains. 

View 9 Replies View Related

AutoCAD Civil 3D :: Labeling Surface Section

Oct 8, 2013

I want to label the surface sections (eg, fg) in a single location something like what is shown in the attached image.

Currently I am using a major offset label which refers to the surface description* where the surface name is stored. I set the increment to a suitable number which results in multiple labels along the section. I then drag one into position and delete the rest using ctrl-select. While it would be far easier to use multileaders to acheive the correct look, they don't update location with the section views.

We use the description to store the 'friendly' name as our object naming standard wouldn't necessarily make sense to the viewer of the plans.

View 8 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved