AutoCAD Inventor :: Adding Physical Properties To STP Files?

May 10, 2012

I'm trying to add some material properties to a STP or IGES file I've received from a customer (in Inventor 2011). Is there any way to add a density for example, so I can obtain the mass of the model? I've tried doing it through the iProperties menu but it's not giving me a mass.

View 3 Replies


ADVERTISEMENT

AutoCAD Inventor :: Add New Materials To Physical Properties?

Jun 29, 2010

Two questions.

Is there a way to add new materials to physical properties?

Is there a cloud feature in Inventor for drawings, or is that something that can only be done in Autocad Mechanical and Mechanical Desktop?

View 5 Replies View Related

AutoCAD Inventor :: Physical / Mass Properties

Nov 8, 2011

I have recently made a bucket for chain (linked) and was looking to put the chain in the bucket for visual purposes and to see if the capacity of the bucket is correct. 

I can get the chain linked together, however when rotated round it passes through another piece of chain. 

Is there a way in inventor to tell a part/assembly of it’s physical/mass properties? I know you can make something mild steel and get weight etc, however if not constrained it still passes through as if it’s a ghost.

View 4 Replies View Related

AutoCAD Inventor :: Update Physical Properties From Drawing?

Aug 30, 2011

how I can update the physical properties for a part or assembly, from a drawing? My drawing template is showing the total weight for the current part/assembly, and I would love if Inventor could update this using iLogic, so I don't get the "N/A" value all the time. 

View 5 Replies View Related

AutoCAD Inventor :: Unable To Get Physical Properties Notation?

Oct 17, 2012

I have some issues with the notation for physical properties in the Inventor 2013 material editor.

Instead of displaying the obvious first choice metric SI notation kg/m^3 or something similar it display a self made? and awkward N*s^2/mm^4. I don't want this notation. How can I change to something more user friendly? It can be a bit hard to distinguish if a material have 0.00000000001 N*s^2/mm^4 or 0.0000000001 N*s^2/mm^4.

The document properties "units" folder have mm, seconds, degree and kilogram as default. 

View 6 Replies View Related

AutoCAD Inventor :: Material Browser Physical Properties In Metric - 2013pro

Aug 23, 2012

Al my projects, settings and templates use the Metric system.

When i open the material physical properties i see the Imperial System.

How can i change this ?

View 2 Replies View Related

AutoCAD Inventor :: Adding Physical Boundaries In Assemblies?

Apr 27, 2012

How do I set a constraint where 2 parts are attached to each other but do not phase through. For example if I have a door in a door frame, how do I add a constraint where the door can swing on it's hinges but get stopped by the door frame.

View 1 Replies View Related

AutoCAD Inventor :: Adding Different Material Properties To IPart?

Oct 28, 2013

I am having trouble changing a property of a solid body in one of my iparts. I have a concrete block which has been created as an ipart and 6 bars running through the concrete block. I am looking to change the material properties of the bars to Alloy Steel but i'm having trouble finding any option to do so. I have changed the material properties within the ipart table to concrete, i'm not sure if this is conflicting it.

View 3 Replies View Related

AutoCAD Inventor :: Physical Update Using ILogic?

Oct 12, 2011

Currently I am using I-logic and a form.  I have an assembly that I am pushing a volume from a part to the main assembly.  The volume updates in the part fine.  The issue is with the form is not updating when the file parameter updates.  If I exit the form and run the rule manually then the form updates.  how to update the form at the same time?

View 1 Replies View Related

AutoCAD Inventor :: 2013 Not Dumping Physical Memory

Dec 13, 2012

We recently moved from Inventor 2010 to 2013. Since then we have been having alot of lag problems. One major problem we have found that is giving us lag is our RAM usage. Inventor continually steals more and more ram until its starts to lag out. When I open a large assembly inventor goes from useing 1.2 GB to 4 GB of ram. When I close the assembly the RAM usage stays at 4 GB. If I open another assembly it just builds onto that and can go up to 6  GB before it starts lagging badly. Closing inventor dumps the physical memory.

System:
windows enterprise (no service pack) 7-64 bit  
intel(r) Xeon(r) CPU (2 processors)
9 GB RAM
Nvidia Quadro FX 4800 graphics card

View 8 Replies View Related

AutoCAD Inventor :: Duplicate Material Within Same Physical Assets?

Nov 2, 2013

When I duplicate the Material in the Material Browser all appearance and Physical properties are duplicated too.

So I must accept or assign the new unique names for appearance and Physical purposes of Material.

In my case I need, for example, the same Material with different appearance, for example knurled and regular.

I cannot save the new Material with existing Physical properties name and it makes unwanted copies like Steel(1), Steel(2) in Assets.

After I made a copy I can reassign the Physical properties back to existing but it takes a time of replacing assets and deleting unwanted copies.

Is it possible to make a copy within the same Physical Assets?

View 2 Replies View Related

AutoCAD Inventor :: Physical Property - Model - Mass Not Updating?

Oct 21, 2013

I have a .iam and .idw that i copied/designed from vault. The .idw has a sketched symbol that has a text box with the mass property. When update mass is applied the mass property in the text box does not. I ran into this once before and got it to work by re-inserting the symbol into the .idw but I can't get it to work. The orginal that was copied from works fine.

IV2013

Vault Collaboration 2013

View 3 Replies View Related

AutoCAD Inventor :: Change Description That Appears In Properties From Content Center Files?

Apr 4, 2012

Can I change the description that appears in the properties from content center files ? I want that appear Pa Allen or something like it, but the description is "Hexagon Socket Button Head Screw - Product grade A" from Content Center.

View 1 Replies View Related

AutoCAD Inventor :: Adding Content Center Files

Jan 31, 2013

I am using Inventor 2010, and just gone through the install program to add in content center files.   It installed 11 IDCL files and 1 IDZ file. I copied all these files to "C:Documents and Settingsdshupin1My DocumentsinventorContent Center FilesR2010".   Now, when I try to open something from my content center, I get a "Failed to open document" error, then another error that the file is not valid for placement.

View 6 Replies View Related

AutoCAD Inventor :: Actual Physical Texture (not Simulated Appearance Textures)

Oct 4, 2012

Inventor seems to do lots to allow for simulated appearance textures.   However, how does one use actual physical textures, e.g. for a plastic part?    I need one surface of the plastic part to be very rough/bumpy, another to be slightly rough/bumpy, and another to remain smooth/untouched.

Let me be forthright and say I have no background here in textures/plastics/molds etc.,

View 3 Replies View Related

AutoCAD Inventor :: Copy Properties Vs Model Properties In Drawings?

Oct 25, 2010

I want to set up my drawings so that the title block displays properties from the model.  I want to set this up so there will be drawing properties to extract into Vault.  So I want to know what other Inventor and Vault users are doing to get model properties into Inventor drawings:  Using model properties in the title block and nothing to extract in Vault or Copy model properties so Vault has data to extract.

I want to know what the best in class practice is?  What are others doing?  I do not want to use iLogic I was out of the box Inventor functionality.

View 4 Replies View Related

Revit :: Adding Parameters To Type Properties

Jun 11, 2012

I am trying to add LEED parameters to a floor type in the Type Properties.  That can be seen when I create a schedule?  I am unsure if this is possible but it is something we would like to incorporate in our models.

View 1 Replies View Related

AutoCAD .NET :: Adding Properties Palette To Custom Made Palette Set

Feb 2, 2012

Is it possible to add the Properties Palette to a custom made palette set in .NET? And how to do this?

View 3 Replies View Related

AutoCAD 2013 :: Physical Memory Limitation - 32 GB RAM

Jul 25, 2013

I'm working with point clouds. is there any physical memory limitation working with autocad. because i had 32gb ram but didn't see over 4 gb for usage by autocad. my computer's os is win7 x64.

View 3 Replies View Related

AutoCAD 2013 :: Adding Dwg Files Into ArcGIS

Aug 14, 2013

It used to be easy to add dwg files into ArcGIS when i used AutoCad 2012.  Now that i am using AutoCad 2014 my dwg files dont display in my ArcGIS.  How can i get the dwg files to display?

View 6 Replies View Related

AutoCAD Civil 3D :: Adding Very Large Points Files

Aug 19, 2012

I have some very large comma delimited ENZ files that I wish to create point clouds from. When I try to read points into a points cloud from this file I get "an error occurred in data processing" after a few seconds.

Since the error occurs early on, I was assuming C3D is getting hung up because of the first row of the file which contains an "x,y,z" header. The text files (around 270MB) are too large to open in wordpad, excel or similar, so I'm not aware of any way to edit or delete this line. To counter this I tried creating a new point file format using "x" as the comment tag (and setting all the other parameters as required. This "parsed" properly when testing on the file, however when I tried to import either as points or into a point cloud I still get the same error as above.

Is the file size/number of points too large for C3D or is it some other problem?

View 9 Replies View Related

AutoCAD Civil 3D :: Properties Palette Started Only Showing Current Properties For The Drawing

May 22, 2013

the properties palette started only showing the current properites for the drawing and not the properties  of the entity selected. what causes this i am using autocad civil 3d 2013.

View 9 Replies View Related

AutoCAD 2010 :: Properties And Quick Properties Not Displaying Information For Objects

Jul 10, 2012

When I select any object, my quick properties tab is blank and my properties tab doesn't register anything.  Also, I get an error message when I go into my CUI to try to modify the quick properties tab.   Pretty frustrating. I've attached a couple of images for reference.  I've repaired, re-installed and unistalled and re-installed and still have the same probelm.  
 
Dell Precision T3500
Intel(R) Xeon(R) CPU W3530 @2.8GHz
ATI FIrePRo V5800 (FireGL V)
12 GB Ram
64 BIt OS

View 3 Replies View Related

AutoCAD Architecture :: Properties Palette Not Wide Enough / Can't Read Actual Properties

Feb 13, 2013

Somehow the Properties Palette has gotten less wide- such that I can't read teh actual properties.  Previously I was able to make it wider just by hovering over it, clicking on an arrow and dragging it wider.  Not now. 

View 1 Replies View Related

AutoCAD Architecture :: Properties Palette In 2014 Shows Only Current Settings Of General Properties

Aug 13, 2013

It's not just the layer that isn't being displayed in the Properties Palette.    My 2014 Properties Palette isn't contextual--displays only the general info--none of the object specific information. 

View 2 Replies View Related

AutoCAD Architecture :: Properties For AEC Objects Not Displaying In Properties Palette?

Jan 16, 2012

A user showed me today that she cannot see any properties for a wall, door, or other AEC object in the Properties palette.

Some options like height, width, etc. are shown, but not layer, style, etc. from the General portion of the Basic tab.

Is this going to be a reinstall scenario or is there a fix for this?

View 9 Replies View Related

AutoCAD LT :: 2014 - Properties Box Does Not Display Properties Of Selected Object

Jun 6, 2013

I recently upgraded from LT2013 to LT2014. I never had any issues with 2013, but now seem to be battling with 2014. My OS is Windows 7 Home edition.

When selecting an object and then clicking the properties menu, the properties of the selected object are not displayed, but instead the properties of the selected layer are shown.

In the attached screenshot:

1) My active layer is "AM_VIEWS".

2) The layer of the object that is selected is "MEDIUM".

3) The properties dialog box shows the properties of my active layer and not the selected object.

I am therefore unable to override any settings of the selected object and manually change settings e.g. Linetype, Linetype scale etc.

View 2 Replies View Related

AutoCAD LT :: Many Perimeters For Dimension Properties Not Showing In Properties Palette

Mar 8, 2013

I recently had to reinstall my AutoCAD LT 2008 and now when I open the properties palette to make adjustments to dimensions and fine tune, many peramiters that used to be visible are no longer there and accessible.  I used to be able to adjust the dimscale as needed in the properties window, but can't now.  How do I get it back?

View 7 Replies View Related

AutoCAD Inventor :: IPN Properties In Drawing?

Jun 20, 2012

Is there any way of accessing the properties from an IPN in a drawing as opposed to its assembly - which seems to be the  default.

View 2 Replies View Related

AutoCAD Inventor :: Possible To Match Properties

Jul 9, 2013

Its it possible to match properties in inventor like AutoCad

View 2 Replies View Related

VideoStudio :: Combine Files With Different Properties?

Nov 5, 2012

I have three video files. Each has a different frames per second. Each has a different audio format. Each has different bit rates. One has upper field first, one has lower field first.

Im assuming that I cannot simply drop the three files into the time line and produce one output file (obviously with the lowest bit rate and fps).

Do I assume correct? and if so, how does one combine files with vastly different properties to produce one output file?

View 3 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved