Revit :: Filter Wall Schedule By Type?
Jun 8, 2010
I am trying to make a schedule and I need to schedule walls, and filter by type. But this option is not available in the view properites/filter options in the schedule.
Is it possible to make this happen without creating an additional parameter for filtering? Which would also open up the potential for omissions in the schedule.
View 5 Replies
ADVERTISEMENT
Jan 3, 2012
What kind of an instance paramater needs to be implemented in order to account the host wall type in the door schedule?
View 2 Replies
View Related
May 22, 2012
how to create a wall schedule with areas. To find out how much plasterboard, paint etc. I need for a building.
View 1 Replies
View Related
Apr 12, 2012
Any way to get a wall sweep that's set up in the type/structure properties to follow a wall if that walls profile has changed. For example, in the image below, I've split the wall and adjusted it's profile to create some cheesy angled parapet. How do i get my wall cap to follow along? I thought splitting it and changing it's height would work, but no. And if I change the profile without splitting the wall the wall cap just runs right through the wall, as if the profiel was never even changed.
View 3 Replies
View Related
Oct 31, 2013
When I try to change the length of a wall it grows at both end. How to grow at one end only?
When I change the wall type to one with a different thickness, I cannot control which face of the wall remains fixed and which face moves. eg: change from 130mm to 250mm screws up my room width. How do I do this?
View 1 Replies
View Related
Jun 11, 2012
Our model uses several material types for insulation, mostly rigid variations at this point. The various materials are used in floor, wall and roof systems. Is there a way to create a single schedule that would list insulation quantities across all three system types?
View 2 Replies
View Related
Aug 11, 2011
I would like each type of light to only be listed on the schedule once. The schedules seem really unstable, everytime I look at it the whole thing has changed. There are so many extra items listed and I don't know where they came from. The mark numbers are weird like AAAA, AAAAAA, BBBB, BBBBB. I don't know how these got added or why they have such strange marks.
View 4 Replies
View Related
Feb 8, 2013
In a recent meeting wtih cilent, we asked her to review the Finish Schedule. She pointed out that one of the ceilings was supposed to be gypsum board rather than ACT. Looking on our RCP, it was showing gyp board, but the schedule, which is populated from the Room Properties, was calling out (the non-updated) ACT 2x2.
Is there some way to link the ceiling type directly to the finish schedule directly, rather than make double changes (updating the room properties and the actual ceiling type) in order for the proper information to be showing? Seems odd and not very useful to have this kind of redundancy and something that should have been worked out long ago in Revit.
View 1 Replies
View Related
Jul 10, 2012
Is there a way to change the font type and size of the Level within the schedule?
View 1 Replies
View Related
Dec 18, 2013
We usually run our own calculations for U Values using the BRE Calculator (UK Building Research Establishment).
I just carried out an experiment to check the value that appears in the Revit properties of a wall type (Heat Transfer Coefficient - U) for a given wall build up.
The result in Revit does not seem to correlate with the value that our calculator generates.
I have checked through the conductivity values for the materials (under thermal properties) - and using the exact same values the Revit generated figure is far more optimistic.
For a typical cavity wall construction:
Brick (102mm) @ 0.54 W/mK
Cavity/air gap (40mm)
Insulation (60mm) @ 0.020 W/mK
Block CME (100mm) @ 0.51 W/mK
Plaster (12..5mm) @ 0.51 W/mK
The value that appears in the Wall Properties Dialogue box (greyed out - so I assume it is a calculated value) is 0.1935 W/m2K
Our BRE calculation generates a figure of 0.268 W/m2K.
The insulation manufacturer claims around 0.25 W/m2K for the given wall build up.
how we could have such a discrepency ? All the conductivity values are correct for the materials used in the wall build up.
I am beginning to wonder whethe the value in the Wall Type isn't a U-Value, although the units are consistent with it (W/m2K)
View 6 Replies
View Related
Dec 13, 2010
Is there a simple way to change a wall type without deleting the wall and redrawing it in the new style?any time i change the wall type it changes all walls?
View 9 Replies
View Related
Jul 11, 2012
In the properties drop down list for wall type selection, most of the different wall type are not showing. Also my elevation carmera is not showing when i click on a new drawing. In a previous drawing all walls selection type is there and the elevation camera. Only when i start a new drawing when wall type and elevation camera is missing. I check the interface to make sure the boxes are check.
View 1 Replies
View Related
Oct 6, 2011
I am having a problem with creating a curtain wall system. After selecting my mass surfaces and choosing "create system" I am unable to change the type of curtain wall system. It just comes up with a regular grid system on the mass, where as before I was able to choose triangles, rhomboids etc under the properties tab. Now however I see nothing except for the current curtain system and recently used files.
I have also created a custom panel which I want to insert into my project but am unable to do so? I have tried loading it into the project, however because of the above problem I am not able to change it to my custom panel system.
View 5 Replies
View Related
Jul 25, 2013
I have to draw a bulkhead wall that connects to a full height wall and a gyp bd ceiling. This causes the entire end of the full height wall to skew in line with the butt joint above the ceiling level. I tried Wall Joins but all the options screw up the bottom half of the wall which needs to remain in line with the paired opposite. I also tried editing the sketch of the wall profile but Revit couldn't keep the elements joined. I tried trimming the two walls back together afterwards but the wall profile dominates and prevents a clean join above the ceiling.
Surely there's a way to have different kinds of joins at different heights?
View 9 Replies
View Related
Dec 4, 2012
I am trying to align the curtain wall with the edge of the concrete slab/face of wood framed wall (Core). I have tried to align and move however the whole wall moves as well as the edge of the slab. How I can move the Curtain wall leaving the other elements in place?
View 2 Replies
View Related
Nov 27, 2011
Refer to the attached file. How can I cut the RED part of the Wall 1 (W1) , where Wall 2 is sloped. I also want to cut a hole in wall 2 (W2) by the BLUE rectangle , but why I can't do that .
I also want to add a second floor to my project but I can only see the" Level" icon goes grey and I can't click it.
View 1 Replies
View Related
Apr 16, 2013
I am trying to make a floorplan of my house in Revit 2013, but I am having an issue when it comes to one wall in my house. I have an opening in the Master Bedroom that leads to the bathroom. This wall has a weird arched-like opening in it and I have no clue how to make this in Revit. I have attached a sketch.
Also, my exterior walls are 7' tall but the interior walls start at 7' and go up to 8' once in the middle of the house and reduce back to 7". How does one set that up in Revit?
EDIT: May have made the image too small to see, but the top is not arched, it is actually half of a decagon.
View 3 Replies
View Related
Jul 29, 2011
I have a question about wall profiles. I want to make a profile on a wall so I can make Zinc Panels on the wall that are 10" X 20". I've attached a picture of what I'm going for. I'd like it to have a 1/2" spacing between them and with a joint depth of 1" and I'd like to do this is the wall type so that I can use this wall in multiple places rather than having it model-in-place. Anyway I have made a profile that is 1" X 10" so that it can become my panel profile. But when I go to add it to the wall as a wall sweep as I have seen people do I get hung up on how to make it tile up the wall and also I don't understand how to make the profile so that it is 20" wide. I have a screen shot of where I'm editing this too. Below is the link of the site.
View 8 Replies
View Related
Apr 7, 2013
“Drag wall end” to the edge of the wall (indicated),In the attached screenshot, I wanted to drag the end of the temporary dimension from its location to the end edge of the wall but sounds not to respond!
How this temporary dimension can be dragged to the edge of the wall?
View 3 Replies
View Related
Dec 30, 2011
Is there a way to have more than 4 filters for a schedule?
View 2 Replies
View Related
Aug 6, 2011
I can create structural column schedule but i cant create for architectural columns.i wonder that i do something wrong or simply i cant be done?
View 1 Replies
View Related
Feb 22, 2012
Is there a way to add new parameters to revision schedule
View 2 Replies
View Related
Apr 9, 2013
Is it possible to control if the door tags is displayed by the schedules?
View 4 Replies
View Related
Oct 7, 2011
Is there a way to add additional filters to a schedule? I have a sheet list that needs a total of 6 filters.
View 1 Replies
View Related
Dec 7, 2013
how to do the parameters of Schedule/Quantities.
View 9 Replies
View Related
Nov 2, 2012
How to export a schedule from Revit to Excel,
I’m wondering if there is a way to export schedule from Revit to Excel..
View 2 Replies
View Related
Feb 28, 2013
We have a custom built schedule which has the typical "Comments" field. As we aork in our project and add items to that particular row, the "Comments" field gets reset to be blank.
What we are trying to do in effect is to establish a reference point so the we know where we are in relative to the reference point.
Is there a way to make the "Comments" field stick?
View 1 Replies
View Related
Jul 18, 2008
is there any way to schedule objects by id number?, maybe through a formula within the schedule that may call the id or the revit API and if that is the case
View 2 Replies
View Related
Nov 7, 2011
I've been trying to style my sheet list schedule. ... trying.Is it true that I can't
* style (fontsize, fontweight etc) a 'sorting header'?
* style the scheduleborder to only underline the sheetlist-rows
* seperate the header styles from sheetlist styles? (I don't want the header to have a border.... while sheetlist-row should be underlined)
* format the height of a row
View 2 Replies
View Related
May 29, 2013
I am trying to add the typical category of "glazing" to a door schedule, but when I add a door with glass into my project, I cannot make this information show up on my schedule. I need typical information such as "!/4" Temp" and "1" Insul" under the category of glazing. I added the "Door: Glass" heading in the schedule, but nothing appears when I add a glass door into the project. I was able to easily do this in AutoCAD Architecture.
View 5 Replies
View Related
Jul 15, 2012
I am having trouble creating my own column and beam
structural column schedule
structural framing schedule
i do not know the settings to be ticked for me to create the schedules and make them appear after i create new scheduling...
also i want to know how the graphical column and beam works...
then setting the level in the schedule to make them reflect instead of using the comments section...
Attach here is a screenshot of the levels...
View 3 Replies
View Related