AutoCad 3D :: How To Check For Object Collision
Jul 26, 2013
I have some model boat plans (scanned images) and would like to convert them to 3D objects. I used a software img2cad for the conversion, and since the conversion is not perfect i have to redraw all the parts. So here are my questions:
1. For the parts i mostly used lines, splines and arc. What is the best way to join them, so later i can edit them to 3d solid object? I used join and it works well, however it creates a small angled edge at the end. (see image or zoom in dwg file).
2. For some of the parts the extrude command works only on the edges of the 2D object creating a hollow 3D object. How do i fill the inside?
3. In near future i would need to assemble all the parts and make the skeleton of the boat. Is there a way to check for object collision (if parts are too big for example to fit where they should)?
I also attached a file with two ribs of the boat as an example.
View 7 Replies
ADVERTISEMENT
Mar 23, 2011
I have two "banners" created from a plane with a cloth modifier on each. One banner is in front of the other. I want the one in front to drop first. After it drops and is waving around a little...setting down...I want the second banner to drop. Because they are close to each other and both waving a bit, they will hit each other.
How can I have both set to be a cloth object and both set to be collision objects to the other? I thought it was one or the other. (In the cloth object properties)
Max 2014 (SP2)
Win 7 64-bit; Dual Xeon E5-2687W @ 3.10 GHz; 64 GB Ram
NVIDIA GeForce GTX 570; Quadro 4000
View 8 Replies
View Related
Mar 30, 2012
how can I check whether an object has a reactor connected?
I wrote the following
(defun c:**** (/ ogg collegaReactor) (setq ogg (car (entsel))) (setq collegaReactor (vlr-object-reactor (list (vlax-ename->vla-object ogg)) "NOMEAPP" '( (:vlr-modified . testedit) (:vlr-objectClosed . endedit) ) ) ))(defun testedit (notifier-object reactor-object parameter-list / ogg collegaReactor) (alert "testedit"))(defun endedit (notifier-object reactor-object parameter-list / ogg collegaReactor) (alert "endedit"))
If I start two or three or more times the "c:****" and select the same object, when I changethe "alert" appear several times.
View 8 Replies
View Related
Feb 25, 2013
Without opening the drawing...
How can I iterate through and check the object type of all objects in model space? And... then delete them if they are certain types... like lines, circles, polylines, text, mtext, etc?
View 2 Replies
View Related
Oct 13, 2011
How do you mate two surfaces so that the item will not move any further once it makes contact with that surface? i.e a rotating cam which is designed to stop once it comes into contact with an object / surface.
View 2 Replies
View Related
Jan 9, 2014
Assemble several parts from Solidworks through step profile.Part2 and part3(attachments) no static interference ,when driving constraints (driver) immediately a collision report appears.Additional,when restrain the part 3(attachments)and drive constraint(driver) meanwhile open the collision detection ,finally,part2(attachments) goes through the barrier no checking collision.
View 9 Replies
View Related
Apr 18, 2013
Is there any way to do collision deform with massfx cloth like you could in reactor? Like in this tutorial: [URL].........
View 2 Replies
View Related
Jan 21, 2014
Quick question: I was able to make a model and her hair is poly. I'm not using the hair and fur plugin. I was able to make the hair flow by using the flex modifier but I want to add collision to it.
So when the model turns her head, tips of the hair will flow over the shoulder and not through it. I was messing around with the deflectors but I am not getting the results I want.
Rig: Intel Core Quad CPU Q6600 @ 2.40GHZ
8gb RAM
64bit OS
GeForce 660i GTX
3DS Max 2013
View 3 Replies
View Related
Jul 6, 2013
I have an image that is mostly alpha.Problem is that it blocks buttons from working.Is there any way to set a flag to an image so it is not part of the 'touch/mouse' collision funcitons?
i can arrange it behind the buttons... but that brings other issues, because something needs to be behind the image with alpha but over the buttons.
View 4 Replies
View Related
Jul 25, 2013
I want to have some kind of collision-detection within two symbols. So when one symbol collides with another there will appear be text like "squash" or something.
I haven't found anything about collision-detecting in edge animate, but I thought I could handle it with looking for the same css-parameters of both symbols. Obj1 is moving to Obj2 on a motion path. Now I want to have a Text, when it reaches Obj2.So I tried it like this:
var positionobj1 = sym.$("obj1").css("left");
var positionobj2 = sym.$("obj2").css("left");
if (positionobj1 == positionobj2){
sym.play("Text");
}
View 1 Replies
View Related
Jan 3, 2013
So i have 3 file DWG :
3.dwg : is a plan 'archi'
2.dwg is a plan with only décoration.
1. dwg is a plan with only the water.
i have this structure in my file (1.dwg) :
1.dwg
---> 2..dwg
---------> 3.dwg (this file is a Xref of 2.dwg)
--> is the blockRefecence (XRef).
Dim CollXref As New ObjectIdCollection Dim mydb As Database = Application.DocumentManager.MdiActiveDocument.Database Dim myTrans As Transaction = mydb.TransactionManager.StartTransaction ' Dim doc As Document = Application.DocumentManager.MdiActiveDocument
[Code] ......
So i don't want to add Id of a Xref From a Xref. (In my example i want only ObjectId of the 2.dwg not 3.dwg if i launch this code on 1.dwg.
View 3 Replies
View Related
Mar 8, 2012
I'm need to make a Map Check report on C3D2011, but I don't know how to do it. Since C3D everything have to be setup before it can be use, so my questions are: How do I setup map check? Or What do I need to do get map check report?
What are the steps to do it right?
View 3 Replies
View Related
Mar 15, 2012
I need to export data to an excel file but I need to check if the file is already open.
Searching the internet I found this but I don't know what "imports" to use to use to enable it.
Public Function FileInUse(ByVal sFile As String) As Boolean If System.IO.File.Exists(sFile) Then Try Dim F As Short = FreeFile() FileOpen(F, sFile, OpenMode.Binary, OpenAccess.ReadWrite, OpenShare.LockReadWrite) FileClose(F) Catch Return True End Try End If End Function
View 4 Replies
View Related
Dec 2, 2012
If any easy method to check the model in the inventor.now i doing each feature i have to check the fully constrained or not.if any easy method.
View 8 Replies
View Related
Oct 7, 2013
Im thinking of adding some kind of info that tells me if the active ipt or iam have an idw, by the same name. It should be available/visible when opening, or editing parts and assys.
View 3 Replies
View Related
Mar 21, 2013
I have a lack of expierence in using visibility checks. I created road profile , now i would like to check the visibility of it. Cuz my profile have hills , and the car driver must see other objects in the road . His sight in front should be 400 meters , eyes height 1 meter and the target in 400 distance should be seen by 1 meter tall.
View 1 Replies
View Related
Sep 7, 2011
I am working on a batch print application. I check the page info in current layout. I like to know if it's landscape or portrait? How I can do it in the code?
View 1 Replies
View Related
Oct 31, 2012
how to check the radius of a polyline arc?
View 6 Replies
View Related
Nov 22, 2008
When I try to check-in a feature to table that is stored on SQL Server I get this message: "'FdoSpatialGridTransform::CalculateParameters': The resolution is too large (> 0.1) for the extents."
View 4 Replies
View Related
Feb 20, 2007
I want to be able to see if any documents were printed from my computer last friday, but I'm not sure how to.
View 9 Replies
View Related
Apr 8, 2010
is there any way to check the entity selected by NonInteractivePickPoint? iwant to get the ownerid if the item selected is a 3d or 2d vertex. How is it written in vb.net?
View 3 Replies
View Related
Nov 2, 2011
The below VBScript code is from a property set definition in AutoCAD MEP...
The below works to return the effective name of a block that exists with a certain entity handle. How might I check if the blocks insertion point is at a particular coordinate by a fuz factor? ... and then if is not set then clear out the XData?
On Error Resume Next
Set AcadApp = GetObject(,"AutoCAD.Application")
AcadVerString = AcadApp.ActiveDocument.GetVariable("ACADVER")
Select Case AcadVerString
Case "18.1s (LMS Tech)"
aecBaseVer = "AecX.AecBaseApplication.6.5"
[Code] ...
View 1 Replies
View Related
Oct 11, 2011
Is it possible to find the type of a browsernode?
In my code I can only see that the type is a browsernode.
Should I use Browsernodedefinition to get the type?
Maybe it's not possible, so I can stop trying.
Dim oPane As BrowserPane = oDoc.BrowserPanes.ActivePane Dim tNode As BrowserNode = oPane.TopNode Dim oNode As BrowserNode Dim oNodes As BrowserNodesEnumerator = tNode.BrowserNodes For Each oNode In oNodes MessageBox.Show(oNode.Type) Next
Get control of your sheet metal files at [URL]
View 1 Replies
View Related
Oct 16, 2012
I'm looking for a way to programmatically check if a dll file is a AutoCAD plug-in, preferably getting the version too.The only thing I can think of is using
System.Reflection.Assembly.ReflectionOnlyLoad()
to load the dll, search thru its references looking for Acad-specific (acdbmgd etc.) get the reference version, compare it to a list....
View 9 Replies
View Related
Apr 25, 2012
is there any way to spell check your text in an .IDW file?
Also... How can I arrange my Dimensions so that our Dimension Standards are the standard Style?
View 6 Replies
View Related
May 29, 2013
I am having issues getting my .dwg files to check back in to Vault Basic. I can get all different types of files (.iam .ipt .idw) to check in without issues, but .dwg files hang and Inventor will eventually lock up.
I've tried disabling Visualization and I still cannot make it past this point. I can even tell it to check in everything at once, and it will breeze through the other files but any .dwgs will hang.
My PC Config:
Windows 7 Professional 64-bit
Intel(R) Core(TM) i7-2600 CPU @ 3.40GHz
16 GB RAM
Dual AMD Radeon HD 6450
Running Product Design Suite 2014
View 9 Replies
View Related
Dec 4, 2012
We use iproperties to describe our parts and have a 40 character limit. Is there any way ilogic could be used to check and possibly warn if an iprop field exceeds 40 characters?
Inventor 2010 Pro SP4, Vault Collaboration 2010
HP Z820 Xeon E5-2643 0 @ 3.3Ghz 16.0GB RAM
Nvidia Quadro 5000
View 5 Replies
View Related
Jul 29, 2013
I need to create a form with several options, corresponding to parts to load/unload. Only 1 checkbox can be activated at a time, so when I check a check box, the others have to be unchecked. In VB this should be radio buttons, is it possible to have the same issue in iLogic with checkboxes ?
View 3 Replies
View Related
Nov 8, 2005
The following code adds three user parameters to an .ipt:
Public Sub AddUserParams()
Dim oDoc As PartDocument
Set oDoc = ThisApplication.ActiveDocument
[Code].....
If I run this on a part that already contains any of these user parameter names I get an error. Is there a way to first check for each name and skip to the next if it already exists?
Also, how the heck do I set ExposedAsProperty for each of the parameters added?
View 5 Replies
View Related
Sep 25, 2013
I am running Inventor 2013 with vault 2013 on a brand new system. Everything was working great for a week or so, then inventor started to lock up during checkin. It would lock up with even a small simple part. I had the IT department try to remote in and change settings, with not luck. Then they "rebuilt" the system over again, this got things working for about another week and after that the problem started up again.
View 1 Replies
View Related
Feb 21, 2013
I am working with a fellow Inventor user who faces determining if a set of assemblies, on the file system, are complete and not missing any parts, references, etc. Aside from opening each one in Inventor direclty and manually verifying if the design is at least able to resolve al parts, is there any way to automate or semi-automate this check?
View 6 Replies
View Related