AutoCAD Civil 3D :: Part Masking With Multiple Networks?

Sep 29, 2013

i utilize part masking in my profile structures but it only works with connected pipes not other networks pipes.

Besides wipeouts, how do you get around this?

View 9 Replies


ADVERTISEMENT

AutoCAD Civil 3D :: Pipe Networks - Connect To Part

Jun 5, 2013

I have a 18' x 10' special structure where I'd like to be able to connect the pipes as shown to the structure but I'm not aware of any way to force the Connection point of the pipe to the desired location along the structure.

Normal behavior is to connect all pipes to the same insertion point or center of structure.how to go about maintaining pipe connection orientation to reflect the design requirements?

View 9 Replies View Related

AutoCAD Civil 3D :: Pipe Networks With Multiple Pipes?

Mar 15, 2013

Is it possible to simultaneously create a pipe network with multiple pipes?

View 5 Replies View Related

AutoCAD Civil 3D :: Equivalent Command To Swap Part In 2014 Pressure Networks?

Sep 17, 2013

I've been searching for a method to swap the pipe size of an existing Pressure Network in 2014 Civil 3d.

Is this still not possible? The size listed it's grayed out.

C3D 2012 SP3 & C3D 2014 SP1
Win 7 Professional 64 Bit

View 3 Replies View Related

AutoCAD Civil 3D :: Labeling Pipe Structure On Profile With Multiple Networks?

May 7, 2013

I have an existing pipe network and a proposed pipe network.  When I label a structure in my profile view, how do I combine the different network information?   (Or do you usually have one network for both proposed and existing?)

For example, I have an existing pipe that will remain, but I will replace the structure and connect it to new pipes.  On my label, I want to label proposed structure, pipes, and existing pipe using italics.

View 2 Replies View Related

AutoCad :: Masking Part Of A PDF Underlay?

Aug 31, 2012

I'm working with ACAD 2013. I need some way of masking part of a PDF underlay. Basically I am attempting to call out something on architectural plans and create a listing on a table. The mask needs to be transparent, kinda fading the rest of the plans out, leaving my little callout box.

The ways I can think of doing this involve a little trickery. I think if you bring the PDF (2) times create a clip then create the opposite clip then turn the fade up on the outer one should work.

View 1 Replies View Related

AutoCAD Civil 3D :: Multiple Part Swap

Oct 13, 2009

[ URL]............

One of the problems we face in 2010 is the part labeling issue, where it labels the family name for a part and not the description name. The way to get around this was to do a swap part. Well for me when i lay out a storm network, i create it by pipes only and then swap the parts that i need to. The only flaw about this is that you can only do one swap part at a time.

Well if you go to civl3dreminder blog site there is a fix for that. I actually tried it and it worked. I was actually able to swap pipes and structures at the same time. This routine will definitely come in handy.

View 2 Replies View Related

AutoCAD Civil 3D :: Duplicate Pipe Networks

Nov 28, 2012

Somehow I copied something and now when I open my drawing I have deplicate pipe networks with one being named something like Pipe Network and the 2nd being named Pipe Network(1).  Pipe Network(1) does not show up in the toolspace.  It has duplcated every pipe network in the drawing.  I deleted all the pipe but when I close and reopen the drawing it comes right back.  I've attched a pic.  The single line is the original, the double line is network(1). 

View 6 Replies View Related

AutoCAD Civil 3D :: Using Pipe Networks For Utilities

Jan 10, 2013

On a waterline that I am currently working on, we have existing utilities (gas, fiber, electric, etc.) surveyed and need to display those on our profile.  Typically we will determine the crossing locations and offset those x' below the existing ground.

The problem I am having is that in a mile and a half of waterline, there are 100+ crossings.  Creating a pipe out of each of those, applying the correct pipe type and display, naming the pipe network, etc, is too time consuming.  It's faster to draw them on our profile manually.  Also, with 100+ pipe networks, it slows down the drawing considerably.  And if we create data shortcuts, then we have to create a reference to 100's of pipe networks in our plan and profile sheets.

View 9 Replies View Related

AutoCAD Civil 3D :: Convert Pipe Networks To Polylines

Jul 1, 2013

I have a drawing that started as a pipeline network and am trying to easily convert the pipes to polylines or something of the sort to export to shapefiles.

View 4 Replies View Related

AutoCAD Civil 3D :: Editing Labels And Pipe Networks

Aug 15, 2013

On my drawings when I want to edit a label, I click the label, the ribbon changes and gives me options for that label, I click "edit label group" then a dialog box for that label style pops up and gives me more options.

Same drawings on another employees workspace, after clicking the label the ribbon changes, "edit label group" is selected from the ribbon, the command line then asks to pick a label you would like to edit even though you already selected a label. 

What is the issue here? Does a system variable need to be set to "1" instead of "0" somewhere?

View 2 Replies View Related

AutoCAD Civil 3D :: Modifying Pressure Pipe Networks

Jul 23, 2013

I layed out a pressure netowrk horizontally using 6" pvc pipe.  It includes some 45 degree bends and such and even some curved pipe.  Now the engineer wants to adjust the alignment in the area of the curved pipe.

First of all the modify area in the ribbon on the plan layout tools for pressure pipe is an absolut joke.  It lets me break a pipe (which deletes one end of it), move a pipe (but the attched pipes don't move), or slide a pipe (whatever that's supposed to do).

If I grip edit a curved pipe, this will not work.  The curved and tangent pipes will now no longer be tangent to each other and when laying out an alignment on the pipe itself, the curves will not work correctly when going to stake it out.

View 2 Replies View Related

AutoCAD Civil 3D :: Pipe Networks In Profile Views?

Nov 19, 2012

Is there anyway to have the Pipe Networks tab of the Profile View Properties dialog box default to having "Show only parts drawn in profile view" selected automatically?

View 4 Replies View Related

AutoCAD Civil 3D :: Pipe Networks In Section Views?

Apr 12, 2011

I would like to show a pipe network structure on my section view. The catch- the structure is 10' away from my sample line. Is there any way to project structures onto section views? C3D 2011

Civil 3D 2012 SP4.0 Windows 7 Enterprise 64-bit
C3D 2014 SP1
Dell M6600, Core i7 @ 2.3GHz, 16 GB ram
Dell T3500 workstation, too much ram to post

View 9 Replies View Related

AutoCAD Civil 3D :: Pipe Networks In Cross Sections

Jul 24, 2012

I am having an issue with the pipe networks drawing the pipes incorrectly in the cross sections. Whenever there is a crossing pipe running parallel with a structure, the pipe shows as a large ellipse instead of showing the pipe walls.

Some of the pipes are not running exactly parallel with the sample line, but they are pretty close. I know in the profile view you can change a setting to make a pipe show as a pipe end or as a regular pipe. Is there a setting for the cross sections as well? If not how do I get the pipes to show correctly? 

View 5 Replies View Related

AutoCAD Civil 3D :: Pressure Pipe Networks In 2013?

Aug 2, 2012

So I wanted to put my existing 2d linework for a water main into a pressure network.  I have done quite a bit of reading about pressure networks and the lack of different pipe materials and apputenances to choose from.  It seems as though the fittings are all there for the most part.

The way I understand it is the only pipe material that is shipped with C3D is Ductile Iron and if you want PVC or something else, you open the content catalog editor and change the dutile iron pipe to polyvinyl chloride (PVC).  Am I on the right track here?

As far as appurtenances go, when I open up the Content Catalog Explorer there is nothing for hydrants, valves, wyes, etc......  Is the only thing I can show then bends?

View 2 Replies View Related

AutoCAD Civil 3D :: Imported DEM File And Changes All Of Pipe Networks

Jul 19, 2013

I have been working on a site layout, and the engineers changed the final topo. I have imported a DEM file, and changes all of my pipe networks to reference this final grade. But all of the pipes I have placed do not reference this surface, but all of the networks do. Other than changing all of the pipes individually (which is what I have started to do through Pipe Properties) is there a quicker and easier way to have all of the pipes reference my new surface, and also is there a quicker way to apply my rules to this new surface other than the same way (through Pipe Properties changing my rules, and right click to apply rules).

View 3 Replies View Related

AutoCad 2D :: Deleting Masking On Multiple Text Boxes?

Apr 11, 2012

I am having a problem with a blueprint for a house. the plan was sent to me dwg. We use pdf factory to print the plans. This leaves a black spot where ever the dwg has mask on the dimensions. Which happens to be throughout the plan and it will only let me take it off one text box at a time. There is way too many dimensions in the plan for this to be practical. how to remove this mask from all? I am using autocad lt and pdf factory to print.

View 4 Replies View Related

AutoCAD Civil 3D :: Exporting Pipe Networks To Setting Out Engineer

Jan 10, 2013

I have created a complicated 3D utilities model using pipe networks. All the clashes have been ironed out, the 3D DWF looks great when rotated, the client is happy. Now It is time to hand it over to the contractor to build. He hasn't got Civil 3D and isn't going to get get it. He either want's the information as an x,y,z, text format or a 3d polyline. I cannot see anyway of doing this with the tools available.

View 9 Replies View Related

AutoCAD Civil 3D :: Pipe Networks - Invert Display Order

Feb 1, 2012

We are in the process of updating our pipe network structure label styles. The styles are displaying the inverts in a random order (Please see caption)  & we'd like to show the inverts in descending order from highest pipe as first text string & lowest pipe as bottom text string. Is there a way to globally tell civil 3d to always use a descending invert order? Only fix we've found is to disconnect & reconnect the parts in order to adjust invert order.

C3D 2012 SP3 & C3D 2014 SP1
Win 7 Professional 64 Bit

View 6 Replies View Related

AutoCAD Civil 3D :: Exchange Content Migration To Social Networks

Jul 27, 2012

I would like to express my dismay at hearing that exchange content is being migrated to "social networks". While I have no problem with this, per se, this will restrict access for the majority of users who cannot access Twitter, Facebook and Youtube at work which is when they are likely to need the content most.

As a matter of interest how many of you have access to these networks at work (from your laptop/PC not via smartphones, tablet devices etc).

IDSP Premium 2014 (mainly Civil 3D 2014 UKIE SP1 & Infraworks with some limited 3ds Max Design)
Win 7 Pro x64, 256Gb SSD, 300Gb 15,000 rpm HDD
16Gb Ram Intel Xeon CPU E5-1607 0 @ 3.00GHz (4 CPUs), ~3.0GHz
NVIDIA Quadro 4000, Dual 27" Monitor, Dell T3600

View 6 Replies View Related

AutoCAD Civil 3D :: Designing Pipe Networks While Finished Surface Still In Progress

Apr 2, 2012

Another collaboration question so you have a compressed design program and want the drainage to be designed while the finshed surface is yet to be completed.

View 5 Replies View Related

AutoCAD Civil 3D :: 2013 Pipe Networks Reference Surface Amended

Sep 9, 2013

I have designed a pipe network in Civil 3D 2013, first I created a rule set for both structures and pipes, then I created a parts list, next I built my network.

Where more than two pipes connected to one structure, I found 'applyrules' couldn't align everything appropriately, so I had to manually amend the levels in 3D to ensure the pipes connected correctly (soffit to soffit / top invert to top invert).

My problem is that after doing all this, the surface model has been amended! I have changed the reference surface in the network properties and in the vista. The rim height of my structures seems to have been adjusted in the most part but my pipes have not.

In areas where the surface has gone down, my minimum cover is violated. Is there a way to move the pipes back down to minimum cover, without using 'applyrules', as using that command would change the gradients to the minimum, some gradients have changed during my manual adjustments.
 
Furthermore, where the surface model has reduced in level significantly, my pipes are now above the surface and the manhole has stayed there too.

View 1 Replies View Related

AutoCAD Civil 3D :: Wall Thicknesses For Pipes In Parts Lists In Pipe Networks

Dec 24, 2013

How Autodesk came up with the wall thicknesses for pipes in their parts lists under pipe networks in Civil 3D? I found that for DIP the wall thicknesses for pipes was way greater than anything commercially available; and that for PVC the wall thicknesses were way thinner than what's commercially available.

Are most client's modifying these lists to conform to pipe specifications or ignoring these discrepancies?

View 1 Replies View Related

AutoCAD Civil 3D :: Combine Pipe Networks From Separate Files Into A Single File

Jul 16, 2013

I need a way for 2 users to work on a pipe network at the same time.  I was thinking about creating Data Shortcuts, but I’m looking for a better way to accomplish this.  For example, can I export a pipe network created by another user into a master file? (which contains all my networks consolidated together).   I want to work on one part of the network while another user works on another part of the network then combine into a single file so that I reference everything into our P&P sheets.

View 5 Replies View Related

AutoCAD Civil 3D :: 2012 Edit Pipe Networks Set Inverts At Inside Edge Of SDMH

Apr 26, 2013

I created a pipe network from a object (alignment wLpolyline) I want to set my inverts at the inside edge

of my SDMH not the center. I go into Edit Pipe Networks then the vista (table). I don't see a option to do that.

Is there a setting in the SDMH structure style or somewhere else?

As an example I come in at 6250.0 at inside a 48" MH and go out at 6251.0 at other side of MH.

I wanted to use a catch basin that shows the depressed curb & lip like the one in the Pipe Network Video

but it not in my parts Library even when I create a full parts list it still isn't there. Is ther a way to go on line and download part structures?

View 2 Replies View Related

Photoshop :: Masking Part Of A Blending Option (Drop Shadow)

Jan 8, 2005

Im trying to make a transparent image that has a drop shadow only onto a menu. Its hard to explain but heres a picture. is there anyway of masking all of the drop shadow that doesn't land on the menu?

View 8 Replies View Related

Photoshop :: Masking Multiple Layers In Different Groups With A Single Mask?

Apr 9, 2012

author one mask that effects multiple layers without using a group mask?  Unfortunately I can't throw all the layers in a group and use a group mask in this case since the layers that I want to share the mask must be in different group folders.  (I am using actions to export the results of each group to the different flattened files.)  So I have similar but not identical layers in separate groups that I would like to share one authored mask.  I also can't use smart objects because the layers are not identical. 

View 2 Replies View Related

AutoCAD Inventor :: Part File With Multiple Instances Of Multiple Solids?

Apr 18, 2013

I'm designing a part that in Autodesk Inventor 2013 that is constructed from several layers laminated together. I have 4 layers:

F (front)

M1 (middle, variation one)

M2 (middle, variation two)

B (back)

The final solid will lhave 17 layers laid out like this:

F | M1 | M2 | M1 | M2 | M1 | M2 ... | B

I currently have a part file containing

F | M1 | M2

What's the best way to create this solid if I want to a) keep all instances of M1 and M2 in sync, and b) make it easy to work on all 4 layers. Do I have to export F, M1, M2, and B as individual parts and import them into an assembly or can I keep them in one part file? I really like the ability to be able to work on all the solids at the same time because they're visually dependant on each other.

View 4 Replies View Related

AutoCAD Civil 3D :: Pressure Fitting Parts Masking?

May 30, 2013

Longtime C3D user, new to pressure pipes though. It seems one cannot mask pressure fittings in plan view. Is that correct?

Using C3D 2014

View 2 Replies View Related

AutoCAD Civil 3D :: Get Volume Elevation Table Masking To Work?

Dec 12, 2007

How to get the Volume Elevation Table masking to work?

I can only get the Title to work correctly - everything else plots as a black blob if Fill is on. With Fill off - there is no mask.

View 1 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved