AutoCAD Civil 3D :: Profile Band - Spanning Pipe Labels
Mar 30, 2012
I was looking at placing pipe information into a Profile Band. I see that I can include the following properties in a pipe label in the profile band:
<[Total Slope Across Span(FP|P2|RN|AP|GC|UN|Sn|OF)]>
<[Number of Pipes in Span(GC|UN|Sn)]>
<[Drop Across Span(Um|P2|RN|AP|GC|UN|Sn|OF)]>
Only problem is they don't actually give me the information of a spanning pipe, only a single pipe. I see no way of choosing which pipes will be spanned. Am i missing something in the creation of the profile band that allows me to choose the spanning pipes or is this broken?
View 2 Replies
ADVERTISEMENT
Dec 3, 2012
Having problems with the spanning pipe labels in profile. Sometimes it works fine and others not at all. It will let me pick the two structures at each end and highlights the pipes, but then it will not let me pick the pipe to place the label on.
View 5 Replies
View Related
Oct 30, 2013
I notice issues using spanning pipe labels for the first time recently after having used them for years. The slope calculated by the spanning pipe label is completely wrong. I've attached a picture in which Labeled two pipes connected by a null structure. The two labels on the bottom are the pipes labeled individually at 3.53% and 3.34%. When labeling them as a spanning pipe, if I choose the downstream pipe first and them the upstream pipe it shows me a slope of 0.48%. If I choose the upstream pipe first, then it gives me 2.88%. Either way it's wrong.
As I was writing this I decided to check and see if the pipes were flowing the same direction (Start to End or End to Start). Turns out they weren't. After flipping one of the pipes around so that they both are laid out in the same direction (Start to End from Upstream to Downstream) the label now reads 3.37%, which is correct.
Seems like an the label should honor the flow direction of the pipe, no matter if they have been laid out in opposite directions or not.
View 1 Replies
View Related
Apr 4, 2012
Is there a way to get the ProfileBandLabelGroup labels from a profile view. I see I can get the ProfileViewBandItems, but don't see a way to convert it into the labels. I'm looking to override the text components. The code below does that, it's just getting the object without having to have the user select it.
ProfileBandLabelGroup labels = ssResult.ObjectId.GetObject(OpenMode.ForWrite) as ProfileBandLabelGroup;
LabelStyleTextComponent textComponent = labels.GetAt(0).GetTextComponentIds()[0].GetObject(OpenMode.ForRead) as LabelStyleTextComponent;
Autodesk.Civil.DatabaseServices.LabelGroupSubEntity label = labels.GetAt(0);
label.SetTextComponentOverride(textComponent.ObjectId, "blue");
View 3 Replies
View Related
Jan 20, 2010
I cannot for the life of me get the start and end labels for any band to display within a profile view. Each band has the 'label start' and 'label end' labels ticked and the major/minor labels display at every other point but don't display anything at the start of the view or end. The profile views are taken from a simple straight alignment and the profiles themselves extend the full length of the view.
View 9 Replies
View Related
Aug 13, 2012
I am running CV3D 2011 on a Windows 7 64 bit workstation. I have a road profile that has a band which labels the existing and proposed profile elevations. For some reason the profile band labels (including the stations) randomly disappear and all you see is the band box. If you REgen they will reappear but will dissapear again when you plot preview and they WON"T plot...even though they are there in the drawing!
Civil 3D 2013 SP2 | Win 7 64-bit SP1
Intel Core i5-2500 @ 3.30GHz, 8GB Ram | ATI Radeon HD 5450
View 4 Replies
View Related
Mar 21, 2013
I'm trying to add assign a Pipe Network to a profile view Band in Civil 3D 2011. I was using COM to add profiles to bands because I couldn't figure out how to do it in .NET. But when it comes to pipe networks I don't see how you can do that with COM. How the .NET implementation is supposed to work? Here's the code I have that works for COM, except for the pipe networks. I essentially need to assign the correct pipe network to the band.
public static void AddProfileToBand(this ProfileView profileView, ObjectId profObjId, List<BandItemInfo> bandStyleInfosFromSet, ObjectId profileBandSetId){
using (Transaction tr = Application.DocumentManager.MdiActiveDocument.TransactionManager.StartTransaction())
[code]....
View 1 Replies
View Related
Apr 25, 2012
I click on my pipe in profile. Right click and add label. I see nothing, no label. All layers on and un-frozen.
View 6 Replies
View Related
Jun 19, 2013
If I have a pipe that spans between two profile views, is there a way to label the pipe in each profile view with only the lineal feet that is showing in that profile view?
View 4 Replies
View Related
May 6, 2012
In plan production, I have created the sheets (plan & profile) as a seperate drawing.
when I open the sheets, the pipe network profile labels are missing in model & paper space. (attachment 01)
I tried to on/off the annotation visibility tabs in the lower right corner (attachement 03)
Note: While creating the sheets, I select the tabs for pipe network & copy pipe network labels to destination drawings (attachment 02).
View 2 Replies
View Related
Jul 9, 2012
where to change the text height and color for the lower band where the stations are. Also, how do I get the exist grade and proposed grade to show at the specified stations vertically like LDD used to do it.
Second, how do i mask the pipe in the manholes on the profile. Right now i can see the pipe inside the manhole. I clicked "enable masking" under the structure properties but no luck.
View 2 Replies
View Related
Dec 12, 2013
When I generate a band and the points that need to be labelled are very close to each other there is the possibility to stagger the labels (left, right, to both sides).
This works as I would expect it to.What I haven’t been able to determine is whether it is possible to adjust or influence the spacing between the staggered labels.
View 2 Replies
View Related
Oct 29, 2013
I'm trying to create a profile view band style to display a gradient as a fraction i.e 1/100 rather than a % I've tried creating an expression to do this ( see below) the sum works but I don't get a solution/answer just the sum displayed on the band.Basically the sum is length/change in elevation
for clarification / = divide
Expression
(<[Pipe Start Chainage(Um|FD|P3|RN|AP|GC|UN|Sn|OF)]> - <[Pipe End Chainage(Um|FD|P3|RN|AP|GC|UN|Sn|OF)]>) / (<[Start Invert Level(Um|P2|RN|AP|GC|UN|Sn|OF)]> - <[End Invert Level(Um|P2|RN|AP|GC|UN|Sn|OF)]>)
View 4 Replies
View Related
Jan 23, 2011
I'm currently setting up a band set and want to include a band "pipe invert depth" i.e. basically trench depth.
There are properites in the band label style composer for "pipe invert level" and for "cover" and for "pipe diameter" but not pipe invert depth.Is there a way to display the pipe invert depth relative to the reference (design) surface/alignment?
A secondary question to this is can you use basic arithmetic in the band label style composer? eg pipe cover + pipe diameter?
View 9 Replies
View Related
Jun 14, 2013
Am I limited to the fields that appear on the label for a pipe network data band, or can I add my own customized expressions?
Using Building Design Suite Ultimate 2014
View 6 Replies
View Related
May 22, 2013
How to upload Civil 3d Sample profile with full band
View 1 Replies
View Related
Jun 20, 2008
In the profile band the elevations are set to 3 decimal places. I just want to get it to 2 places.
View 3 Replies
View Related
Mar 21, 2012
Attached is a drawing with my profile along with elevations in the band.
UPPER BAND - has proposed road elevations on the left and existing road elevations on the right.
LOWER BAND - has pipe elevations on the left and the SAME existing road elevations on the right.
I've been messing around in the profile view properties but cannot hide the duplicate elevations in one of the bands.
View 1 Replies
View Related
Aug 26, 2013
In the Band Style_A pdf you can see the location of my elevation labels, they are below the bottom line of my profile view grid. In the Band Style_B pdf the labels are showing up in the proper location (above the bottom line of the profile view grid). To move the labels to the proper location I changed the "Gap" setting from 12.5 to -24. Is there a way to change this setting in my "style" rather than have to go make this change to the style every time I use it in a profile?
View 3 Replies
View Related
Jan 16, 2013
I did a grading, created surface with it and draw a profile view. Everything seems to be good, except with the vertical geometry band. I need to fix slope and length only at break point, means PI (blue line), but aligment has created more PI with each surface tringular line at intersection (us i note). Is there any why to specify PI only at a break points?
I can erase PI manually on static profile view mode, but i desire to do it in dynamic mode..., in case when conditions changes.
View 2 Replies
View Related
Apr 7, 2012
So I've got a collection of the LabelGroupSubEntity in the ProfileDataBandLabelGroup. I need to replace some values inside them based on what Vertical Geometry Point they are labeling. Is there an easy way to determine what station value it is labeling?
View 2 Replies
View Related
Jul 2, 2013
Is there a way to make the Profile band title a specific text style? At the moment it seems that when I access
Profile Properties>Pick Band Style>Profile Data Bans Style>Compose Label>Label style composer
I go to the Contents (under Text) and edit it to bring up the Text component Editor.
In this if I go to the Format Tab the text style is set to annotative, however under that it says font style as an overide. How do I remove the override and set the style of the text to the text style. And how do i change the text style.
View 3 Replies
View Related
May 23, 2013
i'm trying to get my data band flush with the bottom of my profile view. See attached screenshot.
Windows 7 x 64 bit
NVidia Quadro 2000 Dual Monitor
6.00 GB RAM
Intel Xeon W3550 @ 3.07 GHz
Civil 3D 2013 SP 2, Civil 3D 2012 SP2, Civil 3D 2011 V3, Civil 3D 2010 V3
View 2 Replies
View Related
May 14, 2013
How to add super elevation detail on Profile band.
View 1 Replies
View Related
Sep 23, 2010
We are using Civil 3D 2010, Version 4.1 and it is being used on both WinXP and Win7.
This is an issue that has been coming up at different times with profile views and them shifting when viewed from our viewports in our layout tab. It looks correct in the model space. But it shifts to the right 10' in the layout tab. We have 7 tabs in this drawing. I have looked through all of the profile view settings and it does not seem like any of these are the issue. I created a new viewport in the same tab and received the same shift to the right. I then created a new tab in the same drawing (not copied from the one that has the issue), created a new viewport, and the shift is not there. The PSLTSCALE, MSLTSCALE, and LTSCALE are all set to 1 in all of th tabs.
Woudl there be a layout tab setting that is causing this? This is happening on all of our machines with this drawing so I know it is not a specific user/machine issue. I have attached a .pdf showing the three cases described above if that were to provide any additional insight.
View 9 Replies
View Related
Jul 13, 2012
I want to change my elevations color to green and the other one to yelow. I can't not find this option. I using 3D 2011.
View 1 Replies
View Related
Sep 25, 2013
How to set change the radius to degrees in horizontal geometry band set profile.
View 2 Replies
View Related
Oct 15, 2013
The list of bands with location selected as 'bottom of profile view' is blank, where as 'top of profile view' displays the info correctly. With this error I can't select any of the band to add remove modify them.
I have attached 2 pdf's showing top and bottom views.
View 1 Replies
View Related
Jun 23, 2012
How to show the deflection anglesof alignments. I want to show those angles in band set or profile view.
AutoCAD Civil 3D 2012 SP 2
View 9 Replies
View Related
Oct 12, 2006
Where the heck do I find the offset which controls the distance between the profile grid and my profile data band?
I have compared settings between ones that look the way I want and I'm just not seeing it.
(The attached doc shows you what I'm up to)
View 9 Replies
View Related
Mar 22, 2012
I have multiple profile views with a pipe network. In a number of cases, I have a pipe that extends to the end of one profile view and continues on the next. I can label the pipe on one profile but not on the other. Is there a way to add two labels to the same pipe - one label on one profile view and another label on the other profile?
View 2 Replies
View Related