Revit :: Notes In Mirror Linked Model
Aug 17, 2013How to keep notes not change position in mirror linked model?
View 1 RepliesHow to keep notes not change position in mirror linked model?
View 1 RepliesI have a problem. The linked model from our electrical engineer its lights are at the correct height but the ACT ceiling is still running its lines throiugh the lights. how do we take care of this to where the linked model which has the lights in it cut through our ACT ceiling from our central model?
View 2 Replies View RelatedI have a Revit model (A) being linked into another Revit Model (B). In model B I set the VG of the linked model A to By Linked View. Now, when I do this I see all my Element Keynotes, but non of my User Keynotes show.
Things tested:
Created models C and D to try in fresh environment - All Keynotes show up
Created model E and linked A into it - User Keynotes do not show up
Overwrote the Keynote Family in A and retested - User Keynotes do not show up
So this means there is some problem in Model A that it is not pushing the User Keynotes through when linked.
I have created a big and complex Revit model, in Revit 2013. It's now time for me to print the sheets - I want them in PDF and DWF. But I really have some problems doing that. When I print to PDF it takes about 20 minutes for it to print 1 drawing - and it will not be complete - elements are missing compared to the original view. Often Revit stops working - and it's the same story when I try to save a DWF.
I think the reason why I have the problem is because of the complexity of the building's geometry. Have modeled it by importing SAT. files from Rhino - to create the form. The result is great but the file is now 370 Mb. I'm trying to link the model in to a new Revit project to minimize the file, and hopefully get the drawings printed in PDF and DWF. In the the new project I can't see the sheets from the linked file though.
Is there a way to link the sheets to another procjet?
I have linked a food service RVT model that has 1000+ pieces of specialty equipment. I've copy/pasted the tags from their file to mine. Now I want to be able to type in a tag number and have revit 'zoom to it'. Or I'd like to be able to make a schedule and use 'Highlight' option - but nothing seems to work because the elements are in a linked file.
View 2 Replies View RelatedI want to mirror cut the models "selected" portion but it gives me result very far to it which is highlighted with red in the screenshot.
View 1 Replies View RelatedIs there a way to show the description for something. Let say i made a bridge and i wanna show the description on the model that the length is 10M and the base should be this and that. i wanna show the instruction on the model so the next person who works on the project knows what this object is and what is does. it's like a blueprint.
View 4 Replies View RelatedI have several spaces with the same types of case work. But instead of having each type have a general key note, I would like each instance of the type have a unique key note similar to the way doors work.
View 4 Replies View RelatedAny way to create sheet notes in Revit? I would like to be able to point at anything and place a tag (like a circle with a letter inside) and then have a list of notes that I can place on the sheet. I don't want to have to tag a specific item (like a door or a wall), I just want the arrow to indicate a point in space (like an arrow connected to text), but have a tag at the end of the arrow instead of text then have that tag reference some sort of legend that I can place on a sheet. Is this possible in Revit? If not, why not - this is a common requirement in architectural drawings.
View 5 Replies View RelatedI am just finished a residential project modeling in Revit 2010. I am working on construction set and need to import .TXT files from previous project for general notes, code compliance report, etc. I have my custom keynote file (.TXT) for user notes.
View 4 Replies View RelatedI decided to model an industrial iron caster wheel with polyurethane tread, and all went well. Tonight I added three ribs to one side of the caster wheel, which looks great, but I would rather not repeat the process on the other side because of all the fillets and such which would have to be repeated.
Is it possible to split the wheel down the middle and then mirror the side with the ribs? I saw that I can split the model with a plane, but I can't figure out how to remove the geometry on the left side of the plane.
is it possible to change the line patern of leaders in text notes, from solid to dash or another one? I know I can change the tick type but can´t find anything for the line.
View 2 Replies View Relatedstill on this family quality control audit... i've come across some new and entertaining behavior.
several fmailies (face based) flip host sides with their flip controls as expected, but if i mirror them , instead of flipping along the mirror line as an accurate reflection, they ALSO flip top to bottom, AND around the face.
the right family in both views is the original, the left is the new mirror. (plan and elevation views in wire frame included) you can see it landed within the wall, and upsidedown.
I am using Autodesk Revit Architecture 2013. I am using mirror project from the manage pulldown under position. I have used this tool many times in the past with success. This particular home is an average size two story. The file is about 40Mb. I tried flipping the home and Revit gets to about 29% and stopps. I let it run for an hour over lunch, even over night and no luck. I tried the same house on another computer running Autodesk Revit Arch. 2013 and it did the same thing.
I tried purging the file, I made sure nothing was locked, I even got rid of my grouped items. I tried copying the plan into another "fresh" file with nothing extra (like title blocks or other families).
I do have some floor framing shown in this plan. I used structural 2x10s to produce the framing (I did try getting rid of the framing and it didnt work). I tried turning off the roof lines (it has about three reverse gables) and nothing.
linked Excel file to Inventor 12 file parameters. Windows 7, Excel MS office professional '10. Linked excel file, here dimensions are driven by parameters which are driven by excel. toggled 'immediate update' Still - i have to open the sketch - it shows the updated number from Excel, but only on opening the sketch will it change the model to use the new dimension value.
View 3 Replies View RelatedI am having trouble with the linework reading properly. I link a CAD dwg. to my revit model and once its in my model the linework doesnt read as it does in autocad. I have dashed or hidden lines in my CAD plan and once I link it in revit they show up as solid. I am thinking it has something to do with the LTscale in autocad?
View 3 Replies View RelatedHaving issue with linked DWG which disappears arbitrarily? It is still linked and the visibility of Imported categories is set to ON, but DWG is not visible in a view. When we were linking it we set Current view only (so we can not see this DWG in other view than in the particular one).The solution is to remove DWG and link it again..What may cause it is that we copied the DWG into all levels because it contains floorplans of all levels. In every level we moved the DWG into correct position and it is working for a while. We did not find a moment when it disappears .
View 2 Replies View RelatedI'm having a real issue with Revit that I can't get my head around or find documentation on.
I have a model setup and linked a DWG file. The DWG is a topo survey drawn in real co-ordinates. The DWG is linked center to center then then I moved and rotated it to suit the orientation of my new building in Project North. See image 01.
I've then aquaired the co-ordinates from the DWG.
I've change to True North and rotated the view. See image 02
All seems to be OK. If I detach and re-attach this DWG using the shared co-ordinated it ends up in the correct place so I've started work on my model.
However, I've noticed that when I close and re-open my model or force ther DWG to reload it shifts position and rotates so I have to detach and reattach. See image 03
I linked in a dwg floor plan and it shows on the first floor but not in the 2nd floor or any others views. I thought as long as you left "current view only" in the Link CAD Dialog box unchecked it should show in all views.
View 3 Replies View RelatedUsing Revit 2014, I link in a dwg file. I open a view and using V/G overides for Imported Categories, I turn off the Acad layers I don't want to see. Then the next time my dwg file is updated, the V/G will remain the same and I won't have to reset the layer views. Now I duplicate this view for additional views I need in my project. But I need to apply a different View Template to each view. This destroys the original V/G settings that I had set up for the dwg file.Is there a way to set up my linked file so that it retains the layer on/off settings through each update and lock it. Then I can apply different View Templates to introduce other characteristics without altering the desired layer settings.
View 4 Replies View RelatedI'm linking CAD files. The lines come in jagged. I think it is more of a graphics problem.
View 1 Replies View RelatedWe have multiple linked Revit files from consultants in the same hospital Revit model. How can we turn off all grids and levels in all of the linked files globally. We want to avoid having to do it individually for each view & each linked file.
This project is currently in Revit 2011. If not 2011 is it possible in 2012?
I thought that Cut Profile would be working with linked models (with By Linked View) by now. I know it didn't work a few years ago, but we've just tried it in 2014 and it still isn't correctly displaying views that have had the Cut Profile tool used on them when linked into another file (using By Linked View).
View 3 Replies View RelatedI have several architectural models linked into my central file on a project. For this project, there is an addition to the building that is a design option. When I look at the linked files, though, I can only see the existing construction. I also know how to copy/monitor levels, but I want to view the architect's room elevations in my model. How can I copy the architect's design options and specific views into my model?
View 1 Replies View RelatedQuick question, do shaft openings work across linked files? I have an elevator file I have linked into the main file. It has a shaft opening but doen't appear to be cutting holes in the floors inside the main file.
View 1 Replies View RelatedRevit 2012 .I have a topo file linked to the main building file.I am trying to render a 3d exterior view of the building (new construction ).I see the linked topography in black lines in my elevations.but not in the 3d view.
The question/ problem unsolved is how to get the site/ ground to be visible as per the linked topography in the 3d view of the main file . All I see is the building in the air , with a very light greyed site in a block form. I would like to see the site in earth: soil material for me to render the exterior view.
We have a structural model linked into our building model for a project with about 10 people working on it. Periodically, some users cannot see all of the elements in the linked structural model. We have tried/checked the following:
Checking Visibility/Graphics (Worksets, Links, Categories)
Checking Reveal Hidden
Opening/Closing Worksets
Unloading and reloading the Links
Opening different Views to find the Elements
We are unable to resolve the problems through the methods above. Oddly, when a different user opens the view the elements are displayed. Or, if we override via Visibility/Graphics to the linked model settings the elements are displayed. In this second sceanario the only way to control the graphics is by changing them in the linked model.
Nethier workaround is efficient or productive.
"Can a color scheme be copied between non linked projects or does it have to have existed in the template view or be re-built in the new project view? I am surprised it can't be 'transferred' with other project standards, unless you can tell me different?"
View 1 Replies View RelatedI linked a revit file of some renovations that had been done into an older revit file. This worked fine accept it did not transfer the room data over. When i try to put new rooms in they take the volume of the older rooms not the renovation imports. Why? Why? and why?
Even if I draw out the rooms when i place the room they are still separated and defined by the older room dimensions. Thats not cool that is sad?
I linked in a cad.dwg survey into my Revit model and I don't like the result. I'm trying to unload or remove the linked file now and I get an error message, "A serious error has occurred. It is strongly recommended that you use Save As to save your work in a new file before continuing."
Saving to a new file does not change this problem. I've tried cleaning up the survey file, moving the file to another location, changing from relative to absolute path. Revit shouldn't even be finding this file any more. Isn't linking similar to x-refing in AutoCAD?
How to get this dwg out of my Revit file?
Baffing issue for us:
We have a "core & shell" model linked into a "fit-out" model. We are working with design options in the "fit-out" model with different design options.
1. In a 3D axo view and working in the main model, we can see the linked "core & shell" file.
2. In the same 3D axo view and working in the primary design option, we can see the linked "core & shell" file.
3. In the same 3D axo view and working in any of the other design option, we CANNOT see the linked "core & shell" file.
The visibility & graphics settings have not been changed. The worksets settings have not been changed. We have been unable to overcome this issue. We are simply flippiing between different design options and the linked model disappears.