AutoCAD Civil 3D :: Profile Data Band Label Group?
Apr 7, 2012
So I've got a collection of the LabelGroupSubEntity in the ProfileDataBandLabelGroup. I need to replace some values inside them based on what Vertical Geometry Point they are labeling. Is there an easy way to determine what station value it is labeling?
View 2 Replies
ADVERTISEMENT
Jul 13, 2012
I want to change my elevations color to green and the other one to yelow. I can't not find this option. I using 3D 2011.
View 1 Replies
View Related
Jun 14, 2013
Am I limited to the fields that appear on the label for a pipe network data band, or can I add my own customized expressions?
Using Building Design Suite Ultimate 2014
View 6 Replies
View Related
May 23, 2013
i'm trying to get my data band flush with the bottom of my profile view. See attached screenshot.
Windows 7 x 64 bit
NVidia Quadro 2000 Dual Monitor
6.00 GB RAM
Intel Xeon W3550 @ 3.07 GHz
Civil 3D 2013 SP 2, Civil 3D 2012 SP2, Civil 3D 2011 V3, Civil 3D 2010 V3
View 2 Replies
View Related
Oct 12, 2006
Where the heck do I find the offset which controls the distance between the profile grid and my profile data band?
I have compared settings between ones that look the way I want and I'm just not seeing it.
(The attached doc shows you what I'm up to)
View 9 Replies
View Related
May 13, 2013
I can label the superimposed profile but c3d uses the stations of main profile of profile view.
Thinking on the future.... c3D can have the ability of use superelevation values to calculate the right values of superimposed profiles ?
View 1 Replies
View Related
Oct 29, 2013
A method (possible expressions) to create a profile view label that can reference pipe or structure data?
View 5 Replies
View Related
Jul 9, 2012
where to change the text height and color for the lower band where the stations are. Also, how do I get the exist grade and proposed grade to show at the specified stations vertically like LDD used to do it.
Second, how do i mask the pipe in the manholes on the profile. Right now i can see the pipe inside the manhole. I clicked "enable masking" under the structure properties but no luck.
View 2 Replies
View Related
Jun 21, 2013
Labels doesn't appear in all grade breaks and seems to have a relation regarding the side of the points!!!!
View 1 Replies
View Related
May 22, 2013
How to upload Civil 3d Sample profile with full band
View 1 Replies
View Related
Jun 20, 2008
In the profile band the elevations are set to 3 decimal places. I just want to get it to 2 places.
View 3 Replies
View Related
Mar 21, 2012
Attached is a drawing with my profile along with elevations in the band.
UPPER BAND - has proposed road elevations on the left and existing road elevations on the right.
LOWER BAND - has pipe elevations on the left and the SAME existing road elevations on the right.
I've been messing around in the profile view properties but cannot hide the duplicate elevations in one of the bands.
View 1 Replies
View Related
Aug 26, 2013
In the Band Style_A pdf you can see the location of my elevation labels, they are below the bottom line of my profile view grid. In the Band Style_B pdf the labels are showing up in the proper location (above the bottom line of the profile view grid). To move the labels to the proper location I changed the "Gap" setting from 12.5 to -24. Is there a way to change this setting in my "style" rather than have to go make this change to the style every time I use it in a profile?
View 3 Replies
View Related
Apr 4, 2012
Is there a way to get the ProfileBandLabelGroup labels from a profile view. I see I can get the ProfileViewBandItems, but don't see a way to convert it into the labels. I'm looking to override the text components. The code below does that, it's just getting the object without having to have the user select it.
ProfileBandLabelGroup labels = ssResult.ObjectId.GetObject(OpenMode.ForWrite) as ProfileBandLabelGroup;
LabelStyleTextComponent textComponent = labels.GetAt(0).GetTextComponentIds()[0].GetObject(OpenMode.ForRead) as LabelStyleTextComponent;
Autodesk.Civil.DatabaseServices.LabelGroupSubEntity label = labels.GetAt(0);
label.SetTextComponentOverride(textComponent.ObjectId, "blue");
View 3 Replies
View Related
Jan 16, 2013
I did a grading, created surface with it and draw a profile view. Everything seems to be good, except with the vertical geometry band. I need to fix slope and length only at break point, means PI (blue line), but aligment has created more PI with each surface tringular line at intersection (us i note). Is there any why to specify PI only at a break points?
I can erase PI manually on static profile view mode, but i desire to do it in dynamic mode..., in case when conditions changes.
View 2 Replies
View Related
Nov 5, 2008
I have an EG and FG data band for sections that works correctly. When i plot sections and it asks me specify surfaces 1 and 2, I choose my EG and FG surfaces appropriately. Then when the section displays the Section 1 and Section 2 are both set to the EG section of that specific sample line. If i change the section view properties manually it works but I'll have to do it individually for each section.
Also, is it necessary to create a FG surface from the corridor or can i get the data band to read from the corridor section itself?
View 8 Replies
View Related
Jun 13, 2013
A coworker who is no longer with us set up the data band styles & settings in our template, and they were working fine in 2011. Then, on a new job in 2011, I encountered this problem. I gave up.
Now I'm working in 2013. The template was brought forwards, so it's the same settings, and I'm hitting the same problem as before. The difference is this time I'm working on a really long profile, and I really really want the bands to work.
Here's the problem.
The ones I checked in blue are not part of the data band. They are profile view labels, and they show the correct stations.
The ones circled in red are the data band. As you can see I need to work on my gap settings, but that's not my problem. The problem is the location of these labels. There is indeed a PVI at station 1+165, but the label is 40m away from that station! I don't know where to start digging to find the setting to tell that label to move 40m to the right, and tell 1+135.86 to move 20m to the right.
View 3 Replies
View Related
May 27, 2013
I've been working with Civil 3D for a while and I've gotten the Profile View and Data Bands down.Whenever we create an alignment with only two vertices (at each endpoint) and make the Northings, Eastings, and Elevations show in the data bands, the start and end show no data. (As below) Now I'm sure the data band is set up correctly because if I add a vertex somewhere along the alignment, all the missing data shows up.
View 3 Replies
View Related
Jul 2, 2013
Is there a way to make the Profile band title a specific text style? At the moment it seems that when I access
Profile Properties>Pick Band Style>Profile Data Bans Style>Compose Label>Label style composer
I go to the Contents (under Text) and edit it to bring up the Text component Editor.
In this if I go to the Format Tab the text style is set to annotative, however under that it says font style as an overide. How do I remove the override and set the style of the text to the text style. And how do i change the text style.
View 3 Replies
View Related
Jan 20, 2010
I cannot for the life of me get the start and end labels for any band to display within a profile view. Each band has the 'label start' and 'label end' labels ticked and the major/minor labels display at every other point but don't display anything at the start of the view or end. The profile views are taken from a simple straight alignment and the profiles themselves extend the full length of the view.
View 9 Replies
View Related
Aug 13, 2012
I am running CV3D 2011 on a Windows 7 64 bit workstation. I have a road profile that has a band which labels the existing and proposed profile elevations. For some reason the profile band labels (including the stations) randomly disappear and all you see is the band box. If you REgen they will reappear but will dissapear again when you plot preview and they WON"T plot...even though they are there in the drawing!
Civil 3D 2013 SP2 | Win 7 64-bit SP1
Intel Core i5-2500 @ 3.30GHz, 8GB Ram | ATI Radeon HD 5450
View 4 Replies
View Related
Mar 30, 2012
I was looking at placing pipe information into a Profile Band. I see that I can include the following properties in a pipe label in the profile band:
<[Total Slope Across Span(FP|P2|RN|AP|GC|UN|Sn|OF)]>
<[Number of Pipes in Span(GC|UN|Sn)]>
<[Drop Across Span(Um|P2|RN|AP|GC|UN|Sn|OF)]>
Only problem is they don't actually give me the information of a spanning pipe, only a single pipe. I see no way of choosing which pipes will be spanned. Am i missing something in the creation of the profile band that allows me to choose the spanning pipes or is this broken?
View 2 Replies
View Related
May 14, 2013
How to add super elevation detail on Profile band.
View 1 Replies
View Related
May 9, 2012
As shown in the attached drawing, the station label where the superelevation transitions back into normal crown shows with 4 decimal places. We have verified that all precisions are set to 0.01ft. The normal crown station at the begin transition shows with 2 decimal places.
Civil 3D 2013 SP1
Dell T3500 Workstation
Intel Xeon E5630 @ 2.53 GHz
12 Gig of RAM
Nvidia Quadro FX3800
Window 7 x 64bit OS
View 2 Replies
View Related
Feb 5, 2008
Is there a way to export the band data for an alignment with two profiles? I have an existing ground and a proposed profile. Can I export the station and elevation data from the band for both profiles?
View 9 Replies
View Related
Sep 6, 2012
C3D 2013. We have profile line labels, some of which get manually edited (for example, change the "<[Tangent grade(FP|P2|RN|AP|GC|UN|SD|OF)]>" to a static number such as 0.29%).
However, if you CTRL+Click and select one of these labels and change the style of that one label, then the manual edits are lost and the label reverts back to the default string.
Is there any way to turn this behavior off?
View 1 Replies
View Related
Sep 23, 2010
We are using Civil 3D 2010, Version 4.1 and it is being used on both WinXP and Win7.
This is an issue that has been coming up at different times with profile views and them shifting when viewed from our viewports in our layout tab. It looks correct in the model space. But it shifts to the right 10' in the layout tab. We have 7 tabs in this drawing. I have looked through all of the profile view settings and it does not seem like any of these are the issue. I created a new viewport in the same tab and received the same shift to the right. I then created a new tab in the same drawing (not copied from the one that has the issue), created a new viewport, and the shift is not there. The PSLTSCALE, MSLTSCALE, and LTSCALE are all set to 1 in all of th tabs.
Woudl there be a layout tab setting that is causing this? This is happening on all of our machines with this drawing so I know it is not a specific user/machine issue. I have attached a .pdf showing the three cases described above if that were to provide any additional insight.
View 9 Replies
View Related
Aug 8, 2013
I'm trying to label my Profile label stations as raw stations, 20~20 meters, and I'm not being able to adapt the format to STATION 0, STATION 2, without any plus zeros or +, or -, or commas, or anything, as following in the image.
Is there a easy way to do it?
View 2 Replies
View Related
Sep 25, 2013
How to set change the radius to degrees in horizontal geometry band set profile.
View 2 Replies
View Related
Oct 15, 2013
The list of bands with location selected as 'bottom of profile view' is blank, where as 'top of profile view' displays the info correctly. With this error I can't select any of the band to add remove modify them.
I have attached 2 pdf's showing top and bottom views.
View 1 Replies
View Related
Jun 23, 2012
How to show the deflection anglesof alignments. I want to show those angles in band set or profile view.
AutoCAD Civil 3D 2012 SP 2
View 9 Replies
View Related