Revit :: Put URL Link To A File In Components Instance Parameter
Jan 27, 2012
I am trying to put a URL link to a file in a components instance parameter, to show up in the properties palette, I can put the URL in there, but no link is established. How would I get this to link to the file?
View 1 Replies
ADVERTISEMENT
Feb 4, 2013
I have been making and sharing shared parameter files for years... For some reason today a co-worker's shared parameter file is invalid or could not be read...
We have run a couple of tests - I can create one on my computer and send to her without any issues... Any that she creates and sends to me - is invalid... WHY?
View 8 Replies
View Related
Feb 28, 2012
Starting brand new project. Would like to change the name of some shared parameters within my txt file. As far as I know you cant chnage the name once its established witin Revit (unless theres a third party app). Would there be any issue withi this? Utimately I am pushing these parameters into new geometry and I would like them to better conform to a standard for a particular customer. I rennamed JUST the parameter name and it seemed to work ok.
View 2 Replies
View Related
Apr 26, 2013
Why masking region and filled region not working (bicome)transparent when I attach link file. If I hide the link file ,maskin region and filled region works fine. Visual style is hidden line.
View 4 Replies
View Related
Mar 6, 2013
I'm having trouble with the Revit ribbon not giving me the normal commands. For example, I'm trying to place a water closet family and the modify ribbon is giving me "Import Instance" instead of placement options (as in placing on a face) like it did just a couple days ago. I was placing these water closets in this same model just a few days ago and it was working fine. I've imported a few DWG files since then and now I'm getting this behavior. how do I undo it?
View 3 Replies
View Related
Oct 21, 2012
Sometimes when I drag a new symbol instance to my artboard and resize it, the instance looses it alignement with the pixel grid.
This happens despite the fact that...
I checked the box for pixel grid alignement when I created the documentthe symbol option is set for align to pixel gridthe original shape in the symbol is aligned to pixel grindthe original shape has the align to pixel grid check box in the transform panel checked
So why when I resize the symbol instance does it break the pixel grid alignmnet and result in a blurred 1px stroke?
View 1 Replies
View Related
Jan 19, 2012
Is there a way to display the HW Group within the door tag? I'm working on a new door tag for our office, and they have requested that HW Group #s be displayed, so the door installer knows which hardware group to install.
I find type parameters (width, Mark, Manufacturer, Etc) but no Instance parameters (HW Group, door materials, etc)
Would I need to make a shared parameter for this?
I can schedule HW Groups, so shouldn't I be able to tag them as well?
View 4 Replies
View Related
Dec 13, 2013
I have just really started looking at better ways to create and use dynamic blocks. Is it possible to link one parameter with another and have it adjust that parameter accordingly?
A specific example I would like is that if a block is rotated beyond a certain amount them the text would rotate 180 degrees. So it needs to be like ' IF A=[0,180] THEN B=180, how to implement that though.
I have been playing with look up tables but that doesn't seem to do it. I can't get my head around block property tables yet so maybe that's the key.
View 0 Replies
View Related
Jan 22, 2014
I have made a Family that is based off the Metric Structural Framing - Beams and Braces template. When I import my Family into a project and create a instance of the Family (which is a channel) the channel doesn't extend the whole distance of the geometric line. Its always 1500mm long (thats the default length in the .rfa file). See below image for my problem:
I made my extrusion inside the Left Elevation view and not inside a Floor Plan view; simply because it is easier to create the complex geometry of it. Maybe this has affected its inability to stretch to the length of the line? How can I edit my family so that the extrusion will stretch the whole length of the line/beam?
View 1 Replies
View Related
Jun 13, 2011
I have an elevation drawing of a door that I am going to make parametric so it will update if I change things like top rail width, or stile width.
Along with the door elevation, I also have section drawings of that door. The sections are not parametric, just standard blocks and polylines.
Now, what I'm wanting to know is can I somehow link a value from the parametric block to the value of a dimension on the section drawings so that if I were to stretch the top rail in the section from 4 5/8" to 5", the top rail on the elevation would change with it?
View 1 Replies
View Related
Aug 14, 2011
Is it possible to link a parameter value to a function? I want text or attributes to never be "upside down".
If it is rotated with a rotation parameter the text would need to be automatically flipped or rotated if the angle is less than say >3*PI / 4 and < 7*PI/8.
View 9 Replies
View Related
Sep 12, 2012
I've got a block with 2 lines of text, the second line being optional. If the second line is omitted, the first line should be moved down, so it's centered.
I can handle the second line being omitted with a visibility parameter. And I can handle the first line being moved down with a move parameter. But how can I link the two?
Ideally, I'd be able to re-use the line 1 attribute and display it in whichever place was correct, but that doesn't seem to be possible.
View 9 Replies
View Related
Apr 21, 2012
I've just moved back to windows and have an odd thing I don't remember happening before. Every time I open an additional file, a new photoshop icon shows up on the Taskbar (windows 7). The way I remember it working previously, there was only one icon on the task bar regardless of how many files are open.
View 2 Replies
View Related
Mar 7, 2012
I would like to insert a cooktop that I have as a component family. I see in the architect tab, window, door, etc. but no component.
View 1 Replies
View Related
Nov 30, 2013
I'm having trouble inserting a bath in particular from the components tab. I go to components and I only have 3 items in the drop down list; termination board, construction trailer and metal support. How can I add a bath to the components list? The bath doesn’t work for all those families. I’ve added a bath to my project browser screen and dragged it in from there but I would like it to be in the components drop down lists. How do I do this? I’m using revit 2013. may be a very simple solution but it has had me stuck for some time
View 1 Replies
View Related
Feb 17, 2014
Is it possible to make the graphic represention of a component in a schedule (make a legend component representation a parameter) or use legends dynamically. I would like to schedule all the casework with quantities of each component. But the current schedule has a graphic representation next to the quantities but it is not in revit and the quanties are determined manually by counting them. I know there is a add on you can purchase to create dynamic legends but is there a way to do this directly in Revit?
View 1 Replies
View Related
Jan 17, 2012
Is there any way to tag a legend component? I'm trying to draw a "door types" drawing which shows the elevation of each type of door and I want to be able to place a title under each door that displays the door type mark. This is a very standard type of drawing that architects draw for almost every project and..after all...what could be more basic to a legend component then to be able to label it?
Now I use text to label each type of door...but if someone changes the door type mark and fails to update the legend also....I get a very un-Revit-like mis-coordination with my door schedule!
View 2 Replies
View Related
Apr 24, 2012
Whenever I attempt to open a non-native format file from outside of Inventor it launches a fresh instance of IV. Currently I've been working around it by dragging the file to the status bar of IV, but at least a few times a week I forget and double click it.
Some scouring of the web and these boards yielded some info concerning this problem as it pertains to native formats, but I haven't been able to find anything for neutral formats. I'm sure it requires a registry key tweaking, but I'm not comfortable enough with regedit to go in there and just start changing stuff without some level of guidance. The problem occurs whether the files are opened from windows or an internet browser (tried firefox and ie). I suspect that every format I ever wanted to open would require a separate edit, in that case I'd be perfectly happy with just a fix for .step files. That would at least have me set for 90% of my downloads and offer an improvement to my overall sanity level.
View 7 Replies
View Related
Jan 26, 2012
I am making a detail library for the company. When I make my own detail components my element keynote doesn't staywith the component even though I have done new entries to the keynote text and updating everything with the new path gone into the materials and assigned the keynote and the main library file uses the new path to the keynotes. Yet everytime I bring in something new that I have created. I have to resassign the keynote. But if I bring in one of revits detail components, the keynote is right there.
View 1 Replies
View Related
Jun 13, 2012
Is it possible to do so? If not, how can I break the file apart so that I can work on the 2d detailing within the Revit file while the other guy is working on the other part of the file.
View 1 Replies
View Related
Apr 17, 2013
How do I prevent the components beyond the non-transparent walls and roof from showing through. I have double and triple checked the the transparency setting for the walls and roof in 'Override Graphics in View' and they are both set at '0'. Note these specifics:
Walls: Only the window glass shows through.Concrete Roof: Everything shows through as if transparency is set at 50%.
View 2 Replies
View Related
Nov 14, 2012
I have a floor joist/subfloor/finish floor system where the joists are hung from the sill inside the foundation wall, this means that the joists stop at the wall but the subfloor will continue over the sill plate and the finish floor will stop at the inside edge of the bottom wall plate. As near as I can figure, in order to get this to show correctly in section I really need to create the complete floor assembly by stacking 3 separate floor sub-assemblies (framing, sub-floor, finish floor) is this correct? (this is the method I'm currently using) Is there a way to manipulate the sub-components in section that I haven't found?
View 2 Replies
View Related
Sep 11, 2013
I want to export from Revit 2013 to AutoCAD so that each component of a wall assembly exports to a separate AutoCAD layer. For example on a simple stud wall with drywall on both sides I would like the interior lines on different layers than the lines for the outside faces. Is this possible?
View 2 Replies
View Related
Mar 7, 2014
Is it possible by importing a drafting view or copying 2D details, to not duplicate the detail components families ? I tried many ways, but I always get my families duplicated.
Copying 'Gypsum' will always duplicate with 'Gypsum1', even if they are exacly the same original family.
View 2 Replies
View Related
Sep 17, 2012
I'm getting an error message that I don’t fully understand when using an adaptive component. "There is only one component in this repeater" I am trying to create a undulating ceiling and attach an adaptive "Rafter" to follow the form. I can occasionally get it to work but on occasion I receive the error message. I can send you the file if you like, I’m pretty sure it’s a “User Issue”!RAC 2013
I have been told that it is to do with the direction that I draw the curves but I would like a more indepth explanation of this error...
The other issue I'm having may have to do with the placement of the adaptive component on the node plane, depending on where I place the component it will change the orientation if the rafter...
View 2 Replies
View Related
Oct 20, 2011
I am trying to create an Island family with cabinet components nested into the island family. I have included both a 3D view of what I want the island to look like and a floor plan of what I have right now. I want to be able to adjust the size of each of these cabinets with a parameter. But I am not sure how to get them to stay lined up like they are right now.
If I change the size to a larger size the center cabinet overlaps the cabinet on the right. but if I add another reference plane to the right side of the center cabinet, when I try to adjust the size I get an error message saying "Constraints are not satisfied".
View 8 Replies
View Related
Aug 10, 2011
I am having difficulty placing components in my Revit Architecture 2012 model. They are wall hosted (outlets) & floor hosted (floor boxes) components. I have taken the MEP, Base Building, Interiors, and Structural models and linked them into my new file. I have linked them in as overlay. Should I have changed the reference type to attachment?
When I go to place my components I recieve the following notifications from Revit and am unable to click any walls or floors: "Click on Wall to place Instance" (outlets) "Click on Floor to place Instance" (floor boxes). How do I set up these linked files so I can place my families?
View 2 Replies
View Related
Apr 29, 2013
I've created a family that represents a poke-through with nested, shared families for different components. Everything visible in plan is made with Symbolic lines instead of Generic Annotations. The reasons being too numerous to explain here.
The problem I'm running into is that the family looks fine when the View Discipline is set to Architectural but when set to Electrical (1/8" scale in both) part of the shared components begin to get masked. I cannot figure out why they are behaving this way, except that some of the lines are creating some sort of masking area in the Electrical discipline. When the nested families are not shared the component looks fine in both disciplines. I've attached images and the family for you to try.
View 1 Replies
View Related
Nov 4, 2013
The Cut Plane in a Plan View doesn't really represent the cut component but instead some kind of projection.In my case, I use a lot of Face Based Windows and Doors since my walls are often slanted. The Plan View representation of these components doesn't look right. A workaround is placing these components in a Component/Model in Place environment.
View 3 Replies
View Related
Mar 22, 2013
I have been working on creating windows for the place I work. I want to make my windows so they are quick and easy to create new ones without having to add in new information like if the glass is tempered or if its an egress window. I would like to set up formulas for these. I am stuck at my egress window parameter. I have included an image of what I am working on and the calculations and formulas I have so far. I would like to have my egress check box to say yes if the Opening Width is greater then 20", the opening height is greater then 24" and the opening sf is greater then 5.7 Sf. How would I set this parameter up?
View 3 Replies
View Related
Oct 20, 2013
I've created an area schedule that divides my plan into seperate appartments. I would like to sort mu window schedule by this parameter- is there an option to link a window to a specific area, just like it's linked to floors?
View 1 Replies