AutoCAD Inventor :: Applying Underscore To Dimension Text
Aug 22, 2012
I have a set of dimensions on my drawings however where the dimension is displaying as 6mm in a vertical plane this is quite difficult to distinguish as it could be misread as 9mm. Is there a way to add an underscore mark on the 6 so no mistake can be made as to it being a 6 and not a 9 ?
View 9 Replies
ADVERTISEMENT
Sep 13, 2013
I am having problems with changing the height of the dimension text. I have tried going into the style editor and changing the text height in there and then saving it. The number for the height that I changed stays saved however the actual text height on the drawing does not, not even after I tell it to update.
View 3 Replies
View Related
Sep 21, 2011
How do you add text before a dimension in the idw environment? For example, I have a dimension that shows 40".... I want to add text before it to say something like.... " 8 Spaces at 5" = 40" ".... The 40 would be the default dimension value, everything else I want to add to the dimension... I have added tons of text information behind default dimension values, this is the first time I need to add the text before the value and cannot figure out how to get it to work...
Example:
oLinDim(3).Text.FormattedText = "8" &" SPC'S AT" & vbCrLf & "5 = "
this adds text after the default value of 40...
View 1 Replies
View Related
Nov 8, 2012
I have a dimensioning problem. I have dimensions that I cannot modify as I normally do. I do not know what setting is stopping me but here is what it is doing. I add a dimension to a part. I then edit it to add 2X in front if it. It will then put it on top of the dimension. If I put it behind the text, it then goes beneath the dimension. There is no way to add text and it would actually appear on the same line as the dimension.
View 3 Replies
View Related
Jan 30, 2009
I have a user that wants to be able to either link dimensions to other dimensions, such as a ref dim to a live dimension or while inserting text in a note on the drawing to be able to list a dimension within that text string to a dimension of the part so as the part updates, the dimension in the text sting updates.
View 9 Replies
View Related
Nov 5, 2013
I am currently wanting to have my horizontal dimensions above the dim line and the postfix text below.
I can set this in inventor but when i do a save as autocad.dwg (2007) the postfix text either ends up above the line or puts a double space below the line.
View 6 Replies
View Related
Sep 3, 2012
Is there any way to change the size of dimension text in sketch? My students cannot see the dimension when I demonstrate the sketch.
View 9 Replies
View Related
Aug 14, 2013
See the attached image. I'd like to rotate the text of the dimension shown to be horizontal relative to the page.
The best I've found in searching for a solution is here (on the bottom):
[URL].....
however, following those instructions actually changes the dimension value to the distance projected in the plane of the sheet.
View 4 Replies
View Related
Nov 25, 2011
I have been working on some spec sheets and, ideally, would like the text size larger to improve readability. When creating text, changing the size is as easy as editing the text and changing the size. With a dimension, however, that method doesn't work. Is there an easy way to change a dimension's text size without having to make a change in the styles??
View 2 Replies
View Related
Mar 23, 2012
I have a problem with the display of the text string when creating a dimension, been through all the options within the styles manager however no option to display the text to the right of the dim line, it always defaults text to inside the dim line, where the option to toggle alignment of text on a vertical dimension line is ?
Autodesk Inventor Professional 2013 SP2 64-Bit Edition
Windows 7 HP Z400, Intel Xeon W3550 3.07GHz
12.0GB RAM, ATI FirePro V4800 (FireGL)
View 3 Replies
View Related
Apr 10, 2013
I'm aware this has been raised before, see [URL] however this was way back in 2004. Surely there must be a solution by now!
View 1 Replies
View Related
Jun 2, 2011
I'm trying to get the dimension text that I pull out to the side closer to the actual dimension marks. The 2 1/2" and 2" shown have a minimum distance they can get toward their dimensions. I would like it to be about half of what it is, but so far I haven't been able to find the property that changes that.
View 3 Replies
View Related
Feb 29, 2012
I am having trouble changing the dimension text size of any 2d or 3d sketch..
the default has changed for some reason (i might have accidentally changed it while looking for something the other day) but i need to know how to change it back.. I can't do anything without a dimension getting in the way!
View 2 Replies
View Related
Feb 13, 2013
How do you change the dimension text size in an .idw 2D drawing? The dimension text and arrowhead size is too small and I would like to make it sligthly larger.
View 3 Replies
View Related
Jul 9, 2013
How to rotate ordinate dimension text in Inventor 2014? Currently the dimensions are horizontal but I would like them to line up with the dimension lines (top and bottom dimensions are vertical)
View 1 Replies
View Related
Jun 8, 2010
I would like to overide the dimension value with a letter - Dim "A" etc. but the overide box will not accept an alphabetical input. At present, the only way I can get around this is by sketching the basic dimension box separately.
View 9 Replies
View Related
Jul 2, 2013
How do i increase the dimension text height in my drawing.When i go thro the styles and standards editor and increase the text height all the text in my sheet border also increases.Surely there must be a way to isolate the dimension text from the sheet text.
View 2 Replies
View Related
Feb 21, 2013
Can i change the length of the dimension line 'extension' when my dimension text placement is beside the dimension line (see attached image)?dim line length.jpg
View 6 Replies
View Related
Dec 29, 2010
every one now a day i am making isometric drawings so i m little bit confuse in that i am using dimension and change the oblige angle text of dimension so is it right way or not ????
View 9 Replies
View Related
Dec 13, 2011
I am trying to edit the placement of vertical text within a dimension line - I wish for the text to be outside the dimension line not inside.
View 4 Replies
View Related
Jul 29, 2011
When doing an angle dimension and trying to put text under the dimension line, the text types out straight which if long enough will extend over the dimension line. Other then creating text with arctext, is there no other way to get it curved? I am using AutoCAD 2010.
View 3 Replies
View Related
Nov 2, 2012
I was looking to change the fonts in a drawing for the Dimensions and Symbols that might have been inserted in the Dimension text entries.
This can be done manually bu editing the dimentions text after placemement, but I was ooking to set this as a default.. I cannot see where exactly this is controlled in the Styles Manager - I am only able to change the Dimension text font but the diameter symbol font is always on AIGDT.
I was therefore looking for an iLogicvb code that could do the trick, but I am not able to even change the dimension fonts... The code runs with no errors but nothing gets updated in the drawing...
Dim oDoc As DrawingDocument
oDoc = ThisApplication.ActiveDocument
Dim oSheet As Sheet
oSheet = oDoc.ActiveSheet
[Code]....
InventorVb.DocumentUpdate()
View 3 Replies
View Related
Apr 25, 2008
my normal dimension style has text above dmension line & I want to add 'typical' to it below dimension line.
I have done this lot of time in my previous job an year back. but I can't seem to remember what to type between dimension text & the word I want to add in edit text box, so that it appers below dimension line.
View 7 Replies
View Related
Oct 31, 2013
I have an animation using some interacitve SVG. I used the Edge Commons example (URL...) and it works well.But i have an issue regarding the text codage :I have "spaces" in the text of my layers in the SVG file, but the "spaces" are replaced with "underscore" in the animation.I guess it is a codage problem. Should I look in the SVG export option of Illustrator ? Should i code something in the html file?
View 2 Replies
View Related
May 28, 2013
I have one problem in ilogic "How to convert the normal dimension to driven dimension through ilogic"
View 4 Replies
View Related
Feb 23, 2013
how to make a radius dimension a diameter dimension? I have Inventor Profession 2013.
View 1 Replies
View Related
Jun 27, 2011
Is there a way to override a dimension and have it shown as a GD&T Basic dimension. I can override a dimension with the text option but not with a box around the letter. It sounds strange to do this but the letter represents a dimension in a chart format that are Basic dimensions.
View 9 Replies
View Related
Jan 27, 2012
Is there a way to make the linear dimension a diameter dimension?
View 9 Replies
View Related
Dec 17, 2013
I think I may have made a big error. While adding text and applying (experimenting) various "Effects" with the text, I used the garbage can icon to remove the "Effect", thinking it is going to remove the 'Effect" from the text, until I realized I had to remove the "Effect" with the edit button, not the garbage can. Have I now permanently removed the various "Effects" permanently or just off the screen? How do I regain them back onto the menu column? How many "Effects" should be visible in order to have the complete set? This was my first experiment with the lettering effects and hope I haven't lost them forever.
View 3 Replies
View Related
May 30, 2013
is it possible to have a dimension style setup that shows the dimension text inline with the dimension - without having to move it?I have been looking but cannot seem to do it - is it possible and I am just missing it?
View 1 Replies
View Related
Feb 13, 2012
(Again) The “leader” of the “dimension text” disappears when the text is moved! Why?
I’m wondering why the “leader” of the “dimension text” disappears when the text is moved.
How can I control this setting?
I need to show this “leader” all the time. Is that possible?
Please, have a look on the screenshots below (the file is attached).
View 1 Replies
View Related