AutoCAD Map 3D :: DGN Reference Alignment

Mar 8, 2011

I really like the option to reference a .dgn into Civil3d but I have noticed an alignment issue.  If I use Map Import and bring in a .dgn, (without changing any import defaults) then reference the same file it never ends up exactly aligned with the original data.  It's almost like a coordinate surface conversion but it's only off +/-29'.  I set-up my coordinates units under settings in my toolspace and get the same results. 

I attached a file for an example.

View 1 Replies


ADVERTISEMENT

AutoCAD Civil 3D :: Structure Reference Alignment Not Holding In Data Reference

Nov 28, 2012

I have structures and alignments data referenced.  If I assign the structures ref alignments in the dwg with the data refs for labeling, the next time I open the dwg the ref alignments are set back to none, causing the labels to be ?

It seems like this worked in the past?

View 1 Replies View Related

AutoCAD Civil 3D :: Data Reference Alignment Stationing Differs From Original Alignment

May 3, 2012

I using a data reference/shortcut to properly label an alignment in paperspace. However when I reference the alignment in and apply the labels the aren't the same as the original alignment that I am referencing. Is there a setting where I am supposed to apply a new beginning station.

Also it seems as though the stationing(distance) isn't even matching up 1:1 with the original drawing. For example in the original base drawing my alignment starts at 10+00 with the next PI at 14+76.98, but the stationing on the reference alignment starts at 0+83.33 with the very same PI being labeled as 1+23.08. So the very same distance is 476.98' in the real design and the drawing it's being referenced in, but the stationing of the referenced alignment shows it as 39.75 Units.

I've attached a screen of the beginning of the alignment.

Civil 3D 2012
Windows 7 Service Pack 1
Intel Core i7-2600 CPU
16GB RAM

View 5 Replies View Related

AutoCAD Civil 3D :: Alignment Reference Text

May 31, 2012

I created an alignment style specifically to label typical sections.  My label style includes a triangular symbol (XSM) and alignment reference text (XSL) attached to the symbol.  The label attaches correctly to the alignment geometry points (POB and POE) but the alignment reference text which should call the alignment name instead shows three question marks.  At no point in the process am I prompted to select an alignment which is as expected.  The label should automatically populate with the alignment name.  The label properties indicate the appropriate alignment as the reference object. 

Civil 3D 2012 (64)
Windows 7 Pro (64) SP1, 16 GB
AMD Radeon HD 6900

View 2 Replies View Related

AutoCAD Civil 3D :: Assign Reference Alignment To Pipe Network?

Mar 2, 2013

is there any quick way to assign reference aligment to pipe network parts?

I use practise to create one pipe network and afterwards i expand my pipenetwork by editing with lots of aligments (create aligment from network part function i use). Bur there occur a problem in my profile view, when i want to represent station value of aligment and there is now reference aligment in pipe part.

View 1 Replies View Related

AutoCAD Civil 3D :: Alignment Label With Reference Text And Expressions

Oct 30, 2012

I'm trying to create an alignment label to display profile elevations at regular stations.  Two questions:

1.  I use an expression to set the text height.  When I add a regular text component in the label this works fine, but when I add reference text I can't seem to use the expression as text height.
2. I want to use an expression to 'Truncate' the elevation, so that 178.35m displays as 78.35.  I can't find a way to create an expression to do this (within the Alignment station labels).

View 6 Replies View Related

AutoCAD Civil 3D :: Could Not Establish Reference To Parent Horizontal Alignment

Aug 15, 2012

Maybe my workflow is flawed but I thought I had done this before:

Drawing A has alignments and profile views

Drawing B has DS of alignments from A

User A is working on annotating profile views in drawing A. User B is working on design profiles in Drawing B, adds DS of design profile and everything looks correct in the DS node. But when we try to DS in the design profiles we get the message in the title.

Civil 3D 2012 & 2013
HP Z210 Workstation
Intel Xeon CPU E31240 @ 3.30 Hz
12 GB Ram

Note: Its all Resistentialism, so keep calm and carry on

64 Bit Win7 OS

View 9 Replies View Related

AutoCAD Civil 3D :: Change Alignment Reference In Profile View?

Sep 18, 2012

I have a profile that references an alignment, I want to change the alignment that the profile view references, can this be done?

View 1 Replies View Related

AutoCAD Civil 3D :: Change Pipe Network Reference Alignment Or Surface

Dec 14, 2009

I want to change the reference surface for a pipe network with existing pipes and structures. however the changes will only affect new objects, I have to manually change the others one by one. Even with the vista open I can select multiple structures, but when I click in the reference surface column of one of the selected structures, all the others are deselected.

View 6 Replies View Related

AutoCAD Civil 3D :: Grip Edit Alignment Changes Reference Point Location

Aug 26, 2013

I know this.  I am aware.  This is why I avoid changing the reference point as much as possible if I have profile views or anything else dependent on my alignment.  I also have no problem with this dialog giving me a useful reminder.

My problem is this: if I want to make my alignment longer, and I grab the grip at the end of it and drag it to a new location, the reference point moves too!  Who in their right mind would want the reference point to move when adjusting the end? Personally  I wouldn't want C3D to ever move my reference point automatically.  I can have some sympathy with moving it if I am grip-editing the start of the alignment, or the tangent on which the reference point resides.  But I'm editing at the end of the alignment, on a different tangent.  Why would you move my reference point and make me have to go back and reset it to where it was?  How dare you throw your warning message at me for moving the reference point back to where it should be when you secretly moved it to a wrong location with no warning whatsoever?

View 1 Replies View Related

AutoCAD Civil 3D :: How To Create Expression In Structure Reference Alignment Profile Elevation

Aug 3, 2013

I am create the stron network. I want structure profile elevation. How to create expression in  structure reference alignment profile elevation.

View 9 Replies View Related

AutoCAD Civil 3D :: Print Doesn't Match Preview Alignment Data Reference

Jul 12, 2013

I have a sheet that has several alignments data referenced and labels applied. Recently some of the alignments changed (slightly extended), I checked the sheet and all of the labels have auto updated. Everything looks good. A Print Preview looks good.

When create the print (to pdf), the alignments that changed and all the labels do not show up. Nothing changed with layers, styles, etc. I tried Synchronize and Refresh from Prospector. I can create another Data Ref but don't want to go thru all the labeling again.

Preview and pdf attached.

C3D 2012
C3D 2012 sp1
W7Pro 64bit
HP Z400 Workstation
16 GB RAM
Intel Xeon CPU W3565@3.20GHz
NVIDIA Quadro 4000

View 2 Replies View Related

AutoCAD Civil 3D :: Synchronizing Data Shortcuts Breaks Reference To Alignment In Profile Labels

Sep 6, 2013

I have some storm sewer alignments that I've put into profiles in C3D 2011.  The pipe network that I used to create the alignments from is a reference created from a data shortcut.   I've created profiles of these storm sewer alignments, and the station labels for the storm structures are displayed at question marks until I go into the structure properties for each structure and link it to the correct alignment.  

The problem is that whenever I synchronize my data shortcuts because someone has updated something, all of the links in each structure to the alignments disappears and I am back to? for my stations in the profiles and I have to go go fix it again. how to keep this from breaking?

I do see this recent message [URL]  that appears to be a similar problem, but it was said in that thread that this problem was introduced with C3D 2012, but I am using C3D 2011.....

View 4 Replies View Related

AutoCad :: One Reference File To Control Multiple Reference Layer Settings

Jun 27, 2012

I'm working on a large infrastructure project with numerous of drawings. On quite a few layout drawings I need to have the same base set of references, however I need to change the layer settings (colors, lineweight etc.). This cannot be done in the base reference itself as it is used by others. As the layouts I work with includes other references as well, it is time consuming to filter and change layer settings on each base reference.

My concept is to have a master reference file to manage all layer settings and add/remove base references. When the master reference is referenced into the layout, all layer settings on the base references should stay as set in the master reference. In this way I can easily control all base references with one file and make sure all changes will be the same for all the layouts.

New illustration of concept:

View 9 Replies View Related

AutoCAD Civil 3D :: Reference Surface (x) Not Found In Reference Drawing

Jul 28, 2011

I am getting this error in my production drawings.

My setup is as follows:

- EG.dwg has my existing surface in it. I create a data reference to use it in other drawings.

- Level One.dwg has the EG surface data referenced in, and I use this to create alignments, profiles, and finish surface. All of these are turned in to data references.

- Storm Sanitary.dwg has my pipe designs. I data reference in the two surfaces, profiles, and alignments, and create pipe networks. I create references for these networks.

- Plan Profile.dwg is the production sheet I'm getting this error from. Every one of my civil objects is data referenced in to this drawing. Everything is inserted correctly, the pipes show correct FG surface elevations for their rims, etc.

BUT when I open this drawing, I get this error. I assume it's because my FG surface is not directly in the storm sanitary.dwg.

How do I get rid of this error, without combining drawings, or promoting the surface to one or more drawings? Isn't this exactly what data references is made for?

View 1 Replies View Related

AutoCAD Civil 3D :: Changing Alignment Direction Where Feature Line And Alignment Coincide?

May 28, 2012

i've made a serpantine curve that starts from one line of alignment and end on the other line.

i wanted to know how can c change alignment direction when these two feature line and alignment meet each other in order to change the alignment path?

View 3 Replies View Related

AutoCAD Civil 3D :: Change Alignment Label Style Set After Alignment Has Been Created?

Jul 18, 2013

Using Civil 3d2012, Is it possible to change the alignment label style set after the alignment has been created?  For example, for an alignment that was created with alignment label set X - change the label set to alignment label set Y?  It seems like this should be pretty easy, I must be missing something obvious. 

View 2 Replies View Related

AutoCAD Civil 3D :: Alignment Style Vs Alignment Labels - PI Treated Differently?

Apr 6, 2013

I have a question on Alignment PI's. (Point of Inflection/Intersection)I have an alignment where some PI's have curves, others are merely hard bends.

Is there a way to automatically label the PI's even if they have an associated curve? (I'd like PI, PC and PT)Alternatively, can I only show markers at PI's without curves?

View 9 Replies View Related

AutoCAD Civil 3D :: Alignment Entities Not Showing Up In Alignment Grid View

May 20, 2013

I'm trying to edit some existing alignments. When I create new entities, they do not show up in the alignment grid view. Why is this?

Windows 7 x 64 bit
NVidia Quadro 2000 Dual Monitor
6.00 GB RAM
Intel Xeon W3550 @ 3.07 GHz
Civil 3D 2013 SP 2, Civil 3D 2012 SP2, Civil 3D 2011 V3, Civil 3D 2010 V3

View 5 Replies View Related

AutoCAD Civil 3D :: Launching Alignment Grid View / Alignment Entities

Aug 11, 2013

Launching alignment grid view/alignment entities,

I’m wondering if there is a way to launch alignment grid view/alignment entities (attached) without the need to first launching “alignment”? This dialogue box is quite essential in editing the values of radius, degree of curvature and deflection angle for the selected curve.

View 2 Replies View Related

AutoCAD Civil 3D :: Alignment Begin Station Inherited From Another Alignment

Aug 8, 2012

Can I inherit the station from one alignment as the begin station for another alignment?

For example. Alignment 1 is 1000 ft long and starts at sta 0+00.

At sta 8+01, Alignment 2 begins and goes off in another direction.

I manually enter 8+01 for begin station Alignment 2. Life is good. Still in the design stage, and customer needs to modify Alignment 1 to avoid something. Now Alignment 2 intersects Alignment 1 at sta 8+15, but same N/E coordinates.

I manually enter 8+15 for begin station Alignment 2.

It would be better if Alignment 2 could inherit the begin station based on the new stationing from Alignment 1.

View 7 Replies View Related

AutoCad :: X-reference Causing Currently In Use?

Jan 11, 2013

I'm currently working on a job in a team where we'll be working on different drawings, yet have the other drawings x-referenced into our drawings to keep up with updated files. We've had no issues with this for the few months we've been doing this, until overnight one night this week it seemed everything changed.

I'm currently updating our elevations while my partner is updating the plans. I have those plans x-referenced into my elevation drawings. The issue that we've run into is simply that any time I have my elevations or any drawing open that contains an x-reference, the file that is being referenced won't open without stating "[that file] is currently in use by [other user]. Would you like to open the file read-only?"

I've seen this alert before and it's understandable when dealing with the actual file (one person opens a file another already has open), but I've never before had this alert stem from the file in question being an xref. I closed my elevations and then opened the plans with no problem...no alert stating they were in use by someone else.

We're using AutoCAD Architecture 2013.

View 2 Replies View Related

AutoCAD .NET :: How To Get All Block Reference In A Drawing

Mar 29, 2013

I need to get list of all block reference in  a drawing without iterating through all entities in the drawing.

View 7 Replies View Related

AutoCAD Inventor :: Reference Parts In BOM

Mar 20, 2012

All of the patterned parts in my assembly show up as reference parts in the BOM I have I have opened the base part for the pattern and made sure its BOM is set to normal. When I change the BOM setting in the assembly it automatically changes to reference.

View 2 Replies View Related

AutoCAD VB :: Add Table With External Reference

Mar 24, 2011

I need to add table in acad as an external reference via ms excel.

View 2 Replies View Related

AutoCAD VB :: How To Access Point Through Reference Or ID

Feb 12, 2013

How can I store reference to AcadPoint for later use? I am inserting hunderds of point to ModelSpace. In each loop I have reference to created point. But how to store this reference for later use in some array, collection...? The Colletion.Add(objPoint) does not work.

Set objPoint = ThisDrawing.ModelSpace.AddPoint(point)

View 9 Replies View Related

AutoCAD Inventor :: Reference In 2D Drawings?

Jun 5, 2013

know if we could put for example the Building of our Assembly in some 2D drawings as a "Reference" object and as a non reference object in other 2D drawings?

In some 2D drawings we don't need the whole building, and just with the references is enough, but in some other views, we need to see the building so we can represent the real obstacles we have or to show how the custumer should do the pipe implantation

View 5 Replies View Related

AutoCAD Inventor :: Change Reference IPT From IDW?

Mar 30, 2005

I have Sample.ipt, SampleRev.ipt and Sample.idw. (Sample.ipt and SampleRev.ipt are the same configuration part with some different parameter value) Sample .idw is a drawing of Sample.ipt. How can I use code to change Sample.idw to be a drawing of SampleRev.ipt.

View 9 Replies View Related

AutoCAD LT :: Insert External Reference

Jan 31, 2013

I am using AutoCAD LT 2013. I always start my drawings at a common point 0,0,0. When I attach an external reference, I want the insertion point to be 0,0,0 so that my drawings overlap each other. However, when I attach, the drawing is 596'-10", 345'-11 1/4" every time! Am I missing a setting or extra step?

View 1 Replies View Related

AutoCAD Inventor :: Different BOM Reference Structure In Same IAM Possible?

Jul 26, 2012

Let's say i want to draw a bike. In the 2D IDW of the wheel I want to see the frame as a reference. So, in the .iam of the wheel the frame subassembly is inserted and checked as reference. Also, a new level of detail is created that surpressed the frame.This level of detail is used in the overall assembly of the bike.

So, I end up with several subassembly's that contain other subassembly's just to reference them in the IDW. It would be better to have just one master assembly and create several IDW's from that assembly with different LOD and reference settings.

Inventor 2012 - 64 bit - build190 - Windows 7

View 4 Replies View Related

AutoCad :: Rotate With Reference Option

Jan 16, 2014

I frequently use ROTATE with the reference option, which is a very useful tool. Just wanted to do this again, but instead of the usual 4 point picking process I am asked to "Specify the reference angle" after choosing "reference". Never came across this before.

Did I unintended change some settings? It´s the first time I use ROTATE after reinstalling my AutoCAD a few days ago.

View 4 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved