AutoCAD Civil 3D :: Inlet Control Not Checked For Pipes?

Sep 11, 2012

After testing a simple culvert and pipe, it appears that inlet control is not checked for pipes.  Does this mean that I have to model all storm sewers in a network as culverts just to check inlet control?

View 2 Replies


ADVERTISEMENT

AutoCAD Civil 3D :: What Structure To Use To Model Yard Inlet

Jul 10, 2013

what structure to use to model yard inlet?

View 5 Replies View Related

AutoCAD Civil 3D :: Multiple Inverts From Junction / Inlet In SSA

Jan 24, 2013

I am working on drainage for a median storm sewer, culverts and ditching for a large freeway expansion project.  I have median storm sewers running down my entire roadway (about 5kms).  I have manually inputed the upstream and downstream elevations of the pipes in SSA, but when these pipes are connected to an inlet or junction, I only have the option of selecting one invert elevation for each structure (I am actually using a lot of catchbasin manholes in this project, which I am unsure of SSA's ability to model).  I have multiple drops of varying elevation differences throughout the project, with some of these inlets/junction requiring drop structures due to the large difference in elevation change.  How do I properly model this in SSA?

View 7 Replies View Related

AutoCAD Civil 3D :: ERROR 600 - Inlet Doesn't Have Two Outlets

Oct 17, 2012

I do not have two outlet from 4 different intakes. The four intake are modeled as on-grading intake and do have both a bypass link and pipe line attached. Attached is the model that I have been working with. The intake causing the problems are:

EX.I-01
EX.I-02
EX.I-05
EX.I-06

View 1 Replies View Related

AutoCAD Civil 3D :: Inlet-01 Doesn't Have Two Outlet Links

May 8, 2013

On grade Inlet Inlet-01 does not have two outlet links. At least one stormwater sewer pipe and a bypass gutter link must be defined.How do I add another link?

View 1 Replies View Related

AutoCAD Civil 3D :: How Sump Inlet Depth / Spread Calculated

Jun 7, 2013

Any hydraflow calculates depth of flow and spread at sump inlets?  Does it assume that the entire flow is coming from one direction (similar to an on-grade inlet)? Or does it make an assumption about how much flow is coming into both ends of the inlet?

View 4 Replies View Related

AutoCAD Civil 3D :: Area (On Sag) Inlet - Correct Head Relationship

Nov 29, 2012

The SSA literature states to use an On Sag inlet to model an inlet used in the middle of a parking lot.

This is more commonly known as an "Area Inlet" application, and is also used in areas such as airport runways, greenbelts and golf courses.

To develop the correct operating head relationship over the grate, we need to be able to enter a stage-storage curve starting from the grate elevation. This will develop the "cone" shape storage needed to develop the correct head elevation over the grate.

It appears looking at the On Sag options there is only the Ponded Area parameter available; the same parameter found in a Junction. This calculates the head elevation as a function of the ponded volume and a constant area.
 
I want to confirm that the On Sag inlet application used as an Area inlet, is using all four sides, full perimeter = 2(L+W),  of the inlet for the weir flow calculations before orifice flow controls, not just 3 sides as a grate on a curb. 

C3D 2014 SP1
W7x64; i7 8gb; Radeon HD 5700

View 2 Replies View Related

AutoCAD Civil 3D :: Inlet Bypass And Street Section Modeling

Jun 27, 2012

We recently began experimenting with SSA and are trying to verify the inlet calculations that were done in excel to make sure we understand the software before putting it into everyday use. We've created a custom parabolic street section and applied it to the bypass links, and as far as that aspect goes, we understand it and it's all working great.

How to model inlets directly across from each other in a street section. The issues arise when the top width (of Inlet 1, in the attached graphic, for example) exceeds the half section width and flows over the crown into the opposite side of the street (to Inlet 2, in attached graphic).

We have tried weirs and flow diversions to no avail. Attached is an example of what I'm trying to explain. Inlets 1 and 2 are opposite from each other, and both connect into a MH labeled SD-J 29+33.00. Link-05 connects to the next downstream MH, and there are 2 links that follow the gutter lines to the North used as bypass links from Inlets 1 & 2.

Civil 3D 2014
Windows 7 Professional
Intel Xeon E31270 @ 3.4 GHz
8 GB, 64-bit

View 3 Replies View Related

AutoCAD Civil 3D :: Structure Label - Pipe Inlet And Outlet Elevation

Dec 10, 2013

I would like to know if it is possible to display the pipe inlet/outlet elevation in my structure label. It seems like it is not possible.It is possible to use the inlet/outlet elevation of the pipe in my pipe label however I would like to display it in my structure.

View 2 Replies View Related

AutoCAD Civil 3D :: Error 607 / Inlet A9 Gutter Capture Curve Is Not A Valid Curve

Dec 31, 2013

I have ran an analysis and SSA gave me Error 607  on the report. It says "Inlet A9 gutter capture curve is not a valid curve."

A couple things I did different from the video lectures...

I selected user define for the Tc to figure out Q. i computed those manually.

For the Inlets I have selected Maximum Capture Cutoff.

There are some inlets in this model I created that do not capture 100% of the flow so i created conveyance links to account for the bypass flow.Not sure why is not recognizing the Curve?

View 9 Replies View Related

AutoCAD Civil 3D :: How To Add Pressure Pipes

Apr 17, 2013

I've been able to publish and then import valves, flange adaptors etc. with no problem, but if I create a flanged (metric) pipe using the Content Catalog Editor and then draw the pipe in C3D it shows blank ends, no flanges. I've split the pipe in the drawing to see if that forces flanges to appear, but nothing.

Do I need to create the flanges seperately and then add them to the end of pipes?

I'm using Civil 3D 2013

View 1 Replies View Related

AutoCAD Civil 3D :: Inner Diameter Of Pipes In SSA

Sep 30, 2013

I am modelling a sewer pipe network in SSA. At some stages we use varies pipe materials with different wall thicknesses. So I want to know how can I assign inner diameter of pipes in SSA so I just deduct wall thickness from pipe diameter and then assign it to the pipe. Or is there any possibility to make a pipe list with specific properties like part builder in civil3d?

View 5 Replies View Related

AutoCAD Civil 3D :: Breaking Pipes?

Nov 4, 2013

Is there any way to split a pipe (in a non-pressure network) in two?

View 2 Replies View Related

AutoCAD Civil 3D :: Pipes In Profile

Apr 21, 2013

why when i mesure the pipe diam  prependicular in profile its less than the accurat dimension of the pipe whoever i changed the profile vertical exaggeration to 1, it still wrong? when mesured virtical it is ok

View 8 Replies View Related

AutoCAD Civil 3D :: Pipes With Box Culverts

Jul 5, 2013

I have a 8'x7' Box culvert with manholes. The manhole needs to sit on top of the 8'x7' boxes. I also want to see the pipe drawn from center of manhole to center of manhole. not stop at manhole wall.

[URL]....

View 2 Replies View Related

AutoCAD Civil 3D :: Get Profile Start And End Labels To Appear Even After Checked Label Start Station

Feb 22, 2012

I can't seem to get my profile start and end station labels to appear even after I checked "Label start station" and "label end station" in the profile view properties.

View 2 Replies View Related

AutoCAD Civil 3D :: Multi Barrel Pipes

Nov 24, 2013

What the best way to draw multiple parallel pipes that cross a corridor.  In my example I have a track with 4 pipes crossing the track corridor on slightly different alignments (from perpendicular to skewed).  I have drawn the pipes on as individual pipes under the same network.

However I cannot get them all to display on the profile.  I have tried "Draw Parts in Profile" but it seems to bring up only 1 pipe. managing multiple pipes.

View 3 Replies View Related

AutoCAD Civil 3D :: Crossing Pipes In Profile?

Mar 12, 2012

I have two pipe networks and two profile views, one for storm and another for sanitary.  I would like to show the crossing pipes on each of the profile views.  When I select the profile view, add a pipe and change the style to crossing the style is change to crossing on the other profile view (ex. on sanitary profile view I set storm pipe 3 to crossing style, on the storm profile pipe 3 changes to crossing style and does not display).  Isn't there a way to display the styles for pipes different in each profile view?

C3D 2011 (latest updates)
Win 7 Pro, 64-bit
16 GB RAM

View 3 Replies View Related

AutoCAD Civil 3D :: Pipes Extending Beyond Profile?

Jun 22, 2009

I have a profile with a couple of pipe networks in it. One of the pipes shown extends beyond the edge of the profile at some crazy angle. look at the picture for a better explanation.

View 5 Replies View Related

AutoCAD Civil 3D :: Pipes Will Not Show Up In Drawing

Apr 25, 2013

When I try to make a pipe network the structures are visible but the pipes are not present.  I thawed all layers with no success. This is a recent development because It was working last week.

View 2 Replies View Related

AutoCAD Civil 3D :: Drawing Pipes In Profile

Sep 17, 2013

How to do profiles in Civil3D and I have created a profile from the surface utilizing a miscellaneous alignment. I have also taken one 12"RCP and made it part of a network along with the catch basin and manhole at its start and end. When I click "draw parts in profile" it places both structures and the pipe, but in reality only a portion of the pipe crosses the alignment. I'd like to only display portions of pipes that cross the alignment at a fixed width form that alignment, say 2' to each side of it.

View 9 Replies View Related

AutoCAD Civil 3D :: Pipes Table In Excel?

May 22, 2006

I have a number of tables which have all properties about the pipe network with the cooridnates and upstream/ downstream info. Can it import to C3D and automatically generate the pipe to 3D?

View 9 Replies View Related

AutoCAD Civil 3D :: Existing Vs Proposed Pipes

Jun 3, 2013

I'm a bit of a Civil 3D newbie.  I've got a project that involves addition of storm drain to existing storm pipes.  I'd like to be able to use Civil 3D to include existing and proposed pipes in the networks, but be able to show existing pipes differently than proposed pipes on plans and profiles, i.e. screened. I can't seem to figure out a way to do this--I can effect changes to all networks, but not invididual pipes.

View 9 Replies View Related

AutoCAD Civil 3D :: Pipes In Profile View?

Apr 5, 2013

Is there a way (and I'm just missing it) to have a pipe from a pipe network only be shown 'cut-off', with the typical 'cut-off' shown on the profile view?  see the screen shot of sketch of what I'm referring to. 

View 2 Replies View Related

AutoCAD Civil 3D :: Can't Label Certain Pipes / Structures

Mar 7, 2012

why I can't label certain pipes/structures?  I can select the pipe or structure, rt click, add label and I get nothing.  The layer is on cause I can see other labels. I also get the same result when I go to annotation, pipe label.   This only happenes to certain pipes or structure, others in the same network label fine.

View 9 Replies View Related

AutoCAD Civil 3D :: Label Pipes / Polylines

Aug 23, 2013

I received some dwg files to show existing utilities from a local municipality. I thought the files would come as shp files, but they are dwg files. The drawings/dwg files show the layout of pipes, but the pipes are polylines. The polylines have data attached to them. The properties show material, size, length, slope, etc. I am trying to label the pipes/polylines and I can't figure out how to get the information from the polylines.

View 4 Replies View Related

AutoCAD Civil 3D :: Optional Properties For Pipes

Jul 8, 2013

Back in 2010, I created several optional properties in pipes for labeling purposes.

The file I modified is: AeccPartParamCfg.xml

I have migrated this file to 2011, 2012, 2013 without any issue. In 2014, I am getting a run time error for one of the optional properties and therefore that option is no longer working.

Created optional properties and run into problems in 2014? Works fine in all my previous releases of Civil 3D using the same parameter file. 

Attached is the Parameter file and error at start up.

View 3 Replies View Related

AutoCAD Civil 3D :: Profile Data Bands For Pipes?

May 15, 2012

In order to have a data band at the bottom of my profile label the station and invert of my sewer pipe I just created a profile along the pipe and then have a data band in my profile that labels that profile.  I have that profile style set to not plot so this way I can leave it on all the time.  This is all fine and well.  I have labels every 100' that label the station and invert elevation but at times I want to label miscellaneous locations along my pipe such as a bend or something.  How do I add an addition data band label to achieve this?  Everything I have found only lets me have these labels at a specified increment set in the band style.

View 2 Replies View Related

AutoCAD Civil 3D :: VBA - How To Access Pipes Hydraulic Data

Jul 12, 2012

How can I access the hydraulic data from pipes through VBA? Is it possible? I couldn't find this information in the pipes object...

Using Building Design Suite Ultimate 2014

View 6 Replies View Related

AutoCAD Civil 3D :: Unable To Attach Two Pipes To Headwall?

Aug 20, 2011

I have been unable to attach two pipes to a headwall.  Tried to make the headwall wide enough but each pipe still overlapped.  My current work around is to use two headwalls. Is there a way to get the double pipes with a single headwall?  or am I stuck with two headwalls.

View 5 Replies View Related

AutoCAD Civil 3D :: Pipe Networks With Multiple Pipes?

Mar 15, 2013

Is it possible to simultaneously create a pipe network with multiple pipes?

View 5 Replies View Related