AutoCAD Civil 3D :: Not Getting Design Levels Of Assembly

Dec 12, 2013

I'm not getting the design levels of assembly, just major offset and elevation, how can i get all design levels from where my assembly is changing and where it is matching to the existing surface, is there any band problem or anything else, im sending the view that how i'm getting my cross section and also i want to know that how can i control text size because it is too big for sections.

View 6 Replies


ADVERTISEMENT

AutoCAD Civil 3D :: Section Band Style - Design Levels At Grade Breaks - No Triangles

Feb 26, 2012

What I would like to achieve is a section band style for bulk earthworks and simple access roads that shows the design level at Grade Breaks only. The problem I am having is that Grade Breaks are being recognised as where the sample line crosses a triangle, not where the the grade actually changes/crosses a feature line.

A have a number of simple platforms, that I have created using an infill from feature lines, usually these platforms are surrounded entirely by feature lines of the same height. As to be expected, Civil 3d creates a few flat triangles, and as a consequence, all of the points where the sample line crosses these show up on my band style. Is there any way to achieve this band style?

View 2 Replies View Related

AutoCAD Inventor :: Copied By Design Assistant Assembly Cannot Be Altered In Design Assistant

Apr 10, 2012

I  just made a copy of assembly in Design Assistant.I opened the copied assembly in Design Assistant to make some changes.Parts are accessible but I have only "Clear" option possible. URL....

View 2 Replies View Related

AutoCAD Inventor :: Incorrect Mass For Assembly With Levels Of Detail

Sep 20, 2013

I have an assembly file in which I have created several levels of detail.  My intent was to suppress specific parts in the assembly (for views in the idw and to calculate the weight of the assembly).

I have noticed that the mass is incorrect for the level of detail that I want calculated.  I determined this after creating a new assembly and deleting all parts that were not used in this level of detail.  And, by viewing all parts individually and adding them up by hand.

All parts in the assembly have the correct density.  I have selected to calculate the mass properties of the active level of detail when updating.

My questions:  Am I correct in assuming that the assembly will caculate only the parts that are not suppressed?  Or, am I thinking of it wrong?  Is this particular assembly messed up?  I haven't noticed this before and am now concerned that my weights have been incorrect.

My solution to use right now is to create a new assembly just for figuring out the weight.  I think there is a better way.

View 5 Replies View Related

AutoCad 2D :: Conveyor Or Assembly Line Design

Aug 8, 2013

Designing conveyor or assembly lines in autocad? I know there is Factory layout, but my boss will not pay for the extra softwar. She wants me to get them done with AutoCAD. Im not new to CAD, but she needed me to move to working with line layouts. Also what sites and literature can i study to begin to understand the layout process. Im not talking about 3D tools or part design, its all 2D. Im also looking for the in's and out's of laying out a line for food and bottle product lines. Im thinking the equipment will be a block and possibly being dynamic blocks so that i can lengthen and shorten the parts to fit the space.

View 0 Replies View Related

AutoCAD Inventor :: Scissor Jack Assembly Design 3

Mar 26, 2012

I am working on a design at the moment using Inventor 2012.It is a Scissor Jack. It has been designed to specific dimensions.Although I am making up the majority of them as I go along.Dim's spec's of which I must design to are as follows,

Max Height @ Open position = 250mm. (must be kept)
Min Height @ Closed position = 70mm. (must be kept)
Max width = 75mm. (must be kept)

The rest I have been taking from other designs of which I saw during my investigation.I have been modelling in such a way trying to adapt the open & closed position limitations with the use of constraints as my maximum & minimum limits. In doing so I have set a Drive Constraint so I can show the jack in its mechanical motion. I don't mind making any changes that will work to achieve completing it to act as it should. I believe there is still some tweaking to be done to it, but I feel the actual engineering design to be almost sound. There is an issue with the base via support arms. I cannot have the support arms moving past the floor level.

I will need to place location pins through the saddle & base connecting the arms. Finally If possible alter the gear teeth so that they interlink & coincide with each other. My screw rod also needs to work properly & turn also the nut needs to be localised in the correct position fixed on the screw rod at the end of the Side sleeve.

View 2 Replies View Related

AutoCAD Inventor :: Add Design State Of Parts In Assembly Drawing

Aug 8, 2013

I have an assembly drawing that i would like to have in the partlist a column with the design state of each part of the assembly, how can i do that, since that property is not in the partlist column chooser.

View 3 Replies View Related

AutoCAD Inventor :: Drop Part Into Assembly In Its Design Axis Position 2103

Oct 17, 2013

I have several parts designed "car line" in their respective parts.

I would like to simply add them to an assembly in their respective axis positions.

Obviously "place" drops in in an arbitrary position to then be "Assembled". Not what I am looking for.

I was looking for a copy/  paste function between part / assembly but there seems no way to paste into an assembly.

View 6 Replies View Related

AutoCAD Civil 3D :: Creating A Rail Sub Assembly In Sub Assembly Composer 2013

Jul 11, 2013

I thought I created a rail sub assembly.

So I created the rail sub assembly everything looks great in sub assembly composer.

Start a new dwg data reference in the rail alignment, Note the rail alignment type is set to rail.

Create an assembly and under the Construction tab for the assembly the Assembly Type is set to Railway. Attach my custom sub assembly to this assembly.

Created a corridor and I get this error: Something wrong with current subassembly: Operation is not valid due to the current state of the object. 

So I delete my sub assembly attach the Civil 3D Rail Single sub assembly. Re run corridor and everything works fine.

So I promote the alignment change type to centerline. Delete the Rail Single sub assembly put my rail sub assembly back. Rerun the corridor and everything works.

So then I undo everything up to the point of promoting the alignment.

Opened the base file changed the alignment type to centerline.

When I tried to synchronize the references I ended up a broken reference with the following error. Invalid reference. Synchronization failed

Not good we already have plan sheets cut.

where in sub assembly composer were do I define the sub assembly to be for Rail? 

View 2 Replies View Related

AutoCAD Civil 3D :: Iterating Height Levels For A Polyline

Jan 20, 2013

I have a problem iterating heights when making a polyline between two different points that have Z-values. I've used Autocad Civil 3D for working with geodetic data with height measurements before and I remember using geodetically measured height values, transforming them into a surface and then when I create a 3Dpolyline within this area the polyline automatically gets z-values that change along the line.

In other words, I could use this 3Dpolyline to obtain a profile that gives me z-values even where there is no exact point with a value has been physically measured. It was a while ago I worked with Autocad and now when I started again I have a similar problem but can't manage to create a surface and get iterated values.

My exact problem this time is:

I have a sewage pipe that runs for several kilometers that is drawn as a 3Dpolyline, with correct x- and y-values. It doesn't have any z-values yet and these are what I want to obtain. I want the polyline to have continuous z-values that changes along the polyline (not only in vertexes) so that a smooth profile can be drawn if wanted. I have data of measured actual z-values for approximately every 500 meters or so along the sewage pipe and these are currently drawn as 3Dpolylines of around 20 meters going perpendicular to the pipe (as in the picture). In other words there are bars with z-values crossing the pipe all along the stretch. Now, what I want to do is to somehow make the polyline that represent the pipe to get the heights from these perpendicular bars with the measured z-values. If I try to draw a new 3Dpolyline between two of the measured bars where the actual pipe is supposed to be, the end vertexes of the 3Dpolyline gets the z-values of the bars. However, the value in between the bars gets the Z-value 0. So, if I start a 3Dpoly on bar 1 then continue the pipe with another vertex, and then finish off at the second bar I will have 2 vertexes with the correct z-value but the middle vertex will be incorrect (0). How do I get the pipe to get the correct z values automatically iterated from the values on the crossing bars? Is this even possible to do? Should I create a surface from the bars first, and in that case how do I do that? If possible I don't only want the vertexes between bars to have iterated z-values, I also want the entire line to have a correct value.

I've attached a crappy image made in paint (since I don't have Autocad on my home PC, only at the office). And just to make things even clearer I'll give an example. Let's say the pipe distance from 1 to 2 is 10 meters, the distance between 1 to 3 is 30 meters and the z-values of bar A and bar B is 10 and 25 respectively. So, when I draw a 3Dpolyline from 1 to 4, I want the vertex 2 to automatically get z-value 15 (since it's 1/3 on the way to B). In the same way, I would like for example the point on the pipe that is right in between 2 and 3 to have the z-value 20. I won't mind redoing the bars to for example singular points instead, if that makes it all easier.

View 9 Replies View Related

AutoCAD Civil 3D :: Channel Levels On Long Section

Oct 25, 2013

I have created an alignment and long section and over layed my assembly to produce the corridor through my alignment. However it is standard practice in the UK to show the channel levels on a long section.

View 3 Replies View Related

AutoCAD Civil 3D :: Spot Levels At Decimal Point

Apr 29, 2013

I've got a cut./fill plan with red and green surface spot level labels (derived via a grid) but wonder if there is a way to make the decimal point coincident with the with "X" marker.

View 2 Replies View Related

AutoCAD Civil 3D :: Stretching Blips Without Inheriting Levels

Aug 7, 2013

I have a civil3d model and now have an amended layout which I need to update to.

xref'd layout is 2d so I want to snap blips on my feature lines from the original location to new location while maintaining their z value.

I know you can turn off and on the ability to pick z values but can't remember the command (lost notes).

I have tried changing the osnapz option with now luck.

View 2 Replies View Related

AutoCAD Civil 3D :: Adding A Sub-assembly To An Assembly?

Jul 19, 2013

I have a finished corridor, but now I need to add marked points to label a few key grade breaks in my cross sections.  When I attempt to add the marked points on some of my sub-assemblies it gives me the error that the sub-assembly is not part of the assembly.  I can right click the sub-assemly and choose "Add to Assembly" but when I rebuild the corridor it strips all the sub-assembly data from my assembly and leaves me with essentially a null assembly for the range.

View 4 Replies View Related

AutoCAD Civil 3D :: Adding Building Levels To Existing Ground

Oct 12, 2012

I have an existing ground surface with all different z co-ords and im trying to add three proposed buildings to my exisiting ground with all the builidngs having a level of 32.5 as a minimum, however at some points the ground is higher than 32.5 and I only want to raise my existing ground to 32.5 within the proposed buidling layout if it is below 32.5 as im doing a flood calculation. What do i need to for this?

View 2 Replies View Related

AutoCAD Civil 3D :: Turn Off Different Levels Of Shading In Subassemblies That Show Up

Dec 18, 2012

is there a way to turn off different levels of shading in the subassemblies that show up? when i orbit my road, i cant clearly see what is going on, and would like to turn off some shading. see image, i want to turn off where the arrows are pointing.

View 2 Replies View Related

AutoCAD Civil 3D :: Importing MX Highway Design

Sep 2, 2013

I am looking into switching to AutoCad Civil 3D from MxRoads. Up to now I have been using Mx and have a large back catalogue of roads work all in MX formats, Input files, Genios etc.

Given that Mx is string based and Civil 3D appears to be section based, I'm wondering if when you import a genio created in Mx, is there a way to "link" a carriageway string to the master string, without having to recreate the alignment from scratch. If I needed to do a quick change to a vertical alignment or a road widening I want to be able to do without reinventing the wheel! I need to ensure that the program can recognize the relevant way string that matches the Master string.

View 9 Replies View Related

AutoCAD Civil 3D :: Profile And Corridor Design

Jan 8, 2014

I need to design a project but ı cant..ı have two profiles in use for one alignment..ı want to use left profile for left side, use right profile for right side.and ı want to draw cross section only one..how can ı design like this project..

View 8 Replies View Related

AutoCAD Civil 3D :: Road Design File

Nov 4, 2013

Road design civil 3d complete files (Plan, Profile with complete band, Assembly , corridor, sections etc .

View 5 Replies View Related

AutoCAD Civil 3D :: Stream Restoration Design

Jun 24, 2013

How to do a stream restoration design with corridor modeling. for the low flow channel pool, i will have alternate riffle and pool sections. my understanding is riffle for X feet, then pool for Y feet, then repeat, per the riffle to pool spacing requirements.

my question is regarding the left pool and right pool sections. please see attached images. for left pool, width A > width B and vice versa. A+B is the same for both left and right pools. left pool assembly has to be applied when the centerline alignment is curving outward to the left side, right pool when curving outward to the right side.

is there a way to specify in corridor modeling when an assembly is to be applied based on the direction of the centerline alignment curves?

View 2 Replies View Related

AutoCAD Civil 3D :: Integrating Infraworks / 3Ds Max Design

Jul 23, 2013

The following video show a dam in China using Infraworks and Civil 3D URL....

During the first 25 secs or so, there is a sequence showing a disposal area created in Civil 3D but with a texture that isn't the draped aerial image (and there are further examples of this elsewhere).

How does one get surfaces etc that aren't derived from a corridor to show in this way in Infraworks. There doesn't seem to be any workflow in the available information to address non linear projects.

Additionally the 3ds Max workflows seem to be geared up for linear projects e.g. roads only - any tips for non linear projects e.g. earthworks platforms?

View 2 Replies View Related

AutoCAD Civil 3D :: How To Design Sewer Line

Apr 19, 2013

Looking for a reference or example how to design a sewer line in civil 3d.

View 6 Replies View Related

AutoCAD Civil 3D :: Subdivision Design Workflow

Sep 13, 2012

Conceptual design process for a new subdivision with say 100+ lots, and 5-6 roads within it. 

What I'd like is to learn a workflow that lets me adjust the alignments/profile with a minimum amount of effort to re-layout 100+ lots, and which lets us explore design options more interactively.  Once we pin down a few alignment options, I would create a simple corridor with multiple baselines to develop the grading concept.

One thing that irks me so far is that the Create ROW command is nice, but it's not dynamic to the alignments.How do you handle cul-de-sacs on this process?

View 9 Replies View Related

AutoCAD Civil 3D :: Elevation Design Value Is Greyed Out

May 31, 2013

I am pretty new to subassemblies and corridors and I think I have the jist of it but I have a few questions.

How do I lower stations of my corridor? I am making a grassed waterway and my corridor seems just ride on the surface.  I get to the parameter editor but the elevation design value is grayed out, so I can't change it.

View 2 Replies View Related

AutoCAD Civil 3D :: How To Use It To Design Open Channel

May 9, 2013

how can i use civil 3d to design an open channel?

View 3 Replies View Related

AutoCAD Civil 3D :: Copy Blocks From Design Center?

Jan 22, 2013

Can you open two dwgs and copy blocks from one design center to the other?

View 3 Replies View Related

AutoCAD Civil 3D :: Design Profile Beginning And End Label

Jul 11, 2012

I'm trying to label the beginning and end points of a design profile (yellow line in the attached image) using the Horizontal Geometry Station Label tool. For some reason they will not show up.

View 1 Replies View Related

AutoCAD Civil 3D :: Exporting Design Data To Trimble?

Aug 8, 2013

We're moving to Trimble Access on the survey data collectors which means that we have to export design data using Trimble Link and then use Trimble Business Center to examine the data and do any editing before sending it to the field.

So far I've found that alignments, profiles and surfaces seem to transfer OK.  Corridors however have been an almost total failure. 

Civil 3D 2012 & 2013 & 2014
Toshiba Qosmio X505-Q890
2 x i7 - Q740 quad core CPU's
8GB of RAM
60GB SSD + 500GB HDD
NVidia GeForce GTS 360M - driver 8.17.13.0697
Win 7 Home Premium

View 2 Replies View Related

AutoCAD Civil 3D :: Design Profile PVIs Disappearing?

Dec 15, 2013

Working in Civil 3D 2014 SP1 I have a Design Profile that I have created by setting the Existing Profile to 'Static' and Creating a Copy of the Existing Profile... This leaves me with a Design Profile that follows the Existing Surface. The problem begins when I delete a section of PVI's and introduce new 'Design PVI's'... I have found that at apparently random times my Design PVI's have been lost and replaced with the original copied PVI's that follow the Existing Surface. This has occurred more than once and I can't find any reason as to why this may be occurring...?

Currently using Civil 3D 2013 & 2014 SP1

View 6 Replies View Related

AutoCAD Civil 3D :: Open Design Cad Files In Vrs 2012?

Dec 17, 2013

Is there any way to open or convert Design Cadd files to be useable in vrs 2012 ?

View 4 Replies View Related

AutoCAD Civil 3D :: Cannot Get DC Online Tab To Show On Design Center

Nov 1, 2012

I cannot get the DC Online tab to show on the Design Center. I have enabled it through the CAD manager Control Utility. I have shut down CAD and restarted it and still no tab.

View 3 Replies View Related