AutoCAD Civil 3D :: Labeling Deflection Angles On Sanitary Sewer Alignment At Manhole

Jul 15, 2013

Setting up my styles for Sanitary Sewer and most counties require a Deflection Angle for your sewer mains.

Any formula to use to show Rt or Lt deflection pipe angles in the Sanitary Sewer plan view Structure Lable Style or how to create one?

Have not found anything that works, the Structure rotation Angle doesn't work at all like that.

View 4 Replies


ADVERTISEMENT

AutoCAD Civil 3D :: Deflection Angles Labeling In Alignments In Band Set Or Profile View

Jun 23, 2012

How to show the deflection anglesof alignments. I want to show those angles in band set or profile view.

AutoCAD Civil 3D 2012 SP 2

View 9 Replies View Related

AutoCAD Civil 3D :: Get Alignment Deflection Angles Into A Table

Apr 2, 2013

If there was any way to get deflection angles of an alignment into a table?  I finally figured out how to get C3D to label them using the add note label.  If this is not possible, is there a way to make a table of the notes? I am using C3D 2013 version if it makes any difference.

View 4 Replies View Related

AutoCAD Civil 3D :: Adding Sanitary Sewer Flows To Nodes From Spreadsheet

Dec 12, 2012

I have a master plan development that I am trying to model different wastewater flows scenerios for I am basically following this paper from  AU 2011 [URL] but have a couple of issues I am trying to work around.

Basically I want to take a spreadsheet of flows determined for specific nodes and upload it into SSA quickly from the paper
I can see that you can write a shp file of the network and then add different flow scenerios to the .dbf file and them use the GIS import function of SSA to get the flows assigned in one hit.

The issue I have however is that my network is a prelimary design in Civil3d as pipes and structures and if I create a .sdf of the network and then.shps from that data I do not get the structure sump elevations, this is not something that created in the shp file export process,

To work around this I through maybe I could export the network from Cicil3d to SAA which gies me all the strucutres with the correct sump levels and then also create a .shp and .dbf file and add the flows and them do a GIS import of just the structures and merge them with the exisiting network as the structure names as exactly the same and therefore the gis import should find the correct structures.

However SSA does not and adds a second lot of nodes with the same structure name but with Junction in the front.

View 1 Replies View Related

AutoCAD Civil 3D :: Storm And Sanitary Sewer Analysis Stopped Working

Aug 30, 2011

I tried to open the Storm and Sanitary Sewer analysis program and got an error message.  The error message asked me to send a report but the report was rejected. 

View 8 Replies View Related

AutoCAD Civil 3D :: How To Specify Deflection Angle While Plotting Horizontal Alignment

Aug 2, 2013

How to specify the deflection angle while plotting the horizontal alignment? I’m wondering if there is a way to provide the deflection angle while plotting the horizontal alignment (based on the tangent-tangent with curve method).

Software: AutoCAD 2014, AutoCAD C3D, AutoCAD M3D, RevitWindows 7 (Ultimate 64 bits),Firefox 20.0,Kaspersky 2013.

View 2 Replies View Related

AutoCAD Civil 3D :: Alignment Label Style To Show Deflection Angle

Oct 10, 2008

Alignment, Geometry Point, Label Style that shows the "deflection angle" as either right or left at the PI point of an alignment.

View 9 Replies View Related

AutoCAD Civil 3D :: How Deflection Angle Can Be Shown In Horizontal Alignment Curve

Jul 31, 2013

How the deflection angle can be shown in the horizontal alignment curve? I’m wondering if there is a way to automatically show the deflection angle of the horizontal alignment curve (attached)? 

View 3 Replies View Related

AutoCAD Civil 3D :: Manhole Label Inv References Adjacent Null Instead Of Next Manhole

Jul 24, 2013

I have a sanitary run manhole to manhole with null structures in between for lats.  Each null is named "wye(lot#)" which I really do not need labeled anywhere but grants me the illusion of order and control.  When I label the manhole (style uses text for each component) it references the inverts as from adjacent structure the nearest of which is the null.  I need it to reference the upstream manhole as the from structure. BMP?

Another issue is the text for each component.  There are times when I need to have the manhole label show "INV 8" IN 209.50 Int Drop (MH110)" or "INV 8" IN 208.75 w/ Slide (MH 108)".  But as you know if I add to one I add to all.  I found a post that discussed editing the xml to do this but my code either looked different than the example or I was looking at it cross eyed.  I think if I could add an invert type column to the structure properties pipes tab the text for each component could add it to the label.Is there a better way people have been handling this?

View 3 Replies View Related

AutoCAD Civil 3D :: Labeling Deflections On Alignment

Feb 9, 2012

I read through the previous posts but still I am not able to do this. I am using C3D 2012.

What I need to do is label Deflection angles of an alignment (delta angle). The alignment does not have any curve. 

So basically it will be some kind of PI or geometry point label showing the deflection angle. 

Labelling LT or RT would be great but at this time I dont need that. 

I hope it explains. 

View 9 Replies View Related

AutoCAD Civil 3D :: Labeling Alignment Intersections In Production Sheets?

Sep 5, 2012

Using the Best Practices, different components in their own DWG files, all brought together in a production sheet where I can place the labeling for that sheet. I can add labels for Surfaces, Alignments, Pipe networks, through the Xref(s). Evidently this was not extended to Intersection Objects.

What I'm doing now is creating a new Intersection at each street intersection just so I can get a label which shows the station of each alignment at the intersection. Is there a better way to do this?

View 3 Replies View Related

AutoCAD Civil 3D :: Turn Off Display Of PI Symbols For Small Angles Along Alignment

Feb 8, 2013

I have an alignment for a proposed steel gas pipeline that is several thousand feet long.  The alignment is stationed and set to display PI symbols (triangle) at each change of direction.  However, steel pipe is relatively flexible so small changes in direction (a few degrees) are irrelevant and I do not want the PI symbols to display in those areas.  Is there a setting (a tolerance so-to-speak) in Civil 3D to edit when PI symbols are displayed for an alignment.  For example, I want to set it such that PI symbols are not displayed unless the alignment changes direction by more than 10 degrees at a given PI.

View 9 Replies View Related

AutoCAD Civil 3D :: Labeling Inlets In Street Profiles To Reflect Street Alignment Stationing?

Sep 28, 2012

I've created a network of my stormsewer (which means the stormsewer lines are all on different streets) and added the inlets to my street profiles. 

How do I get the profile structure labels to reflect the stationing from the street alignments?

View 2 Replies View Related

AutoCAD Civil 3D :: Edit In Storm And Sanitary Analysis-Drawing Underlay Is Missing?

Oct 12, 2011

In Civil3d 2012 when the Edit in Storm and Sanitary Analysis command is used to send a Civil3d pipe network and Catchment areas to SSA the program appears to open as expected with the "Create New Project" dialogue box displayed.

When the Create New Project prompt is accepted nothing is displayed in the SSA plan view.

But.... If I go to the SSA File pulldown menu the .spf project file is available and when it is selected a dialogue box is displayed indicating that the Background file(the dwg) file cannot be found and do we want to search for it "Yes/No".If No is selected the pipe network is displayed as expected.

If Yes is selected and the dwg file located and selected then the pipe network is displayed as expected but the background file looks like proxy objects.

Civil3d2012
Win7 64bit
NVidia Quadro2000M

View 9 Replies View Related

AutoCAD Civil 3D :: How To Design Sewer Line

Apr 19, 2013

Looking for a reference or example how to design a sewer line in civil 3d.

View 6 Replies View Related

AutoCAD Civil 3D :: Manhole Rim Elevation From Surface

Aug 16, 2013

I have a question about pipeline networks.

I have a civil3d pipe network that has modeled by my co-worker before.

Now I want to put that pipe network on new surface and get rim elevation from surface automatically and also after stretch it can update rim elv based on that surface.

View 3 Replies View Related

AutoCAD Civil 3D :: Hydraflow Sewer Extensions

Jan 17, 2013

I opened Hydraflow Sewer Extensions and created a project. I was able to save it and open repeatedly without problems. I opened open project dialogue window here I copied and renamed a copy of the project file. When I tried to open either the original file or the renamed version - Hydraglow shuts down. The project file has attached dxf file as abackground. (see attached). I hate to lose a day of data entering given my tight deadlines.

View 3 Replies View Related

AutoCAD Civil 3D :: Manhole Profile Labels Disappear

Dec 4, 2013

I have my design drawing referenced into another drawing for plan and profile sheets.  I made some changes to my pipe network in my design drawing, and my manhole profile labels disappeared in my sheet drawing!

The manhole labels in plan view stayed where they were, and updated with the changes I made.  The profile labels just disappeared.  

View 2 Replies View Related

AutoCAD Civil 3D :: Bolted Manhole Rims And Closed Tank?

Dec 27, 2012

I had a chance to use the old StormNet software extensively in my previous company. This is my first time that I'm using it under AutoDesk. It appears to work similarly. So now I'm trying to model a small but a bit of a complex system.

I have a modeling scenario where I have a storage tank with two orifices. The first orifice outlets to a 10 inch diameter pipe which eventually outfalls into a stormwater treatment area. This area will allow ponding. Due to site topography a portion of this pipe run will be pressurized with the outlet set just low enough below the 1st orifice elevation at the tank. The second orifice outlets to a 12 inch diameter pipe which connects to the underground storm drain system via gravity. This second pipe run will only take on water that exceeds the capacity of the first. With this scenario I have  a few questions:

1. In trying to model the bolted rims to make the portion of the system to work as a pressurized system, my understanding is that I have to set the surcharge elevation (at the junction) high enough above the max rim elevation. I have set up the surcharge elevation high enough, trying different elevations and the max water elevation in all cases is exceeding the max rim elevation.

2. My storage tank is a close tank. Is there a way to ensure that is modeled as such or does the program assume is a storage node such as a detention pond?

View 3 Replies View Related

AutoCAD Civil 3D :: How To Divert Storm Sewer Flows For Treatment

Jan 3, 2013

I need to model a diversion manhole in a storm sewer system.  The diversion will take X cfs from the system and send it to a water quality treatment facility.  After leaving the WQ facility, it will be returned to the storm sewer system at the next manhole downstream.

I tried in Hydraflow but it doesn't look like diversions are possible.  Thought about modeling up to the diversion manhole and taking that data into some other program, and then coming back into a second Hydraflow model that handles the downstream bit.

View 2 Replies View Related

AutoCAD Civil 3D :: Manhole Labels In 2013 UKIE Template

Apr 18, 2013

problem labelling manholes when using the 2013 ukie template? - pipe labels show up but nothing else. 

If I open the label style composer it looks fine in preview, visibility is set to true and its on the same layer as the pipe labels so should display OK.  It seems to be a template setting though because if I open the metric or imperial templates and draw a network the labels all work. if I can find the right tick box it would be quicker than labelling with mtext.

View 2 Replies View Related

AutoCAD Civil 3D :: Single Line Manhole And Pipes In Profile View

May 31, 2007

I remember seeing an article or web cast on how to create a style to display a single line for a manhole. It may have been about using the parts create tool. But for the life of me, I can’t remember where I saw it.

Also I had created a style in C3D2007 to display the pipes in profile as a single line. This was done by drawing the flow arrow in a non printable colour over the top of the pipe.In C3D2008 this is no longer possible. So now what?

View 5 Replies View Related

AutoCAD Civil 3D :: Adjust Elevation Of 6-inch Sewer Pipe In Profile

Oct 11, 2013

I think that our file has been corrupted. We tried to adjust the elevation of a 6-inch sewer pipe in the profile and then the display of the pipe went up to a 12-inch, even though the pipe properties still show it as a 6. All the other pipe sizes seem to be working, though we did have a similar problem with 4-inch pipe the day before and fixed it with an audit. Audit does not fix this problem. It seems to apply to all six inch pipes.

The file was created in Civil 3D 2007. We are now using C3D 2012 with SP1. My machine is 64-bit but the other person working in the file has 32-bit.

I have attached the file and the pipe in question is in the sewer network and is named SP B 11.

Is there any hope for this file? Of course this is right as we are trying to meet a deadline.

PS I tried to add the file but was size restricted, then I trimmed the file down to under 1.5 MB and was still size restricted.

View 3 Replies View Related

AutoCAD Civil 3D :: Deflection Angle Label For Structures

Nov 12, 2010

Is there a way to show the deflection angle between incoming and outgoing pipes in a structure label? Or any label at all, for that matter? I know it can be done with alignments at the PI point, but only in the source drawing.

View 1 Replies View Related

AutoCAD Civil 3D :: Structure Plan View Label Goes To Edge Of Manhole Instead Of Center

Feb 10, 2013

I have a label style creating a callout bubble for structures in a pipe network, but it keeps placing the label (and therefore, the leader when dragged) at the edge of the structure, and I want it to go to the center.

View 2 Replies View Related

AutoCAD Civil 3D :: Pressure Pipe Deflection In Profile View

Feb 7, 2013

I created a pressure pipe with no bends since my alignment is fairly straight. However, I'm changing the elevations on the pipe using a combincation of the profile view snaps and elevation edits in the properties and it doesn't restrict my deflection to my deflection settings not does it add any bends.

Is this still a missing function in Pressure Networks? Or is there something I'm missing?

View 1 Replies View Related

AutoCAD Civil 3D :: Option To Include Deflection Angle To Next PI In A Table

Dec 17, 2012

I have created an alignment and I would like to create a table that includes this information: station, northing, easting, bearing, deflection angle, deflection left or right, and length. So far I have not found any option to include the deflection angle to the next PI in a table.

View 4 Replies View Related

AutoCAD Civil 3D :: How To Remove Deflection In Pressure Pipe In Profile View

Dec 9, 2013

I clicked on a pressure pipe in profile view and selected "Edit Pressure Network in Profile...". The panel that came up has a button that says "Follow Surface". I did that and selected all of my pipe and entered 4 feet below surface for my water main and it put alot of deflections in my pressure pipes. How to remove the deflections?

View 2 Replies View Related

AutoCAD Civil 3D :: Changing Alignment Direction Where Feature Line And Alignment Coincide?

May 28, 2012

i've made a serpantine curve that starts from one line of alignment and end on the other line.

i wanted to know how can c change alignment direction when these two feature line and alignment meet each other in order to change the alignment path?

View 3 Replies View Related

AutoCAD Civil 3D :: Data Reference Alignment Stationing Differs From Original Alignment

May 3, 2012

I using a data reference/shortcut to properly label an alignment in paperspace. However when I reference the alignment in and apply the labels the aren't the same as the original alignment that I am referencing. Is there a setting where I am supposed to apply a new beginning station.

Also it seems as though the stationing(distance) isn't even matching up 1:1 with the original drawing. For example in the original base drawing my alignment starts at 10+00 with the next PI at 14+76.98, but the stationing on the reference alignment starts at 0+83.33 with the very same PI being labeled as 1+23.08. So the very same distance is 476.98' in the real design and the drawing it's being referenced in, but the stationing of the referenced alignment shows it as 39.75 Units.

I've attached a screen of the beginning of the alignment.

Civil 3D 2012
Windows 7 Service Pack 1
Intel Core i7-2600 CPU
16GB RAM

View 5 Replies View Related

AutoCAD Civil 3D :: Change Alignment Label Style Set After Alignment Has Been Created?

Jul 18, 2013

Using Civil 3d2012, Is it possible to change the alignment label style set after the alignment has been created?  For example, for an alignment that was created with alignment label set X - change the label set to alignment label set Y?  It seems like this should be pretty easy, I must be missing something obvious. 

View 2 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved