AutoCAD Civil 3D :: Overriding Superelevation Using Outside Lane Elevation Method
Oct 23, 2013
In my corridor I have used superelevation. In a horizontal curve which has a cross slope of 4.5%, I have an intersection. To allow for a smoother ride through a few lanes in the intersection I want to change the cross slope from 4.5% to 1%. I was planning on doing this by using a Outside Lane Elevation Method of a Profile. However, it appears that my super has precedence over my profile. Is there are way to make this work?
View 2 Replies
ADVERTISEMENT
Apr 3, 2013
I'm attempting to use the Superelevation tool on an interchange. I have 4, 1-lane ramps that I need to apply superelevation to. The three issues I have (so far) are:
In the Calculate Superelvation Wizard...
1. In Roadway Type, I don't know what to choose, I'm leading toward Undivided Crowned (center Baseline ) because my assembly (as of right now) is set up as an undivided crowned roadway (with the crown on the west travel lane edge). Which Roadway Type I should choose (for a 1-lane Ramp with different shoulder widths?)
2. Moving on to the the Lanes category doesn't matters. I uncheck symmetric Roadway, hoping I can choose "0" for the number of lanes on the Left, or at least put the lane width down to "0" but can't do either. I uncheck the Symmetric Roadway and it still makes everything symmetric (it acts as though it is still checked?) I only want to show a single 15' lane. (I even tried to use undivided planar, and put both lanes at 7.5'each, but then I still have shoulder issues...)
3. Move to the Shoulder Control. Why doesn't it give me the option to do different shoulder widths? On ramps it is very common (at least in Wisconsin) to have an 8ft shoulder on the right and a 4ft shoulder on the left. How can I type in 2 different shoulder widths.
View 2 Replies
View Related
Jan 22, 2013
i need a shoulder subassembly that varies slope in relation to the lane superelevation slope. i know that i can get a subassembly for the shoulder that will follow the alignment superelevation xml data but in my case i can't use it because we are just adding a shoulder to an existing road. we're not changing the superelevation of the existing road, just milling and overlaying and widening. right now i've created a profile of the outside edge of the shoulder that gives me the correct shoulder slope but whenever i change my centerline profile i have to redo the shoulder profiles which is a real time suck.
View 9 Replies
View Related
May 26, 2012
Superelevation curve criteria specifies axis of rotation but the assembly does not contain pivots.
okay i got this Before , just when i wanted to change in the Super Elevation Wizard , to outside lane rotation , i recently used AOR type , but yet no luck. also in my profile the super elevation the Cross slop Band : i always no matter what a rotation about center line.
View 1 Replies
View Related
Apr 13, 2012
I have a problem with my superelevation. everything is calculated accordingly but when i build my surface from corridor after i have calculated superelevation it does not show the results. Even my cross sections view still show a normal assembly cross section. It happaned on both C3d2011 and ad C3d3013.
View 9 Replies
View Related
Apr 22, 2012
I'm attempting to create a profile view and then modify the label by overriding the text components. Unfortunately the profile view bands don't populate the labels until after my command is complete making it not possible to modify them in one command. Is there a way to update the band to have it show the labels?
Civil 3D 2013
View 3 Replies
View Related
Oct 20, 2011
Is there a way to retrieve superelevation values from Alignment properties to show on, for example curve tables?. I would like to display the super information along with curve geometry information.
View 1 Replies
View Related
Jul 23, 2013
How to use the superelevation. I read that I have to enter this command:
if((Side=Left)AND(SE.HasLeftLO), SE.LeftLO,
if((Side=Right)AND(SE.HasRightLO), SE.RightLO,
CType(slope,Double)))
but I don't know where, and I just want to create a simple assembly with a slope and delta X and having a lane outside superelevation for the both side.
View 2 Replies
View Related
Feb 26, 2013
I have an alignement to which I have applied superelevation.
The superevation has been applied and the alignment has been annotation and it shows the change from camber to superelevation on the curves.
However when I create a surface of my corridor it does not show the superelevation, the surface is showing a cambered alignment throughout.
I have created a new alignment, a new corridor and surface and still the same.
View 3 Replies
View Related
Sep 16, 2013
This is my aplicattion in Civil 3D 2014. URL....It´s a tool palette that checks the design criteria (for alignments,superelevations and profiles) according to Spanish rules.My program changes the name of each superelevation curve,for example:
---> With superelevation tool own of Civil 3D (Cuve.1,Curve.2,Curve.3)
---> With my program: (VisorNET Curva.1,VisorNET Cuva.2,.....)
If I calcule again Superelevations using Superelevation button (Calculate/Edit superelevation)of Civil 3D, Civil 3D doesn´t change the Superelevation Curve Names and appears again (VisorNET Curva.1,VisorNET Curva.2,...).Superelevation CurveName property doesn´t exist in settings:
URL....and there isn't a name template. I would like to have this property (read and write----get and set) of settings.Then, I could re-write the default Superelevation CurveName format. (name template)
View 4 Replies
View Related
Aug 6, 2013
Is there a way to set the superelevation data to offsets alignments in Civil 3d 2014.
View 2 Replies
View Related
Feb 13, 2013
I am working with SAC , and cant understand how that superelevation works, how to make my models work in CIvil 3d in superelevations... how to build it properly in SAC. I would rly love to get .pkt file with working model as example , or at least get some usefull tip.
View 9 Replies
View Related
May 3, 2012
I've used the OverlayWidenMatchSlope1 subassembly to widen a new travel lane using the existing carriageway crossfall then I try to create another lane using the same assemble following the same slope but the insert point always starts on the existing ground rather the new levels from the first new widening lane.
View 3 Replies
View Related
Jul 11, 2013
I am trying to create an elevation label that will give me the spot elevation followed by the letters "TC" and then on the line below subtract 4 inches from the elevation followed by the letters "BC". It's easy enogh to add the letters but the simple equation of elevation - 4 inches eludes me.
View 3 Replies
View Related
Dec 19, 2012
When I snap a point to an object, the point takes on the elevation of the object. I would rather the point's elevation stay as is.
-changing osnapz variable
-latest civil 3d service pack
A few weeks ago I did not have this problem but once my computer was switched to the company's global server and c3d was reinstalled the problem appeared. Furthermore (post switchover), when a colleage of mine prepared a simple test drawing with just a line and a point, he was able to snap to that line without the point changing elevation. When he sent that drawing to me and I tried snapping the point to the object, the same problem occured with the point taking the elevation of the line object. I suspect it is a system variable issue
View 7 Replies
View Related
Apr 16, 2012
i have some existing drainage pipe and structures in a base plan that i need to change the invert (which is the easy part) and the top elevation to the existing top elevation that does not meet the minimum presect in civil 3d 2012 is there a way to change these min. to match my exisitng elevation for example i have a catch basin invert is 15.45 top is 17.56 with a 18" rcp the cover will be less than 12" and i need to change this.
View 3 Replies
View Related
Mar 20, 2013
I am currently trying to design a roadway with a reverse curve in it. I am having trouble getting my corridor to model my assembly correctly as it is showing the roadway as the generic assembly and is not adding the superelevation that is shown on my alignment. I have done the following:
1) created an alignment with superelevation wizard - superelevation diagram shows up correctly
2) Created a profile for this alignment
2) created an assembly (Road layer is LaneSuperelevationAOR) in which the right lane is set to use SE on the right outside lane and the left lane is set to use SE on the left outside lane
3) Created a corridor with the assembly and set the width targets to the offset alignments (I.e. the lines that are the edge of pavement)
The corridor does not show the superelevation values based off of the alignments superelevation that it has calculated. I did get the supers to show when i tied the Future EOP to the existing surface, however i do not want it to tie in, I want it to just show the values that were calculated.
Is there a way to get this to show without referencing an additional profile? Also, on my first curve i want to keep the right side at a -2% slope and raise the left side to 2% slope (RC). Is there a way to limit the calcuations to only use a reverse curve?
View 3 Replies
View Related
Jun 13, 2012
The superelevation view seems to ignore any station equations applied to an alignment.
Windows 7 Pro x64
Civil 3D 2014 HF1
Dell Precision T1650
i7 3770
NVIDIA Quadro 2000
SSD Boot
16 GB Ram
View 1 Replies
View Related
Jul 12, 2007
I found super elevation labeling for profile, but not for alignment in plan view. Is there a way to label alignment, f.x. in critical points of super elevation automatically?
View 2 Replies
View Related
Feb 22, 2012
I tried to import the Lane Toward Crown subassembly to my Lanes tab, but the import function looks for *.pkt files and all I have in the Stock Subassemblies folder are *.vb files.
How can I get the *.pkt files?
View 2 Replies
View Related
Apr 18, 2012
Im using civil 3d UKIE 64bit, having a serious problem with adding a lane widening to an offset alignment. It is a straight alignment approx 200m length, but when i enter the parameters that is asked, at the end it says no solution!
View 2 Replies
View Related
Oct 2, 2012
slow corridor rebuilding after adding superelevation?why?was ok previous years.
Civil 3D 2012
Work: Xeon W3503, 12GB, Quadro 2000, Dell P2211H x 2
Home: 3930k, 12GB, GTX 590, U3011, QX2710
View 9 Replies
View Related
Oct 29, 2013
I have an alignment I need to edit that has a reverse curve. The first curve was made with the "Floating Curve (from entity, radius, through point)" and the second with "Free Curve Fillet (between two entities, radius)"
When I delete one or both curves i lose all the superelevation data beyond the editing location due to the temporary spit in the alignment. The superelevation data is all manual. This is a trail and the super is based on drainage not curves.
how to edit the alignment with a temporary split and not lose the superelevation data? I have not found a way yet to remove the reverse curves and not have a temporary gap.
View 3 Replies
View Related
Dec 30, 2013
Is there a way of adding superelvation data such as full superelevation cross slope to an alignment curve label in plan view?
In my case we add a label for each horizontal curve with critical curve data such as PI Station, Delta, Degree of Curve, etc... but I can't seem to find a way of adding any superelvation information to the plan view as a label. Ideally I would like to be able to add the maximum cross slope value and superelevation critical stations to the label.
There is a way of adding the superelevation critical stations a labels to the alignment similar to how PC's or PT's are labeled, but it does not give the cross slope value.
View 1 Replies
View Related
Jun 27, 2012
my surface is way through the in and out transition of my superelevation. the waves are dependent on frequency (ie if i change from 1m to 5m the waves get longer.
View 4 Replies
View Related
Nov 19, 2013
I create Curb Return Fillet assembly with shoulder in SAC , but now i have problem with targeting , when i giving two targets it takes only first target and ignores second, could you check attached assembly and drawing ?
View 4 Replies
View Related
Aug 1, 2012
I have an "ultimate" profile that has be set for a proposed roadway the first 1500' of the roadway will be constructed at this final profile while the last 900' will be constructed for an interim design not at the full depth pavement. So my typical for the final is 9.25 inch of pavement over 14" of stone and the interim is 4" over the same 14" of stone when we transition from the 4" to the 9.25" we are using a 20:1 taper the question is how to model this taper condition and have you had any success.
View 1 Replies
View Related
Nov 18, 2011
I need a sub assembly for a lane that you can specify varying cross fall. i.e it starts at -2.5% and ends at +2.5%.
View 3 Replies
View Related
Apr 7, 2005
I watched the cul-de-sac placewhere and I seem to missing some functionality shown. Specifically the ability to link a transition lane to an alignment and profile via corridor properties>logical name>no width shown as the placewhere shows?
View 8 Replies
View Related
Sep 14, 2013
In the documentation API 2014: for SuperelevationCriticalStationCollection appears the property "Item":
[URL]
but I´m trying to use it and it doesn´t exist.
public static void Breaksegment(Autodesk.AutoCAD.DatabaseServices.ObjectId identificador) { try { Document doc = Application.DocumentManager.MdiActiveDocument; Database db = doc.Database; Editor ed = doc.Editor; using (DocumentLock docLock = doc.LockDocument()) { using (Transaction trans = db.TransactionManager.StartTransaction()) { Alignment align = trans.GetObject(identificador, OpenMode.ForWrite) as Alignment; SuperelevationCriticalStationCollection criteriaStationColl = align.SuperelevationCriticalStations; criteriaStationColl.Item trans.Commit(); } } } catch (System.Exception ex) { System.Windows.Forms.MessageBox.Show(ex.Message); } }
I have added the Reference:Assembly: AeccDbMgd (in AeccDbMgd.dll) and I ´m using Autodesk.Civil.DatabaseServices
Autocad Civil 3D 2014 +SP1
Quad Core Intel i7 3770-cpu 3.40Ghz.
ssd samsung 840 pro 512gb+ssd samsung 840 pro 256 gb+1tb hdd
32gb RAM 1600 Mhz.
nVidia Quadro 2000.
Win 7 Pro 64bit
View 3 Replies
View Related
Dec 19, 2013
In attached file the normal cross slope of secondary road(AB) is 2% Right to left (Right higher). and for primary road cross slope is 2% Left to Right (Left higher). I produced this junction using intersection wizard and cross slope of secondary road only starts changing from start of curb return to match the long slope of primary road. Is this possible to increase this transition lentgh on secondary road to create smooth contours.
View 3 Replies
View Related