I have a sanitary run manhole to manhole with null structures in between for lats.  Each null is named "wye(lot#)" which I really do not need labeled anywhere but grants me the illusion of order and control.  When I label the manhole (style uses text for each component) it references the inverts as from adjacent structure the nearest of which is the null.  I need it to reference the upstream manhole as the from structure. BMP?

Another issue is the text for each component.  There are times when I need to have the manhole label show "INV 8" IN 209.50 Int Drop (MH110)" or "INV 8" IN 208.75 w/ Slide (MH 108)".  But as you know if I add to one I add to all.  I found a post that discussed editing the xml to do this but my code either looked different than the example or I was looking at it cross eyed.  I think if I could add an invert type column to the structure properties pipes tab the text for each component could add it to the label.Is there a better way people have been handling this?

View 3 Replies


ADVERTISEMENT

AutoCAD Civil 3D :: Structure Plan View Label Goes To Edge Of Manhole Instead Of Center

Feb 10, 2013

I have a label style creating a callout bubble for structures in a pipe network, but it keeps placing the label (and therefore, the leader when dragged) at the edge of the structure, and I want it to go to the center.

View 2 Replies View Related

AutoCAD Civil 3D :: Manhole Rim Elevation From Surface

Aug 16, 2013

I have a question about pipeline networks.

I have a civil3d pipe network that has modeled by my co-worker before.

Now I want to put that pipe network on new surface and get rim elevation from surface automatically and also after stretch it can update rim elv based on that surface.

View 3 Replies View Related

AutoCAD Civil 3D :: Manhole Profile Labels Disappear

Dec 4, 2013

I have my design drawing referenced into another drawing for plan and profile sheets.  I made some changes to my pipe network in my design drawing, and my manhole profile labels disappeared in my sheet drawing!

The manhole labels in plan view stayed where they were, and updated with the changes I made.  The profile labels just disappeared.  

View 2 Replies View Related

AutoCAD Civil 3D :: Bolted Manhole Rims And Closed Tank?

Dec 27, 2012

I had a chance to use the old StormNet software extensively in my previous company. This is my first time that I'm using it under AutoDesk. It appears to work similarly. So now I'm trying to model a small but a bit of a complex system.

I have a modeling scenario where I have a storage tank with two orifices. The first orifice outlets to a 10 inch diameter pipe which eventually outfalls into a stormwater treatment area. This area will allow ponding. Due to site topography a portion of this pipe run will be pressurized with the outlet set just low enough below the 1st orifice elevation at the tank. The second orifice outlets to a 12 inch diameter pipe which connects to the underground storm drain system via gravity. This second pipe run will only take on water that exceeds the capacity of the first. With this scenario I have  a few questions:

1. In trying to model the bolted rims to make the portion of the system to work as a pressurized system, my understanding is that I have to set the surcharge elevation (at the junction) high enough above the max rim elevation. I have set up the surcharge elevation high enough, trying different elevations and the max water elevation in all cases is exceeding the max rim elevation.

2. My storage tank is a close tank. Is there a way to ensure that is modeled as such or does the program assume is a storage node such as a detention pond?

View 3 Replies View Related

AutoCAD Civil 3D :: Manhole Labels In 2013 UKIE Template

Apr 18, 2013

problem labelling manholes when using the 2013 ukie template? - pipe labels show up but nothing else. 

If I open the label style composer it looks fine in preview, visibility is set to true and its on the same layer as the pipe labels so should display OK.  It seems to be a template setting though because if I open the metric or imperial templates and draw a network the labels all work. if I can find the right tick box it would be quicker than labelling with mtext.

View 2 Replies View Related

AutoCAD Civil 3D :: Single Line Manhole And Pipes In Profile View

May 31, 2007

I remember seeing an article or web cast on how to create a style to display a single line for a manhole. It may have been about using the parts create tool. But for the life of me, I can’t remember where I saw it.

Also I had created a style in C3D2007 to display the pipes in profile as a single line. This was done by drawing the flow arrow in a non printable colour over the top of the pipe.In C3D2008 this is no longer possible. So now what?

View 5 Replies View Related

AutoCAD Civil 3D :: Labeling Deflection Angles On Sanitary Sewer Alignment At Manhole

Jul 15, 2013

Setting up my styles for Sanitary Sewer and most counties require a Deflection Angle for your sewer mains.

Any formula to use to show Rt or Lt deflection pipe angles in the Sanitary Sewer plan view Structure Lable Style or how to create one?

Have not found anything that works, the Structure rotation Angle doesn't work at all like that.

View 4 Replies View Related

AutoCAD Civil 3D :: Edit Pipe Network - How To Trim Pipe That Pass Through Manhole

Sep 25, 2012

I created pipe network for my storm drain project. I have located all the structures (manhole) to all angle point of my alignment as required. Also I "insert" manhole every 400' per local code requirements using the command "network layout tools; structures only. My problem is I couldn't find the tools how to trim the pipe that pass through the manhole. Please see attached pdf file.

View 1 Replies View Related

AutoCAD Civil 3D :: Structures Import As Null

Jun 25, 2013

I have set the migration defaults to my part list and the pipes come in as expected but all the structures come in as null? I even went as far as setting every option to my rect junction NF and they still come in as null?

View 2 Replies View Related

AutoCAD Civil 3D :: Null Structure Description

Apr 18, 2011

We use a lot of Null Structures but then give them different descriptions.  More often than not when I give them a description and then get out of the drawing, the next time I get back in it says "Null Structure" again.   How can I keep the description the way I want it?

I know that "the right way" would be to have specific structures made for each of these items, but that doesn't seem to be a priority at my company..

View 9 Replies View Related

AutoCAD Civil 3D :: Maximum Angle Between Adjacent TIN Lines

Sep 12, 2012

I am trying out this option, and am noticing that whenever I close and reopen the drawing with a surface that uses this option, it resets my maximum angle from whatever I have it set to, to 90 degrees. Am I missing some setting that defaults the max angle to 90 degrees on drawing open? Or is something else going on here?

View 8 Replies View Related

AutoCAD Civil 3D :: Storm Sewers Migrating Null Structures?

Jun 25, 2013

I have set the migration defaults to my part list and the pipes come in as expected but all the structures come in as null? I even went as far as setting every option to my rect junction NF and they still come in as null? What did I miss?

Civil 3D 2012 & 2013
HP Z210 Workstation
Intel Xeon CPU E31240 @ 3.30 Hz
12 GB Ram
64 Bit Win7 OS

View 5 Replies View Related

AutoCAD Civil 3D :: Points Automatically Placed Adjacent And Perpendicular To An Alignment?

Aug 20, 2013

I need to place points automatically and in order sequentially along an alignment and I need to generate data from the points relative to an adjacent alignment. SO, two alignments, adjacent but not parrallel to each other. The data would then be point #, sta and offset from the adjacent alignment with the points placed in order and by window or crossing. I have a few thousand to place so one at a time would be an undesireable solution of course.

View 1 Replies View Related

AutoCAD Civil 3D :: 2014 Null Structure Labels In Profile Drop To Zero

Aug 20, 2013

Some of our structure styles for null structures are set to display as a block in profile.  When we label these null structures in profile, the label dimension line extends to down to zero, way off the profile view.   When I change the style to display the boundary of the null, the label pops back into place, but when I change the style back to a block, it will drop back to zero.  I just upgraded to 2014 and this did not occur in 2010-2013.  I've upgraded a drawing with existing profiles and also created a new pipe network and the results are the same.  What changed in 2014 that would cause this?

View 4 Replies View Related

AutoCAD Civil 3D :: Does Adjacent Elevations By Reference Work Only With Parallel Features

Aug 29, 2013

I have two feature lines. They are not parallel.

The tool "Adjacent elevations by reference" seems to work fine only when feature lines are well parallel one to another ? 

Also, it seems that C3D method works fine if  "parent" object  and "object to edit " have similar number of vertex, similiar "lenght",.... 

View 1 Replies View Related

AutoCAD Civil 3D :: Merge Two Or More Adjacent / Overlapping Surfaces Into Single Surface?

Jun 5, 2012

Is it possible to merge two or more adjascent / overlapping surfaces into a single surface?Is it possible to "Delete" multiple surfaces in one go?

View 2 Replies View Related

AutoCAD Civil 3D :: Point Label Size Change When Label Is Moved?

May 8, 2012

The label associated to a grading point when is moved when is moved changes its size automatically and a leader appears. After this happen no control over the grading point and its associate label. refer to the image below.

View 1 Replies View Related

AutoCAD Civil 3D :: Changing Profile Line Label Style Causes Label String To Revert To Default

Sep 6, 2012

C3D 2013. We have profile line labels, some of which get manually edited (for example, change the "<[Tangent grade(FP|P2|RN|AP|GC|UN|SD|OF)]>" to a static number such as 0.29%).

However, if you CTRL+Click and select one of these labels and change the style of that one label, then the manual edits are lost and the label reverts back to the default string.

Is there any way to turn this behavior off?

View 1 Replies View Related

AutoCAD Civil 3D :: Edit Label Text In Parcel Label

Jan 3, 2013

Is there a way to "Edit Label Text" in a Parcel area label? Similar to the way you can edit it in other styles.

View 9 Replies View Related

AutoCAD Civil 3D :: Label Profile Label Stations As Raw

Aug 8, 2013

I'm trying to label my Profile label stations as raw stations, 20~20 meters, and I'm not being able to adapt the format to STATION 0, STATION 2, without any plus zeros or +, or -, or commas, or anything, as following in the image.

Is there a easy way to do it?

View 2 Replies View Related

AutoCAD Civil 3D :: References Not Updating

Aug 15, 2013

I have a recurring problem that I can't seem to figure out.  I have my existing grade TIN surface as a data shortcut into my roadway design file, but it sometimes will not update when opening the drawing.  The surface profile will not display until the surface is manually synced.  Any labels that are associated with that surface (or other object) will just display the ??? because it can't seem to connect to the data.  After a manual sync it seems to come back.

View 9 Replies View Related

AutoCAD Civil 3D :: Sorting Data References

Dec 3, 2012

How do you sort data references?

[URL].....

Civil 3D 2012 (64)
Windows 7 Pro (64) SP1, 16 GB
AMD Radeon HD 6900

View 8 Replies View Related

AutoCAD Civil 3D :: Broken Data References?

Jul 8, 2013

Possible to open a drawing that was created with AutoCad Civil3D 2011 and create all of your Civil objects and data references if it is a bad idea to then open it at a later date in AutoCad Civil as Autocad 2011. Does this effect any of the data in the drawing. It has been recommended here that we do this for making minor line/text edits as some folks have slower computers that cant handle the civil side of the program.

why we are constantly facing corrupt drawing files that lose references.

View 4 Replies View Related

AutoCAD Civil 3D :: Crashing Due To Data References

Jul 8, 2013

A co-worked has made a mention of "Reference Alignments not found in Reference Drawing" error message popping up multiple times this morning and said he thinks it is a trendd in many drawings that have been worked on. In my experience this message pops up if you move the location of the reference drawing, or change the name of the alignment without synchronizing.

The issue is it has been said that this is fatal erroring the drawings.

I have not worked on the project myself and am just relaying what i heard-

I know this is a very vague question, we have 2011 Civil 3d

View 1 Replies View Related

AutoCAD Civil 3D :: Searching For Textstyle References In Styles?

Jun 18, 2012

C3D 2013.Is there a way to search the C3D styles for references to textstyles?

IOW - I know there are references to a certain textstyle in this drawing, how to find it/them without manually inspecting each style?

View 8 Replies View Related

AutoCAD Civil 3D :: Creating Multiple Data References?

Feb 9, 2013

Is it possible to create more than one data reference at a time?

I have approximately 30 alignments with over 100 profiles in my profile design drawing. The interface to create the data shortcuts allows me to do so by selecting multiple alignments and profiles. This works well and is efficient. To create the data references I have to create the reference for each alignment and profile one at time. I estimate this will take at least 30 minutes.

I am using Civil 3D 2012.
Civil 3D 2012 SP3 | Win 7 64-bit SP1
Xeon E5-1620 @ 3.60GHz, 16GB Ram | NVidia Quadro 600

View 1 Replies View Related

AutoCAD Civil 3D :: Xref Has Multiple References - Not Detached

Apr 8, 2013

I know the difference between attach and overlay for reference files. 

The problem here is that the xref IS attacehd as an overlay and I am still not able to detach it.

I am working on WisDOT transportation plans.  For those that are not familiar with these projects, certain reference files must plot black in some plan sections, but grey in others.  When we submit the plans to the utility companies, all utilities must be black. but are grey in everyother submittal.  I changed the xref level attributes to plot black with the intensions of detaching the xref and reattaching to revert back to the orignial grey level attributes.  Is there anyway that changing the level attributes is somehow not letting the xref be detached?

Intel Core i5-2500K CPU @ 3.30 GHz
8.00 GB
64-bit

View 1 Replies View Related

AutoCAD Civil 3D :: Labeling Profiles From Data References

Nov 17, 2013

We recently started using Civil3d 2013. We made a huge jump from LDD 2008. We have profiles designed and data short cuts are created. We have existing and proposed. 

Now i've created a reference and brought them into another drawing. First I tried to set up the color and linetype for each profile. When I do this. Both the existing and proposed become the same color and linetype.I do not see how to select the existing from the proposed and set the color and linetype.

Next I select the proposed profile and right click and select Edit Labels. I start to create the PVI labels. When I do this the PVI's for the existing profile get labeled. I want the proposed profile labeled. Not the existing.

View 3 Replies View Related

AutoCAD Civil 3D :: All Autodesk Files And References Were Removed?

Aug 21, 2012

After using Autodesk recommendations for a clean install, remove programs, remove files and remove registry edits I can not delete the file

C:Program FIlesCommon FIlesAutodesk Sharedacsigncore16.dll

How this file is still in use if all Autodesk files and references were removed?

View 4 Replies View Related

AutoCAD Civil 3D :: Data References Cause Program To Freeze

Apr 5, 2012

We just discovered data at our office, and I am pretty stoked about them 90% of the time. We do have one problem with them though. We are doing a small road, with 10 or so alignments and a few pipe networks of 40 pipes and structures. 1 surface, and that is about it. I made a cross sections sheet with our design file xrefed and data references to everything in it. Now it won't open. I can copy it to my local hard drive, run a recover, and then open it, save it back, add in all the data references and redo labels, but I can't open it from there.

Is there some way to have it open without syncing?

View 5 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved