AutoCAD Civil 3D :: Slow Corridor Rebuilding After Adding Superelevation?

Oct 2, 2012

slow corridor rebuilding after adding superelevation?why?was ok previous years.

Civil 3D 2012
Work: Xeon W3503, 12GB, Quadro 2000, Dell P2211H x 2
Home: 3930k, 12GB, GTX 590, U3011, QX2710

View 9 Replies


ADVERTISEMENT

AutoCAD Civil 3D :: Event Viewer Error Message When Rebuilding Corridor?

Nov 6, 2013

I'm getting several messages saying "value on wrong side of alignment" when I rebuild my corridor.  I've checked the two target alignments that I'm using and they are on the correct side. 

Civil 3D 2014

View 2 Replies View Related

AutoCAD Civil 3D :: Corridor Surfaces And Superelevation

Feb 26, 2013

I have an alignement to which I have applied superelevation.

The superevation has been applied and the alignment has been annotation and it shows the change from camber to superelevation on  the curves.

However when I create a surface of my corridor it does not show the superelevation, the surface is showing a cambered alignment throughout.

I have created a new alignment, a new corridor and surface and still the same.

View 3 Replies View Related

AutoCAD Civil 3D :: Why Corridor Adding A Hinge

Sep 18, 2013

Why is my corridor adding a hinge?  [Atleast I think that is the problem]

I am trying to create a berm that is 8' wide.  For my assembly I used 4' wide basiclanes and daylightgeneral (with 3:1 slope in all parameters) on left and right side.

In the top image I have circled two of the areas in which the hinge line is shown.  And in the bottom right the cross section of one side of the berm is shown.  As you can see on the inside (left) there is two feet sloped at approximately -1% before it daylights to the surface at 3:1

Why isn't the left side matching the right?

View 4 Replies View Related

AutoCAD Civil 3D :: Labels Are Not Rebuilding

Jun 4, 2013

I opened a project that i had not been into for a month and for some reason the surface and labels will not rebuild automatically anymore.  Surface is set to rebuild automatic and i've gone in and changed the regenauto from on to off to on again, also rebooted the computer with no luck.  I have a combination of feature lines and points.  If I edit the elevations along the feature line the contours do not rebuild and the label does not change either.  If I hover over the elevation node in the feature line it will show the new elevation but the elevation label for that point does not reflect the change, neither do the contours.  If it is a point and I change it with the panorama window, the elevation tag will change but the contours do not rebuild until I tell it to rebuild.  Any slope labels going to that point do not update with it though.

View 2 Replies View Related

AutoCAD Civil 3D :: Adding Corridor Surface To EG Surface

Mar 6, 2012

I am trying to visualize a road project. The problems is, whenever the corridor surface goes below the EG surface (when the road is in cut) the EG surface is the only visible surface.

I sort of need to subtract the corridor surface from the EG surface, or merge the both surfaces into one.

View 3 Replies View Related

AutoCAD Civil 3D :: Surface Corridor Is Not Triangulating Entire Corridor Boundary

Sep 14, 2012

I have created a surface from a corridor.  I set the boundary of the surface to the daylight of the corridor.  In some areas of the corridor the surface does not triangulate see attached.

View 2 Replies View Related

AutoCAD Civil 3D :: Copy Corridor Or Corridor Station Values Only?

Dec 13, 2012

Copy a corridor successfully? I'd like to try this just a little worried about the explosion of evil this may cause to my Civil 3D session.

Even all the properties of the corridor setup from one to another would be useful. I'm building one corridor and an 2nd one that matches everything except I need to replace my Assembly with one meant for stripping.

View 9 Replies View Related

AutoCAD Civil 3D :: Corridor Surface Is Not Matching Corridor Top Links

Mar 21, 2013

My corridor surface is not matching my corridor top links.  see attachments.  this is affecting my volumes!

The section-plan(surface red).png is showing the section editor and the plan view.  the red highlighted line in section is the corridor surface and as you can see in plan view the surface is incorrect and wiggly.

The pdf is all my sections with the red linework being the corridor surface.

C3D ver 2012
Win 7, 64bit

View 2 Replies View Related

AutoCAD Civil 3D :: SuperElevation Not Responding?

Apr 13, 2012

I have a problem with my superelevation. everything is calculated accordingly but when i build my surface from corridor after i have calculated superelevation it does not show the results. Even my cross sections view still show a normal assembly cross section. It happaned on both C3d2011 and ad C3d3013. 

View 9 Replies View Related

AutoCAD Civil 3D :: Superelevation Information From Alignment

Oct 20, 2011

Is there a way to retrieve superelevation values from Alignment properties to show on, for example curve tables?.  I would like to display the super information along with curve geometry information.

View 1 Replies View Related

AutoCAD Civil 3D :: Subassembly Composer Superelevation

Jul 23, 2013

How to use the superelevation. I read that I have to enter this command:

if((Side=Left)AND(SE.HasLeftLO), SE.LeftLO,
if((Side=Right)AND(SE.HasRightLO), SE.RightLO,
CType(slope,Double)))

but I don't know where, and I just want to create a simple assembly with a slope and delta X and having a lane outside superelevation for the both side.

View 2 Replies View Related

AutoCAD Civil 3D :: Superelevation Curve Name API 2014

Sep 16, 2013

This is my aplicattion in Civil 3D 2014. URL....It´s a tool palette that checks the design criteria (for alignments,superelevations and profiles) according to Spanish rules.My program changes the name of each superelevation curve,for example:

---> With superelevation tool own of Civil 3D (Cuve.1,Curve.2,Curve.3)

---> With my program: (VisorNET Curva.1,VisorNET Cuva.2,.....)

 If I calcule again Superelevations using Superelevation button (Calculate/Edit superelevation)of Civil 3D, Civil 3D doesn´t change the Superelevation Curve Names and appears again (VisorNET Curva.1,VisorNET Curva.2,...).Superelevation CurveName property doesn´t exist in settings:

URL....and there isn't a name template. I would like to have this property (read and write----get and set) of settings.Then, I could re-write  the default Superelevation CurveName format. (name template)

View 4 Replies View Related

AutoCAD Civil 3D :: Offset Alignment With Superelevation

Aug 6, 2013

Is there a way to set the superelevation data to offsets alignments in Civil 3d 2014.

View 2 Replies View Related

AutoCAD Civil 3D :: Subassembly Composer Superelevation

Feb 13, 2013

I am working with SAC , and cant understand how that superelevation works, how to make my models work in CIvil 3d in superelevations... how to build it properly in SAC.  I would rly love to get .pkt file with working model as example  , or at least get some usefull tip.

View 9 Replies View Related

AutoCAD Civil 3D :: Created An Alignment With Superelevation Wizard

Mar 20, 2013

I am currently trying to design a roadway with a reverse curve in it. I am having trouble getting my corridor to model my assembly correctly as it is showing the roadway as the generic assembly and is not adding the superelevation that is shown on my alignment. I have done the following:

1) created an alignment with superelevation wizard - superelevation diagram shows up correctly

2) Created a profile for this alignment

2) created an assembly (Road layer is LaneSuperelevationAOR) in which the right lane is set to use SE on the right outside lane and the left lane is set to use SE on the left outside lane

3) Created a corridor with the assembly and set the width targets to the offset alignments (I.e. the lines that are the edge of pavement) 

The corridor does not show the superelevation values based off of the alignments superelevation that it has calculated. I did get the supers to show when i tied the Future EOP to the existing surface, however i do not want it to tie in, I want it to just show the values that were calculated. 

Is there a way to get this to show without referencing an additional profile? Also, on my first curve i want to keep the right side at a -2% slope and raise the left side to 2% slope (RC). Is there a way to limit the calcuations to only use a reverse curve?

View 3 Replies View Related

AutoCAD Civil 3D :: Superelevation View With Station Equation

Jun 13, 2012

The superelevation view seems to ignore any station equations applied to an alignment.

Windows 7 Pro x64
Civil 3D 2014 HF1
Dell Precision T1650
i7 3770
NVIDIA Quadro 2000
SSD Boot
16 GB Ram

View 1 Replies View Related

AutoCAD Civil 3D :: Superelevation Data In Plan View

Jul 12, 2007

I found super elevation labeling for profile, but not for alignment in plan view. Is there a way to label alignment, f.x. in critical points of super elevation automatically?

View 2 Replies View Related

AutoCAD Civil 3D :: Overriding Superelevation Using Outside Lane Elevation Method

Oct 23, 2013

In my corridor I have used superelevation.  In a horizontal curve which has a cross slope of 4.5%, I have an intersection.  To allow for a smoother ride through a few lanes in the intersection I want to change the cross slope from 4.5% to 1%.  I was planning on doing this by using a Outside Lane Elevation Method of a Profile.  However, it appears that my super has precedence over my profile.  Is there are way to make this work?

View 2 Replies View Related

AutoCAD Civil 3D :: Losing Superelevation Data When Editing An Alignment

Oct 29, 2013

I have an alignment I need to edit that has a reverse curve.  The first curve was made with the "Floating Curve (from entity, radius, through point)"  and the second with "Free Curve Fillet (between two entities, radius)"

When I delete one or both curves i lose all the superelevation data beyond the editing location due to the temporary spit in the alignment.  The superelevation data is all manual.  This is a trail and the super is based on drainage not curves.

how to edit the alignment with a temporary split and not lose the superelevation data?  I have not found a way yet to remove the reverse curves and not have a temporary gap.

View 3 Replies View Related

AutoCAD Civil 3D :: Alignment Superelevation Labels In Plan View

Dec 30, 2013

Is there a way of adding superelvation data such as full superelevation cross slope to an alignment curve label in plan view?

In my case we add a label for each horizontal curve with critical curve data such as PI Station, Delta, Degree of Curve, etc... but I can't seem to find a way of adding any superelvation information to the plan view as a label.  Ideally I would like to be able to add the maximum cross slope value and superelevation critical stations to the label.

There is a way of adding the superelevation critical stations a labels to the alignment similar to how PC's or PT's  are labeled, but it does not give the cross slope value.

View 1 Replies View Related

AutoCAD Civil 3D :: Design Surface Wavy At Transition And From Superelevation

Jun 27, 2012

my surface is way through the in and out transition of my superelevation. the waves are dependent on frequency (ie if i change from 1m to 5m the waves get longer.

View 4 Replies View Related

AutoCAD Civil 3D :: Superelevation For 1-Lane Ramp (different Shoulder Widths)

Apr 3, 2013

 I'm attempting to use the Superelevation tool on an interchange.  I have 4, 1-lane ramps that I need to apply superelevation to.  The three issues I have (so far) are:

In the Calculate Superelvation Wizard...

1. In Roadway Type, I don't know what to choose, I'm leading toward Undivided Crowned (center Baseline ) because my assembly (as of right now) is set up as an undivided crowned roadway (with the crown on the west travel lane edge). Which Roadway Type I should choose (for a 1-lane Ramp with different shoulder widths?)

2.  Moving on to the the Lanes category doesn't matters.  I uncheck symmetric Roadway, hoping I can choose "0" for the number of lanes on the Left, or at least put the lane width down to "0" but can't do either.  I uncheck the Symmetric Roadway and it still makes everything symmetric (it acts as though it is still checked?) I only want to show a single 15' lane.  (I even tried to use undivided planar, and put both lanes at 7.5'each, but then I still have shoulder issues...)

3.  Move to the Shoulder Control.  Why doesn't it give me the option to do different shoulder widths?  On ramps it is very common (at least in Wisconsin) to have an 8ft shoulder on the right and a 4ft shoulder on the left.  How can I type in 2 different shoulder widths.

View 2 Replies View Related

AutoCAD Civil 3D :: Property Item From Superelevation CriticalStationCollection Doesn't Exist

Sep 14, 2013

In the documentation API 2014: for SuperelevationCriticalStationCollection appears the property "Item":

[URL]

but I´m trying to use it and it doesn´t exist.
 
public static void Breaksegment(Autodesk.AutoCAD.DatabaseServices.ObjectId identificador) { try { Document doc = Application.DocumentManager.MdiActiveDocument; Database db = doc.Database; Editor ed = doc.Editor; using (DocumentLock docLock = doc.LockDocument()) { using (Transaction trans = db.TransactionManager.StartTransaction()) { Alignment align = trans.GetObject(identificador, OpenMode.ForWrite) as Alignment; SuperelevationCriticalStationCollection criteriaStationColl = align.SuperelevationCriticalStations; criteriaStationColl.Item trans.Commit(); } } } catch (System.Exception ex) { System.Windows.Forms.MessageBox.Show(ex.Message); } }

I have added the Reference:Assembly: AeccDbMgd (in AeccDbMgd.dll) and I ´m using Autodesk.Civil.DatabaseServices
 
Autocad Civil 3D 2014 +SP1
Quad Core Intel i7 3770-cpu 3.40Ghz.
ssd samsung 840 pro 512gb+ssd samsung 840 pro 256 gb+1tb hdd
32gb RAM 1600 Mhz.
nVidia Quadro 2000.
Win 7 Pro 64bit

View 3 Replies View Related

AutoCAD Civil 3D :: Adjust Superelevation / Cross Slope Transition On Intersection

Dec 19, 2013

In attached file the normal cross slope of secondary road(AB)  is 2% Right to left (Right higher). and for primary road cross slope is 2% Left to Right (Left higher). I produced this junction using intersection wizard and cross slope of secondary road only starts changing from start of curb return to match the long slope of primary road. Is this possible to increase this transition lentgh on secondary road to create smooth contours.

View 3 Replies View Related

AutoCAD Civil 3D :: Shoulder Subassembly That Varies Slope In Relation To Lane Superelevation Slope

Jan 22, 2013

i need a shoulder subassembly that varies slope in relation to the lane superelevation slope. i know that i can get a subassembly for the shoulder that will follow the alignment superelevation xml data but in my case i can't use it because we are just adding a shoulder to an existing road. we're not changing the superelevation of the existing road, just milling and overlaying and widening. right now i've created a profile of the outside edge of the shoulder that gives me the correct shoulder slope but whenever i change my centerline profile i have to redo the shoulder profiles which is a real time suck.

View 9 Replies View Related

AutoCad :: Rebuilding Viewbase Views?

Apr 26, 2013

Rebuilding viewbase views? I have a drawing with unresolved views and I'm not sure how it happened.

On a semi-related note.. Does viewbase based sheet layouts make Autocad more unstable?

View 9 Replies View Related

Paint.NET :: Does Adding Plugins Slow Down Performance

Mar 18, 2012

when i first used plugins my paint.Net slowed down and become less responsive. is it because of the plugins or would it just be my computer?

View 3 Replies View Related

AutoCAD Map 3D :: Rebuilding Access Database But Retaining Links?

Oct 1, 2013

My company has an access database that has all of our service data on it. I am currently considering rebuilding the database because it is a database with one table and a million fields. I want to split the database up into separate tables with relationships. All of these tables would be linked based on the same key field Service_ID.

Now here is the hard part. The data would be in a one to many relationship with one record for service info and multiple records per service for pipe info. The data is currently linked to objects in AutoCAD Map 3d 2014 based on the Service_ID key field and a "service" link template.

If i rebuild this database, am I going to lose all of my links? or will i retain the links? Also, is there a way to automatically generate links based on the service_ID field? For instance there are 3 records of pipe information for 1 service. Previously all of these records would be in the same table, but now the tables are split. Since they have the same Service_ID as the Service information, will the links show up?

View 9 Replies View Related

AutoCAD Inventor :: Subassembly Constraints Constantly Need Rebuilding

Jun 5, 2012

I'm working in a large top level assembly and the following is happening

1. Assembly is happy with no broken constraints
2. Edit a constraint (in this case, to rotate a part based on an angular constraint with another part)
3. Error message pops up telling me dozens of constraints in subassemblies are broken
4. Click Accept, assembly does not visually update
5. Click "Rebuild All" button under manage tab
6. 3 minutes later the model is updated, everything is happy, model looks how it should.

This type of problem has been happening lots to different assemblies with difference constraint scenarios.

View 5 Replies View Related

AutoCAD Civil 3D :: Gap In Corridor

Jun 13, 2013

C3D 2014

when I created a Top surface, C3D showed me otherwise. I need a gap at an intersection. In the attached DWG the intersection corridor has been removed from view by isolate.

I used 2 seperate baselines to force the road corridor to have a gap at the intersection.

Looked OK .. except ..later .. when I created a Top surface, only the first baseline is used to create the surface, the second baseline is skipped   : (

I obviously did not make a gap correctly. What is the correct way? Or.. is there no way .. must the designer create multiple seperate corridors when the road has gaps? 

View 3 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved