AutoCAD 2013 :: How To Turn Off Warning Message When Loading A Script
Apr 15, 2013
We use scripts a fair bit in acadLT & from the Desktop icon. The 2014 behavior has changed in that it displays a warning (screengrab attached) before allowing the script to load.
This is going to be a pain for users. I can't see a way to add a folder as a trusted source in LT.
I am doing a lot of saving new files over old ones. I am sick of the warning message that pops up having a default answer of 'NO' when I go to replace the files. Is there a way to change the default to 'YES' , or get rid of the message altogether?
We are trying to run an automated process on incoming AutoCAD drawings. However, the process stops if a drawing has AEC object references, because the warning dialog opens (and the program does not deal with it). Is there a programmatic way to disable the AEC warning dialog for opening? Similar to turning off the Proxy warning? Perhaps a Registry setting?
Immediately after closing AutoCAD Architecture 2012 or AutoCAD MEP 2012 a yellow warning triangle with a black exclamation point displays. This happens every time AutoCAD is closed. However it is isolated to a few systems all of which were installed using the same deployment as the other systems that do not display this warning. AutoCAD performs as expected but displays this warning when closed.
I created a Custom Coordinate using a predefined coordinate (Meter to Feet). Everything is ok except when I restarted Map3D, I get a warning message and I am not sure what I did or did not do to cause it.
I was using 2009 Architecture. I kept getting a message in the command line: "WARNING: Xdata tag 100 is missing" like hundred to 1000 times and while its scrolling through this same message in the command line I can not do anything but wait for it to finish. Not sure if a recent windows update has anything to do with it. I am using XP Pro. I have a Dell with 3GB of ram and a Radeon X300/X550/X1050 video card and am running dual monitors. I have an upgrade to Archtiecture 2010 so rather than reinstall 2009 I installed 2010. Unfortunately, same problem. In 2009 I seem to remember that it was more random. In 2010, it pops up when I do an xref reload.
When I enter a Run File Name in the "Create Tube & Pipe Run dialog box I get the message "The path is too long. Try a shorter name." The name I entered is "Kappa 55 Suction Line", I also tried the Run File Name of "1" as a test and get the same warning message "The path is too long. Try a shorter name."
I have VSx5, and I've gotten an error message or two,telling me that my GPU unit is not up the task. This happens when I'm running a few of the more demanding things, it came up when I was using the Vitascene filter and also in Boris Graffiti. Does this mean I should get a better graphics card? I have an ASUS i5 laptop, and as far as I can tell my GPU card is the Intel HD graphics 3000.
I have lists of Documents I am altering and saving automatically in a loop, The problem is that if the file needs to be migrated you get a dialog box in your face for every file in the list. How can I temporarally turn the dialog off?
I am using Photoshop CS6 and if I have nested layer groups whose depth is greater than 5 I get the following error message. "This document contains nested layer groups that may change in appearance if opened in applications older than Photoshop CS6".
I can click on "don't show this message again" before pressing ok, but can i disable it from showing somewhere in the application settings? I want to enable it sometimes and sometimes not.
- The "Reset All Warning Dialogs" button from Edit - Preferences - General is not very usefull because I want to keep other messages' settings, only this one should be affected.
Getting a lot of message pop ups about not accessible dst file. In conjunction with this is constant slow down if the sheetset is open with the blue cursor wheel constantly thinking. If the sheet set is closed, this immediately fixes this.
Ruled out network problems as 2012 works fine. I believe this to be isloated to 2013.
Sometimes when loading some DWGs, I get this Warning (plaese see the French JPG capture) saying that maybe I could need : Korean, Japan, Chine, etc language module !
I would like to bypass this Warning automatically because I open these DWGs with a Script to do some automatic actions and I resave them ...
At the Warning question : Do you want to open --> YES
I don't think that I can control this warning (--> Yes) through a special System Variable !?
Publish works as expected in foreground, uses proper page setup plot style and color table an dthe results are black on white.But when using PUBLISH in background it shows an error for each ""WARNING: Incompatible or missing plot style"" and the created PDF's are in color instead of balck and white.
We have loaded copies of AutoCAD Architecture 2013 on several workstations. We had tried brining over older profiles (from 2008)- which did not work, so made up new ones. ANYTIME we go into the profile settings to load a different profile beyond the default, AutoCAD Architecture (US Imperial), eventually while working the program will crash. We've wiped out installations of the program, registry and all, and re-installed without brining over any prior data. Same issue.
Even when using a seperate "default" profile us as (Global) or (Metric)- same issues. The problem with staying/modifying the workspace for the US Imperial is it will not load the complete menus with the MENULOAD command (only loads EXPRESS). If we work within the (US Imperial), no crashing, but again, the menus are not available within that profile for some reason, so that is not an acceptable solution.
I just purchased Elements 11 and tried to update the software and I get a message to turn off auto analyzer . what this is and where do I find it to turn it off...
How do you turn off the 'image is offline or missing' dialog when no drives are hooked with the source files. I'm on LR3, and I don't remember this being an issue with LR2. Doing a client presentation with my MBP and the files are indeed offline. I usually my client selection process from the grid and loupe views, but I'm getting this message, pretty large across the top of the image. I don't remember this being an issue before, so either it wasn't there at all, or the text was smaller.
I have loaded autocad 2013 on several workstations. On one machine, I seem to be having trouble with the .pgp file not loading. Ordinarily when typing in "O", i get offset but for some reason, it changes my cursor to orbit and asks to "select an object".
This is only happening on one machine. Other commands work but customized ones do not.
I need to load 11 xref in my project but seems like in autocad 2013 more than 10 xref is not allowed, it keeps on rejecting the 11th reference without prompting any error.
I have tried to save the drawings in lower version and do the same procedure and it works, i therefore conclude that the issue is with 2013 version.
saving in lower version everytime we receive new xref is really time consuming and painful for hundred of drawings.
I recently downloaded the student version of Inventor Professional 2013 (64-bit). I made some parts and ran some stress analysis simulations on the parts. I restarted Inventor after running a simulation and upon the reopen, none of the add-ins on the Environments tab were there and the Add-Ins manager does not open. I tried uninstalling and reinstalling the entire program, even tried installing different model years of Inventor; none of the versions load the add-ins and the add-in manager fails to load.
I have been using AutoCAD Architecture 2013 imperial for weeks. Then the other day I went to use it again and the program would not finish loading. The metric version that comes with the program does open.
I keep getting the error message "For the Photoshop UI to display correctly, open System Preferences, click Appearance, and turn off text smoothing for font sizes 8 and smaller." I go into preferences and into general but there is no setting to turn off text smoothing for a specific font. I'm in osx mavericks and all it says is "use lsd font smoothing when available" and when I uncheck it, the error message in photoshop still pops up.
While loading any dwg file in autocad 2013, the preview is wrongly showing after select some shortcut file in same dwg folder. and its not back to the dwg preview. its only happen in window 7 machines only.
working with 2014 acad and i have made myself a partial CUI. it is really only one extra tab on the ribbon with a few of the standard panels i use in one place. nothing to out there. so here is a step by step of what i did to get this cui file.
entered comannd CUI in command prompt.
went to "Transfer" tab in the CUI dialog box
on the left panel it is "Main Customisation File (acad.cuix)"
on the right panel i created a new CUI file.
then right clicked the "Ribbons" path and created new "Josh's Tab"
then transfered the panels across i wanted
then saved the cui as "Josh's CUI.cuix"
then loaded the .cuix file via the "CUILOAD" command
at first nothing at all happened, so i unloaded and reloaded it. then closed and opened acad again. still nothing
so i loaded it and unloaded it a few times again. so i went back to "CUI" and had a look at my partial and it hadn't saved anything.
so i created a new tab again "Josh's Tab"
transfered the panels again and saved the file then loaded and reloaded the .cuix
when i loaded it acad "blinked" while it reloaded all the CUIs and my tab was there but no panels. i had another look at the CUI and the panels are there but not showing in the ribbon.
i have done this from 2009-2012/13 (can't remember which i was last using) and never had a problem. i have been away from Acad for the last 16months though so i figure i have just forgotten one simple step somewhere. I have the current SP installed also.
Product design suite 2014 running on a Toshiba Qosmio X870-70
Initially we got an error message stating: "error: no function definition: VLAX-USER-PRODUCT-KEY".We did some trouble shooting ourselves with information obtained via several web searches, involving the following:
1) Adding .fas files from the Express directory to the appload.
2) Reloading the acetmain.cuix via menuload (had to unload it first, since it was apparently already loaded)
3) Removing and re-adding Express Tools via Programs & Features (Add/Remove programs)
4) Reinstalling AutoCAD 2014
5) Running (vl-load-com) from the command line (no effect)
6) Running expressmenu and expresstools from the commandline (says it's successful).
then we are now getting "error: no function definition: VLAX-MACHINE-PRODUCT-KEY"..The registry keys appear to be OK, and I am seriously at the end of my tether. I have pretty much tried everything I could find to no avail.
So my other designer is having issues getting his ACAD to open directly from a DWG file. He can open just fine using hydracad, or autocad, or acad mechanical, and open the file once inside. The problem only arises while opening straight from the DWG file on our server (or his hard drive itself, doesnt matter the location). Any DWG file for that matter. Myself and another designer are able to open them all just fine, and have no issues. We are all running with the exact same settings of startup (1), and all have the same computer specs.
Intel(R) Xeon(R) CPU E5502 @ 1.87GHz 1.86GHz (2 Processors) 8gig ram 64 bit operating system. Nvidia Quadro NVS 290 and a couple 250 gig Hard drives.
We tried running a repair and it didn't do anything. Not sure what the issue could be. I tried performing quite a few of them for him (even though none of the titles indicated they were having troubles opening just with DWGs, as most were having freezes on the splash screen just opening the .exe).