Revit :: Grid Line Visibility?

May 7, 2013

I created a building section and all grid lines appear.  I selected all grids that I want to appear in the building section, switched to 2D, and adjusted as desired.  From that building section I created a callout for a stair section detail.  In the callout view, some grid lines appear but not all grid lines appear.  I turned off crop view but they still do not appear.

View 1 Replies


ADVERTISEMENT

Revit :: How To Offset A Grid Line

Sep 19, 2012

I am using 2013 version. (don't find a "lock" under toolbar.I am a student with only AutocadLT experience.  I can not find how to offset a grid line.

View 1 Replies View Related

Revit :: Vertical Curtain Grid Line

Oct 29, 2012

I've created a non-symmetrical curtain wall mullion profile.  When I assign that profile to a vertical curtain grid line, it is flipped in the project.  In the attached image, you can see that the brace on the right in the family plan view is on the left in the project plan view.

View 9 Replies View Related

Revit :: Unable To Select Curtain Wall Grid Line

Dec 3, 2013

Something has happened and now I cannot select grid lines in curtain walls.  I can tab to highlight the grid line (dashed blue line) and click once.  This used to make the grid line a more solid blue and witness line dimensions appeared.  Now the cursor becomes a "move cursor" (four arrows), the grid line highlight disappears and there are no witness lines.

Nothing is pinned.  The vertical grid pattern is not fixed.  I've restarted Revit and I still can't select a grid line like before.
 
This problem started when I tried to change a grid line in a curtain wall that I forgot was part of a group.  It let me select the grid line and when I changed the witness line dimension value there was an error message with no information except for entity ID and a cancel button.  After that I could no longer select grid lines in this project.  If I copy and paste a curtain wall from the project to a default (see attached) I cannot select there either.   I can still select grid lines in other older projects, however. 

AutoCAD 2010
AutoCAD LT 2013
Revit Architecture LT 2013

View 8 Replies View Related

Revit :: Curtain Wall Mullion Isn't Aligned With Grid Line

Nov 4, 2011

I'm having a bit of trouble using a curtain wall BIM model that I downloaded from a manufacturer's web site.
 
It seems like the vertical mullions are not centered on the grid lines; one side of the mullion is 1 3/16" from the grid line while the other is 1 13/16" away. If you look at the mullion in plan, you'll see the same issue. If you look at the profile rfa file, it appears that the centerline is properly located and locked, it's just in the project file where it's off.
 
 If I select the mullion in the browser the right-click, Make Element Editable is grayed out.

 If I select the mullion in the drawing area, un-pin it and then right-click, Edit Family is grayed out.

 If i select the mullion in the drawing area then click Edit Type, the Type Properties dialog box shows the two parameters in the Dimensions group, "Width on side 2" and "Width on side 1", that are uneven by the same amount that the mullion is off of the grid line. I suspect that this the issue, but these are both grayed out and I can't locate their origin. If I duplicate the mullion, those parameters are still grayed out.I can save the profile, but not the mullion, which is showing the issue and contains the parameters that I want to change. How I can select and edit the mullion?

View 2 Replies View Related

Revit :: How To Locate Lay-in Ceiling Grid With Grid Intersection In Center Of Room

Feb 16, 2012

Revit has a propensity to locate a lay-in ceiling grid with a grid intersection in the center of the room. You can use the alignment tool to align the grid with a wall. But I see no way to center a tile in a room. This is often a necessity in a narrow room, to keep the lights centered. Also, installers, when not given specific instructions to the contrary, will often locate the ceiling grid to minimize narrow tiles at the wall. We need more control over the position of the grid.

View 1 Replies View Related

AutoCAD Architecture :: Ceiling Grid Visibility

Mar 23, 2010

I'm using AutoCAD 2008 and trying to make a smart ceiling grid using the tools palette. The tool runs fine, however my grid doesn't show up in my drawing. I checked all my layers and they're fine. I think my ceiling grid visibility display is turned off.

Any command to turn it on? Checked the product, it gives me options to turn it on/off when it's already visible in a view, but this doesn't work since I can't see it at all.

View 6 Replies View Related

AutoCAD Architecture :: Column Grid Visibility In Elevations Or Sections

Aug 25, 2011

Using Architecture 2012 and seem unable to get a column grid to show automatically in elevation views. Looks fine in plan view, bubbles etc all working once we sorted out annotative setting .

View 3 Replies View Related

AutoCAD Inventor :: Line Visibility In IDW?

Jan 9, 2013

Using Inventor 2013.  In an IDW, I have toddled off visibility of lines in a view.  I would like to regain visibility of these lines.  HOW?

View 2 Replies View Related

Revit :: Visibility By Level In 3D View?

Mar 9, 2012

Is there a way to set the visibility of elements in a 3D view according to the Level they are associated with?
 
The VG tab which opens the filter dialog provides a check box for the "Levels" category, and the relevant parameters are made available.
 
But I can not seem to create a filter rule which evaluates any of those parameters (name, elevation, etc...) to then isolate the visibility of those elements in the 3D view that either meet, or do not meet the criteria. Nothing seems to work.
 
To achieve a "similar" effect in a 3D view, I can use a Section Box, but that is a very clunky and imprecise way.I can also create a Shared Parameter for "Level" and perhaps filter successfully that way, but that seems redundant with the Levels intelligence already established.

View 7 Replies View Related

Revit :: Turn Off Visibility Of Dimension With Zero Value

Jun 5, 2012

I'm using BIMLink to adjust parameters in a model... If a dimension ends up being zero, is there a way for me to have conditional formatting to turn off visibility of a dimension with a zero value?

View 7 Replies View Related

Revit :: Roof Visibility For Underlay

Jul 18, 2011

I've attached a couple images of a visibility problem I'm having. The ROOF image shows the underlay view I'm using in the NO ROOF view in my revit project. I modeled all four of the dormer roofs the same, in place roof components, and they show up in the roof plan, but not when I use the roof plan as an underlay for my framing plan.

They don't show up when I toggle on the hidden elements tool either. I checked to make sure I didn't have coarse scale visibility turned off as well as if I had not visible in plan unchecked. These things seem fine, plus, as you can see, it shows up in it's own view. View range seems to be fine too. I can't figure out why these elements don't show up.

View 4 Replies View Related

Revit :: Family Creation Visibility

Dec 13, 2012

I know I must just be missing this somewhere, but I would like to shut off the geometry inside a family that's associated with a specific parameter.  This is while I'm editing the family.
 
Specifically, the family I'm creating is for an appliance that has the option of an arched, or rectangular opening.  Once I associate the geometry for the arched opening with a parameter, I'd like to shut that off, so that I can create the rectangular opening.  Similar to how the family behaves once it's brought into a project.
 
Right now, I'm just kind of using the temporary hide functionality to shut them off, but if I turn them on, then have to go back to make edits, I have to select the individual geometry all over again to hide it.  I've also noticed that some geometry, even when hidden, can still be selected.

View 8 Replies View Related

Revit :: Visibility Of Non-structural Walls?

Apr 8, 2013

In my 3D View my walls disappear when I de-select the structural box.  Although drawn as regular walls they are store front panels so carry no load other than their own weight.  My Visibility Graphics dialog box seems to have limited options for this. Am I missing something?  How do I get them to re-appear in my 3D View for rendering without switching them to a structural wall?

View 2 Replies View Related

Revit :: Visibility Control Formula?

Nov 12, 2013

I'm facing a problem dealing with visibility formulas... My situation that im dealing with is, I have 2 yes/no visibility parameters, one that is called Right side clearance and another one named Left side clearance. I want to create another yes/no visibility parameter that's called Clearance. I want to link the Right and Left clearance parameter to the Clearance parameter where if it is off, then there will be nothing that shows.. But if I want it on then I would have to select either right or left without them both showing up?

View 4 Replies View Related

AutoCAD Civil 3D :: Profile Line Visibility

Dec 10, 2012

I'm doing a road project. i've got profile grades of existing left and right ditches. in some sections we're redoing the ditches so i've got proposed left and right ditch profiles. what i want to show is where i've got proposed ditch grades, i don't want to show existing ditch grades.

The new ditches happen intermittently on the road so i would need to be able to turn off the existing ditches at various places. is this possible without exploding my existing ditch grades?

View 9 Replies View Related

Revit :: Visibility Of Beam In Plan View?

Jul 15, 2011

If i draw a beam in plan view en define the height, the beam disepare. Is there a posibility that the beam is in place and you can see a dash dot line and two dashed lines in plan view?

View 1 Replies View Related

Revit :: Visibility Of Topographic Surface Edges

May 20, 2013

In Revit LT 2014, I've tried unsuccessfully to override the color of topographic surface edges in my model to white, so the edges don't show up in plan views.  I've tried through the Object Styles menu, Override Graphics In View By Element, and Override Objects In View By Category, but nothing has worked.  These overrides have worked for me in the past in previous Revit Arch versions, so I don't know if LT just doesn't have that capability, or it's a bug. 

I can't simply extend the topo surface past the view window edges (I only want to show contour lines on my site, since they've been surveyed, but the neighboring site has not been surveyed, so I don't want to guess at them).  I really just want to hide the toposuface boundary edge. 

View 1 Replies View Related

Revit :: Turn Visibility Off On Border Of Text

Mar 18, 2013

I am trying to tag doors in a drawing. What I want to see is the door size, so I turn on 'width' parameter, and turn visibility off on the border of the text. Change the size of the text to match, easy enough. Now I want to place the text along the open door in the floor plan view, but the tag always jumps to the center of the door frame. Can this be modified to do as I want? is there an alignment parameter I can alter? Perhaps tagging the  door family and aligning it in the family editor? Does Revit is capable of doing this. Until then, I have to place the text for each individual door.

View 2 Replies View Related

Revit :: Correct IFC Exports Using Visibility Parameter

Mar 4, 2012

I find the visibility parameter a very useful option when building families. Unfortunately it doesn't work when exporting IFC. The elements set to not visible are visible in the IFC exports.
 
I also experienced IFC export issues with the use of phases.An element created at phase 1 and set to demolished at phase 2, will not be visible in the IFC export of phase 1.
 
The IFC Exporter for Revit 2012 v1.0.4.msi was used when running into these issues.How to be able to have correct IFC exports using the visibility parameter ?

View 4 Replies View Related

Revit :: Global Visibility Of Linked Files?

Jul 26, 2011

We have multiple linked Revit files from consultants in the same hospital Revit model. How can we turn off all grids and levels in all of the linked files globally. We want to avoid having to do it individually for each view & each linked file.
 
This project is currently in Revit 2011. If not 2011 is it possible in 2012?

View 4 Replies View Related

Revit :: Visibility Of Sub-objects In Nested Family

Aug 13, 2012

I've created a family for an exterior canopy system that has many variations (see attachment).  It works for all options except the final request from the intended users.  When the canopy is very short, the interior outriggers do not need cable tiebacks to the exterior wall.
 
Currently, the outrigger family, which is nested and arrayed in the host family, is composed of multiple objects, four of which comprise the cable support that needs to be able to be turned off, and one that is the outrigger that is always visible.  I've tried several ways of getting the cable assembly to turn off while leaving the outrigger visible, but all without success.  I've tried editing the array and mapping the cable assembly components' visibility parameter to a Cable Option Yes/No parameter.  I've tried making the cable assembly its own family and nesting that first in the outrigger family and then mapping its arrayed instance to a Cable Option parameter.  I've tried various combinations of Instance versus type parameters in both the Outrigger and host Canopy families, all to no avail.
 
Given the way the family is now designed, can this be done or must the cable assembly be its own family and arrayed separately?  Note that there are parameters to control the cable assembly size.

View 7 Replies View Related

Revit :: Fat Colored Outlines After Turning Off Visibility?

Dec 20, 2011

I need to create some exterior snapshots of our model, which has just been completed to the 100% DD phase. The model has another Revit model linked in: the structural elements from our structural engineer. In the exterior shots, his pilings are showing and we don't want to see them in these images, so in the views I created I turn off his Structural Columns (which is the category for his pilings) in Visibility/Graphics Overrides. The pilings go away, but all of his elements now show with a fat colored line surrounding them.
 
Two questions: why are these lines showing when all I have done is turn off a model category in Visibility/Graphics Overrides? And how can I now turn off these fat lines? They do show when I create a PDF of the image.

View 4 Replies View Related

Revit :: Family Elements Visibility In Project

May 23, 2013

I am trying to do the travel distance plan for fire cert saftey plan (Ireland). I have 6 levels of plan. When I place a component of "travel distance" family symbol (that I created) on the top floor plan, it is showing on the ground floor plan but not inbetween (TG).  
 
See attach.

View 3 Replies View Related

Revit :: Family Elements Visibility In Project?

Jan 15, 2013

I'm trying to make a project-file for a table that I've made as a family. In the project file I want to dimension the table, as a whole and as the differents parts of the table.

I've made visibility parameters in the family, but my problem is that that will hide that part of the table, i.e. the legs, in all views. I want to have one section with only the table top, one section with only the legs etc.
 
how I would go about this without copying the table in the project file and hiding different parts in each of them?

View 2 Replies View Related

AutoCAD Inventor :: Line Visibility Through Solid Parts?

Oct 2, 2012

I am working on a cylindrical part, and I need to CAD an internal feature for the part.  I set up a parallel plane at the point within the geometry that the feature is to be located, and am attempting to sketch the profile of the part using the 2D sketch feature.  However, the lines that I am sketching are not visible through the rest of the existing cylinder, for example, if I have draw a 30 mm line from the centre point of a 20mm radius cylinder, only the final 10 mm of the line will be shown.  While the line is still functional, it is highly inconvenient when trying to sketch these features, they are difficult to work with as I can not see them through the part. Is there any way to set the defaut visibility for 2D sketches to be so that they are visible through solid parts?  

View 3 Replies View Related

Revit :: How To Create No / Yes / Visibility Parameter For Title Block

Jun 27, 2012

How to create a 'No/Yes' or visibility parameter for a title block?  I have my Architectural Seal as an image inserted into my title block family.  I want to have that as a parameter for visibility so I can have it turned off until I am ready to print for final building department submission filing.
 
If possible, this would be a global adjustment so I would operate this parameter once and will affect all the sheets in the project instead of having two title block families and swapping those out at the time of filing.

View 3 Replies View Related

Revit :: Light Fixtures - Controlling Visibility Graphics

Jun 12, 2013

I am trying to figure out why the light fixtures are giving me these thick heavy black lines.  The same fixtures in the arch floor plan are close to what I want (see arch1).  However in mech1.jpg there isnt a way I can find to make the lights more like arch1.jpg.  I dont want to use an architectural view template on a mechanical plan, which seems to be my only temporary solution.  This is not an issue of Thin Lines (TL) setting and I have tried object styles and VG, although I must not be looking in the right area. How I can control this?

View 1 Replies View Related

Revit :: Visibility Graphics / FilterRule Cannot Make It Work

Jun 14, 2012

When I try to create a filter, I cannot get the Filter Rule to work.  Under Filter by there is an option to select More Parameters  which then directs you to Project parameters.  When I select a parameter, it does not show up in the 'Filter by' box so I can create the rule.  I have used this feature in 2011, but I cannot seem to make it work in 2012. 

View 1 Replies View Related

Revit :: Visibility Of Lines Placed In Front Of Filled Region?

Nov 20, 2013

I have created a 'Title Block' family which I am wanting to use as a 'drawing stamp', being used to mark an existing drawing sheet carried forward to another phase of the project as being from the previous phase.  To do this I have created a filled region with an opaque white background and a grey border (gray) to form the extent of the 'stamp'.  I have then created a number of labels for the relevant information and added some lines as borders to the labels.

The problem comes when it is used on a project sheet since the label border lines do not appear.  Since the commands to 'send to the back' or 'bring to the front' are absent when editing a title block I wonder why this is?  Logic suggests that the only workaround is to create a number of filled regions, in jigsaw style, one for each label and to use their borders as the label borders.  However, this seems an enormously long winded an probably kilobyte hungry way of achieving something that should possibly be very simple.  I have to say that it may also have an easy solution that I may have used before but forgotten.

View 2 Replies View Related

AutoCAD Dynamic Blocks :: Visibility Making Line Disappear

May 10, 2013

The problem happens in different blocks created in Autocad 2009. I need to make blocks with many visibilities and, sometimes, only a few lines need to be turned invisible from a visibility state. Many times when I remove the visibility of a line from a single visibility state, the line erased on all the visibility states. I make my lines "all visible" and it's not there anymore. 

The problem is probably in my block since it's doing the same problem on someone else's computer. If the problem is my block, is there a way to "uncorrupt" it?

View 1 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved