AutoCAD Civil 3D :: Pipe Labels Display 180 And Mirror Image?
Nov 19, 2013
I created a project from scratch. I created some pipe labels showing our companies arrow block in label the and set it to Grade Check. It worked great. It point in the downward slope and at the end of each pipe. No issue. I copied the label style to an existing project I inherited and did not set up. In that project, certain variables for pipe and structure labels display backwards or mirror image. I can't figure it out. I copy those same structure and pipe labels to a new project and they display fine.
Also when I create a profile view the numbers for my vertical elevations in the profile are backwards (but plot fine). The labels mentioned above do not plot fine. I have also copied items from another project and they came in mirror image including the text.
Civil 3D 2013
Windows 8
Intel(R) Core(TM) i7-4770 CPU @ 3.40GHz
32. GB
64-bit Oepration System, x64-based processor
No Pen or Touch Input
View 9 Replies
ADVERTISEMENT
Mar 22, 2012
I have multiple profile views with a pipe network. In a number of cases, I have a pipe that extends to the end of one profile view and continues on the next. I can label the pipe on one profile but not on the other. Is there a way to add two labels to the same pipe - one label on one profile view and another label on the other profile?
View 2 Replies
View Related
Aug 15, 2013
On my drawings when I want to edit a label, I click the label, the ribbon changes and gives me options for that label, I click "edit label group" then a dialog box for that label style pops up and gives me more options.
Same drawings on another employees workspace, after clicking the label the ribbon changes, "edit label group" is selected from the ribbon, the command line then asks to pick a label you would like to edit even though you already selected a label.
What is the issue here? Does a system variable need to be set to "1" instead of "0" somewhere?
View 2 Replies
View Related
May 24, 2012
we have serveral situations when we need to label both box culvert pipes and round rcp pipes on the same junction box label. what we cant do is have civil 3d differentiate between the two, it will either give us box labels or rcp labels but not both. we are using civil 3d 2011, does 2012 offer this feature and 2011 doesnt?
View 1 Replies
View Related
Dec 3, 2012
Having problems with the spanning pipe labels in profile. Sometimes it works fine and others not at all. It will let me pick the two structures at each end and highlights the pipes, but then it will not let me pick the pipe to place the label on.
View 5 Replies
View Related
Apr 25, 2012
I click on my pipe in profile. Right click and add label. I see nothing, no label. All layers on and un-frozen.
View 6 Replies
View Related
Oct 15, 2012
I am trying to place my pipe invert labels at the actual point of the invert. When using the pipe label style composer, I have selected Anchor Point to be "Bottom Inner Diameter". Why is it that the label style still imports into the center of the pipe? No matter which anchor point I choose the label still inserts to the middle of the pipe. Is there a hidden setting that I am missing?
Win 7 Pro 64-Bit - Dell T1600
Intel Xeon 3.30Ghz
8Gb RAM
Civil 3D 2013
View 6 Replies
View Related
Jun 19, 2013
If I have a pipe that spans between two profile views, is there a way to label the pipe in each profile view with only the lineal feet that is showing in that profile view?
View 4 Replies
View Related
Sep 17, 2011
I have changed some pipe sizes in Vistas (pipe network edit), the object sizes are changed in plan & profile views except the pipe sizes in label, it appears the same sizes as before.
I tried to re apply the labels in entire plan & profile, still be the same.
View 3 Replies
View Related
Mar 30, 2012
I was looking at placing pipe information into a Profile Band. I see that I can include the following properties in a pipe label in the profile band:
<[Total Slope Across Span(FP|P2|RN|AP|GC|UN|Sn|OF)]>
<[Number of Pipes in Span(GC|UN|Sn)]>
<[Drop Across Span(Um|P2|RN|AP|GC|UN|Sn|OF)]>
Only problem is they don't actually give me the information of a spanning pipe, only a single pipe. I see no way of choosing which pipes will be spanned. Am i missing something in the creation of the profile band that allows me to choose the spanning pipes or is this broken?
View 2 Replies
View Related
Aug 12, 2009
C3D 2009. I have a style that labels the pipe diameter in section view and the type of pipe. When I label the pipe everything shows up fine. Save the drawing and re-open and my labels are gone. I can see them when is opening but after it regenerates, gone. All layers are on display set to true. Tried too many different things and no success. This issue only happens in two drawings.
View 9 Replies
View Related
Dec 29, 2011
In 2011 the pipe network cross section labels had to be exploded or they would disappear once you closed the drawing (even with saving).
In 2012 can you close and open a drawing and have the labels not disappear?
Civil 3D 2012 SP4.0 Windows 7 Enterprise 64-bit
C3D 2014 SP1
Dell M6600, Core i7 @ 2.3GHz, 16 GB ram
Dell T3500 workstation, too much ram to post
View 3 Replies
View Related
Dec 15, 2013
For some reason, while editing my pipe network, my alignment labels for my station offsets have disappeared. How can I bring them back?
C3D 2014 SP1
DELL Precision T3600
Intel Xeon E5-1650 @ 3.20GHz
NVIDIA QUADRO 4000 Dual Monitor
32 GB RAM / Win7 Pro 64-bit
View 1 Replies
View Related
Jul 15, 2009
I have a pipe network that has labels for structures and pipes. To be able to read the information better, I click on a label and try to move by the grip. The problem is that it freezes the cursor for approximately 10 seconds before I can move it to grip the label and relocate it to another place. Did I miss any setting. Since this is slowing me down in plan production.
View 1 Replies
View Related
Oct 30, 2013
I notice issues using spanning pipe labels for the first time recently after having used them for years. The slope calculated by the spanning pipe label is completely wrong. I've attached a picture in which Labeled two pipes connected by a null structure. The two labels on the bottom are the pipes labeled individually at 3.53% and 3.34%. When labeling them as a spanning pipe, if I choose the downstream pipe first and them the upstream pipe it shows me a slope of 0.48%. If I choose the upstream pipe first, then it gives me 2.88%. Either way it's wrong.
As I was writing this I decided to check and see if the pipes were flowing the same direction (Start to End or End to Start). Turns out they weren't. After flipping one of the pipes around so that they both are laid out in the same direction (Start to End from Upstream to Downstream) the label now reads 3.37%, which is correct.
Seems like an the label should honor the flow direction of the pipe, no matter if they have been laid out in opposite directions or not.
View 1 Replies
View Related
Sep 27, 2013
When labeling pipes in a pipe network; is there a way or expression to roundup the label to 6 inch interval. For example, if I have a pipe length of 2.6 feet, I want to roundup this to 3.0 feet and if I have a pipe length of 2.4 feet, I want to roundup this to 2.5 feet.
View 7 Replies
View Related
May 6, 2012
In plan production, I have created the sheets (plan & profile) as a seperate drawing.
when I open the sheets, the pipe network profile labels are missing in model & paper space. (attachment 01)
I tried to on/off the annotation visibility tabs in the lower right corner (attachement 03)
Note: While creating the sheets, I select the tabs for pipe network & copy pipe network labels to destination drawings (attachment 02).
View 2 Replies
View Related
Oct 30, 2012
I have a project I designed and grading plan is almost done. My proposed surface lables read as 1256.50. How can I get them to read just 56.50? I have a FG surface I created and am labeling using surface elevations. I am running out of room and need to free up some space. I don't want do drop my surface 1200'.
View 3 Replies
View Related
Sep 5, 2013
i've got proposed stormwater pipes crossing existing utility pipes. my proposed stormwater pipes run parallel to but offset from my road centerline alignment. i want to show the existing utility pipe as an oval where it crosses my stormwater pipe. i can get the utility to show up in the profile at the centerline alignment of my road but not at the actual point where the pipes cross. is there a way to show this?
Dell Studio XPS 9100
Intel Core i7 CPU 930 @ 2.8GHz
12GB Ram
64 bit
C3D 2012 SP3.0
View 2 Replies
View Related
Aug 14, 2013
In profile I would like to show the 'Inside Pipe Walls' line on top of the 'Pipe Hatch' is this possible, search some threads haven't found a solution.
View 5 Replies
View Related
Jul 13, 2012
I am using C3D 2012 sp2.
I have a autocad file with MEP pipe objects (piping layout inside a building). If I start a new drawing using our company (dwt) template then xref in the cad file with the MEP objects they do not display. If I start a new drawing using one of autocads default (dwt) templates then xref in the MEP objects they display fine. My question is somewhere in our company template is a setting for MEP objects to be displayed .
View 2 Replies
View Related
Jan 8, 2014
I can create labels to display stationing in a profile, but is there a way to display the coordinates in the profile instead? When I need to move my pipes I am using the station I get from the profile label and then use grip move. If I could get the N, E, I could just type it in on the Vista table.
AutoCAD Civil 3D 2012 SP4
Windows 7 (64)
View 4 Replies
View Related
Aug 15, 2013
I have a Storm pipe network for a subdivision. All of the pipe are on the same layer, using the pipe style. For some reason, only 1 of 68 pipes will display through my viewports. All of the layers within the pipe style are thawed in my viewports, as well as the layer the pipes themselves are on.
Further, when I go back to an archived file from a few days ago, all the pipes are also on the same layers and styles, and all pipes display as they should through all viewports. There seems to be no rhyme or reason for this. I am not sure what could have changed as I didn't knowing adjust anything with the pipe networks since archiving a few days ago
View 5 Replies
View Related
Feb 1, 2012
We are in the process of updating our pipe network structure label styles. The styles are displaying the inverts in a random order (Please see caption) & we'd like to show the inverts in descending order from highest pipe as first text string & lowest pipe as bottom text string. Is there a way to globally tell civil 3d to always use a descending invert order? Only fix we've found is to disconnect & reconnect the parts in order to adjust invert order.
C3D 2012 SP3 & C3D 2014 SP1
Win 7 Professional 64 Bit
View 6 Replies
View Related
Dec 2, 2010
I am having problems with the display of my structures in a profile view. Previously, when I change the inverts of the pipes connected to my structure it would automatically adjust the bottom (sump) of the box invert to match my lowest pipe. However, for some reason it has stopped doing it and is now displaying the sump invert incorrectly. I have my style set to "Display as a Boundary". I have edited the structure sump to be by both elevation and depth, but it does not update the sump elevation. I have tried to grip edit the sump but it seems to be locked at a certain elevation. I have a profile with 10+ structures and they are all at multiple depths. I realize there are minimum depths allowed by the structure, but I have exceeded the minimum depths in all cases. Attached is an image that depicts my problem. No matter what I do to change the depth it stays locked at a certain elevation.
Civil 3D 2011, SP1
View 9 Replies
View Related
Apr 12, 2012
I've got the Pipe Table style just as I need it except for one thing. I have all circular pipes and I would like the "size" column to display in inches rather than in feet. In the past I was able to multiply this number by 12 in the style composer but that doesn't seem to work anymore.
View 2 Replies
View Related
May 7, 2012
Header says it all. For example, if I set a pipestyle to display the inside walls with linetype Continuous, it works ok in plan view, but not profile.
When I select the pipe top edit its style (right click context menu), it is in the Profile View, but the changes are happening in the plan view.
Where I should set it to display how I want in the profile view?
C3D 2012 on 64bit Win 7 all up to date
Dell Precision 7core 8GB RAM
NVIDIA Quadro FX 1800M
LDT/C3D user since release 12
View 2 Replies
View Related
Dec 27, 2013
I am trying to create a surface rise:run slope label for our company template file. I have it set using the default values that I want. But right now the text is just 1:1...where we want it to read 1V:1H.
how I can keep the label dynamic to the surface, but put the V & H in the label after the values.?
View 2 Replies
View Related
May 3, 2013
I think it is normal to want a style showing stationing, speed design stattions, etc.But.... Radii of curves ? Clothoid parameters ?
Why is the reason Autodesk developers think that designers dont want to see this information instead of "add labels, aligments, multiple segments,. etc ....
(aligment by aligment ...... of a whole project ?
Civil 3D (2013)
View 9 Replies
View Related
Nov 20, 2013
Pipe network storm pipes: Fairly new to Civil3D and trying to set up parts list for the storm sewer pipe and would like the plan view to appear as it does currently. We use a polyline for centerline of pipe, similar to dashed linetype but line and space are the same, width set to pipe width.
View 1 Replies
View Related
Sep 25, 2012
I created pipe network for my storm drain project. I have located all the structures (manhole) to all angle point of my alignment as required. Also I "insert" manhole every 400' per local code requirements using the command "network layout tools; structures only. My problem is I couldn't find the tools how to trim the pipe that pass through the manhole. Please see attached pdf file.
View 1 Replies
View Related