AutoCAD Civil 3D :: Label Pipes / Polylines

Aug 23, 2013

I received some dwg files to show existing utilities from a local municipality. I thought the files would come as shp files, but they are dwg files. The drawings/dwg files show the layout of pipes, but the pipes are polylines. The polylines have data attached to them. The properties show material, size, length, slope, etc. I am trying to label the pipes/polylines and I can't figure out how to get the information from the polylines.

View 4 Replies


ADVERTISEMENT

AutoCAD Civil 3D :: Can't Label Certain Pipes / Structures

Mar 7, 2012

why I can't label certain pipes/structures?  I can select the pipe or structure, rt click, add label and I get nothing.  The layer is on cause I can see other labels. I also get the same result when I go to annotation, pipe label.   This only happenes to certain pipes or structure, others in the same network label fine.

View 9 Replies View Related

AutoCAD Civil 3D :: How To Label Spanning Pressure Pipes

Dec 13, 2013

How do I label spanning pressure pipes?  I can do it in a pipe network, but not a pressure pipe network.

View 1 Replies View Related

AutoCAD Civil 3D :: Structure Label When There Is Mix Of Circular And Box Pipes

Mar 4, 2013

In the case of a pipe network structure, where one pipe is circular (say 60") and the other pipe is box (say 5'x4'), how can you get the "connected pipes" label to reflect [size in feet X size in feet] for the box pipe and [size in inches] for the circular pipe?

I don't see how you can conditionally affect a portion of the "connected pipes" label since it's one label object.

View 9 Replies View Related

AutoCAD Civil 3D :: Pipes - Label Entire Network Profile / Want Crossings Only

Dec 5, 2012

I have pipe crossings shown in my profile.  Only crossings (NO PROJECTIONS).  So many elipises.  I want to label them.  Setting the label style at the pipe network does not work (will not override whatever label style was assigned at the pipe creation).  I have accepted this (although it sucks).

Now, to get around it, I go Pipe>Add Label>Add Pipe Network Label.  Label type is "Entire Network Profile".  When I do this, it labels not only the crossings but all projections.  So I have a million labels chilling out in space, where I have no crossing.

View 1 Replies View Related

AutoCAD Civil 3D :: Display Order Of Connected Pipes In Structure Label

Dec 29, 2011

A way to change the display order of pipes connected to the structure in a structure label? (plan and profile) Say you have a 10", 6" and 12" pipe connected to a structure, modeled in that order, so label would place them 10, 6, 12.  we would like the label to display the order as 6,10, then 12 without having to drag the pipes off and then having to re-input inverts.

View 6 Replies View Related

AutoCAD Civil 3D :: Point Label Size Change When Label Is Moved?

May 8, 2012

The label associated to a grading point when is moved when is moved changes its size automatically and a leader appears. After this happen no control over the grading point and its associate label. refer to the image below.

View 1 Replies View Related

AutoCAD Civil 3D :: Changing Profile Line Label Style Causes Label String To Revert To Default

Sep 6, 2012

C3D 2013. We have profile line labels, some of which get manually edited (for example, change the "<[Tangent grade(FP|P2|RN|AP|GC|UN|SD|OF)]>" to a static number such as 0.29%).

However, if you CTRL+Click and select one of these labels and change the style of that one label, then the manual edits are lost and the label reverts back to the default string.

Is there any way to turn this behavior off?

View 1 Replies View Related

AutoCAD Civil 3D :: Edit Label Text In Parcel Label

Jan 3, 2013

Is there a way to "Edit Label Text" in a Parcel area label? Similar to the way you can edit it in other styles.

View 9 Replies View Related

AutoCAD Civil 3D :: Label Profile Label Stations As Raw

Aug 8, 2013

I'm trying to label my Profile label stations as raw stations, 20~20 meters, and I'm not being able to adapt the format to STATION 0, STATION 2, without any plus zeros or +, or -, or commas, or anything, as following in the image.

Is there a easy way to do it?

View 2 Replies View Related

AutoCAD Civil 3D :: How To Add Pressure Pipes

Apr 17, 2013

I've been able to publish and then import valves, flange adaptors etc. with no problem, but if I create a flanged (metric) pipe using the Content Catalog Editor and then draw the pipe in C3D it shows blank ends, no flanges. I've split the pipe in the drawing to see if that forces flanges to appear, but nothing.

Do I need to create the flanges seperately and then add them to the end of pipes?

I'm using Civil 3D 2013

View 1 Replies View Related

AutoCAD Civil 3D :: Inner Diameter Of Pipes In SSA

Sep 30, 2013

I am modelling a sewer pipe network in SSA. At some stages we use varies pipe materials with different wall thicknesses. So I want to know how can I assign inner diameter of pipes in SSA so I just deduct wall thickness from pipe diameter and then assign it to the pipe. Or is there any possibility to make a pipe list with specific properties like part builder in civil3d?

View 5 Replies View Related

AutoCAD Civil 3D :: Breaking Pipes?

Nov 4, 2013

Is there any way to split a pipe (in a non-pressure network) in two?

View 2 Replies View Related

AutoCAD Civil 3D :: Pipes In Profile

Apr 21, 2013

why when i mesure the pipe diam  prependicular in profile its less than the accurat dimension of the pipe whoever i changed the profile vertical exaggeration to 1, it still wrong? when mesured virtical it is ok

View 8 Replies View Related

AutoCAD Civil 3D :: Pipes With Box Culverts

Jul 5, 2013

I have a 8'x7' Box culvert with manholes. The manhole needs to sit on top of the 8'x7' boxes. I also want to see the pipe drawn from center of manhole to center of manhole. not stop at manhole wall.

[URL]....

View 2 Replies View Related

AutoCAD Civil 3D :: Multi Barrel Pipes

Nov 24, 2013

What the best way to draw multiple parallel pipes that cross a corridor.  In my example I have a track with 4 pipes crossing the track corridor on slightly different alignments (from perpendicular to skewed).  I have drawn the pipes on as individual pipes under the same network.

However I cannot get them all to display on the profile.  I have tried "Draw Parts in Profile" but it seems to bring up only 1 pipe. managing multiple pipes.

View 3 Replies View Related

AutoCAD Civil 3D :: Crossing Pipes In Profile?

Mar 12, 2012

I have two pipe networks and two profile views, one for storm and another for sanitary.  I would like to show the crossing pipes on each of the profile views.  When I select the profile view, add a pipe and change the style to crossing the style is change to crossing on the other profile view (ex. on sanitary profile view I set storm pipe 3 to crossing style, on the storm profile pipe 3 changes to crossing style and does not display).  Isn't there a way to display the styles for pipes different in each profile view?

C3D 2011 (latest updates)
Win 7 Pro, 64-bit
16 GB RAM

View 3 Replies View Related

AutoCAD Civil 3D :: Pipes Extending Beyond Profile?

Jun 22, 2009

I have a profile with a couple of pipe networks in it. One of the pipes shown extends beyond the edge of the profile at some crazy angle. look at the picture for a better explanation.

View 5 Replies View Related

AutoCAD Civil 3D :: Pipes Will Not Show Up In Drawing

Apr 25, 2013

When I try to make a pipe network the structures are visible but the pipes are not present.  I thawed all layers with no success. This is a recent development because It was working last week.

View 2 Replies View Related

AutoCAD Civil 3D :: Drawing Pipes In Profile

Sep 17, 2013

How to do profiles in Civil3D and I have created a profile from the surface utilizing a miscellaneous alignment. I have also taken one 12"RCP and made it part of a network along with the catch basin and manhole at its start and end. When I click "draw parts in profile" it places both structures and the pipe, but in reality only a portion of the pipe crosses the alignment. I'd like to only display portions of pipes that cross the alignment at a fixed width form that alignment, say 2' to each side of it.

View 9 Replies View Related

AutoCAD Civil 3D :: Pipes Table In Excel?

May 22, 2006

I have a number of tables which have all properties about the pipe network with the cooridnates and upstream/ downstream info. Can it import to C3D and automatically generate the pipe to 3D?

View 9 Replies View Related

AutoCAD Civil 3D :: Existing Vs Proposed Pipes

Jun 3, 2013

I'm a bit of a Civil 3D newbie.  I've got a project that involves addition of storm drain to existing storm pipes.  I'd like to be able to use Civil 3D to include existing and proposed pipes in the networks, but be able to show existing pipes differently than proposed pipes on plans and profiles, i.e. screened. I can't seem to figure out a way to do this--I can effect changes to all networks, but not invididual pipes.

View 9 Replies View Related

AutoCAD Civil 3D :: Pipes In Profile View?

Apr 5, 2013

Is there a way (and I'm just missing it) to have a pipe from a pipe network only be shown 'cut-off', with the typical 'cut-off' shown on the profile view?  see the screen shot of sketch of what I'm referring to. 

View 2 Replies View Related

AutoCAD Civil 3D :: Optional Properties For Pipes

Jul 8, 2013

Back in 2010, I created several optional properties in pipes for labeling purposes.

The file I modified is: AeccPartParamCfg.xml

I have migrated this file to 2011, 2012, 2013 without any issue. In 2014, I am getting a run time error for one of the optional properties and therefore that option is no longer working.

Created optional properties and run into problems in 2014? Works fine in all my previous releases of Civil 3D using the same parameter file. 

Attached is the Parameter file and error at start up.

View 3 Replies View Related

AutoCAD Civil 3D :: Pin A Label To Another Label

May 17, 2013

Is it possible to pin a label to another label ? Or pin a label to an object so that when the first label (or object) is moved, the other moves with it ?

View 2 Replies View Related

AutoCAD Civil 3D :: Profile Data Bands For Pipes?

May 15, 2012

In order to have a data band at the bottom of my profile label the station and invert of my sewer pipe I just created a profile along the pipe and then have a data band in my profile that labels that profile.  I have that profile style set to not plot so this way I can leave it on all the time.  This is all fine and well.  I have labels every 100' that label the station and invert elevation but at times I want to label miscellaneous locations along my pipe such as a bend or something.  How do I add an addition data band label to achieve this?  Everything I have found only lets me have these labels at a specified increment set in the band style.

View 2 Replies View Related

AutoCAD Civil 3D :: VBA - How To Access Pipes Hydraulic Data

Jul 12, 2012

How can I access the hydraulic data from pipes through VBA? Is it possible? I couldn't find this information in the pipes object...

Using Building Design Suite Ultimate 2014

View 6 Replies View Related

AutoCAD Civil 3D :: Unable To Attach Two Pipes To Headwall?

Aug 20, 2011

I have been unable to attach two pipes to a headwall.  Tried to make the headwall wide enough but each pipe still overlapped.  My current work around is to use two headwalls. Is there a way to get the double pipes with a single headwall?  or am I stuck with two headwalls.

View 5 Replies View Related

AutoCAD Civil 3D :: Inlet Control Not Checked For Pipes?

Sep 11, 2012

After testing a simple culvert and pipe, it appears that inlet control is not checked for pipes.  Does this mean that I have to model all storm sewers in a network as culverts just to check inlet control?

View 2 Replies View Related

AutoCAD Civil 3D :: Pipe Networks With Multiple Pipes?

Mar 15, 2013

Is it possible to simultaneously create a pipe network with multiple pipes?

View 5 Replies View Related

AutoCAD Civil 3D :: Profile Hatching From FG To Top Of Pipes - 2013

Feb 28, 2013

Is there a way for C3D 2013 to automatically hatch (with a style) in the profile view the area from the FG to top of pipes (Sanitary, Storm or Water). Currently we go old school with isolating the linework in the profile and hatching it manually. The interesting thing is the hatch still recognizes the grid in the profile view even though we've frozen the grid and other linework. AND we must put a line on the top of the pipe, or the hatching goes to the next "grid" of the profile.

Would be nice to get it to generate the hatch much the same way it does for the profile view with Cut area or Fill area or Multi boundaries.

View 2 Replies View Related