Revit :: Show Level Of Cut On Profile As Reference Line Automatically?
Oct 2, 2012
How to show the level of cut on the profile as reference line automatically?
I’m wondering if there is a way to show the level of cut automatically on the elevation view.
Software: AutoCAD 2014, AutoCAD C3D, AutoCAD M3D, Revit
Windows 7 (Ultimate 64 bits),
Firefox 20.0,
Kaspersky 2013.
View 2 Replies
ADVERTISEMENT
Jun 18, 2013
The underlay does not show up for Level 1 when I am on Level 2, but it does show up for Level 2 when I am on Level 1. the underlay option is on for Level 1, so I'm not sure why it's not showing up. I am using Revit 2014.
View 1 Replies
View Related
Dec 28, 2011
I need to add "Level" into my Cable Tray schedule; we need to sort the cable trays lengths by floor level. However, "Level" is not listed as one of the available fields, even though level information (show up as "Reference Level) is one of the constraints in the cable tray model.
View 1 Replies
View Related
Aug 6, 2012
I am working on a project with Split Levels like a Multi-level CarPark. I need to produce plans by combining two Levels which are at 3M height difference.
While using Plan Region, Some of the walls dont show as cut, though their height is more & above the Cut Plane Level.
I did find a quick solution online here - [URL] ... This trick is still not working for some of the walls..
View 1 Replies
View Related
Apr 9, 2012
I noticed that Revit likes to show the entire stair going down. This works for me in a lot of cases but I have a project that the second floor is showing the stair all the way down to the first floor, and there is another stair going from the second floor to the third that I really need to see.
Plan regions don't seem to allow me to add a break line below the second floor and see the stair from the second to the third floor. The floors are on and the view is set to hidden.
The attached png shows the up stairs in blue that I would like to see and the Down stairs I would like to cut at the landing.
View 3 Replies
View Related
Aug 2, 2011
Why are my Level Lines highlighted green?
Also why do some of the level symbols appear blue?
Searched and find, how to change the colors of the types, not why they are displaying in other colors than black.
View 3 Replies
View Related
Apr 17, 2013
I am currently working on a project and i created a land plot and set each level line to the proper elevation but not all of the level lines appear in every view. In the North view all of the level lines and the walls i have created appear, but the walls don't show up in any of the other views. Also the North, West, and South views show all of the level lines but the East view does not.
View 1 Replies
View Related
Jan 14, 2014
The project I am working on includes revit data produced from a point cloud. The file I was given has two levels. The first level is fine however; the second level is set 1 foot too high. When I adjust the level elevation (drop it down by 1 foot), all of the elements associated with level two move with it. What I want to do is move the level line without adjusting the associated revit items.
View 3 Replies
View Related
Dec 19, 2012
I just created a wall sweep on a wall , but I noticed the sweep doesn't adjust to the wall profile, please see the second floor wall in the attached image. Is there anyway to make the sweep adjust to the profile of the wall automatically?
View 2 Replies
View Related
May 23, 2011
I have a line based generic model family I use for wall framing and for some reason separate instances of the family will automatically join together when the ends are within a few inches of eachother. How the heck do I turn that option off? Why would it automatically join in the first place? I have tried to unjoin geometry and it wont select the families.
It is acting like the way walls will autojoin but there are no options to disable this. It makes something that should be simple very tedious and annoying.
Windows 7
RAC2012
View 3 Replies
View Related
Nov 15, 2012
How do I show high level walkways and balconies (in dashed outline) on the ground floor plan in a high volume space?
Obviously I can turn the first floor RCP on in the view and manually draw the information, but I assume these lines won't move if the walkways above move (or am I wrong?). Also this seems slightly wrong given the amount of automation available.
View 4 Replies
View Related
Jul 16, 2007
I am having a little trouble with some doors showing up on the level 1 door schedule that are actually on level 2. They are curtain wall doors.
View 6 Replies
View Related
Jan 18, 2012
Is there a way to show the edge of the riser finish as a hidden line in plan?
Also the edge of nosing against the riser to be shown as a hidden line in plan?
View 1 Replies
View Related
May 16, 2012
by default revit shows roof plan in the Site plan view.
Is it possible to show site plan that one line would represent building contour? Also is it possible to cast shadows of all the building if the first floor is selected?
i was trying to make site plan from the fist floor, but since i gave intense topography ground is being cut and i need full topography. i am using 2013 revit.
View 2 Replies
View Related
Jan 29, 2014
I'm trying to align a nested family to a reference line in my host family so that it rotates around a certain point.
I've created the reference line in my host family, locked the end point to two reference planes and then gave an angular parameter to the angle between the ref. line and the ref. plane.
I then inserted the nested family and aligned it to the ref. line. The problem is that when I flex the angle, i get a "Constraints not satisfied" error..
What could be wrong?
I'm using a generic face based family for both host and nested families...
Using Building Design Suite Ultimate 2014
View 3 Replies
View Related
Nov 11, 2013
What i say in the title is what i'm doing manually right now for 30 levels!
I'm building different color tshirt previews, every level represents a color and there's a level on top with the draw to be printed.
If I can do it automatically I'll have lot of time saved!
View 6 Replies
View Related
Jan 24, 2012
how to make the lines of a reference part that are in effect acting as hidden lines become removed from a view?
We've tried making the part phantom...which isn't right as we need the line representation of the part to be as the reference linestyle...
We've tried changing variables & tick boxes in the edit view dialogue boxes...but nothing works...
View 7 Replies
View Related
Jan 6, 2014
How can i create a profile using level data obtained from dumpy level with civil3D
View 3 Replies
View Related
Jun 22, 2012
I tried to use shortcut Ctrl+L to access Level... But, my Photoshop Elements 9 did not respond and the Level window did not show up.
View 5 Replies
View Related
Mar 31, 2012
have a problem with the settings of the graylevel profile. RGB and CMYK works fine, but graylevel does not. If I change the modus from RGB to graylevel, white (255, 255, 255) becomes a light yellow (255, 254, 220). Black (0, 0, 0,) becomes (1, 1, 1,).
The monitor is calibrated and there is no color problem. White is white and black is black (as usual). It's just the graylevel gamut in photoshop.
RGB: Samsung Natural Color (rgb profile of my monitor)
CMYK: not important
Gray: Dot gain 10% (I tried every profil but I always got the same result. White becomes a light yellow).
Look at the screenshot, you will see the difference between rgb and graylevel: [URL]...
View 1 Replies
View Related
Jun 28, 2012
The intersection wizard makes dynamic EOP profiles based off of the cross slope from the centerline. Well the intersection tool doesn't always work with funky intersection layouts. Is it possible to manually create a dynamic EOP profile based on the cross slope from the centerline profile?
Civil 3D 2012
Windows 7, 64 bit
View 1 Replies
View Related
Mar 8, 2013
In my profile view I have existing and proposed levels in m.
The level difference is also in m but I'd like it to be scaled to show mm, as this is quicker to read on site.
Is there some way to edit the equation and multiply by 1000?
View 6 Replies
View Related
May 31, 2012
If Inventor 2010 has the capability of showing certain parts/sub-assemblies in phantom style lines on the idw/dwg file?
I have a box unit, where I want to show the base, but with the posts meeting it in phantom. Then when I do the drawing for the posts, I want the base and roof in phantom. Then when I do the roof drawing, I want the posts in phantom again.
I can't change the BOM level as it will apply to every level of detail. when suppressed, they completely vanish. Is there a way to do it rather than find the parts in the browser (whilst in the drawing) and change the properties (over-riding them)?
View 9 Replies
View Related
Jan 19, 2013
I want to show only the lowest level of folders in my LR LIbrary module. Used to do that but somehow got changed. Now shows parent folder, 2nd and 3rd levels. If I uncheck INCLUDE SUBFOLDERS it just gives me a zero photo count for the parent but still shows the folder and I still ahve to click levels to get to the photos. If I right click on parent folder....someone said to click Promote Subfolders......I do ot have this choice!
View 2 Replies
View Related
Dec 5, 2006
Im using AutoCAD 2007.
I have done a land survey showing a top of bank - and the bottom of bank, which ive then contoured by using Carlson Survey (AutoCAD engined).
Im trying to draw cross sections through my model that would obviously show the level of the surface.
The bank lines and contour lines are polylines.
View 9 Replies
View Related
Dec 31, 2013
Why new rooms show up in lieu of existing rooms when"show previous and demo" are set for the phase filter? Every single other existing element including doors, walls, windows, etc. show in the "show previous and demo" phase filter with the exception of rooms.
View 5 Replies
View Related
Nov 18, 2013
I need cross section information of a creek for a Hydrology program (DRAINS in Australia) and need to extract this from a surface I have created in Civil 3D. I require the Chainage and Level for a profile which represents the creek cross section at several specific locations. The information is essentially the data bands in a Profile which I can create, however I cannot see how to obtain this information in a form I can use.
the format of the data can be copy and pasted into Excel from which I can directly import the information into the software.
View 2 Replies
View Related
Jul 3, 2013
I am trying to create a label for fire hydrants in plan view that shows the flange elevation. I want the elevation to be 0.4' above the adjacent road profile. I added a reference text component to my label style that shows the profile elevation. Where would I find the expression for the profile elevation reference text?
Civil 3D 2012 SP3 | Win 7 64-bit SP1
Xeon E5-1620 @ 3.60GHz, 16GB Ram | NVidia Quadro 600
View 2 Replies
View Related
Aug 27, 2012
I have a drawing with multiple profiles. We originally had an existing and finished ground surface in the drawing, but decided to use a data shortcut to the surfaces as the design kept changing. We deleted the old surfaces from the drawing, and created the data references, using the same surface names for the new referenced surfaces.
The ground lines show up in the profile, but I can't get it to show the linetype I need for the EG surface (dashed). It doesn't act like a typical profile line - it now shows a lot of PVI points, and plinegen settings have no effect.
View 1 Replies
View Related
Mar 10, 2013
If there is no level 3 in the project browser. How can you add a 3 level to the project.
View 2 Replies
View Related
Jun 18, 2012
i have some simple profiles and just want to show the pvi's in plan view on the alignment.
i made a reference label and it works great. now i am trying to figure out if there is a quick way to locate the pvi station on plan view other than doing something like create a point using sta. and offset as parameters hand typing in the info.
View 2 Replies