AutoCAD Civil 3D :: How To Model Two Pipes Coming Out Of A Structure
Oct 17, 2013
I am trying to model a system of existing storm pipes, where the last catch basin actually has two outfalls: one an 18" pipe and the other a 24" pipe. They have different invert elevations.
I have the pipes set up correctly in Autocad, so that the profile shows up right, and the plan view in Storm Sewers shows up right, too. However, the model does not separate the flows.
Is there a way to manually enter the approximate amount of flow that will discharge through each pipe?
View 1 Replies
ADVERTISEMENT
Mar 6, 2012
We've had a little nagging problem that we've just been living with, but getting a little tired of it: when building a pipe network the plotted line will stop plotting at the outter wall of the structure, thus leaviung a gap between the pipe and the structure. On a 48" manhole it's hardly noticable, but when the manhole gets larger, so does the problem. Check out the attached pdf and you'll see what I'm talking about.
I've been through all the style setting I can think of, but I thought there might be a variable to take care of it...like the FACETDEV variable for crossing pipe.
View 1 Replies
View Related
Mar 4, 2013
In the case of a pipe network structure, where one pipe is circular (say 60") and the other pipe is box (say 5'x4'), how can you get the "connected pipes" label to reflect [size in feet X size in feet] for the box pipe and [size in inches] for the circular pipe?
I don't see how you can conditionally affect a portion of the "connected pipes" label since it's one label object.
View 9 Replies
View Related
Dec 29, 2011
A way to change the display order of pipes connected to the structure in a structure label? (plan and profile) Say you have a 10", 6" and 12" pipe connected to a structure, modeled in that order, so label would place them 10, 6, 12. we would like the label to display the order as 6,10, then 12 without having to drag the pipes off and then having to re-input inverts.
View 6 Replies
View Related
Jul 10, 2013
what structure to use to model yard inlet?
View 5 Replies
View Related
Nov 4, 2011
We use C3D 2012 (metric only) - We are attempting to customize our list of structures for Sanitary Sewers. The structure list shows sizes we do not use and we would like to modify them. However, when we try to select the "Inner Diameter" it displays a list of sizes that we can not seem to modify or add to.
I have looked at some of the XML files to try and modify or add new sizes (example: AeccStructConcentricCylinder_Metric.xml) , but they do not seem to be recognized even after I restart the program.
Here is what the file looks like:
<ColumnConstList desc="Inner Structure Diameter" dataType="float" unit="mm" name="SID" id="CCL1" visible="1" context="StructInnerDiameter" index="0">
<Item id="i0">1200.0000</Item>
<Item id="i1">1350.0000</Item>
<Item id="i2">1500.0000</Item>
<Item id="i3">1800.0000</Item>
<Item id="i4">2050.0000</Item>
<Item id="i5">2300.0000</Item>
<Item id="i6">2550.0000</Item>
I tried modifying the last line replacing 2550 with 3600.
I also tried adding a line <Item id="i7">3600.0000</Item>
I saved the XML file and restarted the program with nothing changing that I can see.
Looking for correct file(s) to edit so I can modify the LISTS that come up in the piping modules.
View 2 Replies
View Related
Feb 12, 2008
One good thing about null structures is the way they display in 3D. They cover that gap in the pipe segments. Can I steal that shape?
I am currently using a simple cylinder for water pipe "joints" and turning it off like most people do I think.
View 4 Replies
View Related
Apr 30, 2012
I have drawn a pipe network with multiple concentric sturctures. I need to make them all eccentric now. Is there an easy quick way to do this, or do I have to redraw all of them. When I go to the properties, I cannot find an option that allows me to change this.
View 2 Replies
View Related
Dec 23, 2011
I am starting to model pipes for placement within assemblies.I could model the pipe and flanges in 1 part file but i thought this would take too long to create each flange individually so i modeled the pipe and flanges as separate part files and constrained them in a assembly file. How would you tackle this pipe work?
Future pipes will have different size/type flanges on a pipe depending on how it connects.
Is it possible to make the pipe in a single part file with the flange on 1 of the ends and with a command operation then move the flange to the others pipe ends?
View 5 Replies
View Related
Apr 18, 2012
sectioning.jpg
I want to model a parametric structure by acad architecture, but I don't have any clue, can you tell me the way to do this ?
View 9 Replies
View Related
Oct 8, 2013
The cross section at the culdesac is not coming right (attached). Instead of a gradual slope, i get a drop near the centerline. I am targeting to the CL alignment and profile.
View 3 Replies
View Related
Apr 17, 2013
I've been able to publish and then import valves, flange adaptors etc. with no problem, but if I create a flanged (metric) pipe using the Content Catalog Editor and then draw the pipe in C3D it shows blank ends, no flanges. I've split the pipe in the drawing to see if that forces flanges to appear, but nothing.
Do I need to create the flanges seperately and then add them to the end of pipes?
I'm using Civil 3D 2013
View 1 Replies
View Related
Sep 30, 2013
I am modelling a sewer pipe network in SSA. At some stages we use varies pipe materials with different wall thicknesses. So I want to know how can I assign inner diameter of pipes in SSA so I just deduct wall thickness from pipe diameter and then assign it to the pipe. Or is there any possibility to make a pipe list with specific properties like part builder in civil3d?
View 5 Replies
View Related
Nov 4, 2013
Is there any way to split a pipe (in a non-pressure network) in two?
View 2 Replies
View Related
Apr 21, 2013
why when i mesure the pipe diam prependicular in profile its less than the accurat dimension of the pipe whoever i changed the profile vertical exaggeration to 1, it still wrong? when mesured virtical it is ok
View 8 Replies
View Related
Jul 5, 2013
I have a 8'x7' Box culvert with manholes. The manhole needs to sit on top of the 8'x7' boxes. I also want to see the pipe drawn from center of manhole to center of manhole. not stop at manhole wall.
[URL]....
View 2 Replies
View Related
Dec 21, 2012
I'm now working on my diploma work and I need to model a gridshell construction in Conceptual mass.I created the form and made adaptive component -a glass panel.I uploaded it in the family and now I need to load that family into the project space and I don't know what to do..I will have to remove the mass eventually before rendering but then the gridshell structure will disappear.I don't know how to make it real,I cannot use massing and site with this, I'm obviously missing some steps and i don't know which ones..
View 1 Replies
View Related
Nov 24, 2013
What the best way to draw multiple parallel pipes that cross a corridor. In my example I have a track with 4 pipes crossing the track corridor on slightly different alignments (from perpendicular to skewed). I have drawn the pipes on as individual pipes under the same network.
However I cannot get them all to display on the profile. I have tried "Draw Parts in Profile" but it seems to bring up only 1 pipe. managing multiple pipes.
View 3 Replies
View Related
Mar 12, 2012
I have two pipe networks and two profile views, one for storm and another for sanitary. I would like to show the crossing pipes on each of the profile views. When I select the profile view, add a pipe and change the style to crossing the style is change to crossing on the other profile view (ex. on sanitary profile view I set storm pipe 3 to crossing style, on the storm profile pipe 3 changes to crossing style and does not display). Isn't there a way to display the styles for pipes different in each profile view?
C3D 2011 (latest updates)
Win 7 Pro, 64-bit
16 GB RAM
View 3 Replies
View Related
Jun 22, 2009
I have a profile with a couple of pipe networks in it. One of the pipes shown extends beyond the edge of the profile at some crazy angle. look at the picture for a better explanation.
View 5 Replies
View Related
Apr 25, 2013
When I try to make a pipe network the structures are visible but the pipes are not present. I thawed all layers with no success. This is a recent development because It was working last week.
View 2 Replies
View Related
Sep 17, 2013
How to do profiles in Civil3D and I have created a profile from the surface utilizing a miscellaneous alignment. I have also taken one 12"RCP and made it part of a network along with the catch basin and manhole at its start and end. When I click "draw parts in profile" it places both structures and the pipe, but in reality only a portion of the pipe crosses the alignment. I'd like to only display portions of pipes that cross the alignment at a fixed width form that alignment, say 2' to each side of it.
View 9 Replies
View Related
May 22, 2006
I have a number of tables which have all properties about the pipe network with the cooridnates and upstream/ downstream info. Can it import to C3D and automatically generate the pipe to 3D?
View 9 Replies
View Related
Jun 3, 2013
I'm a bit of a Civil 3D newbie. I've got a project that involves addition of storm drain to existing storm pipes. I'd like to be able to use Civil 3D to include existing and proposed pipes in the networks, but be able to show existing pipes differently than proposed pipes on plans and profiles, i.e. screened. I can't seem to figure out a way to do this--I can effect changes to all networks, but not invididual pipes.
View 9 Replies
View Related
Apr 5, 2013
Is there a way (and I'm just missing it) to have a pipe from a pipe network only be shown 'cut-off', with the typical 'cut-off' shown on the profile view? see the screen shot of sketch of what I'm referring to.
View 2 Replies
View Related
Mar 7, 2012
why I can't label certain pipes/structures? I can select the pipe or structure, rt click, add label and I get nothing. The layer is on cause I can see other labels. I also get the same result when I go to annotation, pipe label. This only happenes to certain pipes or structure, others in the same network label fine.
View 9 Replies
View Related
Aug 23, 2013
I received some dwg files to show existing utilities from a local municipality. I thought the files would come as shp files, but they are dwg files. The drawings/dwg files show the layout of pipes, but the pipes are polylines. The polylines have data attached to them. The properties show material, size, length, slope, etc. I am trying to label the pipes/polylines and I can't figure out how to get the information from the polylines.
View 4 Replies
View Related
Jul 8, 2013
Back in 2010, I created several optional properties in pipes for labeling purposes.
The file I modified is: AeccPartParamCfg.xml
I have migrated this file to 2011, 2012, 2013 without any issue. In 2014, I am getting a run time error for one of the optional properties and therefore that option is no longer working.
Created optional properties and run into problems in 2014? Works fine in all my previous releases of Civil 3D using the same parameter file.
Attached is the Parameter file and error at start up.
View 3 Replies
View Related
Mar 4, 2013
I am having an issue inserting a detail call out "block". The blocks were created to be annotative however, when I am inserting them into my paperspace at 1" = 30' it shrinks up the block. In model space it shows at the correct size.
View 2 Replies
View Related
Jul 15, 2013
I'm in a dwg that had broken references. I right clicked on Alignments to repair all broken references. Everything came in (surfaces, alignments, pipe networks) but text did not come in from a source drawing; the Source Dwg is a Pipe Network. The network came in but not the text. I opened the source dwg & the text is there. The Event Viewer is showing no broken references so what I'm I missing?
View 5 Replies
View Related
May 15, 2012
In order to have a data band at the bottom of my profile label the station and invert of my sewer pipe I just created a profile along the pipe and then have a data band in my profile that labels that profile. I have that profile style set to not plot so this way I can leave it on all the time. This is all fine and well. I have labels every 100' that label the station and invert elevation but at times I want to label miscellaneous locations along my pipe such as a bend or something. How do I add an addition data band label to achieve this? Everything I have found only lets me have these labels at a specified increment set in the band style.
View 2 Replies
View Related