Back in 2010, I created several optional properties in pipes for labeling purposes.
The file I modified is: AeccPartParamCfg.xml
I have migrated this file to 2011, 2012, 2013 without any issue. In 2014, I am getting a run time error for one of the optional properties and therefore that option is no longer working.
Created optional properties and run into problems in 2014? Works fine in all my previous releases of Civil 3D using the same parameter file.
Attached is the Parameter file and error at start up.
In 2013, I had an optional part parameter for pipes called "Velocity", and it worked fine. We use a network catalog, and I was trying to use the same part catalog for 2014, but it gave me a Runtime Part Parameter Configuration Error for the Parameter Name "VEL". So I copied the "Pipes Catalog" folder from my C drive for 2014 and pasted it to the network. I then revised the AeccPartParamCfg.xml in the AeccShared Content folder with the same information as I had in the previous network catalog.
Specifically, I added the following line in the xml file
I added the line "<AeccOptParam context="FlowVelocity"/>"
see the attached image 1-Old AeccPartParamCfg xml file.JPG to see images from the xml file.
I got the same error when I opened C3D 2014. I added an underscore between Flow and Velocity for context, and it worked! (See attachment 2-Revised AeccPartParamCfg xml file.JPG)
So C3D 2014 opens without the error. I click on Part Builder and click on RCP (formerly Concrete Pipe from OOTB part catalog) under pipes. I right click on Size Parameters and click "Add..." which takes me to the New Parameter dialog box as seen in attachment 3.JPG. It shows three of the optional properties I have added: Pipe Classification, Friction Slope, and Velocity.
I add these three optional properties and edit their configurations as seen in attachment 3.JPG. I give Friction Slope and Velocity both a range of 0 to 1000 with a default of 0.
I create a new parts list and add the part family RCP. I click to add part sizes and get the final dialog box on attachment 3.JPG. Velocity doesn't show up! Pipe Classification and Friction Slope show up, but no velocity!
I have tried deleting the 'VEL" line in the xml file, copying the "FSL" line and pasting and revising it for velocity, but that didn't work. I tried switching the FSL and VEL lines in the xml file to see if FSL would disappear and VEL would appear, but that had no effect.
the properties palette started only showing the current properites for the drawing and not the properties of the entity selected. what causes this i am using autocad civil 3d 2013.
For the last couple weeks I've been unable to view object properties or quick properties. If I right click on an object and select quick properties, a blank window comes up:
Similarly, if I bring up a properties window and select an object, the selection field remains blank and the object property fields are not populated with information relating to the selected object:
I've been able to publish and then import valves, flange adaptors etc. with no problem, but if I create a flanged (metric) pipe using the Content Catalog Editor and then draw the pipe in C3D it shows blank ends, no flanges. I've split the pipe in the drawing to see if that forces flanges to appear, but nothing.
Do I need to create the flanges seperately and then add them to the end of pipes?
I am modelling a sewer pipe network in SSA. At some stages we use varies pipe materials with different wall thicknesses. So I want to know how can I assign inner diameter of pipes in SSA so I just deduct wall thickness from pipe diameter and then assign it to the pipe. Or is there any possibility to make a pipe list with specific properties like part builder in civil3d?
why when i mesure the pipe diam prependicular in profile its less than the accurat dimension of the pipe whoever i changed the profile vertical exaggeration to 1, it still wrong? when mesured virtical it is ok
I have a 8'x7' Box culvert with manholes. The manhole needs to sit on top of the 8'x7' boxes. I also want to see the pipe drawn from center of manhole to center of manhole. not stop at manhole wall.
What the best way to draw multiple parallel pipes that cross a corridor. In my example I have a track with 4 pipes crossing the track corridor on slightly different alignments (from perpendicular to skewed). I have drawn the pipes on as individual pipes under the same network.
However I cannot get them all to display on the profile. I have tried "Draw Parts in Profile" but it seems to bring up only 1 pipe. managing multiple pipes.
I have two pipe networks and two profile views, one for storm and another for sanitary. I would like to show the crossing pipes on each of the profile views. When I select the profile view, add a pipe and change the style to crossing the style is change to crossing on the other profile view (ex. on sanitary profile view I set storm pipe 3 to crossing style, on the storm profile pipe 3 changes to crossing style and does not display). Isn't there a way to display the styles for pipes different in each profile view?
I have a profile with a couple of pipe networks in it. One of the pipes shown extends beyond the edge of the profile at some crazy angle. look at the picture for a better explanation.
When I try to make a pipe network the structures are visible but the pipes are not present. I thawed all layers with no success. This is a recent development because It was working last week.
How to do profiles in Civil3D and I have created a profile from the surface utilizing a miscellaneous alignment. I have also taken one 12"RCP and made it part of a network along with the catch basin and manhole at its start and end. When I click "draw parts in profile" it places both structures and the pipe, but in reality only a portion of the pipe crosses the alignment. I'd like to only display portions of pipes that cross the alignment at a fixed width form that alignment, say 2' to each side of it.
I have a number of tables which have all properties about the pipe network with the cooridnates and upstream/ downstream info. Can it import to C3D and automatically generate the pipe to 3D?
I'm a bit of a Civil 3D newbie. I've got a project that involves addition of storm drain to existing storm pipes. I'd like to be able to use Civil 3D to include existing and proposed pipes in the networks, but be able to show existing pipes differently than proposed pipes on plans and profiles, i.e. screened. I can't seem to figure out a way to do this--I can effect changes to all networks, but not invididual pipes.
Is there a way (and I'm just missing it) to have a pipe from a pipe network only be shown 'cut-off', with the typical 'cut-off' shown on the profile view? see the screen shot of sketch of what I'm referring to.
why I can't label certain pipes/structures? I can select the pipe or structure, rt click, add label and I get nothing. The layer is on cause I can see other labels. I also get the same result when I go to annotation, pipe label. This only happenes to certain pipes or structure, others in the same network label fine.
I received some dwg files to show existing utilities from a local municipality. I thought the files would come as shp files, but they are dwg files. The drawings/dwg files show the layout of pipes, but the pipes are polylines. The polylines have data attached to them. The properties show material, size, length, slope, etc. I am trying to label the pipes/polylines and I can't figure out how to get the information from the polylines.
In order to have a data band at the bottom of my profile label the station and invert of my sewer pipe I just created a profile along the pipe and then have a data band in my profile that labels that profile. I have that profile style set to not plot so this way I can leave it on all the time. This is all fine and well. I have labels every 100' that label the station and invert elevation but at times I want to label miscellaneous locations along my pipe such as a bend or something. How do I add an addition data band label to achieve this? Everything I have found only lets me have these labels at a specified increment set in the band style.
I have been unable to attach two pipes to a headwall. Tried to make the headwall wide enough but each pipe still overlapped. My current work around is to use two headwalls. Is there a way to get the double pipes with a single headwall? or am I stuck with two headwalls.
After testing a simple culvert and pipe, it appears that inlet control is not checked for pipes. Does this mean that I have to model all storm sewers in a network as culverts just to check inlet control?
Is there a way for C3D 2013 to automatically hatch (with a style) in the profile view the area from the FG to top of pipes (Sanitary, Storm or Water). Currently we go old school with isolating the linework in the profile and hatching it manually. The interesting thing is the hatch still recognizes the grid in the profile view even though we've frozen the grid and other linework. AND we must put a line on the top of the pipe, or the hatching goes to the next "grid" of the profile.
Would be nice to get it to generate the hatch much the same way it does for the profile view with Cut area or Fill area or Multi boundaries.
In a run of pipes and structures, I have 3 structures that overflow. 2 of the structures max hgl els are even with the rim elevation (as is in the case of other runs in the same project), and 1 structure has the max hgl exceeding the elev of the rim. Why this one and not the others?
I've got a weird problem with pipes in 2014. When I edit a pipe (right-click Pipe Properties) and make a change, when I press OK or Apply, the pipe SIZE changes? It's still listed as a 300mm PVC, but it's being represented as a 410mm? Look at the attached image. The storm (green) shoes a 300mm pipe and 375. The 375 is smaller? The pipe style (as you can see int he image, is set to display the inside pipe walls.
Nothing is unique here about the pipe sizes, this is a stock pipe catalog. But the size doesn't really change, only how the pipe is drawn in the profile. I've never seen something like this before. It measures .418m instead of .3m.
I have a job where there are 3 round pipes and one elliptical pipe going into the same structure. When I put a label on the structure, it shows all 4 pipes, but I can't figure a way to show the elliptical pipe dimensions as 29x45; It only comes in as 45" RCP. I have tried to manipulated the text, but it won't let me me change the individual pipe text in the structure label. When I change the label to read Height x Width, the round pipes show the same as elliptical pipe. Is there a way for my label to show 3 round and 1 elliptical pipe size, or do I have to manually add the elliptical pipe size (which I'd prefer not to do)?
We've had a little nagging problem that we've just been living with, but getting a little tired of it: when building a pipe network the plotted line will stop plotting at the outter wall of the structure, thus leaviung a gap between the pipe and the structure. On a 48" manhole it's hardly noticable, but when the manhole gets larger, so does the problem. Check out the attached pdf and you'll see what I'm talking about.
I've been through all the style setting I can think of, but I thought there might be a variable to take care of it...like the FACETDEV variable for crossing pipe.
I am trying to create a pressure pipe network (right now I have 2 pipes) and have it follow a surface. When I click to follow surface it lowers the vertices but does not add any additional vertices to make the entire pipe network 5' below surface. My pipe lengths are set to 18' and the surface I want to use is set in my network properties.