The beam is continuous. The connection details are not important. They're some kind of plate welded to the beam and bolted through the column web. I don't need it to be able to do structural calculations.
Join won't select a structural column or beam. Align creates a rotation error because of the beam's pitch. The column height appears to only change by the Level, but again the beam is pitched. Setting the height above the beam breaks the beam.
I am creating a beam system. I click the "beam system" button on the structure panel. However, it then goes into sketch mode without stopping to allow me to select "automatic beam system" and/or "Tag on Placement." Fortunately, I can see that "automatic beam system" is already selected in the split second that flashes before going to sketch mode.
However, I do not have the opportunity to select the "Tag on Placement." I am really new to Revit and thus I am wondering if there is a different way to possibly turn on the tagging since the way I know is not an option.
This is quite weird because revit architecture 2013 is showing this error. In order to see beam in my architectural layout, we are changing the cut plane value in the view range. With this step I can see the beam but not the cut pattern of the beam..very weird. Also, one more thing, just to check I copy pasted beam modeled in revit 2011 in revit 2013 and I could see the cut pattern. So is something wrong with 2013 beam revit family?
I've been screwing around with beams in Revit for years and still have issues with the gaps at the connections. There is a shape handle and a structural component end. Either way, the beam decides where it wants to end. If I put two precast beams end to end, resting on an inverted tee girder that needs to have the 9" tee portion extend between the two joists, Revit doesn't like that and does its own thing. I move one, the other follows. I move both far enough away from eachother, then drag one end to where it needs to be, cool, then when I drag the other...boom...they snap together. Yes, I'm aware of the "start and end extension" in the properties window, this is incredibly time consuming and if one of the beams are switched around, I need to remember if this end was the start or end. In addition, the structural component end will go initially where it wants to, so there's no guarantee that if the parameters are correct, the beam/joist will be.
Can I remove all "rules" that beams have so I can place these correctly?
If i draw a beam in plan view en define the height, the beam disepare. Is there a posibility that the beam is in place and you can see a dash dot line and two dashed lines in plan view?
How can we calculate the formwork of column & beam? Is it possible to add "Height" parameter in Column. Because we add formula into the Family file as below:
Perimeter = (2*Depth+2*Width) Formwork Area = Perimeter*Height
I try to 'lock' a beam system that I have used for rafters to the underside of my roof.I've successfully got the walls and gables linked in with the roof, and have set up reference planes for cutting of rafters (that should - I think - mean that rafters can move slightly - or change pitch, whilst maintaining same cut extents at rafter ends).
Trouble is - the rafter Beam System does not update with the roof.
My creation approach for the Beam System was to select the underside of the roof as the 'Working Plane' - then edit the boundary to project beyond the walls and form the overhang. I projected it further than I required to provide the excess needed in case I wanted to push the cut plane outwards.
I assumed that selecting the underside of the roof as the working plane would 'lock' the two together, but it doesn't appear to work.Have I missed a straightforward step to link the two elements together ?
The attached schedule is all good except that I want to get a total for the columns Duplex, Duplex GFI, Fourplex and Simplex. The schedule only shows the (1) column at the moment Duplex Total created as an additional paramter with calculated totals in the project. I am trying to link that to the Duplex column etc...,
Please note that those columns Duplex, Duplex GFI, Fourplex, and Simplex are graphical yes/no paramters for my all in one outlet family created using the annotation symbols separatey loaded in a 3d wall hosted electrical family then turned off and on accordingly.
It's all working nicely expect that the different heights are counting separately, when I want a total of just Duplex's, Simplex's and so forth.
Revit Architecture 2014? I've been trying to use the structural beam system, but when I select the joist I cannot select the start/end extension in the properties dialog box. I would like to know why is that?
When splitting a schedule, the title of the schedule shows up above each of the columns created. Is there a way of having it so that when you slit a schedule in multiple columns, the title centeres over the entire view and shows itself only once instead of once over each column?
I am having issues with not being able to put in a column on an angle when using Revit Architecture. I read a troubleshoot guide and you can do it using Revit Structure, however Architecture is a different story.Why is this, and more importantly how can I put a column in on an angle.
1) Why structural columns don't show up in architectural plans. The only way I can see to coordinate the structure with the architectural elements is to use structural plans.
2) How to make structural columns visible in architectural plans? I've tried the visibility graphics but everything seems to be turned on by default.
I got trouble connecting my exterior wall to the roof or in other words, it would be good, if the insulating layer would not be pierced by concrete (-:
How can I connect two computers in sync with the Autodesk 360? So when you change the properties of an item element in one computer to another feature of the modified element synchronized.
I currently have a situation in white my stair handrail mid post wont connect to my stair stringer. I have a C10 stair stringer and am using a modified typer square handrail system I have made. I am sure there is a setting or preference I have missed that is causing this. I have attached an image for reference.
ALSO in the image you can see the top rail does not fully attach to the end post. It sits in the middle somehow. AND that end post sits halfway off the stringer.
i have been a long user of romcat... but would like to use the new corel connect. i use the folders selected to my HD folder that has all my cdr files (20yrs worth from ver 1). when i type in a search word that is in 100's of my cdr files keywords... connect doesnt display them. In romcat it does display them, even older files, with the same key word. connect only shows cdr files that have in its file name part of the search word, but seems to ignore the key words in the files.
I have all my job files with important key words within them, but the actual file names are simple job numbered names. i noticed on searches from X5 content on dvd, the files also are just numbers, but the search finds key words.
I would like to know how to create a beam of fire....or an object surrounded by a ring of fire.....not unlike one in strych9ine's avatar. Maybe he would be able to explain it better.
When I try to calculate bending moment stress thru "Beam and column calcultor it shows an error that is Wk and Jk is missing. Ok that is fine. If we put values for both we will get the answer. Because I have come to know thru inv discussion that many material in the CC do not have these values.
Now my question is when we insert a part for example from content centre (CC) and do FEA analysis on this part. It shows some values like deflection, stress etc etc. How is that possible? one side it is not doing in the beam calculatio but other side in FEA it is doing that.
It means we are not going to rely upon these results in the FEA. It is the same CC, same inventor, how should be trust the result in FEA.